Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Karun Sharma is active.

Publication


Featured researches published by Karun Sharma.


Journal of Controlled Release | 2012

Image-guided drug delivery with magnetic resonance guided high intensity focused ultrasound and temperature sensitive liposomes in a rabbit Vx2 tumor model.

Ashish Ranjan; Genevieve Jacobs; David L. Woods; Ayele H. Negussie; Ari Partanen; Pavel S. Yarmolenko; C. Gacchina; Karun Sharma; Victor Frenkel; Bradford J. Wood; Matthew R. Dreher

Clinical-grade doxorubicin encapsulated low temperature sensitive liposomes (LTSLs) were combined with a clinical magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) platform to investigate in vivo image-guided drug delivery. Plasma pharmacokinetics were determined in 3 rabbits. Fifteen rabbits with Vx2 tumors within superficial thigh muscle were randomly assigned into three treatment groups: 1) free doxorubicin, 2) LTSL and 3) LTSL + MR-HIFU. For the LTSL + MR-HIFU group, mild hyperthermia (40-41 °C) was applied to the tumors using an MR-HIFU system. Image-guided non-invasive hyperthermia was applied for a total of 30 min, completed within 1h after LTSL infusion. High-pressure liquid chromatography (HPLC) analysis of the harvested tumor and organ/tissue homogenates was performed to determine doxorubicin concentration. Fluorescence microscopy was performed to determine doxorubicin spatial distribution in the tumors. Sonication of Vx2 tumors resulted in accurate (mean = 40.5 ± 0.1 °C) and spatially homogenous (SD = 1.0 °C) temperature control in the target region. LTSL + MR-HIFU resulted in significantly higher tumor doxorubicin concentrations (7.6- and 3.4-fold greater compared to free doxorubicin and LTSL respectively, p<0.05, Newman-Keuls). This improved tumor concentration was achieved despite heating <25% of the tumor volume. Free doxorubicin and LTSL treatments appeared to deliver more drug in the tumor periphery as compared to the tumor core. In contrast, LTSL + MR-HIFU treatment suggested an improved distribution with doxorubicin found in both the tumor periphery and core. Doxorubicin bio-distribution in non-tumor organs/tissues was fairly similar between treatment groups. This technique has potential for clinical translation as an image-guided method to deliver drug to a solid tumor.


Theranostics | 2016

A Novel Inherently Radiopaque Bead for Transarterial Embolization to Treat Liver Cancer - A Pre-clinical Study

Rafael Duran; Karun Sharma; Matthew R. Dreher; Koorosh Ashrafi; Sahar Mirpour; Ming De Lin; Ruediger E. Schernthaner; Todd Schlachter; Vania Tacher; Andrew L. Lewis; Sean Willis; Mark den Hartog; Alessandro Radaelli; Ayele H. Negussie; Bradford J. Wood; Jean Francois H Geschwind

Purpose: Embolotherapy using microshperes is currently performed with soluble contrast to aid in visualization. However, administered payload visibility dimishes soon after delivery due to soluble contrast washout, leaving the radiolucent beads location unknown. The objective of our study was to characterize inherently radiopaque beads (RO Beads) in terms of physicomechanical properties, deliverability and imaging visibility in a rabbit VX2 liver tumor model. Materials and Methods: RO Beads, which are based on LC Bead® platform, were compared to LC Bead. Bead size (light microscopy), equilibrium water content (EWC), density, X-ray attenuation and iodine distribution (micro-CT), suspension (settling times), deliverability and in vitro penetration were investigated. Fifteen rabbits were embolized with either LC Bead or RO Beads + soluble contrast (iodixanol-320), or RO Beads+dextrose. Appearance was evaluated with fluoroscopy, X-ray single shot, cone-beam CT (CBCT). Results: Both bead types had a similar size distribution. RO Beads had lower EWC (60-72%) and higher density (1.21-1.36 g/cc) with a homogeneous iodine distribution within the beads interior. RO Beads suspension time was shorter than LC Bead, with durable suspension (>5 min) in 100% iodixanol. RO Beads ≤300 µm were deliverable through a 2.3-Fr microcatheter. Both bead types showed similar penetration. Soluble contrast could identify target and non-target embolization on fluoroscopy during administration. However, the imaging appearance vanished quickly for LC Bead as contrast washed-out. RO Beads+contrast significantly increased visibility on X-ray single shot compared to LC Bead+contrast in target and non-target arteries (P=0.0043). Similarly, RO beads demonstrated better visibility on CBCT in target arteries (P=0.0238) with a trend in non-target arteries (P=0.0519). RO Beads+dextrose were not sufficiently visible to monitor embolization using fluoroscopy. Conclusion: RO Beads provide better conspicuity to determine target and non-target embolization compared to LC Bead which may improve intra-procedural monitoring and post-procedural evaluation of transarterial embolization.


International Journal of Hyperthermia | 2015

Temperature-sensitive liposome-mediated delivery of thrombolytic agents

Vishal Saxena; Carmen Gacchina Johnson; Ayele H. Negussie; Karun Sharma; Matthew R. Dreher; Bradford J. Wood

Abstract Background: Clinical efficacy of thrombolytic drugs is limited by lack of specific delivery and requires large therapeutic doses which increase toxicity. Encapsulating these drugs in temperature-sensitive liposomes and applying hyperthermia to deliver thrombolytic agents locally to thrombus might theoretically favourably alter the therapeutic window. The objectives of this study were to formulate liposomes encapsulating thrombolytics and assess thrombolytic activity following hyperthermia. Methods: Three liposome formulations were investigated: temperature-sensitive liposome (TSL, DPPC:DSPE-PEG2000 (mol% 95:5)), low temperature-sensitive liposome (LTSL, DPPC:MSPC:DSPE-PEG2000 (mol% 85.3:9.7:5)), and traditional temperature-sensitive liposome (TTSL, DPPC:HSPC:Chol:DSPE-PEG2000 (mol% 55:25:15:5)). To characterise temperature-dependent release of high molecular weight cargo from each formulation, fluorescein-conjugated dextrans (70 kDa) were loaded and release was quantified via spectrophotometry. Staphylokinase (SAK), urokinase, and tissue-type plasminogen activator were also loaded individually into each liposome formulation. Leakage at 37 °C and release at 38–44 °C were quantified via chromogenic enzymatic activity assay. Clot lysis was evaluated by measuring mass of blood clots before and after thrombolytic liposome treatment. Results: The LTSL formulation had optimal release characteristics with maximum release at 41.3 °C. Release of dextrans from LTSLs was observed to be 11.5 ± 1.5%, 79.7 ± 1.6%, and 93.6 ± 3.7% after 15 min in plasma at 37°, 39°, and 41.3 °C, respectively. The SAK LTSL had the highest release/leakage ratio and demonstrated greater clot lysis. Conclusions: The SAK LTSL achieves significant clot lysis in vitro. When combined with local hyperthermia, the SAK LTSL potentially produces sufficient thrombolysis while minimising systemic side effects.


Radiology | 2016

Multimodality Imaging of Ethiodized Oil–loaded Radiopaque Microspheres during Transarterial Embolization of Rabbits with VX2 Liver Tumors

Vania Tacher; Rafael Duran; M. Lin; Jae Ho Sohn; Karun Sharma; Zhijun Wang; Julius Chapiro; Carmen Gacchina Johnson; Nikhil Bhagat; Matthew R. Dreher; Dirk Schäfer; David L. Woods; Andrew L. Lewis; Yiqing Tang; Michael Grass; Bradford J. Wood; Jean Francois H Geschwind

Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. (©) RSNA, 2015.


ieee international conference on biomedical robotics and biomechatronics | 2014

A prototype body-mounted MRI-compatible robot for needle guidance in shoulder arthrography

Reza Monfaredi; Reza Seifabadi; Iulian Iordachita; Raymond W. Sze; Nabile M. Safdar; Karun Sharma; Stanley T. Fricke; Axel Krieger; Kevin Cleary

A novel compact and lightweight patient-mounted MRI-compatible robot has been designed for MRI image-guided interventions. This robot is intended to enable MRI-guided needle placement as done in shoulder arthrography. The robot could make needle placement more accurate and simplify the current workflow by converting the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure (streamlined workflow all in MRI suite). The robot has 4 degrees of freedom (DOF), two for orientation of the needle and two for needle positioning. The mechanical design was based on several criteria including rigidity, MRI compatibility, compact design, sterilizability, and adjustability. The proposed workflow is discussed and initial MRI compatibility experiments are presented. The results show that artifacts in the region of interest are minimal and that MRI images of the shoulder were not adversely affected by placing the robot on a human volunteer.


Journal of Vascular and Interventional Radiology | 2016

Microvascular Perfusion Changes following Transarterial Hepatic Tumor Embolization.

Carmen Gacchina Johnson; Karun Sharma; E. Levy; David L. Woods; Aaron H. Morris; John Bacher; Andrew L. Lewis; Bradford J. Wood; Matthew R. Dreher

PURPOSE To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. MATERIALS AND METHODS Rabbit Vx2 liver tumors were embolized with 100-300-μm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3-5 per group; 18 total). RESULTS Mean microvascular density was 70 vessels/mm(2) ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31(+) structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. CONCLUSIONS Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy.


international conference of the ieee engineering in medicine and biology society | 2015

Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

Reza Monfaredi; Emmanuel Wilson; Raymond W. Sze; Karun Sharma; Bamshad Azizi; Iulian Iordachita; Kevin Cleary

A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robots workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.


IEEE Transactions on Biomedical Engineering | 2018

Multi-Imager Compatible, MR Safe, Remote Center of Motion Needle-Guide Robot

Dan Stoianovici; Changhan Jun; Sunghwan Lim; Pan Li; Doru Petrisor; Stanley T. Fricke; Karun Sharma; Kevin Cleary

We report the development of a new robotic system for direct image-guided interventions (DIGI; images acquired at the time of the intervention). The manipulator uses our previously reported pneumatic step motors and is entirely made of electrically nonconductive, nonmetallic, and nonmagnetic materials. It orients a needle-guide with two degrees of freedom (DoF) about a fulcrum point located below the guide using an innovative remote center of motion parallelogram type mechanism. The depth of manual needle insertion is preset with a third DoF, located remotely of the manipulator. Special consideration was given to the kinematic accuracy and the structural stiffness. The manipulator includes registration markers for image-to-robot registration. Based on the images, it may guide needles, drills, or other slender instruments to a target (OD < 10 mm). Comprehensive preclinical tests were performed. The manipulator is MR safe (ASTM F2503-13). Electromagnetic compatibility (EMC) testing (IEC 60601-1-2) of the system shows that it does not conduct or radiate EM emissions. The change in the signal to noise ratio of the MRI due to the presence and motion of the robot in the scanner is below 1%. The structural stiffness at the needle-guide is 33 N/mm. The angular accuracy and precision of the manipulator itself are 0.177° and 0.077°. MRI-guided targeting accuracy and precision in vitro were 1.71 mm and 0.51 mm, at an average target depth of ∼38 mm, with no adjustments. The system may be suitable for DIGI where


international symposium on biomedical imaging | 2014

Automatic labeling of liver veins in CT by probabilistic backward tracing.

Xin Kang; Qian Zhao; Karun Sharma; Raj Shekhar; Bradford J. Wood; Marius George Linguraru

{\text{1.07 + 0.0031}} \cdot \boldsymbol{d}


The Journal of Pediatrics | 2017

Comparison of Noninvasive High-Intensity Focused Ultrasound with Radiofrequency Ablation of Osteoid Osteoma

Karun Sharma; Pavel Yarmolenko; Haydar Celik; Avinash Eranki; Ari Partanen; Anilawan Smitthimedhin; Aerang Kim; Matthew E. Oetgen; Domiciano Santos; Janish Patel; Peter C.W. Kim

[mm] accuracy lateral to the needle (2D) or

Collaboration


Dive into the Karun Sharma's collaboration.

Top Co-Authors

Avatar

Bradford J. Wood

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Matthew R. Dreher

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Kevin Cleary

Children's National Medical Center

View shared research outputs
Top Co-Authors

Avatar

Ayele H. Negussie

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Vania Tacher

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Gacchina

National Institutes of Health

View shared research outputs
Researchain Logo
Decentralizing Knowledge