K. Tay
Singapore General Hospital
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by K. Tay.
EJNMMI research | 2013
Yung-Hsiang Kao; Jeffrey D. Steinberg; Young-Soon Tay; Gabriel Ky Lim; Jianhua Yan; David W. Townsend; Charley A. Budgeon; Jan Boucek; Roslyn J. Francis; Timothy St Cheo; M.C. Burgmans; Farah G. Irani; R. Lo; K. Tay; B. Tan; Pierce Kh Chow; Somanesan Satchithanantham; Andrew Tan; David Ce Ng; Anthony Sw Goh
BackgroundCoincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated albumin (MAA) single-photon emission computed tomography with integrated CT (SPECT/CT) predictive dosimetry.MethodsRetrospective dose quantification of 90Y resin microspheres was performed on the same 23-patient data set in part 1. Phantom studies were performed to assure quantitative accuracy of our time-of-flight lutetium-yttrium-oxyorthosilicate system. Dose-responses were analyzed using 90Y dose-volume histograms (DVHs) by PET voxel dosimetry or mean absorbed doses by Medical Internal Radiation Dose macrodosimetry, correlated to follow-up imaging or clinical findings. Intended tumor mean doses by predictive dosimetry were compared to doses by 90Y PET.ResultsPhantom studies demonstrated near-perfect detector linearity and high tumor quantitative accuracy. For hepatocellular carcinomas, complete responses were generally achieved at D70 > 100 Gy (D70, minimum dose to 70% tumor volume), whereas incomplete responses were generally at D70 < 100 Gy; smaller tumors (<80 cm3) achieved D70 > 100 Gy more easily than larger tumors. There was complete response in a cholangiocarcinoma at D70 90 Gy and partial response in an adrenal gastrointestinal stromal tumor metastasis at D70 53 Gy. In two patients, a mean dose of 18 Gy to the stomach was asymptomatic, 49 Gy caused gastritis, 65 Gy caused ulceration, and 53 Gy caused duodenitis. In one patient, a bilateral kidney mean dose of 9 Gy (V20 8%) did not cause clinically relevant nephrotoxicity. Under near-ideal dosimetric conditions, there was excellent correlation between intended tumor mean doses by predictive dosimetry and those by 90Y PET, with a low median relative error of +3.8% (95% confidence interval, -1.2% to +13.2%).ConclusionsTumor and non-target tissue absorbed dose quantification by 90Y PET is accurate and yields radiobiologically meaningful dose-response information to guide adjuvant or mitigative action. Tumor 99mTc MAA SPECT/CT predictive dosimetry is feasible. 90Y DVHs may guide future techniques in predictive dosimetry.
Clinical Radiology | 2009
T.H. Teo; Yan Mee Law; K. Tay; B. Tan; Foong Koon Cheah
AIM To review and describe the magnetic resonance imaging (MRI) features in patients with suspected placental invasion and correlate the findings with surgery and pathology findings. MATERIALS AND METHODS A retrospective review was undertaken of the MRI images of seven consecutive patients with ultrasound findings suspicious for placental invasion. Two experienced MRI radiologists, blinded to the pathology and surgery findings, reviewed the MRI. The pathology or surgical findings were used as the reference standard to establish accuracy and concordance with the MRI findings. RESULTS Three MRI features described in an earlier series were consistently present in the patients with placental invasion: lower uterine bulging, heterogeneous placenta, and dark intraplacental linear bands on T2-weighted images. CONCLUSION MRI features, which were described in patients with placental invasion in an earlier series, were useful in establishing the presence and depth of placental invasion.
PLOS ONE | 2014
Pierce K. H. Chow; Donald Poon; Maung-Win Khin; Harjit Singh; Ho-Seong Han; Anthony Goh; Su-Pin Choo; Hee-Kit Lai; Richard Hoau Gong Lo; K. Tay; Teong-Guan Lim; Mihir Gandhi; Say Beng Tan; Khee Chee Soo
Background The safety and tolerability of sequential radioembolization-sorafenib therapy is unknown. An open-label, single arm, investigator-initiated Phase II study (NCT0071279) was conducted at four Asia-Pacific centers to evaluate the safety and efficacy of sequential radioembolization-sorafenib in patients with hepatocellular carcinoma (HCC) not amenable to curative therapies. Methods Sorafenib (400 mg twice-daily) was initiated 14 days post-radioembolization with yttrium-90 (90Y) resin microspheres given as a single procedure. The primary endpoints were safety and tolerability and best overall response rate (ORR) using RECIST v1.0.Secondary endpoints included: disease control rate (complete [CR] plus partial responses [PR] and stable disease [SD]) and overall survival (OS). Results Twenty-nine patients with Barcelona Clinic Liver Cancer (BCLC) stage B (38%) or C (62%) HCC received a median of 3.0 GBq (interquartile range, 1.0) 90Y-microspheres followed by sorafenib (median dose/day, 600.0 mg; median duration, 4.1 months). Twenty eight patients experienced ≥1 toxicity; 15 (52%) grade ≥3. Best ORR was 25%, including 2 (7%) CR and 5 (18%) PR, and 15 (54%) SD. Disease control was 100% and 65% in BCLC stage B and C, respectively. Two patients (7%) had sufficient response to enable radical therapy. Median survivals for BCLC stage B and C were 20.3 and 8.6 months, respectively. Conclusions This study shows the potential efficacy and manageable toxicity of sequential radioembolization-sorafenib. Trial Registration ClinicalTrials.gov NCT00712790.
BJUI | 2010
Christopher M. Chick; B. Tan; Christopher Cheng; Manish Taneja; Richard Lo; Yeh-Hong Tan; Shueh-En Lin; K. Tay
Study Type – Therapy (case series) Level of Evidence 4
EJNMMI research | 2013
Yung-Hsiang Kao; Jeffrey D. Steinberg; Young-Soon Tay; Gabriel Ky Lim; Jianhua Yan; David W. Townsend; Angela Takano; M.C. Burgmans; Farah G. Irani; Terence Kb Teo; Tow-Non Yeow; Apoorva Gogna; R. Lo; K. Tay; B. Tan; Pierce Kh Chow; Somanesan Satchithanantham; Andrew Tan; David Ce Ng; Anthony Sw Goh
BackgroundYttrium-90 (90Y) positron emission tomography with integrated computed tomography (PET/CT) represents a technological leap from 90Y bremsstrahlung single-photon emission computed tomography with integrated computed tomography (SPECT/CT) by coincidence imaging of low abundance internal pair production. Encouraged by favorable early experiences, we implemented post-radioembolization 90Y PET/CT as an adjunct to 90Y bremsstrahlung SPECT/CT in diagnostic reporting.MethodsThis is a retrospective review of all paired 90Y PET/CT and 90Y bremsstrahlung SPECT/CT scans over a 1-year period. We compared image resolution, ability to confirm technical success, detection of non-target activity, and providing conclusive information about 90Y activity within targeted tumor vascular thrombosis. 90Y resin microspheres were used. 90Y PET/CT was performed on a conventional time-of-flight lutetium-yttrium-oxyorthosilicate scanner with minor modifications to acquisition and reconstruction parameters. Specific findings on 90Y PET/CT were corroborated by 90Y bremsstrahlung SPECT/CT, 99mTc macroaggregated albumin SPECT/CT, follow-up diagnostic imaging or review of clinical records.ResultsDiagnostic reporting recommendations were developed from our collective experience across 44 paired scans. Emphasis on the continuity of care improved overall diagnostic accuracy and reporting confidence of the operator. With proper technique, the presence of background noise did not pose a problem for diagnostic reporting. A counter-intuitive but effective technique of detecting non-target activity is proposed, based on the pattern of activity and its relation to underlying anatomy, instead of its visual intensity. In a sub-analysis of 23 patients with a median follow-up of 5.4 months, 90Y PET/CT consistently outperformed 90Y bremsstrahlung SPECT/CT in all aspects of qualitative analysis, including assessment for non-target activity and tumor vascular thrombosis. Parts of viscera closely adjacent to the liver remain challenging for non-target activity detection, compounded by a tendency for mis-registration.ConclusionsAdherence to proper diagnostic reporting technique and emphasis on continuity of care are vital to the clinical utility of post-radioembolization 90Y PET/CT. 90Y PET/CT is superior to 90Y bremsstrahlung SPECT/CT for the assessment of target and non-target activity.
CardioVascular and Interventional Radiology | 2011
Gopinathan Anil; K. Tay; Tse-Chiang Howe; B. Tan
This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affected in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available “one-stop–shop” imaging modality in the management of PAES.
Anz Journal of Surgery | 2005
Brian K. P. Goh; K. Tay; S. Tan
Background: The purpose of the present study was to report the authors’ experience of surgically treating eight limbs in six patients for popliteal artery entrapment syndrome (PAES), over a 10‐year period.
European Journal of Radiology | 2012
M.C. Burgmans; Chow Wei Too; Yung-Hsiang Kao; Anthony Sw Goh; Pierce K. H. Chow; B. Tan; K. Tay; R. Lo
PURPOSE To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. MATERIAL AND METHODS From August 2008 to November 2010, 79 patients (range 23-83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. RESULTS A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p<0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. CONCLUSION The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.
EJVES Short Reports | 2018
Darius Kang Lie Aw; Hao-Yun Yap; Luke H.T. Tay; K. Tay; Tze-Tec Chong
Introduction In general, arteriovenous malformations (AVMs) are extremely rare, with an incidence of only 1 in 100,000. They are rarer still in the hands and present variably with bleeding, heaviness, a pulsatile mass, pain, ulceration, or necrosis. Report The case of a 25 year old man with a rapidly bleeding right thumb AVM is presented. Bleeding was torrential and life threatening within a matter of seconds. He had previously undergone surgical ligation and embolisation twice at another centre, without success. At presentation, he had no thumb function and the bones of the thumb were exposed. An angio-embolisation was performed with ethanol and cyanoacrylate as the embolic agent. This was done using direct puncture into the AVM and also with a transarterial approach with microcatheters inserted into various unnamed branches feeding the AVM. Non-target embolisation and reflux was prevented by deploying a pneumatic tourniquet and mechanical elastic bands to confine the flow of the embolic agents within the AVM. Re-aspiration of the embolic agent post-embolisation was also performed to prevent local/systemic ethanol toxicity. Haemostasis was achieved without the need for further compression. A right thumb disarticulation was subsequently performed and the patient expressed great satisfaction with the outcome. Discussion AVMs in the hand are particularly challenging to treat owing to the need to preserve function of the myriad tissues and structural units that enable the many hand movements involved in activities of daily living. Even a partial loss of function may be disabling or poorly tolerated. The mainstays of treatment are embolisation, sclerotherapy, and surgical ligation/resection, all of which carry the potential for ischaemic injury to muscle and soft tissue. A holistic approach to management is desirable prior to selecting the appropriate management plan.
Archive | 2012
Bien-Soo Tan; Lynette Li San Teo; Daniel E. S. Wong; Shaun X. J. M. Chan; K. Tay
The diagnostic radiology training system in Singapore has evolved from our British colonial past, which has influenced both education and health care. A brief history of diagnostic radiology training is covered followed by a description of the current training system. The training assessment process has been shaped by the hierarchical structure of our organizations and by our Asian background. The current assessment tools, for the trainee as well as of the trainers, are detailed in this chapter. As the training system has been incrementally improved and become more structured, the assessment processes have also been adjusted, and additional tools have been introduced.