Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where K. Kawabe is active.

Publication


Featured researches published by K. Kawabe.


Optics Express | 2013

Squeezed quadrature fluctuations in a gravitational wave detector using squeezed light

S. E. Dwyer; L. Barsotti; S. Chua; M. Evans; M. Factourovich; D. Gustafson; T. Isogai; K. Kawabe; A. Khalaidovski; Ping Koy Lam; M. Landry; N. Mavalvala; D. E. McClelland; G. D. Meadors; C. M. Mow-Lowry; Roman Schnabel; R. Schofield; N. D. Smith-Lefebvre; M. Stefszky; C. Vorvick; D. Sigg

Squeezed states of light are an important tool for optical measurements below the shot noise limit and for optical realizations of quantum information systems. Recently, squeezed vacuum states were deployed to enhance the shot noise limited performance of gravitational wave detectors. In most practical implementations of squeezing enhancement, relative fluctuations between the squeezed quadrature angle and the measured quadrature (sometimes called squeezing angle jitter or phase noise) are one limit to the noise reduction that can be achieved. We present calculations of several effects that lead to quadrature fluctuations, and use these estimates to account for the observed quadrature fluctuations in a LIGO gravitational wave detector. We discuss the implications of this work for quantum enhanced advanced detectors and even more sensitive third generation detectors.


Classical and Quantum Gravity | 2014

Achieving resonance in the Advanced LIGO gravitational-wave interferometer

A. Staley; D. V. Martynov; R. Abbott; R. Adhikari; K. Arai; S. Ballmer; L. Barsotti; A. F. Brooks; R. T. Derosa; S. Dwyer; A. Effler; M. Evans; P. Fritschel; V. V. Frolov; C. Gray; C. Guido; R. Gustafson; M. C. Heintze; D. Hoak; K. Izumi; K. Kawabe; E. J. King; J. S. Kissel; K. Kokeyama; M. Landry; D. E. McClelland; J. Miller; A. Mullavey; B OʼReilly; J. G. Rollins

Interferometric gravitational-wave detectors are complex instruments comprised of a Michelson interferometer enhanced by multiple coupled cavities. Active feedback control is required to operate these instruments and keep the cavities locked on resonance. The optical response is highly nonlinear until a good operating point is reached. The linear operating range is between 0.01% and 1% of a fringe for each degree of freedom. The resonance lock has to be achieved in all five degrees of freedom simultaneously, making the acquisition difficult. Furthermore, the cavity linewidth seen by the laser is only _(~1) Hz, which is four orders of magnitude smaller than the linewidth of the free running laser. The arm length stabilization system is a new technique used for arm cavity locking in Advanced LIGO. Together with a modulation technique utilizing third harmonics to lock the central Michelson interferometer, the Advanced LIGO detector has been successfully locked and brought to an operating point where detecting gravitational-waves becomes feasible.


Classical and Quantum Gravity | 2014

Impact of backscattered light in a squeezing-enhanced interferometric gravitational-wave detector

S. Chua; S. E. Dwyer; L. Barsotti; D. Sigg; R. Schofield; V. V. Frolov; K. Kawabe; M. Evans; G. D. Meadors; M. Factourovich; R. Gustafson; N. D. Smith-Lefebvre; C. Vorvick; M. Landry; A. Khalaidovski; M. Stefszky; C. M. Mow-Lowry; Benjamin Buchler; Daniel A. Shaddock; Ping Koy Lam; Roman Schnabel; N. Mavalvala; D. E. McClelland

Squeezed states of light have been recently used to improve the sensitivity of laser-interferometric gravitational-wave detectors beyond the quantum limit. To completely establish quantum engineering as a realistic option for the next generation of detectors, it is crucial to study and quantify the noise coupling mechanisms which injection of squeezed states could potentially introduce. We present a direct measurement of the impact of backscattered light from a squeezed-light source deployed on one of the 4 km long detectors of the laser interferometric gravitational wave observatory (LIGO). We also show how our measurements inform the design of squeezed-light sources compatible with the


Gravitational wave and particle astrophysics detectors | 2004

The Status of GEO600

K. A. Strain; B. Allen; P. Aufmuth; C. Aulbert; S. Babak; R. Balasubramanian; B. Barr; Steven J. Berukoff; Alexander Bunkowski; G. Cagnoli; C. A. Cantley; M. M. Casey; S. Chelkowski; D. Churches; T. Cokelaer; C. N. Colacino; D. R. M. Crooks; Curt Cutler; Karsten Danzmann; R. Davies; R. J. Dupuis; E. J. Elliffe; Carsten Fallnich; A. Franzen; A. Freise; S. Gossler; A. Grant; H. Grote; S. Grunewald; J. Harms

The GEO 600 laser interferometer with 600m armlength is part of a worldwide network of gravitational wave detectors. GEO 600 is unique in having advanced multiple pendulum suspensions with a monolithic last stage and in employing a signal recycled optical design. This paper describes the recent commissioning of the interferometer and its operation in signal recycled mode.


GRAVITATIONAL WAVES: Third Edoardo Amaldi Conference | 2000

The status of GEO600

H. Lück; P. Aufmuth; Oliver Sascha Brozek; Karsten Danzmann; A. Freise; S. Goßler; A. Grado; H. Grote; K. Mossavi; V. Quetschke; B. Willke; K. Kawabe; Albrecht Rüdiger; R. Schilling; W. Winkler; Ch. Zhao; K. A. Strain; G. Cagnoli; M. M. Casey; J. Hough; M. E. Husman; P. W. McNamara; G. Newton; M. V. Plissi; N. A. Robertson; S. Rowan; D. I. Robertson; K. D. Skeldon; C. I. Torrie; H. Ward

GEO600, the German/British gravitational wave detector currently being built in northern Germany, used advanced optical technologies to obtain a sensitivity comparable with the other, bigger detectors currently being built [1,2]. The installation of the ultra-high-vacuum system has almost been completed and the Mode Cleaners are operational.


Optics Express | 2015

High precision optical cavity length and width measurements using double modulation

A. Staley; D. Hoak; A. Effler; K. Izumi; S. Dwyer; K. Kawabe; E. J. King; M. Rakhmanov; R. L. Savage; D. Sigg

We use doubly phase modulated light to measure both the length and the linewidth of an optical resonator with high precision. The first modulation is at RF frequencies and is set near a multiple of the free spectral range, whereas the second modulation is at audio frequencies to eliminate offset errors at DC. The light in transmission or in reflection of the optical resonator is demodulated while sweeping the RF frequency over the optical resonance. We derive expressions for the demodulated power in transmission, and show that the zero crossings of the demodulated signal in transmission serve as a precise measure of the cavity linewidth at half maximum intensity. We demonstrate the technique on two resonant cavities, with lengths 16 m and a 4 km, and achieve an absolute length accuracy as low as 70 ppb. The cavity width for the 16 m cavity was determined with an accuracy of approximately 6000 ppm. Through an analysis of the systematic errors we show that this result could be substantially improved with the reduction of technical sources of uncertainty.


Proceedings of SPIE - The International Society for Optical Engineering | 2004

The status of GEO 600

K. A. Strain; B. Allen; P. Aufmuth; C. Aulbert; S. Babak; R. Balasubramanian; B. Barr; S. J. Berukoff; Alexander Bunkowski; G. Cagnoli; C. A. Cantley; M. M. Casey; S. Chelkowski; D. Churches; T. Cokelaer; C. N. Colacino; D. R. M. Crooks; Curt Cutler; Karsten Danzmann; R. Davies; R. J. Dupuis; E. J. Elliffe; Carsten Fallnich; A. Franzen; A. Freise; S. Goßler; A. Grant; H. Grote; S. Grunewald; J. Harms

The GEO 600 laser interferometer with 600m armlength is part of a worldwide network of gravitational wave detectors. GEO 600 is unique in having advanced multiple pendulum suspensions with a monolithic last stage and in employing a signal recycled optical design. This paper describes the recent commissioning of the interferometer and its operation in signal recycled mode.


Astronomical Telescopes and Instrumentation | 2003

Status of the GEO600 gravitational wave detector

B. Willke; P. Aufmuth; C. Aulbert; S. Babak; R. Balasubramanian; B. Barr; Steven J. Berukoff; S. Bose; G. Cagnoli; M. M. Casey; D. Churches; C. N. Colacino; D. R. M. Crooks; Curt Cutler; Karsten Danzmann; R. Davies; R. J. Dupuis; E. J. Elliffe; Carsten Fallnich; A. Freise; S. Gossler; A. Grant; H. Grote; J. Harms; Gerhard Heinzel; S. Herden; A. Hepstonstall; M. Heurs; M. Hewitson; J. Hough

The GEO600 laser interferometric gravitational wave detector is approaching the end of its commissioning phase which started in 1995. During a test run in January 2002 the detector was operated for 15 days in a power-recycled michelson configuration. The detector and environmental data which were acquired during this test run were used to test the data analysis code. This paper describes the subsystems of GEO600, the status of the detector by August 2002 and the plans towards the first science run.

Collaboration


Dive into the K. Kawabe's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Freise

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

L. Barsotti

Massachusetts Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

M. Evans

Massachusetts Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

M. Landry

National Science Foundation

View shared research outputs
Top Co-Authors

Avatar

R. J. Dupuis

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge