Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Karen Venables is active.

Publication


Featured researches published by Karen Venables.


Lancet Oncology | 2008

The UK Standardisation of Breast Radiotherapy (START) Trial A of radiotherapy hypofractionation for treatment of early breast cancer: a randomised trial

Rajiv Agrawal; E. G. A. Aird; Jane Barrett; Peter Barrett-Lee; Søren M. Bentzen; Judith M. Bliss; Janet E. Brown; John Dewar; H. J. Dobbs; Joanne Haviland; P.J. Hoskin; Penelope Hopwood; Pat A Lawton; Brian J Magee; J. Mills; D. Morgan; Julie Owen; Sandra Simmons; Georges Sumo; Mark Sydenham; Karen Venables; John Yarnold

Summary Background The international standard radiotherapy schedule for breast cancer treatment delivers a high total dose in 25 small daily doses (fractions). However, a lower total dose delivered in fewer, larger fractions (hypofractionation) is hypothesised to be at least as safe and effective as the standard treatment. We tested two dose levels of a 13-fraction schedule against the standard regimen with the aim of measuring the sensitivity of normal and malignant tissues to fraction size. Methods Between 1998 and 2002, 2236 women with early breast cancer (pT1-3a pN0-1 M0) at 17 centres in the UK were randomly assigned after primary surgery to receive 50 Gy in 25 fractions of 2·0 Gy versus 41·6 Gy or 39 Gy in 13 fractions of 3·2 Gy or 3·0 Gy over 5 weeks. Women were eligible if they were aged over 18 years, did not have an immediate surgical reconstruction, and were available for follow-up. Randomisation method was computer generated and was not blinded. The protocol-specified principal endpoints were local-regional tumour relapse, defined as reappearance of cancer at irradiated sites, late normal tissue effects, and quality of life. Analysis was by intention to treat. This study is registered as an International Standard Randomised Controlled Trial, number ISRCTN59368779. Findings 749 women were assigned to the 50 Gy group, 750 to the 41·6 Gy group, and 737 to the 39 Gy group. After a median follow up of 5·1 years (IQR 4·4–6·0) the rate of local-regional tumour relapse at 5 years was 3·6% (95% CI 2·2–5·1) after 50 Gy, 3·5% (95% CI 2·1–4·3) after 41·6 Gy, and 5·2% (95% CI 3·5–6·9) after 39 Gy. The estimated absolute differences in 5-year local-regional relapse rates compared with 50 Gy were 0·2% (95% CI −1·3% to 2·6%) after 41·6 Gy and 0·9% (95% CI −0·8% to 3·7%) after 39 Gy. Photographic and patient self-assessments suggested lower rates of late adverse effects after 39 Gy than with 50 Gy, with an HR for late change in breast appearance (photographic) of 0·69 (95% CI 0·52–0·91, p=0·01). From a planned meta-analysis with the pilot trial, the adjusted estimates of α/β value for tumour control was 4·6 Gy (95% CI 1·1–8·1) and for late change in breast appearance (photographic) was 3·4 Gy (95% CI 2·3–4·5). Interpretation The data are consistent with the hypothesis that breast cancer and the dose-limiting normal tissues respond similarly to change in radiotherapy fraction size. 41·6 Gy in 13 fractions was similar to the control regimen of 50 Gy in 25 fractions in terms of local-regional tumour control and late normal tissue effects, a result consistent with the result of START Trial B. A lower total dose in a smaller number of fractions could offer similar rates of tumour control and normal tissue damage as the international standard fractionation schedule of 50 Gy in 25 fractions.


The Lancet | 2008

The UK Standardisation of Breast Radiotherapy (START) Trial B of radiotherapy hypofractionation for treatment of early breast cancer: a randomised trial.

Søren M. Bentzen; Rajiv Agrawal; E. G. A. Aird; Jane Barrett; Peter Barrett-Lee; Judith M. Bliss; Janet E. Brown; John Dewar; H. J. Dobbs; Joanne Haviland; P.J. Hoskin; Penelope Hopwood; Pat A Lawton; Brian J Magee; J. Mills; D. Morgan; Owen; Sandra Simmons; Georges Sumo; Mark Sydenham; Karen Venables; Yarnold

Summary Background The international standard radiotherapy schedule for early breast cancer delivers 50 Gy in 25 fractions of 2·0 Gy over 5 weeks, but there is a long history of non-standard regimens delivering a lower total dose using fewer, larger fractions (hypofractionation). We aimed to test the benefits of radiotherapy schedules using fraction sizes larger than 2·0 Gy in terms of local-regional tumour control, normal tissue responses, quality of life, and economic consequences in women prescribed post-operative radiotherapy. Methods Between 1999 and 2001, 2215 women with early breast cancer (pT1-3a pN0-1 M0) at 23 centres in the UK were randomly assigned after primary surgery to receive 50 Gy in 25 fractions of 2·0 Gy over 5 weeks or 40 Gy in 15 fractions of 2·67 Gy over 3 weeks. Women were eligible for the trial if they were aged over 18 years, did not have an immediate reconstruction, and were available for follow-up. Randomisation method was computer generated and was not blinded. The protocol-specified principal endpoints were local-regional tumour relapse, defined as reappearance of cancer at irradiated sites, late normal tissue effects, and quality of life. Analysis was by intention to treat. This study is registered as an International Standard Randomised Controlled Trial, number ISRCTN59368779. Findings 1105 women were assigned to the 50 Gy group and 1110 to the 40 Gy group. After a median follow up of 6·0 years (IQR 5·0–6·2) the rate of local-regional tumour relapse at 5 years was 2·2% (95% CI 1·3–3·1) in the 40 Gy group and 3·3% (95% CI 2·2 to 4·5) in the 50 Gy group, representing an absolute difference of −0·7% (95% CI −1·7% to 0·9%)—ie, the absolute difference in local-regional relapse could be up to 1·7% better and at most 1% worse after 40 Gy than after 50 Gy. Photographic and patient self-assessments indicated lower rates of late adverse effects after 40 Gy than after 50 Gy. Interpretation A radiation schedule delivering 40 Gy in 15 fractions seems to offer rates of local-regional tumour relapse and late adverse effects at least as favourable as the standard schedule of 50 Gy in 25 fractions.


Lancet Oncology | 2013

The UK Standardisation of Breast Radiotherapy (START) trials of radiotherapy hypofractionation for treatment of early breast cancer: 10-year follow-up results of two randomised controlled trials

Joanne Haviland; J Roger Owen; John Dewar; Rajiv Agrawal; Jane Barrett; Peter Barrett-Lee; H Jane Dobbs; Penelope Hopwood; Pat A Lawton; Brian J Magee; J. Mills; Sandra Simmons; Mark Sydenham; Karen Venables; Judith M. Bliss; John Yarnold

BACKGROUND 5-year results of the UK Standardisation of Breast Radiotherapy (START) trials suggested that lower total doses of radiotherapy delivered in fewer, larger doses (fractions) are at least as safe and effective as the historical standard regimen (50 Gy in 25 fractions) for women after primary surgery for early breast cancer. In this prespecified analysis, we report the 10-year follow-up of the START trials testing 13 fraction and 15 fraction regimens. METHODS From 1999 to 2002, women with completely excised invasive breast cancer (pT1-3a, pN0-1, M0) were enrolled from 35 UK radiotherapy centres. Patients were randomly assigned to a treatment regimen after primary surgery followed by chemotherapy and endocrine treatment (where prescribed). Randomisation was computer-generated and stratified by centre, type of primary surgery (breast-conservation surgery or mastectomy), and tumour bed boost radiotherapy. In START-A, a regimen of 50 Gy in 25 fractions over 5 weeks was compared with 41·6 Gy or 39 Gy in 13 fractions over 5 weeks. In START-B, a regimen of 50 Gy in 25 fractions over 5 weeks was compared with 40 Gy in 15 fractions over 3 weeks. Eligibility criteria included age older than 18 years and no immediate surgical reconstruction. Primary endpoints were local-regional tumour relapse and late normal tissue effects. Analysis was by intention to treat. Follow-up data are still being collected. This study is registered as an International Standard Randomised Controlled Trial, number ISRCTN59368779. FINDINGS START-A enrolled 2236 women. Median follow-up was 9·3 years (IQR 8·0-10·0), after which 139 local-regional relapses had occurred. 10-year rates of local-regional relapse did not differ significantly between the 41·6 Gy and 50 Gy regimen groups (6·3%, 95% CI 4·7-8·5 vs 7·4%, 5·5-10·0; hazard ratio [HR] 0·91, 95% CI 0·59-1·38; p=0·65) or the 39 Gy (8·8%, 95% CI 6·7-11·4) and 50 Gy regimen groups (HR 1·18, 95% CI 0·79-1·76; p=0·41). In START-A, moderate or marked breast induration, telangiectasia, and breast oedema were significantly less common normal tissue effects in the 39 Gy group than in the 50 Gy group. Normal tissue effects did not differ significantly between 41·6 Gy and 50 Gy groups. START-B enrolled 2215 women. Median follow-up was 9·9 years (IQR 7·5-10·1), after which 95 local-regional relapses had occurred. The proportion of patients with local-regional relapse at 10 years did not differ significantly between the 40 Gy group (4·3%, 95% CI 3·2-5·9) and the 50 Gy group (5·5%, 95% CI 4·2-7·2; HR 0·77, 95% CI 0·51-1·16; p=0·21). In START-B, breast shrinkage, telangiectasia, and breast oedema were significantly less common normal tissue effects in the 40 Gy group than in the 50 Gy group. INTERPRETATION Long-term follow-up confirms that appropriately dosed hypofractionated radiotherapy is safe and effective for patients with early breast cancer. The results support the continued use of 40 Gy in 15 fractions, which has already been adopted by most UK centres as the standard of care for women requiring adjuvant radiotherapy for invasive early breast cancer. FUNDING Cancer Research UK, UK Medical Research Council, UK Department of Health.


Radiotherapy and Oncology | 2011

First results of the randomised UK FAST Trial of radiotherapy hypofractionation for treatment of early breast cancer (CRUKE/04/015).

Rajiv Agrawal; Abdulla Alhasso; Peter Barrett-Lee; Judith M. Bliss; Peter Bliss; David Bloomfield; Joanna Bowen; A. Murray Brunt; E. Donovan; M. Emson; Andrew Goodman; Adrian Harnett; Joanne S. Havilan; Ronald Kaggwa; James Morden; Anne Robinson; Sandra Simmons; Alan Stewart; Mark Sydenham; Isabel Syndikus; Jean Tremlett; Y. Tsang; Duncan Wheatley; Karen Venables; John Yarnold

BACKGROUND AND PURPOSE Randomised trials testing 15- or 16-fraction regimens of adjuvant radiotherapy in women with early breast cancer have reported favourable outcomes compared with standard fractionation. To evaluate hypofractionation further, two 5-fraction schedules delivering 1 fraction per week have been tested against a 25-fraction regimen. MATERIALS AND METHODS Women aged ⩾50years with node negative early breast cancer were randomly assigned after microscopic complete tumour resection to 50Gy in 25 fractions versus 28.5 or 30Gy in 5 once-weekly fractions of 5.7 or 6.0Gy, respectively, to the whole breast. The primary endpoint was 2-year change in photographic breast appearance. RESULTS Nine hundred and fifteen women were recruited from 2004 to 2007. Seven hundred and twenty-nine patients had 2-year photographic assessments. Risk ratios for mild/marked change were 1.70 (95% CI 1.26-2.29, p<0.001) for 30Gy and 1.15 (0.82-1.60, p=0.489) for 28.5Gy versus 50Gy. Three-year rates of physician-assessed moderate/marked adverse effects in the breast were 17.3% (13.3-22.3%, p<0.001) for 30Gy and 11.1% (7.9-15.6%, p=0.18) for 28.5Gy compared with 9.5% (6.5-13.7%) after 50Gy. With a median follow-up in survivors of 37.3months, 2 local tumour relapses and 23 deaths have occurred. CONCLUSIONS At 3years median follow-up, 28.5Gy in 5 fractions is comparable to 50Gy in 25 fractions, and significantly milder than 30Gy in 5 fractions, in terms of adverse effects in the breast.


The Lancet | 2017

Partial-breast radiotherapy after breast conservation surgery for patients with early breast cancer (UK IMPORT LOW trial): 5-year results from a multicentre, randomised, controlled, phase 3, non-inferiority trial

Charlotte E. Coles; C. Griffin; Anna M. Kirby; Jenny Titley; Rajiv Agrawal; Abdulla Alhasso; I.S. Bhattacharya; A.M. Brunt; Laura Ciurlionis; Charlie Chan; E. Donovan; M. Emson; Adrian Harnett; Joanne Haviland; Penelope Hopwood; Monica L Jefford; Ronald Kaggwa; Elinor Sawyer; Isabel Syndikus; Y. Tsang; Duncan Wheatley; Maggie Wilcox; John Yarnold; Judith M. Bliss; Wail Al Sarakbi; Sarah Barber; Gillian C. Barnett; Peter Bliss; John Dewar; David Eaton

Summary Background Local cancer relapse risk after breast conservation surgery followed by radiotherapy has fallen sharply in many countries, and is influenced by patient age and clinicopathological factors. We hypothesise that partial-breast radiotherapy restricted to the vicinity of the original tumour in women at lower than average risk of local relapse will improve the balance of beneficial versus adverse effects compared with whole-breast radiotherapy. Methods IMPORT LOW is a multicentre, randomised, controlled, phase 3, non-inferiority trial done in 30 radiotherapy centres in the UK. Women aged 50 years or older who had undergone breast-conserving surgery for unifocal invasive ductal adenocarcinoma of grade 1–3, with a tumour size of 3 cm or less (pT1–2), none to three positive axillary nodes (pN0–1), and minimum microscopic margins of non-cancerous tissue of 2 mm or more, were recruited. Patients were randomly assigned (1:1:1) to receive 40 Gy whole-breast radiotherapy (control), 36 Gy whole-breast radiotherapy and 40 Gy to the partial breast (reduced-dose group), or 40 Gy to the partial breast only (partial-breast group) in 15 daily treatment fractions. Computer-generated random permuted blocks (mixed sizes of six and nine) were used to assign patients to groups, stratifying patients by radiotherapy treatment centre. Patients and clinicians were not masked to treatment allocation. Field-in-field intensity-modulated radiotherapy was delivered using standard tangential beams that were simply reduced in length for the partial-breast group. The primary endpoint was ipsilateral local relapse (80% power to exclude a 2·5% increase [non-inferiority margin] at 5 years for each experimental group; non-inferiority was shown if the upper limit of the two-sided 95% CI for the local relapse hazard ratio [HR] was less than 2·03), analysed by intention to treat. Safety analyses were done in all patients for whom data was available (ie, a modified intention-to-treat population). This study is registered in the ISRCTN registry, number ISRCTN12852634. Findings Between May 3, 2007, and Oct 5, 2010, 2018 women were recruited. Two women withdrew consent for use of their data in the analysis. 674 patients were analysed in the whole-breast radiotherapy (control) group, 673 in the reduced-dose group, and 669 in the partial-breast group. Median follow-up was 72·2 months (IQR 61·7–83·2), and 5-year estimates of local relapse cumulative incidence were 1·1% (95% CI 0·5–2·3) of patients in the control group, 0·2% (0·02–1·2) in the reduced-dose group, and 0·5% (0·2–1·4) in the partial-breast group. Estimated 5-year absolute differences in local relapse compared with the control group were −0·73% (−0·99 to 0·22) for the reduced-dose and −0·38% (−0·84 to 0·90) for the partial-breast groups. Non-inferiority can be claimed for both reduced-dose and partial-breast radiotherapy, and was confirmed by the test against the critical HR being more than 2·03 (p=0·003 for the reduced-dose group and p=0·016 for the partial-breast group, compared with the whole-breast radiotherapy group). Photographic, patient, and clinical assessments recorded similar adverse effects after reduced-dose or partial-breast radiotherapy, including two patient domains achieving statistically significantly lower adverse effects (change in breast appearance [p=0·007 for partial-breast] and breast harder or firmer [p=0·002 for reduced-dose and p<0·0001 for partial-breast]) compared with whole-breast radiotherapy. Interpretation We showed non-inferiority of partial-breast and reduced-dose radiotherapy compared with the standard whole-breast radiotherapy in terms of local relapse in a cohort of patients with early breast cancer, and equivalent or fewer late normal-tissue adverse effects were seen. This simple radiotherapy technique is implementable in radiotherapy centres worldwide. Funding Cancer Research UK.


Radiotherapy and Oncology | 2014

A multi-institutional dosimetry audit of rotational intensity-modulated radiotherapy

Catharine H. Clark; M. Hussein; Yatman Tsang; R. Thomas; Dean Wilkinson; Graham Bass; J.A.D. Snaith; C. Gouldstone; Steve Bolton; Rebecca Nutbrown; Karen Venables; A. Nisbet

BACKGROUND Rotational IMRT (VMAT and Tomotherapy) has now been implemented in many radiotherapy centres. An audit to verify treatment planning system modelling and treatment delivery has been undertaken to ensure accurate clinical implementation. MATERIAL AND METHODS 34 institutions with 43 treatment delivery systems took part in the audit. A virtual phantom planning exercise (3DTPS test) and a clinical trial planning exercise were planned and independently measured in each institution using a phantom and array combination. Point dose differences and global gamma index (γ) were calculated in regions corresponding to PTVs and OARs. RESULTS Point dose differences gave a mean (±sd) of 0.1±2.6% and 0.2±2.0% for the 3DTPS test and clinical trial plans, respectively. 34/43 planning and delivery combinations achieved all measured planes with >95% pixels passing γ<1 at 3%/3mm and rose to 42/43 for clinical trial plans. A statistically significant difference in γ pass rates (p<0.01) was seen between planning systems where rotational IMRT modelling had been designed for the manufacturers own treatment delivery system and those designed independently of rotational IMRT delivery. CONCLUSIONS A dosimetry audit of rotational radiotherapy has shown that TPS modelling and delivery for rotational IMRT can achieve high accuracy of plan delivery.


International Journal of Radiation Oncology Biology Physics | 2003

Three-dimensional distribution of radiation within the breast: an intercomparison of departments participating in the START trial of breast radiotherapy fractionation

Karen Venables; Elizabeth Winfield; Edwin Aird; Peter Hoskin

PURPOSE To examine the ability of computer planning systems to calculate the dose to the breast correctly in three dimensions. Both the absolute dose at the center of the breast and the accuracy of the isodose distributions were investigated. METHODS AND MATERIALS Measurements were performed in a water-filled breast phantom using an ionization chamber. Thirty-six sets of data obtained during the Standardization of Breast Radiotherapy breast fractionation trial quality assurance program were included in the analysis. The planning systems were grouped according to the algorithms used on the basis of the definitions given in International Commission on Radiation Units and Measurements Report No. 24. RESULTS Thirty-two of the 36 planning systems overestimated the dose to the center of the breast, with a mean measured/calculated dose ratio of 0.979 (SD 0.013). The relative dose within 2 cm of the lung was also overestimated. CONCLUSION Only one algorithm (collapsed cone) investigated in this study was able to calculate the dose at the center of the breast correctly in tangential breast radiotherapy. With modern algorithms, it is important to include a correction for the lower density of the lung, because the dose close to the interface between breast and lung tissue will also be lower than anticipated.


British Journal of Radiology | 2015

Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials

Catharine H. Clark; Edwin G.A. Aird; Steve Bolton; E. Miles; A. Nisbet; J.A.D. Snaith; R. Thomas; Karen Venables; D.I. Thwaites

Dosimetry audit plays an important role in the development and safety of radiotherapy. National and large scale audits are able to set, maintain and improve standards, as well as having the potential to identify issues which may cause harm to patients. They can support implementation of complex techniques and can facilitate awareness and understanding of any issues which may exist by benchmarking centres with similar equipment. This review examines the development of dosimetry audit in the UK over the past 30 years, including the involvement of the UK in international audits. A summary of audit results is given, with an overview of methodologies employed and lessons learnt. Recent and forthcoming more complex audits are considered, with a focus on future needs including the arrival of proton therapy in the UK and other advanced techniques such as four-dimensional radiotherapy delivery and verification, stereotactic radiotherapy and MR linear accelerators. The work of the main quality assurance and auditing bodies is discussed, including how they are working together to streamline audit and to ensure that all radiotherapy centres are involved. Undertaking regular external audit motivates centres to modernize and develop techniques and provides assurance, not only that radiotherapy is planned and delivered accurately but also that the patient dose delivered is as prescribed.


Physics in Medicine and Biology | 2001

The START Trial - measurements in semi-anatomical breast and chest wall phantoms

Karen Venables; Elizabeth Winfield; A Deighton; Edwin Aird; Peter Hoskin

This paper describes dosimetry measurements performed prior to departments entering patients into the START Trial, a breast fractionation trial. Absolute and relative doses were measured in semi-anatomical breast and chest wall phantoms, as part of a quality assurance programme visit. Doses were measured using an ionization chamber and the resulting distributions were compared with those calculated by the department. The mean ratio of measured to calculated dose at the START reference point was found to be 0.981 for the breast phantom and 0.978 for the chest wall phantom. This average measured dose was significantly less than the prescribed dose (p < 0.001). Differences were found between 2D and 3D planning systems and for departments using cobalt 60 beams. A number of departments had deviations of greater than 4%, which was the tolerance applied for this trial. It is essential for dose measurements of this type to be performed for randomized clinical trials involving radiotherapy, particularly where dose fractionation regimes are being compared.


Radiotherapy and Oncology | 2009

Dosimetry and field matching for radiotherapy to the breast and supraclavicular fossa

Elizabeth A. Miles; Karen Venables; Peter Hoskin; Edwin Aird

PURPOSE Early breast cancer radiotherapy aims for local disease control and reduced recurrence. Treatment is directed to breast or chest wall alone using tangential fields, or includes regional lymph nodes with a separate anterior field. The complex geometry of this region necessitates matching adjacent radiation fields in three-dimensions. Potential exists for overdosage or underdosage and cosmetic results may be compromised if fields are not accurately aligned. METHODS AND MATERIALS A study of dosimetry across the match line region using different techniques, as reported in the multicentre START Trial Quality Assurance programme, was undertaken. A custom-made anthropomorphic phantom assessed dose distribution in three-dimensions using film dosimetry. RESULTS Methods with varying degrees of complexity were employed for field matching. Techniques combined half beam blocking and machine rotations to achieve geometric alignment. Asymmetric beam matching allowed use of a single isocentre technique. Where field matching was not undertaken a gap between tangential and nodal fields was employed. Results demonstrated differences between techniques and variations for similar techniques in different centres. Geometric alignment techniques produced more homogenous dose distributions in the match region than gap techniques or those techniques not correcting for field divergence. CONCLUSIONS Field matching techniques during the START trial varied between centres. Film dosimetry used in conjunction with a breast-shaped phantom provided relative dose information. The study highlighted difficulties in matching treatment fields to achieve homogenous dose distribution through the region of the match plane and the degree of inhomogeneity as a consequence of a gap between treatment fields.

Collaboration


Dive into the Karen Venables's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

John Yarnold

Institute of Cancer Research

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

E. Miles

Mount Vernon Hospital

View shared research outputs
Top Co-Authors

Avatar

Joanne Haviland

Institute of Cancer Research

View shared research outputs
Top Co-Authors

Avatar

Judith M. Bliss

Institute of Cancer Research

View shared research outputs
Top Co-Authors

Avatar

Mark Sydenham

Institute of Cancer Research

View shared research outputs
Top Co-Authors

Avatar

Sandra Simmons

Institute of Cancer Research

View shared research outputs
Top Co-Authors

Avatar

Catharine H. Clark

Royal Surrey County Hospital

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge