Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Karina Klein is active.

Publication


Featured researches published by Karina Klein.


European Heart Journal | 2010

Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy

Christian Templin; Martin Meyer; Maja Müller; Valentin Djonov; Ruslan Hlushchuk; Ivanka Dimova; Stefanie Flueckiger; Peter W. Kronen; Michèle Sidler; Karina Klein; Flora Nicholls; Jelena-Rima Ghadri; Klaus Weber; Dragica Paunovic; Roberto Corti; Simon P. Hoerstrup; Thomas F. Lüscher; Ulf Landmesser

Aims Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial ∼10–20 µm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model. Methods and results Twenty stents were implanted into 10 pigs and coronary OFDI was performed after 1, 3, 10, 14, and 28 days. Neointimal thickness as detected by OFDI correlated closely with neointimal thickness as measured by LM (r = 0.90, P < 0.01). The comparison of stent strut coverage as detected by OFDI and SEM analysis revealed an excellent agreement (r = 0.96, P < 0.01). In particular, stents completely covered by OFDI analysis were also completely covered by SEM analysis. All incompletely covered stents by OFDI were also incompletely covered by SEM. Analyses of fibrin-covered stent struts suggested that these may rarely be detected as uncovered stent struts by OFDI. Importantly, optical density measurements revealed a significant difference between fibrin- and neointima-covered coronary stent struts [0.395 (0.35–0.43) vs. 0.53 (0.47–0.57); P < 0.001], suggesting that differences in optical density provide information on the type of stent strut coverage. The sensitivity and specificity for detection of fibrin vs. neointimal coverage was evaluated using receiver-operating characteristic analysis. Conclusion The present study demonstrates that OFDI is a highly promising tool for accurate evaluation of coronary stent strut coverage, as supported by a high agreement between OFDI and light and electron microscopic analysis. Furthermore, our data indicate that optical density measurements can provide additional information with respect to the type of stent strut coverage, i.e. fibrin vs. neointimal coverage. Therefore, coronary OFDI analysis will provide important information on the biocompatibility of coronary stents.


BMC Musculoskeletal Disorders | 2012

Osseointegration and biocompatibility of different metal implants - a comparative experimental investigation in sheep

Michael Plecko; Christine Sievert; Daniel Andermatt; Robert Frigg; Peter W. Kronen; Karina Klein; Stefan Stübinger; Katja Nuss; Alexander Bürki; Stephen J. Ferguson; Ulrich Stoeckle; Brigitte von Rechenberg

BackgroundIn the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.MethodsMaterials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.ResultsCobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.ConclusionThis study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.


The Open Orthopaedics Journal | 2011

Biocompatibility and Bone Formation of Flexible, Cotton Wool-like PLGA/Calcium Phosphate Nanocomposites in Sheep

Oliver Schneider; Dirk Mohn; Roland Fuhrer; Karina Klein; Käthi Kämpf; Katja Nuss; Michèle Sidler; Katalin Zlinszky; Brigitte von Rechenberg; Wendelin J. Stark

Background: The purpose of this preliminary study was to assess the in vivo performance of synthetic, cotton wool-like nanocomposites consisting of a biodegradable poly(lactide-co-glycolide) fibrous matrix and containing either calcium phosphate nanoparticles (PLGA/CaP 60:40) or silver doped CaP nanoparticles (PLGA/Ag-CaP 60:40). Besides its extraordinary in vitro bioactivity the latter biomaterial (0.4 wt% total silver concentration) provides additional antimicrobial properties for treating bone defects exposed to microorganisms. Materials and Methods: Both flexible artificial bone substitutes were implanted into totally 16 epiphyseal and metaphyseal drill hole defects of long bone in sheep and followed for 8 weeks. Histological and histomorphological analyses were conducted to evaluate the biocompatibility and bone formation applying a score system. The influence of silver on the in vivo performance was further investigated. Results: Semi-quantitative evaluation of histology sections showed for both implant materials an excellent biocompatibility and bone healing with no resorption in the adjacent bone. No signs of inflammation were detectable, either macroscopically or microscopically, as was evident in 5 µm plastic sections by the minimal amount of inflammatory cells. The fibrous biomaterials enabled bone formation directly in the centre of the former defect. The area fraction of new bone formation as determined histomorphometrically after 8 weeks implantation was very similar with 20.5 ± 11.2 % and 22.5 ± 9.2 % for PLGA/CaP and PLGA/Ag-CaP, respectively. Conclusions: The cotton wool-like bone substitute material is easily applicable, biocompatible and might be beneficial in minimal invasive surgery for treating bone defects.


Journal of Biomedical Materials Research Part B | 2013

Histological and biomechanical analysis of porous additive manufactured implants made by direct metal laser sintering: a pilot study in sheep.

Stefan Stübinger; Isabel Mosch; Pierfrancesco Robotti; Michèle Sidler; Karina Klein; Stephen J. Ferguson; Brigitte von Rechenberg

OBJECTIVES It was the aim of this study to analyze osseointegrative properties of porous additive manufactured titanium implants made by direct metal laser sintering in a sheep model after an implantation period of 2 and 8 weeks. MATERIAL AND METHODS Three different types of implants were placed in the pelvis of six sheep. In each sheep were placed three standard machined (M), three sandblasted and etched (SE), and three porous additive manufactured (AM) implants. Of these three implants (one per type) were examined histologically and six implants were tested biomechanically. Additionally a semiquantitative histomorphometrical and qualitative fluorescent microscopic analysis were performed. RESULTS After 2 and 8 weeks bone-to-implant-contact (BIC) values of the AM surface (2w: 20.49% ± 5.18%; 8w: 43.91% ± 9.69%) revealed no statistical significant differences in comparison to the M (2w: 20.33% ± 11.50%; 8w: 25.33% ± 4.61%) and SE (2w: 43.67 ± 12.22%; 8w: 53.33 ± 8.96%) surfaces. AM surface showed the highest increase of the BIC between the two observation time points. Considering the same implantation period histomorphometry and fluorescent labelling disclosed no significant differences in the bone surrounding the three implants groups. In contrast Removal-torque-test showed a significant improve in fixation strength (P ≤ 0.001) for the AM (1891.82 ± 308, 44 Nmm) surface after eight weeks in comparison to the M (198.93±88,04 Nmm) and SE (730.08 ± 151,89 Nmm) surfaces. CONCLUSION All three surfaces (M, SE, and AM) showed sound osseointegration. AM implants may offer a possible treatment option in clinics for patients with compromised bone situations.


Injury-international Journal of The Care of The Injured | 2013

The dynamisation of locking plate osteosynthesis by means of dynamic locking screws (DLS)—An experimental study in sheep

Michael Plecko; Nico Lagerpusch; Daniel Andermatt; Robert Frigg; Rudolf Koch; Michèle Sidler; Peter W. Kronen; Karina Klein; Katja Nuss; Alexander Bürki; Stephen J. Ferguson; Ulrich Stoeckle; Jörg A Auer; Brigitte von Rechenberg

In this in vivo study a new generation of locking screws was tested. The design of the dynamic locking screw (DLS) enables the dynamisation of the cortex underneath the plate (cis-cortex) and, therefore, allows almost parallel interfragmentary closure of the fracture gap. A 45° angle osteotomy was performed unilaterally on the tibia of 37 sheep. Groups of 12 sheep were formed and in each group a different osteotomy gap (0, 1 and 3mm) was fixed using a locking compression plate (LCP) in combination with the DLS. The healing process was monitored radiographically every 3 weeks for 6, respectively 12 weeks. After this time the sheep were sacrificed, the bones harvested and the implants removed. The isolated bones were evaluated in the micro-computed tomography unit, tested biomechanically and evaluated histologically. The best results of interfragmentary movement (IFM) were shown in the 0mm configuration. The bones of this group demonstrated histomorphometrically the most distinct callus formation on the cis-cortex and the highest torsional stiffness relative to the untreated limb at 12 weeks after surgery. This animal study showed that IFM stimulated the synthesis of new bone matrix, especially underneath the plate and thus, could solve a current limitation in normal human bone healing. The DLS will be a valuable addition to the locking screw technology and improve fracture healing.


Injury-international Journal of The Care of The Injured | 2012

The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy

Michael Plecko; Nico Lagerpusch; Birthe Pegel; Daniel Andermatt; Robert Frigg; Rudolf Koch; Michèle Sidler; Peter W. Kronen; Karina Klein; Katja Nuss; Philippe Gédet; Alexander Bürki; Stephen J. Ferguson; Ulrich Stoeckle; Jörg A Auer; Brigitte von Rechenberg

BACKGROUND Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing. STUDY DESIGN In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6 weeks, and the other half (6 sheep) where followed for 12 weeks. METHODS X-rays at 3, 6, 9 and 12 weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy. RESULTS In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6 weeks, but after 12 weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12 weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6 weeks. DISCUSSION AND CONCLUSION All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.


Journal of Bone and Joint Surgery, American Volume | 2016

Dynamic Stabilization with Active Locking Plates Delivers Faster, Stronger, and More Symmetric Fracture-Healing

Michael Bottlang; Stanley Tsai; Emily K. Bliven; Brigitte von Rechenberg; Karina Klein; Peter Augat; Julia Henschel; Daniel C. Fitzpatrick; Steven M. Madey

BACKGROUND Axial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates. METHODS Twelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure. RESULTS At each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap. CONCLUSIONS Symmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. CLINICAL RELEVANCE The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.


Veterinary Surgery | 2012

Biodegradable Sleeves for Metal Implants to Prevent Implant-Associated Infection: An Experimental In Vivo Study in Sheep

Stephanie C. von Plocki; David Armbruster; Karina Klein; Käthi Kämpf; Katalin Zlinszky; Monika Hilbe; Peter W. Kronen; Elliott Gruskin; Brigitte von Rechenberg

OBJECTIVE To evaluate biocompatibility of biodegradable sleeves containing antimicrobial agents, designed for local drug delivery to prevent implant-related infection. STUDY DESIGN Synthetic polyester sleeves (a copolymer of glycolide, caprolactone, trimethylene carbonate, lactide) were cast as thin films. The antimicrobial agents incorporated in the sleeves included gentamicin sulfate, triclosan, or a combination of these drugs. ANIMALS Adult sheep (n = 15). METHODS Two limited contact dynamic compression plates (LC-DCP) with or without sleeves were implanted on tibiae (bilateral) of 15 sheep. Sleeves were placed over the plates before implantation. Beneath half of the plates, 5-mm drill hole defects were made in the near cortex. Samples were harvested 4 weeks later for histology and microradiography. RESULTS Macroscopically, no irritation of bone or adjacent tissue was seen. Small remnants of sleeves were visible on histology, and positively correlated with the presence of macrophages and foreign body cells. Thick sections showed no difference between the test samples and controls in terms of fibrous capsule formation, periosteal remodeling, and defect remodeling. Inflammatory cells, macrophages, and foreign body cells were more prominent in sections with sleeves, but were not statistically significantly different from controls. Cell numbers were within normal physiologic limits normally seen as cellular response to foreign bodies consisting of polymers. CONCLUSION The normal healing response indicated that the biodegradable sleeves demonstrate tissue biocompatibility.


BMC Musculoskeletal Disorders | 2013

Bone augmentation for cancellous bone- development of a new animal model

Karina Klein; Enrico Zamparo; Peter W. Kronen; Katharina Kämpf; Mariano Makara; Thomas Steffen; Brigitte von Rechenberg

BackgroundReproducible and suitable animal models are required for in vivo experiments to investigate new biodegradable and osteoinductive biomaterials for augmentation of bones at risk for osteoporotic fractures. Sheep have especially been used as a model for the human spine due to their size and similar bone metabolism. However, although sheep and human vertebral bodies have similar biomechanical characteristics, the shape of the vertebral bodies, the size of the transverse processes, and the different orientation of the facet joints of sheep are quite different from those of humans making the surgical approach complicated and unpredictable. Therefore, an adequate and safe animal model for bone augmentation was developed using a standardized femoral and tibia augmentation site in sheep.MethodsThe cancellous bone of the distal femur and proximal tibia were chosen as injection sites with the surgical approach via the medial aspects of the femoral condyle and proximal tibia metaphysis (n = 4 injection sites). For reproducible drilling and injection in a given direction and length, a custom-made c-shaped aiming device was designed. Exact positioning of the aiming device and needle positioning within the intertrabecular space of the intact bone could be validated in a predictable and standardized fashion using fluoroscopy. After sacrifice, bone cylinders (∅ 32 mm) were harvested throughout the tibia and femur by means of a diamond-coated core drill, which was especially developed to harvest the injected bone area exactly. Thereafter, the extracted bone cylinders were processed as non-decalcified specimens for μCT analysis, histomorphometry, histology, and fluorescence evaluation.ResultsThe aiming device could be easily placed in 63 sheep and assured a reproducible, standardized injection area. In four sheep, cardiovascular complications occurred during surgery and pulmonary embolism was detected by computed tomography post surgery in all of these animals. The harvesting and evaluative methods assured a standardized analysis of all samples.ConclusionsThis experimental animal model provides an excellent basis for testing new biomaterials for their suitability as bone augmentation materials. Concomitantly, similar cardiovascular changes occur during vertebroplasties as in humans, thus making it a suitable animal model for studies related to vertebroplasty.


Journal of Bone and Joint Surgery, American Volume | 2015

Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.

Henning Richter; Michael Plecko; Daniel Andermatt; Robert Frigg; Peter W. Kronen; Karina Klein; Katja Nuss; Stephen J. Ferguson; Ulrich Stöckle; Brigitte von Rechenberg

BACKGROUND Locking plates are widely used in fracture fixation, mainly for meta-diaphyseal fractures, comminuted fractures, fractures with a critical-size bone defect, periprosthetic fractures, osteotomies, and fractures in osteoporotic bone. The aim of this animal study was to evaluate the effect on bone-healing of dynamization of locking plate constructs by means of new 5.0-mm dynamic locking screws (in the DLS group), which allow near-cortex micromotion, compared with a more rigid construct utilizing standard bicortical locking-head screws (in the LS group). Use of dynamic locking screws allows modulation of the stiffness of existing locking compression plate systems via parallel interfragmentary micromotion. METHODS A standardized diaphyseal tibial osteotomy (90°, 3-mm fracture gap) was performed and stabilized with a six-hole large-fragment locking compression plate in twelve female sheep (six in each group). Radiographs were made postoperatively and then weekly from week three until sacrifice at nine weeks. Macroscopic, biomechanical, histologic, and radiographic assessments and microcomputed tomography were performed. RESULTS The callus in the tested specimens in the DLS group had better biomechanical stability, with a significantly greater maximum failure moment (mean and standard deviation [SD] as a percentage of intact, 55.15 ± 20.65 compared with 26.80 ± 14.96 in the LS group; p = 0.021). The DLS group also had greater periosteal callus volume at the near cortex (mean volume and SD as a percentage of the tibial shaft volume, 36.21% ± 10.08% compared with 18.98% ± 8.61% in the LS group; p = 0.026) and in the intercortical region (mean volume and SD as a percentage of the bone volume of the tibial shaft, 3.56% ± 0.52% compared with 2.64% ± 0.98% in the LS group; p = 0.045), as shown by microcomputed tomography. The DLS group also had significantly greater torsional stiffness (mean and SD as a percentage of intact, 84.88 ± 13.51 compared with 58.89 ± 20.61 in the LS group; p = 0.027). CONCLUSIONS Controlled micromotion and nearly homogeneous interfragmentary strain at the fracture site, together with the stable bicortical fixation achieved by the new dynamic locking screw, led to more uniform callus formation, significantly more callus formation at the near cortex, and biomechanically more competent bone-healing compared with use of rigid locking plate constructs with locking-head screws.

Collaboration


Dive into the Karina Klein's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge