Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kaoru Myouchin is active.

Publication


Featured researches published by Kaoru Myouchin.


Journal of Computer Assisted Tomography | 2011

Usefulness of contrast-enhanced magnetic resonance angiography for follow-up of coil embolization with the enterprise stent for cerebral aneurysms.

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

Objective: The aim of this study was to determine the feasibility and usefulness of contrast-enhanced magnetic resonance angiography (CE-MRA) and 3-dimensional (3D) time-of-flight (TOF) MRA for follow-up of intracranial aneurysms treated using the Enterprise stent. Methods: Five aneurysm cases using the Enterprise stent were prospectively analyzed and were followed up with CE-MRA, 3D TOF MRA, and digital subtraction angiography (DSA). Depictions of parent artery lumen and the aneurysm neck with 3D TOF MRA and CE-MRA were compared with those of DSA. Results: In all cases, on 3D TOF MRA, it was difficult to evaluate the parent artery lumen and aneurysm neck owing to the significant artifacts from the stent. Contrast-enhanced MRA sufficiently demonstrated parent artery lumen and aneurysm neck distinctly and as clear as DSA did in all cases. Conclusions: For follow-up after coiling with an Enterprise stent, CE-MRA may be necessary to avoid susceptibility artifacts caused by the stent.


American Journal of Neuroradiology | 2012

Effect of Cilostazol in Preventing Restenosis after Carotid Artery Stenting Using the Carotid Wallstent: A Multicenter Retrospective Study

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Kinya Furuichi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

BACKGROUND AND PURPOSE: Restenosis after CAS is a postoperative problem, with a reported frequency of approximately 2%–8%. However differences in stent design, procedure, and the antiplatelet agent appear to affect the incidence of restenosis. We assessed the frequency of restenosis and the effect of the antiplatelet agent CLZ in preventing restenosis after CAS by the standard procedure using the CWS. MATERIALS AND METHODS: Between May 2010 and October 2011, 62 lesions in 60 consecutive patients underwent CAS using the CWS at 4 medical institutions, and all patients were followed clinically and assessed by sonography, 3D-CTA, or angiography at 3 and 6 months postoperatively. Restenosis was defined as ≥50% stenosis. The incidence of restenosis and the variation in the incidence of restenosis by the difference in type of antiplatelet agent between the CLZ group (n = 30; aspirin, 100 mg, and CLZ, 200 mg) and the non-CLZ group (n = 32; aspirin, 100 mg, and clopidogrel, 75 mg [n = 29]; or ticlopidine, 100 mg [n = 2] or 200 mg [n = 1]) were retrospectively investigated. Two antiplatelet agents were given starting 1 week preoperatively until at least 3 months postoperatively. RESULTS: Restenosis occurred in 5 patients (8.3%), but all were cases of asymptomatic lesions in the follow-up period. All 5 patients with restenosis were in the non-CLZ group, with no cases of restenosis in the CLZ group; the difference was significant (P = .0239). CONCLUSIONS: The restenosis rate after CAS by using the CWS was 8.3%. CLZ was associated with significant inhibition of restenosis.


Radiation Medicine | 2008

Initial experience of using the filter protection device during carotid artery stenting in Japan

Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Toshiteru Miyasaka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Ichiro Nakagawa; Shinichiro Kurokawa; Kimihiko Kichikawa

Purpose No filter protection devices for carotid artery stenting (CAS) have been formally approved for use in Japan; however, as of April 2008, the Angioguard XP (AGXP) was approved. This article describes our initial results using the AGXP during CAS for the treatment of carotid artery stenosis.


Radiation Medicine | 2007

Successful percutaneous transluminal angioplasty and stenting for symptomatic intracranial vertebral artery stenosis using intravascular ultrasound virtual histology

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

This is the first report of percutaneous transluminal angioplasty (PTA) of an intracranial artery applying intravascular ultrasound virtual histology (IVUS-VH), which has been recently developed for tissue characterization of coronary artery plaque. We report a case of successful PTA and stenting for symptomatic intracranial vertebral artery stenosis using IVUS-VH.


Rivista Di Neuroradiologia | 2014

Long-Term Treatment Outcomes after Intravascular Ultrasound Evaluation and Stent Placement for Atherosclerotic Subclavian Artery Obstructive Lesions

Takeshi Wada; Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Toshiteru Miyasaka; Toshiaki Akashi; Masahiko Sakamoto; Kimihiko Kichikawa

The objective of this study was to determine long-term outcomes after stent placement for subclavian artery (SA) obstructive lesions assisted by intraoperative intravascular ultrasound (IVUS). The study included 25 lesions in 24 patients who underwent stent placement assisted by intraoperative IVUS for subclavian artery stenosis or obstruction at our hospital between January 2003 and August 2010. Outcome was evaluated based on the results within 30 postoperative days (technical success rate, improvement in upper extremity ischemia, steal syndrome, left-right blood pressure difference, and perioperative complications) and the results after 30 postoperative days (incidence of vertebrobasilar artery territory infarction and restenosis). Stent placement and vessel dilatation were successful in all patients, without perioperative complications. Upper extremity ischemia, steal syndrome, and left-right blood pressure difference disappeared in all cases. During follow-up observation (6–96 months; median 51 months), no restenosis occurred at the stent placement site in any patient. In one case, four years after initial treatment, stenosis was noted proximal to the stent placement site. Satisfactory long-term as well as short-term outcomes were achieved after stent placement for SA obstructive lesions assisted by intraoperative IVUS evaluation.Innovations in endovascular tools have permitted an increasingly broad range of neurovascular lesions to be treated via minimally invasive methods. However, some device modifications may carry additional risks, not immediately apparent to operators. A patient with a symptomatic, partially thrombosed basilar apex aneurysm was allocated balloon-assisted coiling. Attempts were made to place a microwire across the basilar apex through the posterior communicating artery. Overlapping courses of the posterior cerebral and posterior choroidal arteries on the roadmap images were not recognized and a flanged-tip microwire was inadvertently advanced deep into the choroidal artery. Following the wire with a microcatheter led to binding of arterial tissue within the microcatheter. Removing the wire led to an avulsion of the choroidal artery and a severe hemorrhagic complication which proved fatal. Tissue was identified on the tip of the guidewire. Pathology showed layers of vascular tissue within the laser-cut flanges of the distal wire tip. A similar complication, also fatal, occurred during balloon angioplasty of a distal vertebral artery, when an exchange wire was accidently introduced into a perforator from a posterior cerebral artery. Ex vivo catheterization of distal mesenteric arterial branches showed that the wall of small arteries can be entrapped by laser-cut, flanged, but not by smooth guidewire tips. Microwires with a flanged instead of smooth distal tip, when placed into small caliber vessels, may cause hemorrhagic complications from avulsions*.


Japanese Journal of Radiology | 2011

Initial experience of carotid artery stenting using the Carotid WALLSTENT and FilterWire EZ in Japan.

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Toshiteru Miyasaka; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Ryota Kimura; Shinichiro Kurokawa; Kimihiko Kichikawa

PurposeThe Carotid WALLSTENT (CWS) and Filter-Wire EZ (FWEZ) embolic protection devices for use in carotid arterial stenting (CAS) were newly approved for national health insurance coverage in Japan in April 2010. This article describes our initial experience of CAS using the CWS and FWEZ.Material and methodsA group of 14 patients (12 men, 2 women; mean age 70.1 years, range 59–83 years) with 15 carotid artery stenoses at high risk for carotid endarterectomy were treated by CAS using the CWS and FWEZ. Of these stenoses, 5 were symptomatic with ≥50% stenosis of the common or internal carotid artery (ICA), and 10 were asymptomatic with ≥80% stenosis. The rates of technical success, ICA flow impairment during filter protection, periprocedural ischemic stroke, 30-day major adverse events (MAEs) (stroke, death, myocardial infarction), and development of new ischemic lesions on diffusion-weighted imaging (DWI) were assessed.ResultsCAS was successful in all cases. There was no ICA flow impairment, periprocedural ischemic stroke, or MAEs. DWI showed new ipsilateral ischemic lesions in only one patient (6.7%).ConclusionOur initial clinical experience using the CWS and FEWZ for CAS was generally excellent, and the incidence of postprocedural ischemic lesions was low.


SpringerPlus | 2013

Carotid Wallstent placement difficulties encountered in carotid artery stenting

Kaoru Myouchin; Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Takeshi Wada; Masahiko Sakamoto; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

PurposeThe present study aimed to identify the types of curved lesions that are difficult to place Carotid Wallstent (CWS).Materials and methodsThe study targeted 31 consecutive carotid artery (CA) stenosis underwent carotid artery stenting using CWS. CWS placement success rate, stenosis location, lesion tortuosity, and relationship with stent placement failures were investigated. Lesion tortuosity was defined as the angle formed by 2 tangential lines between internal CA and common CA from the inflection point (IP) was defined as the center of lesion curvature. Stenosed lesions were classified into type A or B. Type A was defined as if the distal end of the stenosis was located proximal to the IP at a distance ≥0.5 of a vertebral body based on the posterior height of the 3rd vertebral body, otherwise was type B.ResultsThe stent placement success rate was 93.5% (29/31). The 2 unsuccessfully stented lesions, both lesions were significantly different from other lesions by having a lesion tortuosity less than 90° and by belonging to type B.ConclusionSince CWS placement is difficult in patients with CA stenosis located close to the IP at a lesion tortuosity ≤90°, open-cell stents should be considered as an alternative.


Radiation Medicine | 2008

Multiple cerebral aneurysms associated with Takayasu arteritis successfully treated with coil embolization

Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Shinichiro Kurokawa; Kimihiko Kichikawa

The cerebrovascular complications of Takayasu arteritis are primarily related to the presence of occlusive lesions. Cerebral aneurysms rarely occur as complications; only 18 cases have been reported thus far. The use of coil embolization to treat cerebral aneurysms occurring as a complication of Takayasu arteritis has not been previously reported. We report a case of Takayasu arteritis with a basilar tip aneurysm and a P1 segment aneurysm of the left posterior cerebral artery that were successfully treated with coil embolization. Because coil embolization for cerebral aneurysms associated with Takayasu arteritis requires the use of limited access routes that have extremely curved and tortuous courses, catheter navigation was difficult. The guide catheter, microcatheter, and guidewire must be selected and navigated with greater care than is usually required for common aneurysm embolization.


Radiation Medicine | 2007

Cerebral hemorrhage with angiographic extravasation immediately after carotid artery stenting

Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Takeshi Wada; Kaoru Myouchin; Masahiko Sakamoto; Akio Fukusumi; Kimihiko Kichikawa

Recognizing cerebral hyperperfusion syndrome with intracerebral hemorrhage following carotid artery stenting is critical because the mortality rate is high. This type of hemorrhage usually arises from within several hours to a few days after the procedure. Here we describe a putaminal hemorrhage with extravasation during angiography that developed immediately after carotid artery stenting. A search of the literature revealed only one other similar case report. The etiology of the intracerebral hemorrhage immediately after carotid stenting might be analogous to that of hypertensive hemorrhage.


Japanese Journal of Radiology | 2009

Carotid artery stenosis with intraluminal thrombus discovered during carotid artery stenting

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Toshiteru Miyasaka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Toshiaki Akashi; Kimihiko Kichikawa

A 77-year-old man presented with transient motor weakness of the left hand. Cerebral angiography showed 90% stenosis at the origin of the right internal carotid artery. Carotid artery stenting (CAS) was performed 3 weeks later, and a large intraluminal thrombus was found during the procedure. The blood around the thrombus was aspirated using an aspiration catheter under distal protection with a filter wire protection device, and CAS was successfully performed without complications. Although this patient was treated by CAS without complications, carotid stenosis associated with intraluminal thrombus—because it has a high risk of distal embolism—should be carefully diagnosed immediately before CAS.

Collaboration


Dive into the Kaoru Myouchin's collaboration.

Top Co-Authors

Avatar

Takeshi Wada

Nara Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge