Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Katsutoshi Takayama is active.

Publication


Featured researches published by Katsutoshi Takayama.


American Journal of Neuroradiology | 2008

Diffusion Tensor Tractography of the Meyer Loop in Cases of Temporal Lobe Resection for Temporal Lobe Epilepsy: Correlation between Postsurgical Visual Field Defect and Anterior Limit of Meyer Loop on Tractography

Toshiaki Taoka; Masahiko Sakamoto; Hiroyuki Nakagawa; Hiroyuki Nakase; Satoru Iwasaki; Katsutoshi Takayama; Keiko Taoka; Tohru Hoshida; Toshisuke Sakaki; Kimihiko Kichikawa

BACKGROUND AND PURPOSE: Visual field defects sometimes occur after temporal resection surgery. Our purpose was to evaluate the correlation between visual field defects caused by temporal lobe resection and the degree of resection of the Meyer loop, as assessed by diffusion tensor tractography. MATERIALS AND METHODS: We examined 14 patients who underwent temporal resection for temporal lobe epilepsy. We obtained presurgical tractographies and then measured the distance between the temporal tip and the anterior limit of the Meyer loop (T-M distance). The degree of resection of the Meyer loop was defined as the distance from the anterior limit of the Meyer loop to the posterior limit of the temporal lobe resection (M-R distance). This was calculated by subtracting the T-M distance from the measured distance between the temporal tip and the posterior limit of the resection (T-R distance). RESULTS: The mean T-M distance was 36.6 mm. The interindividual variation of the distance ranged from 30.0 to 43.2 mm. Although there was no statistically significant correlation between the extent of the visual field defect and the T-R distance, there was a statistically significant correlation between the degree of the visual field defect and the M-R distance. CONCLUSION: The range of interindividual variation for the position of the Meyer loop was rather large, indicating that this variation is the key factor in visual field defects after temporal lobectomy, and the visual field defect appears to be predicted by presurgical tractography. Evaluation of the Meyer loop through the use of tractography seems to be a feasible method, which can be used to predict the visual field defect after temporal lobe resection.


Journal of Computer Assisted Tomography | 1998

Age correlation of the time lag in signal change on EPI-fMRI

Toshiaki Taoka; Satoru Iwasaki; Hideo Uchida; Akio Fukusumi; Hiroyuki Nakagawa; Kimihiko Kichikawa; Katsutoshi Takayama; Tetsuya Yoshioka; Megumi Takewa; Hajime Ohishi

PURPOSE We measured the time lags between the start or end of tasks and signal changes in functional MRI (fMRI) for various age groups and evaluated the age correlation of the time lags. METHODS Forty subjects, 20-76 years old, were evaluated. fMRI was performed with and echo planar imaging sequence at 0.5 s intervals. We measured the time for the signal of the precentral gyrus to make a half-maximal increase after starting the task (T-inc) and the time to reach the initial level after ceasing the task (T-dec). RESULTS Average T-inc was 3.09 s and T-dec was 6.63 s. The values of T-inc could be correlated to age. T-dec had no age correlation. CONCLUSION The time lag in fMRI was revealed to be prolonged with increasing age. Our results suggest that the time lag in fMRI is influenced by some factors associated with aging.


NeuroImage | 2007

Diffusivity and diffusion anisotropy of cerebellar peduncles in cases of spinocerebellar degenerative disease

Toshiaki Taoka; Tesseki Kin; Hiroyuki Nakagawa; Makito Hirano; Masahiko Sakamoto; Takeshi Wada; Katsutoshi Takayama; Chatchada Wuttikul; Satoru Iwasaki; Satoshi Ueno; Kimihiko Kichikawa

PURPOSE This study accessed the feasibility of using tractography-based analysis to evaluate the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of three cerebellar peduncles in subtypes of spinocerebellar degenerative disease. MATERIALS AND METHODS We examined 7 cases of dentatorubro-pallidoluysian atrophy (DRPLA), 4 cases of multiple system atrophy, cerebellar type (MSA-C), 4 cases of late cerebellar cortical atrophy (LCCA) and 8 controls. Diffusion tensor images were obtained, and tractographies of cerebellar peduncles were generated. ADC and FA along the cerebellar peduncles and volume of cerebellar peduncle were measured, and analyses of variance were made among the control and each spinocerebellar degenerative disease groups. RESULTS There were statistically significant decrease in FA and volume and increase in ADC values between DRPLA cases and controls in all three cerebellar peduncles. On the other hand, MSA-C cases mainly showed statistically significant decreased FA and volume and increased ADC values in the middle cerebellar peduncle. LCCA cases did not show prominent difference in the three cerebellar peduncles. CONCLUSION The values of diffusivity and diffusion anisotropy of cerebellar peduncles evaluated by tractography based measurements seem to reflect characteristics of the different types of spinocerebellar degenerative diseases. Tractography-based measurements may be a feasible tool for differential diagnosis of spinocerebellar degenerative disease.


Journal of Computer Assisted Tomography | 2011

Usefulness of contrast-enhanced magnetic resonance angiography for follow-up of coil embolization with the enterprise stent for cerebral aneurysms.

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

Objective: The aim of this study was to determine the feasibility and usefulness of contrast-enhanced magnetic resonance angiography (CE-MRA) and 3-dimensional (3D) time-of-flight (TOF) MRA for follow-up of intracranial aneurysms treated using the Enterprise stent. Methods: Five aneurysm cases using the Enterprise stent were prospectively analyzed and were followed up with CE-MRA, 3D TOF MRA, and digital subtraction angiography (DSA). Depictions of parent artery lumen and the aneurysm neck with 3D TOF MRA and CE-MRA were compared with those of DSA. Results: In all cases, on 3D TOF MRA, it was difficult to evaluate the parent artery lumen and aneurysm neck owing to the significant artifacts from the stent. Contrast-enhanced MRA sufficiently demonstrated parent artery lumen and aneurysm neck distinctly and as clear as DSA did in all cases. Conclusions: For follow-up after coiling with an Enterprise stent, CE-MRA may be necessary to avoid susceptibility artifacts caused by the stent.


American Journal of Neuroradiology | 2012

Effect of Cilostazol in Preventing Restenosis after Carotid Artery Stenting Using the Carotid Wallstent: A Multicenter Retrospective Study

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Kinya Furuichi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

BACKGROUND AND PURPOSE: Restenosis after CAS is a postoperative problem, with a reported frequency of approximately 2%–8%. However differences in stent design, procedure, and the antiplatelet agent appear to affect the incidence of restenosis. We assessed the frequency of restenosis and the effect of the antiplatelet agent CLZ in preventing restenosis after CAS by the standard procedure using the CWS. MATERIALS AND METHODS: Between May 2010 and October 2011, 62 lesions in 60 consecutive patients underwent CAS using the CWS at 4 medical institutions, and all patients were followed clinically and assessed by sonography, 3D-CTA, or angiography at 3 and 6 months postoperatively. Restenosis was defined as ≥50% stenosis. The incidence of restenosis and the variation in the incidence of restenosis by the difference in type of antiplatelet agent between the CLZ group (n = 30; aspirin, 100 mg, and CLZ, 200 mg) and the non-CLZ group (n = 32; aspirin, 100 mg, and clopidogrel, 75 mg [n = 29]; or ticlopidine, 100 mg [n = 2] or 200 mg [n = 1]) were retrospectively investigated. Two antiplatelet agents were given starting 1 week preoperatively until at least 3 months postoperatively. RESULTS: Restenosis occurred in 5 patients (8.3%), but all were cases of asymptomatic lesions in the follow-up period. All 5 patients with restenosis were in the non-CLZ group, with no cases of restenosis in the CLZ group; the difference was significant (P = .0239). CONCLUSIONS: The restenosis rate after CAS by using the CWS was 8.3%. CLZ was associated with significant inhibition of restenosis.


Radiation Medicine | 2008

Initial experience of using the filter protection device during carotid artery stenting in Japan

Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Toshiteru Miyasaka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Ichiro Nakagawa; Shinichiro Kurokawa; Kimihiko Kichikawa

Purpose No filter protection devices for carotid artery stenting (CAS) have been formally approved for use in Japan; however, as of April 2008, the Angioguard XP (AGXP) was approved. This article describes our initial results using the AGXP during CAS for the treatment of carotid artery stenosis.


Radiation Medicine | 2007

Successful percutaneous transluminal angioplasty and stenting for symptomatic intracranial vertebral artery stenosis using intravascular ultrasound virtual histology

Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa

This is the first report of percutaneous transluminal angioplasty (PTA) of an intracranial artery applying intravascular ultrasound virtual histology (IVUS-VH), which has been recently developed for tissue characterization of coronary artery plaque. We report a case of successful PTA and stenting for symptomatic intracranial vertebral artery stenosis using IVUS-VH.


Journal of Stroke & Cerebrovascular Diseases | 2016

Influence of Diabetes Mellitus and Cigarette Smoking on Variability of the Clopidogrel-Induced Antiplatelet Effect and Efficacy of Active Management of the Target P2Y12 Reaction Unit Range in Patients Undergoing Neurointerventional Procedures

Ichiro Nakagawa; Hun Soo Park; Shohei Yokoyama; Takeshi Wada; Yasuo Hironaka; Yasushi Motoyama; Katsutoshi Takayama; Kimihiko Kichikawa; Hiroyuki Nakase

BACKGROUND Optimal antiplatelet inhibition is essential in patients undergoing neurointerventional procedures; however, variability in response to clopidogrel can contribute to thromboembolic and hemorrhagic complications. The present study evaluated the influence of diabetes mellitus and cigarette smoking on clopidogrel reactivity. METHODS Between 2011 and 2013, 71 consecutive patients underwent aneurysmal coil embolization (CE) or carotid artery stenting (CAS) and received clopidogrel (75 mg daily) and aspirin (100 mg daily) before the treatment. The patients were divided into 2 groups: CE (n = 31) and CAS (n = 40). The patients underwent prospective assessment of preoperative platelet function using VerifyNow assay and received adjunctive cilostazol (200 mg daily, triple antiplatelet therapy) in case of clopidogrel hyporesponse. Patients with clopidogrel hyper-response underwent clopidogrel dose reduction (clopidogrel, 12.5-50 mg daily). RESULTS Clopidogrel resistance was noted in 15 patients (37.5%) in the CAS group and in 4 patients (12.9%) in the CE group (P = .031). Clopidogrel hyper-response was noted in 2 patients (5%) in the CAS group and in 11 patients (54.8%) in the CE group (P < .001). There was a significant difference in the baseline clinical characteristics between the 2 groups. In the multivariate logistic regression analysis, diabetes and age were independent predictors of clopidogrel hyporesponse, whereas current smoker was an independent predictor of clopidogrel hyper-response. CONCLUSIONS Significant differences in baseline clinical characteristics were present when comparing patients undergoing endovascular treatment of unruptured cerebral aneurysms and carotid artery stenosis. Diabetes mellitus and current smoker status were independent factors related to reactivity to clopidogrel.


Neuroradiology | 2012

Application of susceptibility weighted imaging (SWI) for evaluation of draining veins of arteriovenous malformation: utility of magnitude images.

Toshiteru Miyasaka; Toshiaki Taoka; Hiroyuki Nakagawa; Takeshi Wada; Katsutoshi Takayama; Kaoru Myochin; Masahiko Sakamoto; Tomoko Ochi; Toshiaki Akashi; Kimihiko Kichikawa

IntroductionThe current study evaluated the signal characteristics of susceptibility weighted imaging (SWI) of arteriovenous malformation (AVM), especially for draining veins. For this purpose, we identified the draining veins of the AVM on angiography and evaluated the signal on magnitude image for SWI (SWI-mag) and minimum intensity projection image (SWI-minIP).MethodsSubjects were 14 cases with angiographically proven AVM. SWI-mag, SWI-minIP, and time-of-flight (TOF) magnetic resonance angiography were acquired. For the draining veins of the AVM identified on angiography, we analyzed signal intensity on the images listed above, and classified it into hyperintensity (hyper), mixed intensity (mixed), hypointensity (hypo), and no visualization.ResultsOn the analysis of 27 angiographically proven draining veins, 19 draining veins were classified as hyper, 3 as mixed, 0 as hypo, and 6 as no visualization on SWI-mag. On TOF images, 21 draining veins were classified as hyper, 2 as mixed, 0 as hypo, and 4 as no visualization, while 6 draining veins did not show hyperintensity on TOF, and SWI-mag visualized 3 of these 6 veins as hyper.ConclusionSWI-mag depicted most draining veins of AVM as hyperintensity. We speculate that this is mainly due to the higher concentration of oxygenated hemoglobin (oxy-Hb) and inflow effect of the draining vein. SWI-mag seems to be useful in the analysis and follow-up for AVM as the signal on the image may reflect physiological status.


Acta Radiologica | 2000

ENHANCEMENT PATTERN OF NORMAL EXTRAOCULAR MUSCLES IN DYNAMIC CONTRAST-ENHANCED MR IMAGING WITH FAT SUPPRESSION

Toshiaki Taoka; Satoru Iwasaki; Hideo Uchida; Akio Fukusumi; Kimihiko Kichikawa; Hiroyuki Nakagawa; Katsutoshi Takayama; Masahiko Sakamoto; Hajime Ohishi

PURPOSE To evaluate the internal structure of normal extraocular muscles on fat-suppressed dynamic contrast-enhanced MR imaging. MATERIAL AND METHODS Ten subjects were examined using fat-suppressed dynamic contrast-enhanced MR imaging. We evaluated the enhancement pattern (C-shaped or ring-like) of extraocular muscles and quantified the maximum ratios of enhancement (Rmax) and maximum ratios of signal increase (Vmax). We also quantified Rmax and Vmax in the central and peripheral portions of medial rectus muscles. RESULTS In the early phase of dynamic contrast-enhanced MR imaging, a C-shaped or ring-like pattern was observed in 100% of inferior rectus, 95% of medial rectus, 55% of superior rectus, 20% of lateral rectus, and 15% of superior oblique muscles. Overall mean Rmax and Vmax values showed statistically significant differences to the temporal muscles. For the peripheral portion of medial rectus muscles, mean Rmax and Vmax values were greater than for the central portion. CONCLUSION Using fat-suppressed dynamic contrast-enhanced MR imaging, the C-shape or ring-like internal structure of the extraocular muscles could be visualized, and were considered to reflect their structure of orbital and global layers. Potential usefulness of the fat-suppressed dynamic contrast-enhanced MR imaging for detecting pathological status is suggested.

Collaboration


Dive into the Katsutoshi Takayama's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Takeshi Wada

Nara Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge