Journal of Clinical Pathology | 2006

Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring.

Luke Bereznicki; Sl Jackson; Gm Peterson; Ec Jeffrey; Ka Marsden; David Jupe

Aim: To evaluate the accuracy of the CoaguChek XS international normalised ratio (INR) monitor compared with the laboratory method. Methods: The accuracy and ease of use of the recently marketed CoaguChek XS portable INR monitor was evaluated in 17 patients involved in a trial of warfarin home monitoring. INR results from the monitor were compared with those from the laboratory method. Clinical applicability was measured by discrepant INR values, defined in the literature by expanded and narrow agreement criteria, and by the proportion of INR values differing by >15% and by >20% from those derived by the laboratory method. Results: Participants provided 59 comparison INR measurements for analysis. The paired results were highly correlated (r = 0.91). Expanded and narrow agreement between paired INR values occurred 100% of the time. Only three CoaguChek XS (5.1%) results differed by >15% compared with the laboratory method; no results differed by >20% or were discrepant by >0.5 INR units. Conclusions: In the hands of patients the CoaguChek XS showed good correlation with laboratory determination of INR and compared well with expanded and narrow clinical agreement criteria. Both patients and doctors were highly satisfied with the accuracy and ease of use of the CoaguChek XS.


Thrombosis and Haemostasis | 2006

Identification of factor inhibitors by diagnostic haemostasis laboratories. A large multi-centre evaluation

Emmanuel J. Favaloro; Roslyn Bonar; Elizabeth Duncan; Gail Earl; Joyce Low; Margaret Aboud; Sarah Just; John Sioufi; Alison Street; Ka Marsden

We have assessed the proficiency of diagnostic haemostasis facilities to correctly identify coagulation factor abnormalities and inhibitors. Forty-two laboratories participating in the external Quality Assurance Program (QAP) conducted by the RCPA agreed to participate and were each sent a set of eight samples (each 3 x 1 ml) for evaluation. They were asked to blind test these samples for the presence or absence of inhibitors, and where identified, to perform further analysis (including specific inhibitor analysis). In order to make the exercise more challenging, in addition to true factor inhibitors, samples were provided that reflected potential pre-analytical variables that might arise and complicate inhibitor detection or lead to false inhibitor identification. In brief, the sample set comprised a true high level factor (F) V inhibitor, a true moderate level FVIII inhibitor (but sample was defibrinogenated), a true lupus anticoagulant (LA), a normal (but slightly aged) plasma sample, a normal serum sample, a normal EDTA sample, an oral anticoagulant/vitamin K deficiency sample, and a gross heparin ( approximately 10 U/ml) contaminated sample. Sixty-three percent of participants correctly identified the true FV inhibitor as such, although the reported range varied greatly [10 to >250 Bethesda units (BU/ml)] and 46% correctly identified the true FVIII inhibitor, despite the complication of the sample presentation, although the reported range also varied (7 to 64 BU/ml). Some laboratories either failed to identify the inhibitor present, or misidentified the inhibitor type. The LA, the oral anticoagulant/vitamin K deficiency, the normal serum sample, and the normal (aged) sample were also correctly identified by most laboratories, as was the absence of specific factor inhibitors in these samples. However, a small subset of laboratories incorrectly identified the presence of specific factor inhibitors in some of these samples. The heparin sample was also correctly identified by most (68%) laboratories. In contrast, the normal EDTA sample was misidentified as a FV and/or FVIII inhibitor by most (68%) laboratories, and only one laboratory correctly identified this as an EDTA sample. Thus, we conclude that although laboratories are able, in most cases, to identify the presence of true factor inhibitors, there is a large variation in identified inhibitor levels and there are also some significant errors in identification (i.e. false negatives and misidentifications). In addition, there is a significant false positive error rate where some laboratories will identify the presence of specific factor inhibitors where no such inhibitor exists (i.e. false positives).


Haemophilia | 2004

Laboratory diagnosis of von Willebrand's disorder: quality and diagnostic improvements driven by peer review in a multilaboratory test process.

Emmanuel J. Favaloro; Roslyn Bonar; G Kershaw; John Sioufi; Mark Hertzberg; A Street; John Lloyd; Ka Marsden

Summary.  Regular multilaboratory surveys of laboratories derived primarily from Australia, New Zealand and Southeast Asia have been conducted over the past 7 years to evaluate testing proficiency in the diagnosis of von Willebrands disorder (VWD) and to assess changes to test practice. Participating laboratories (currently 45) are asked to perform their usual panel of tests for VWD, and then to self‐interpret test results as to the likelihood (or not) of VWD, as well as to the potential subtype identified. Samples provided in the past two survey distributions (both conducted in 2003) were as follows. Survey part A/distribution 1: Normal donor plasma, plasma with borderline normal/reduced levels of VWF (×2) and plasma from an individual with type 2 A VWD. Survey part B/distribution 2 (family VWD study): Plasma from a father, mother and son with borderline normal/reduced von Willebrand factor (VWF), and a daughter with type 3 VWD. In line with previously published survey results, the interassay and within method coefficients of variation (CV) were similar for all assays (around 15–25%), although tending to be slightly higher for VWF:RCo and VWF:CB than VWF:Ag and FVIII:C. Most laboratories reported test values consistent with expected findings, and made correct interpretations or predictions regarding the nature of the samples, although discrepant assay results or interpretations are still seen in approximately 5–10% of responses (typically from laboratories using a more limited test panel or not performing the VWF:CB). Overall, problems with the non‐identification of functional VWF discordance in type 2 VWD, the misidentification of functional VWF discordance in type 1 VWD, and difficulties in discriminating types 1 and 3 VWD appear to predominate. In comparison with previous surveys, performance of electro‐immuno diffusion (EID) (or Laurel gel) procedures has now ceased, and a reduction in VWF:RCo and VWF:Multimer testing and an increase in latex immunoassay (LIA) testing is sustained. We conclude that laboratories are generally proficient in tests for VWD, and that diagnostic error rates are reduced when test panels are more comprehensive and include the VWF:CB.


Pathology | 2015

The effect of dabigatran on haemostasis tests: a comprehensive assessment using in vitro and ex vivo samples

Roslyn Bonar; Emmanuel J. Favaloro; Soma Mohammed; Leonardo Pasalic; John Sioufi; Ka Marsden

Summary The new direct oral anticoagulants (DOACS) dabigatran, rivaroxaban, apixaban and edoxaban provide alternatives to warfarin for treatment and prevention of atrial fibrillation and venous thromboembolic disease in various settings. These have been developed as not requiring laboratory monitoring; however, under certain clinical situations, including recent haemorrhage/thrombosis, emergency surgical procedures, testing may be indicated. The aim of this study was to assess findings of haemostasis laboratory tests for one of the DOACs, dabigatran (Pradaxa), tested across a wide range of laboratory assays. Laboratories (n = 72) enrolled in the Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP) Haematology program were sent set(s) of seven dabigatran spiked plasma samples covering the concentration 0–800 ng/mL. Also, 30 ex vivo patient samples under therapy with dabigatran were assessed. Prothrombin time and activated partial thromboplastin time assays showed some sensitivity to dabigatran; however, a normal result could not inform on drug exclusion. The thrombin time (TT) was very sensitive to dabigatran, and a normal TT could generally be used for drug exclusion. More specialised assays such as the Hemoclot, a direct thrombin inhibition assay, and in-house dilute TT methods, showed good reproducibility and concordance with expected drug levels assessed by mass spectrometry and were effective to quantify drug levels. Dabigatran also affected factor assays, lupus anticoagulant and factor inhibitor measurement, leading to potential misinterpretation of test results. Ex vivo sample testing provided similar and extended information. Dabigatran affects many haemostasis tests. Some can be used to predict the presence, absence or quantity of dabigatran in patient plasma. For others, interference may lead to false conclusions regarding patients’ haemostatic status.


Seminars in Thrombosis and Hemostasis | 2009

Investigations from External Quality Assurance Programs Reveal a High Degree of Variation in the Laboratory Identification of Coagulation Factor Inhibitors

Emmanuel J. Favaloro; Roslyn Bonar; Geoffrey Kershaw; Elizabeth Duncan; John Sioufi; Ka Marsden

The laboratory has a key role in the initial detection of factor inhibitors and an ongoing role in the measurement of inhibitor titers during the course of inhibitor eradication therapy. The most commonly seen factor inhibitors are those directed against factor VIII (FVIII), usually detected either with the original or the Nijmegen-modified Bethesda assay. In addition, several circumstances can arise in which the laboratory may test samples that potentially reflect false identification of factor inhibitors. These include lupus anticoagulants and other events generally related to preanalytical variables, including incorrect sample presentations. This article reviews each of these elements, largely from the perspective of cross-laboratory studies undertaken within the framework of external quality assurance (EQA), a peer-laboratory process that aims to assess the ongoing performance of groups of similar laboratories. This review details the experience of the Royal College of Pathologists of Australasia Haematology Quality Assurance Program, and it also reflects on the experience of other EQA organizations. Our analysis reveals a wide variety of test practice among inhibitor testing laboratories, a wide variation in detected inhibitor levels in cross-tested samples, and substantial evidence of false-positive and false-negative detection of factor inhibitors. These findings hold some significance for the clinical management of patients affected by these inhibitors. There is still much need for standardization and improvement in factor inhibitor detection, and we hope that this report provides a basis for future improvements in this area.


American Journal of Clinical Pathology | 2003

Laboratory diagnosis of von Willebrand disorder. Current practice in the southern hemisphere.

Emmanuel J. Favaloro; Roslyn Bonar; John Sioufi; Mark Hertzberg; Alison Street; John Lloyd; Ka Marsden

A survey of 44 laboratories was conducted to evaluate current testing proficiency in the diagnosis of von Willebrand disorder (vWD) and to assess recent changes in test practices. Laboratories performed their usual panel of tests for vWD and interpreted results for the likelihood of vWD and potential subtype. Samples were as follows: normal plasma; borderline normal or abnormal levels of von Willebrand factor (vWF) and factor VIII; type 3 vWD; type 2A vWD; and 2 samples from a healthy person, processed after handling at 22°C and 4°C, respectively. Interassay and within-method coefficients of variation were similar for all assays (approximately 15%–25%). Most laboratories reported test values consistent with expected findings and made correct interpretations, although discrepant results for 5% to 10% of responses are of concern. For the sample stored at 4°C, all laboratories detected low or borderline levels of vWF and factor VIII coagulant, and no laboratory identified this sample as from a healthy person. In contrast, for the sample stored at 22°C, most laboratories reported normal results. Compared with previous results, performance of some assays has declined while that of others has increased. Laboratories generally are proficient in tests for vWD, and transport of samples at 4°C before processing may lead to false identification of vWD, suggesting that NCCLS guidelines should be reviewed.


Haemophilia | 2016

Type 2M von Willebrand disease - more often misidentified than correctly identified.

Emmanuel J. Favaloro; Roslyn Bonar; Soma Mohammed; Alejandro Arbelaez; Johan Niemann; R. Freney; Muriel Meiring; John Sioufi; Ka Marsden

Appropriate diagnosis of von Willebrand disease (VWD), including differential identification of qualitative vs. quantitative von Willebrand factor (VWF) defects has important management implications, but remains problematic.


Leukemia & Lymphoma | 2001

Pathologic Splenic Rupture as the Presentation of Mantle Cell Lymphoma

A. H. Strickland; Ka Marsden; J Mcardle; Rm Lowenthal

Pathologic splenic rupture in non-Hodgkins lymphoma (NHL) is a rare event, with 32 cases previously reported. Initial presentation of NHL with this complication is even rarer. We report such a case in an 80-year-old man with mantle cell lymphoma (MCL). It is notable that of the previously reported cases of pathologic rupture, three have occurred in MCL, suggesting that patients with this uncommon subtype of NHL may be particularly vulnerable to pathologic splenic rupture. Following splenectomy the patients disease behaved in a high-grade fashion. Despite an initially encouraging response, his disease ran an aggressive course and he succumbed within four months. This case demonstrates the presentation of MCL with pathologic splenic rupture, as well as the potentially highly malignant behaviour of the disease.


Seminars in Thrombosis and Hemostasis | 2013

External quality assessment of factor VIII inhibitor assays

Roslyn Bonar; Emmanuel J. Favaloro; Ka Marsden

Inhibitors to coagulation factors cause prolongation of routine hemostasis laboratory test results and have clinical relevance in the management of congenital and acquired hemophilia patients. Factor VIII (FVIII) inhibitors can be either allo-antibodies (in hemophilia A) or auto-antibodies (in acquired hemophilia) directed against FVIII. The most commonly used assays for detecting these inhibitors are the classical Bethesda assay or a modified (Nijmegen) method. Previous laboratory assessments from the Royal College of Pathologists of Australia Quality Assurance Program (RCPAQAP) Haematology and other external quality assessment programs have shown wide variability in FVIII inhibitor results and method performance, as well as a significant degree of false-positive and false-negative interpretations. Despite its limitations, the Bethesda assay is still the primary assay used in laboratories for detecting the presence and strength of a FVIII inhibitor. Therefore, it is of utmost importance that this assay is performed well. The current report reviews the most recent findings from the RCPAQAP Haematology, which show there is still a need for better standardization and improvement in the detection of low-level FVIII inhibitors to ultimately provide better clinical management of affected patients.


Blood | 2011

Anticipation in familial hematologic malignancies

E Tegg; Russell Thomson; Jim Stankovich; A Banks; Ka Marsden; Rm Lowenthal; Simon J. Foote; Joanne L. Dickinson

We describe a collection of 11 families with ≥ 2 generations of family members whose condition has been diagnosed as a hematologic malignancy. In 9 of these families there was a significant decrease in age at diagnosis in each subsequent generation (anticipation). The mean age at diagnosis in the first generation was 67.8 years, 57.1 years in the second, and 41.8 years in the third (P < .0002). This was confirmed in both direct parent-offspring pairs with a mean reduction of 19 years in the age at diagnosis (P = .0087) and when the analysis was repeated only including cases of mature B-cell neoplasm (P = .0007). We believe that these families provide further insight into the nature of the underlying genetic mechanism of predisposition in these families.

Collaboration


Dive into the Ka Marsden's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

E Tegg

Royal Hobart Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sl Jackson

University of Tasmania

View shared research outputs
Top Co-Authors

Avatar

Gm Peterson

University of Tasmania

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Simon J. Foote

Australian National University

View shared research outputs
Top Co-Authors

Avatar

A Banks

Menzies Research Institute

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge