Journal of Geophysical Research | 1998

New insights into lightning processes gained from triggered-lightning experiments in Florida and Alabama

Vladimir A. Rakov; Martin A. Uman; K. J. Rambo; Mark I. Fernandez; Richard J. Fisher; G. H. Schnetzer; Rajeev Thottappillil; A. Eybert-Berard; J.-P. Berlandis; P. Lalande; A. Bonamy; P. Laroche; A. Bondiou-Clergerie

Analyses of electric and magnetic fields measured at distances from tens to hundreds of meters from the ground strike point of triggered lightning at Camp Blanding, Florida, and at 10 and 20 m at Fort McClellan, Alabama, in conjunction with currents measured at the lightning channel base and with optical observations, allow us to make new inferences on several aspects of the lightning discharge and additionally to verify the recently published “two-wave” mechanism of the lightning M component. At very close ranges (a few tens of meters or less) the time rate of change of the final portion of the dart leader electric field can be comparable to that of the return stroke. The variation of the close dart leader electric field change with distance is somewhat slower than the inverse proportionality predicted by the uniformly charged leader model, perhaps because of a decrease of leader charge density with decreasing height associated with an incomplete development of the corona sheath at the bottom of the channel. There is a positive linear correlation between the leader electric field change at close range and the succeeding return stroke current peak at the channel base. The formation of each step of a dart-stepped leader is associated with a charge of a few millicoulombs and a current of a few kiloamperes. In an altitude-triggered lightning the downward negative leader of the bidirectional leader system and the resulting return stroke serve to provide a relatively low-impedance connection between the upward moving positive leader tip and the ground, the processes that follow likely being similar to those in classical triggered lightning. Lightning appears to be able to reduce, via breakdown processes in the soil and on the ground surface, the grounding impedance which it initially encounters at the strike point, so at the time of channel-base current peak the reduced grounding impedance is always much lower than the equivalent impedance of the channel. At close ranges the measured M-component magnetic fields have waveshapes that are similar to those of the channel-base currents, whereas the measured M-component electric fields have waveforms that appear to be the time derivatives of the channel-base current waveforms, in further confirmation of the “two-wave” M-component mechanism.


Journal of Geophysical Research | 1999

Attachment process in rocket-triggered lightning strokes

Daohong Wang; Vladimir A. Rakov; Martin A. Uman; Nobuyuki Takagi; Teiji Watanabe; David E. Crawford; K. J. Rambo; G. H. Schnetzer; Richard J. Fisher; Z. Kawasaki

In order to study the lightning attachment process, we have obtained highly resolved (about 100 ns time resolution and about 3.6 m spatial resolution) optical images, electric field measurements, and channel-base current recordings for two dart leader/return-stroke sequences in two lightning flashes triggered using the rocket-and-wire technique at Camp Blanding, Florida. One of these two sequences exhibited an optically discernible upward-propagating discharge that occurred in response to the approaching downward-moving dart leader and connected to this descending leader. This observation provides the first direct evidence of the occurrence of upward connecting discharges in triggered lightning strokes, these strokes being similar to subsequent strokes in natural lightning. The observed upward connecting discharge had a light intensity one order of magnitude lower than its associated downward dart leader, a length of 7–11 m, and a duration of several hundred nanoseconds. The speed of the upward connecting discharge was estimated to be about 2 × 107 m/s, which is comparable to that of the downward dart leader. In both dart leader/return-stroke sequences studied, the return stroke was inferred to start at the point of junction between the downward dart leader and the upward connecting discharge and to propagate in both upward and downward directions. This latter inference provides indirect evidence of the occurrence of upward connecting discharges in both dart leader/return-stroke sequences even though one of these sequences did not have a discernible optical image of such a discharge. The length of the upward connecting discharges (observed in one case and inferred from the height of the return-stroke starting point in the other case) is greater for the event that is characterized by the larger leader electric field change and the higher return-stroke peak current. For the two dart leader/return-stroke sequences studied, the upward connecting discharge lengths are estimated to be 7–11 m and 4–7 m, with the corresponding return-stroke peak currents being 21 kA and 12 kA, and the corresponding leader electric field changes 30 m from the rocket launcher being 56 kV/m and 43 kV/m. Additionally, we note that the downward dart leader light pulse generally exhibits little variation in its 10–90% risetime and peak value over some tens of meters above the return-stroke starting point, while the following return-stroke light pulse shows an appreciable increase in risetime and a decrease in peak value while traversing the same section of the lightning channel. Our findings regarding (1) the initially bidirectional development of return-stroke process and (2) the relatively strong attenuation of the upward moving return-stroke light (and by inference current) pulse over the first some tens of meters of the channel may have important implications for return-stroke modeling.


Geophysical Research Letters | 2004

A ground level gamma-ray burst observed in association with rocket-triggered lightning

Joseph R. Dwyer; Hamid K. Rassoul; Maher Al-Dayeh; Lee Caraway; Brian D. Wright; A. Chrest; Martin A. Uman; Vladimir A. Rakov; K. J. Rambo; D. M. Jordan; J. Jerauld; C. Smyth

energetic radiation was observed at much earlier times, up to 160 ms before the return strokes. Because for such times, the dart leader tip must have been about 1000 m above the ground, it cannot be ruled out that for these events a gamma-ray (>1 MeV) component also originated from the cloud. [3] In this paper, we report an unusual event that occurred during the last rocket-triggered flash of the 2003 season. For this flash, an intense burst of MeV gamma-rays was observed from a distance of 650 m from the lightning channel, not in association with the dart leader or return stroke, but in association with a large current pulse (11 kA) occurring during the initial-stage (during the initial continuous current), about 20 ms after the vaporization of the triggering wire. In triggered lightning, the initial-stage is characterized by a steady current, preceding the return strokes, with superimposed pulses up to several kA in amplitude [Wang et al., 1999]. Considering the large distance of the detectors and the high energy of the gamma-rays, it is plausible that the burst originated in the cloud processes, perhaps many thousands of meters above the ground. This result may greatly facilitate the study of runaway breakdown of air inside thunderclouds [Gurevich et al., 1992], since it implies that observations of this phenomenon from the ground at sea level may be practical.


Journal of Geophysical Research | 1999

Characterization of the initial stage of negative rocket‐triggered lightning

Daohong Wang; Vladimir A. Rakov; Martin A. Uman; Mark I. Fernandez; K. J. Rambo; G. H. Schnetzer; Richard J. Fisher

We performed a statistical study on the initial stage (IS) of negative rocket-triggered lightning using 37 channel-base current recordings obtained during the summer of 1994 at Fort McClellan, Alabama, and during the summers of 1996 and 1997 at Camp Blanding, Florida. The IS can be viewed as composed of an upward positive leader (UPL) followed by an initial continuous current ( ICC ). The IS has a geometric mean (GM) duration of 279 ms and lowers a GM charge of 27 C to the ground. The average IS current in an individual lightning discharge varies from a minimum of 27 A to a maximum of 316 A with a GM value of 96 A for the entire sample of 37 discharges. We examined the current variation at the beginning of the IS in 24 flashes. In 22 out of 24 cases this initial current variation (ICV) includes a current drop, probably associated with the disintegration of the copper triggering wire and the subsequent current reestablishment. The GM time interval between the onset of the initial stage and the abrupt decrease in current is 8.6 ms, and the GM current level just prior to the current decrease is 312 A, a value about 3 times the GM value of average current for the whole IS, 96 A. Before this abrupt current decrease, a GM charge of 0.8 C has been lowered to ground with a corresponding GM action integral of 110 A2 s. The abrupt current decrease takes typically several hundred microseconds and is followed, immediately or after a time interval up to several hundred microseconds, by a pulse with a typical peak of about 1 kA and a typical risetime of less than 100 μs. The ICC usually includes impulsive processes that resemble the M processes observed during the continuing currents that follow return strokes in both natural and triggered lightning. We present statistics for the following parameters of current pulses superimposed on the ICC: magnitude, risetime, half-peak width, duration, charge transferred, preceding continuous current level, interpulse interval, and time interval between the onset of the IS and the first ICC pulse. The observed characteristics of ICC pulses varied significantly among the three data sets. For all data combined, the characteristics of the ICC pulses are similar to those of the M-component current pulses studied by Thottappillil et al [1995]. This latter finding suggests that ICC impulsive processes are of the same nature as M processes.


IEEE Transactions on Electromagnetic Compatibility | 2005

Lightning induced disturbances in buried cables - part II: experiment and model validation

Mario Paolone; E. Petrache; Farhad Rachidi; Carlo Alberto Nucci; Vladimir A. Rakov; Martin A. Uman; D. M. Jordan; K. J. Rambo; J. Jerauld; M. Nyffeler; J. Schoene

This paper presents experimental results obtained at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida during the summers of 2002 and 2003. Currents induced by triggered and natural lightning events were measured at the terminations of a buried power cable, in the cable shield, and in the inner cable conductor. Measurements of the horizontal component of the magnetic field above the ground surface for both natural and triggered lightning are also presented. For distant natural lightning events, locations of ground strike points were determined using the U.S. National Lightning Detection Network (NLDN). Based on the theoretical developments presented in Part I of this paper , the field-to-buried cable coupling equations are solved in both the time domain and in the frequency domain. The obtained experimental results are then used to validate the numerical simulations provided by the relevant developed codes.


Journal of Geophysical Research | 2001

The close lightning electromagnetic environment: Dart‐leader electric field change versus distance

David E. Crawford; Vladimir A. Rakov; Martin A. Uman; G. H. Schnetzer; K. J. Rambo; M. V. Stapleton; Richard J. Fisher

Net electric field changes due to dart leaders in triggered lightning from experiments conducted in 1997, 1998, and 1999 at the International Center for Lightning Research and Testing at Camp Blanding, Florida, are analyzed and compared with similar data obtained in 1993 at Camp Blanding and at Fort McClellan, Alabama. In 1997–1999 the fields were measured at 2–10 stations with distances from the lightning channel ranging from 10 to 621 m, while in 1993 the fields were measured at three distances, 30, 50, and 110 m, in Florida and at two distances, about 10 and 20 m, in Alabama. With a few exceptions, the 1997–1999 data indicate that the distance dependence of the leader electric field change is close to an inverse proportionality (r−1), in contrast to the 1993 data in which a somewhat weaker distance dependence was observed. The typically observed r−1 dependence is consistent with a uniform distribution of leader charge along the bottom kilometer or so of the channel.


IEEE Power & Energy Magazine | 2002

Direct Lightning Strikes to the Lightning Protective System of a Residential Building: Triggered-Lightning Experiments

Vladimir A. Rakov; Martin A. Uman; Mark I. Fernandez; Carlos T. Mata; K. J. Rambo; M. V. Stapleton; Rafael R. Sutil

Lightning triggered from natural thunderclouds using the rocket-and-wire technique was employed in order to subject to direct lightning strikes the lightning protective system of a test house at the Intemational Center for Lightning Research and Testing (ICLRT) at Camp Blending, Florida. The electrical circuit of the test house was connected to the secondary of a padmount distribution transformer located a distance of about 50 m from the house. The transformer primary was connected to a 650-m long unenergized underground power cable. The test house had two ground rods, one for the lightning protective system grounding and the other for the power supply system grounding. The two rods were about 3 m apart and were connected by a metallic cable. Lightning current was injected into the lightning protective system ground rod, and the currents and voltages at different points in the test system were measured. The waveshapes of currents in the ground rods of the test house differed markedly from the current waveshapes in other parts of the overall system. The ground rods at the test house appeared to filter out the higher-frequency components of the lightning current, allowing the lower-frequency components of the current to enter the houses electrical circuit; that is, the ground rods appeared to exhibit a capacitive behavior rather than the often expected resistive behavior. This effect was observed for dc grounding resistances of the rods (driven in sandy soil with conductivity of about 2.


Journal of Geophysical Research | 2000

Time derivative of the electric field 10, 14, and 30 m from triggered lightning strokes

Martin A. Uman; Vladimir A. Rakov; G. H. Schnetzer; K. J. Rambo; David E. Crawford; Richard J. Fisher

We have directly measured the time derivative of the electric field of triggered lightning strokes at distances of 10, 14, and 30 m. The data were taken in 1998 at the International Center for Lightning Research and Testing at Camp Blanding, Florida. We compare our results with those of similar triggered lightning measurements made previously at the Kennedy Space Center at distances of 50 m and 5 km and in France at 50 m. We also compare our electric field derivative waveforms with previous measurements at the Kennedy Space Center of natural lightning strokes over the Atlantic Ocean at distances of the order of tens of kilometers and with overland natural lightning data obtained at 0.7 to 14 km in Germany. Our return stroke electric field derivative peak values normalized (assuming the inverse distance dependence valid for radiation fields) to 100 km are similar to all previous measurements for both natural and triggered lightning at distances from 50 m to about 50 km, all being several tens of volts per meter per microsecond, with the exception of the German overland peak derivative values which are an order of magnitude lower. Our 10- to 30-m field derivative zero-to-peak risetimes are typically 50 to 100 ns (minimum of 30 ns and maximum of 180 ns), and widths at half-peak value are typically 100 to 200 ns. There is essentially no difference between our electric field derivative waveshapes measured simultaneously at 10 m and at 30 m, with the closer waveform being about a factor of 2 greater in amplitude. Fourier analysis of our electric field derivative waveforms indicates that the primary frequency content of the waveforms is below about 20 MHz. Our close return stroke field derivative waveforms differ from those of Leteinturier et al. (1990) recorded 50 m from triggered lightning at the Kennedy Space Center in 1985 in that their derivative waveforms typically decrease rapidly after the peak and exhibit zero crossings and in that their waveforms tend to have multiple peaks, while our derivative waveforms are generally single peaked and decay more gradually to zero after the peak, with no zero crossings. We argue that the differences between their waveforms and ours are related to the relatively large rocket-launching structure used at the Kennedy Space Center in 1985.


IEEE Transactions on Power Delivery | 2008

Distribution of Currents in the Lightning Protective System of a Residential Building—Part I: Triggered-Lightning Experiments

Brian A. DeCarlo; Vladimir A. Rakov; J. Jerauld; G. H. Schnetzer; J. Schoene; Martin A. Uman; K. J. Rambo; Venkateswararao Kodali; D. M. Jordan; Guy Maxwell; Stephen Humeniuk; Mark Morgan

We present the results of structural lightning protective system (LPS) tests conducted in 2004 and 2005 at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, FL. Lightning was triggered using the rocket-and- wire technique, and its current was directly injected into the LPS. The test configurations in 2004 and 2005 differed in the lightning current injection point, number of down conductors, grounding system at the test house, and the use of surge protective devices. The primary objective was to examine the division of the injected lightning current between the grounding system of the test house, and remote ground accessible via the neutral of the power-supply cable. In 2004, the mean value of the peak current entering the electrical circuit neutral in search of its way to remote ground was about 22% of the injected lightning current peak, while in 2005, it was about 59%. For comparison, more than 80% of the injected peak current was observed to enter the electrical circuit neutral in similar 1997 tests at the ICLRT in which a different test house with a different (poorer) grounding system was used (Rakov et al. 2002 [1]). An attempt to model the 2004 and 2005 experiments is presented in a companion paper.


IEEE Transactions on Electromagnetic Compatibility | 2004

Triggered lightning testing of an airport runway lighting system

Mirela Bejleri; Vladimir A. Rakov; Martin A. Uman; K. J. Rambo; Carlos T. Mata; Mark I. Fernandez

The interaction of rocket-triggered lightning with an airport runway lighting system has been studied. The lighting system included a buried counterpoise with attached vertical ground rods for protection of the series lighting cable from lightning. Experimental data for voltages and currents at various locations in the runway lighting system due to direct lightning strikes are presented along with the causative lightning current. The data include the first measurements of the responses of an underground bare conductor (counterpoise) to direct lightning strikes. These measurements can serve as ground truth for the testing of the validity of various counterpoise models.

Collaboration


Dive into the K. J. Rambo's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hamid K. Rassoul

Florida Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Brian D. Wright

Florida Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Lee Caraway

Florida Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Joseph R. Dwyer

University of New Hampshire

View shared research outputs
Researchain Logo
Decentralizing Knowledge