Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kenneth Tandjung is active.

Publication


Featured researches published by Kenneth Tandjung.


BMJ | 2013

Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis

Eliano Pio Navarese; Kenneth Tandjung; Bimmer E. Claessen; Felicita Andreotti; Mariusz Kowalewski; David E. Kandzari; Ron Waksman; Laura Mauri; Ian T. Meredith; Aloke V. Finn; Hyo Soo Kim; Jacek Kubica; Harry Suryapranata; Toni M. Aprami; Giuseppe Di Pasquale; Clemens von Birgelen; Elvin Kedhi

Objectives To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES). Design Network meta-analysis of randomised controlled trials. Data sources and study selection Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled trials comparing at least two of durable polymer sirolimus eluting stents (sirolimus-ES) and paclitaxel eluting stents (paclitaxel-ES), newer durable polymer everolimus eluting stents (everolimus-ES), Endeavor and Resolute zotarolimus eluting stents (zotarolimus-ES), and biodegradable polymer biolimus-ES. Primary outcomes Safety (death, myocardial infarction, definite or probable stent thrombosis) and efficacy (target lesion and target vessel revascularisation) assessed at up to one year and beyond. Results 60 randomised controlled trials were compared involving 63 242 patients with stable coronary artery disease or acute coronary syndrome treated with a DES. At one year, there were no differences in mortality among devices. Resolute and Endeavor zotarolimus-ES, everolimus-ES, and sirolimus-ES, but not biodegradable polymer biolimus-ES, were associated with significantly reduced odds of myocardial infarction (by 29-34%) compared with paclitaxel-ES. Compared with everolimus-ES, biodegradable polymer biolimus-ES were associated with significantly increased odds of myocardial infarction (by 29%), while Endeavor zotarolimus-ES and paclitaxel-ES were associated with significantly increased odds of stent thrombosis. All investigated DES were similar with regards to efficacy endpoints, except for Endeavor zotarolimus-ES and paclitaxel-ES, which were associated with significantly increased the odds of target lesion and target vessel revascularisations compared with other devices. Direction of results beyond one year did not diverge from the findings for up to one year follow-up. Bayesian probability curves showed a gradient in the magnitude of effect, with everolimus-ES and Resolute zotarolimus-ES offering the highest safety profiles. Conclusions The newer durable polymer everolimus-ES and Resolute zotarolimus-ES and the biodegradable polymer biolimus-ES maintain the efficacy of sirolimus-ES; however, for safety endpoints, differences become apparent, with everolimus-ES and Resolute zotarolimus-ES emerging as the safest stents to date.


The Lancet | 2014

Third-generation zotarolimus-eluting and everolimus-eluting stents in all-comer patients requiring a percutaneous coronary intervention (DUTCH PEERS): a randomised, single-blind, multicentre, non-inferiority trial

Clemens von Birgelen; Hanim Sen; Ming Kai Lam; Peter W. Danse; Gillian A.J. Jessurun; Raymond W.M. Hautvast; Gert van Houwelingen; Alexander Schramm; R. Melvyn Tjon Joe Gin; J. (Hans) W. Louwerenburg; Frits H.A.F. de Man; Martin G. Stoel; Marije M. Löwik; Gerard C.M. Linssen; Salah A.M. Saïd; Mark B. Nienhuis; Patrick M.J. Verhorst; Mounir W.Z. Basalus; Catharina Jacoba Maria Doggen; Kenneth Tandjung

BACKGROUND Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial. METHODS In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707. FINDINGS Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk difference 0·88%, 95% CI -1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group differences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events. INTERPRETATION Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. FUNDING Boston Scientific, Medtronic.


Jacc-cardiovascular Interventions | 2015

Clinical Events and Patient-Reported Chest Pain in All-Comers Treated With Resolute Integrity and Promus Element Stents : 2-Year Follow-Up of the DUTCH PEERS (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial (TWENTE II)

Hanim Sen; Ming Kai Lam; Marije M. Löwik; Peter W. Danse; Gillian A.J. Jessurun; K. Gert van Houwelingen; Rutger L. Anthonio; R. Melvyn Tjon Joe Gin; Raymond W.M. Hautvast; J. (Hans) W. Louwerenburg; Frits H.A.F. de Man; Martin G. Stoel; Liefke C. van der Heijden; Gerard C.M. Linssen; Maarten Joost IJzerman; Kenneth Tandjung; Carine J.M. Doggen; Clemens von Birgelen

OBJECTIVES This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts). BACKGROUND For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce. METHODS The DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial [TWENTE II]) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations. RESULTS The 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel-related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 [95% confidence interval: 1.05 to 3.39], p = 0.03). CONCLUSIONS During the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.


American Heart Journal | 2012

DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity (DUTCH PEERS): Rationale and study design of a randomized multicenter trial in a Dutch all-comers population

Kenneth Tandjung; Mounir W.Z. Basalus; Hanim Sen; Gillian A.J. Jessurun; Peter W. Danse; Martin G. Stoel; Gerard C.M. Linssen; Anita Derks; Ton T. van Loenhout; Mark B. Nienhuis; Raymond W.M. Hautvast; Clemens von Birgelen

BACKGROUND Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed. Promus Element (Boston Scientific, Natick, MA) and Resolute Integrity (Medtronic Vascular, Santa Rosa, CA) are 2 novel third-generation DES for which limited clinical data are available. Accordingly, we designed the current multicenter study to investigate in an all-comers population whether the clinical outcome is similar after stenting with Promus Element versus Resolute Integrity. METHODS DUTCH PEERS is a multicenter, prospective, single-blinded, randomized trial in a Dutch all-comers population. Patients with all clinical syndromes who require percutaneous coronary interventions with DES implantation are eligible. In these patients, the type of DES implanted will be randomized in a 1:1 ratio between Resolute Integrity versus Promus Element. The trial is powered based on a noninferiority hypothesis. For each stent arm, 894 patients will be enrolled, resulting in a total study population of 1,788 patients. The primary end point is the incidence of target vessel failure at 1-year follow-up. SUMMARY DUTCH PEERS is the first randomized multicenter trial with a head-to-head comparison of Promus Element and Resolute Integrity to investigate the safety and efficacy of these third-generation DES.


American Heart Journal | 2014

Comparison of 3 biodegradable polymer and durable polymer-based drug-eluting stents in all-comers (BIO-RESORT): Rationale and study design of the randomized TWENTE III multicenter trial

Ming Kai Lam; Hanim Sen; Kenneth Tandjung; K. Gert van Houwelingen; Arie G. de Vries; Peter W. Danse; Carl E. Schotborgh; Martijn Scholte; Marije M. Löwik; Gerard C.M. Linssen; Maarten Joost IJzerman; Jacobus Adrianus Maria van der Palen; Catharina Jacoba Maria Doggen; Clemens von Birgelen

AIM To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. METHODS AND RESULTS BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. CONCLUSIONS BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome.


American Journal of Cardiology | 2012

Comparison of Frequency of Periprocedural Myocardial Infarction in Patients With and Without Diabetes Mellitus to Those With Previously Unknown but Elevated Glycated Hemoglobin Levels (from the TWENTE Trial)

Kenneth Tandjung; K.G. van Houwelingen; Hanneke Jansen; Mounir W.Z. Basalus; Hanim Sen; Marije M. Löwik; Martin G. Stoel; J. (Hans) W. Louwerenburg; F.H.A.F. De Man; Gerard C.M. Linssen; Rogier Nijhuis; Mark B. Nienhuis; van der Jacobus Palen; Ronald P. Stolk; C. von Birgelen

In patients without a history of diabetes mellitus, increased levels of glycated hemoglobin (HbA1c) are associated with higher cardiovascular risk. The relation between undetected diabetes and clinical outcome after percutaneous coronary intervention is unknown. To investigate whether these patients may have an increased risk of periprocedural myocardial infarction (PMI), the most frequent adverse event after percutaneous coronary intervention, we assessed patients of the TWENTE trial (a randomized, controlled, second-generation drug-eluting stent trial) in whom HbA1c data were available. Patients were classified as known diabetics or patients without a history of diabetes who were subdivided into undetected diabetics (HbA1c ≥6.5%) and nondiabetics (HbA1c <6.5%). Systematic measurement of cardiac biomarkers and electrocardiographic assessment were performed. One-year clinical outcome was also compared. Of 626 patients, 44 (7%) were undetected diabetics, 181 (29%) were known diabetics, and 401 (64%) were nondiabetics. In undetected diabetics the PMI rate was higher than in nondiabetics (13.6% vs 3.7%, p = 0.01) and known diabetics (13.6% vs 6.1%, p = 0.11). Multivariate analysis adjusting for covariates confirmed a significantly higher PMI risk in undetected diabetics compared to nondiabetics (odds ratio 6.13, 95% confidence interval 2.07 to 18.13, p = 0.001) and known diabetics (odds ratio 3.73, 95% confidence interval 1.17 to 11.89, p = 0.03). After 1 year, target vessel MI rate was significantly higher in undetected diabetics (p = 0.02) than in nondiabetics, which was related mainly to differences in PMI. Target vessel failure was numerically larger in unknown diabetics than in nondiabetics, but this difference did not reach statistical significance (13.6% vs 8.0%, p = 0.25). In conclusion, undetected diabetics were shown to have an increased risk of PMI.


JAMA Cardiology | 2017

Five-year outcome after implantation of zotarolimus- and everolimus-eluting stents in randomized trial participants and nonenrolled eligible patients : A secondary analysis of a randomized clinical trial

Clemens von Birgelen; Liefke C. van der Heijden; Mounir W.Z. Basalus; Marlies M. Kok; Hanim Sen; Hans W. Louwerenburg; Gert van Houwelingen; Martin G. Stoel; Frits H.A.F. de Man; Gerard C.M. Linssen; Kenneth Tandjung; Carine J.M. Doggen; Job van der Palen; Marije M. Löwik

Importance Long-term follow-up after a clinical trial of 2 often-used, newer-generation drug-eluting stents (DESs) in a broad patient population is of interest. Comprehensive long-term outcome of eligible nonenrolled patients has never been reported. Objective To assess 5-year safety and efficacy of 2 newer-generation DESs in randomized participants with non–ST-elevation acute coronary syndromes or stable angina and to evaluate long-term outcomes of nonenrolled eligible patients treated with the same DESs. Design, Setting, and Participants The TWENTE (Real-World Endeavor Resolute vs Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated, patient-blinded, randomized, comparative DES trial that enrolled patients from June 18, 2008, to August 26, 2010. Most patients had non–ST-elevation acute coronary syndromes and complex lesions. Of all 1709 eligible patients, 1391 (81.4%) were treated in the TWENTE trial with zotarolimus-eluting (ZES, n = 697) or everolimus-eluting (EES, n = 694) cobalt-chromium stents. The remaining 318 eligible patients (18.6%) were not enrolled but underwent nonrandomized treatment with the same DESs. Data were analyzed from August 26, 2015, to October 11, 2016. Event rates (percentages) were derived from log-rank analysis and may differ from straightforward calculation (nominator/denominator). The 5-year follow-up of the TWENTE participants was prespecified in the trial protocol; that of the nonenrolled participants was ad hoc. Main Outcomes and Measures Target vessel failure (TVF), a composite of cardiac death, target vessel–related myocardial infarction, or target vessel revascularization. Results Of 1709 eligible participants, 1233 (72.1%) were men, 476 (27.9%) were women, and mean (SD) age was 64.6 (10.6) years. Among the 1370 of 1391 TWENTE trial participants (98.5% follow-up), TVF was similar between those in the ZES (16.1%) and EES (18.1%) groups (P = .36). Stent thrombosis rates were low: definite (7 of 697 [1.0%] vs 4 of 694 [0.6%]; P = .37) and occurred after more than 1 year in 3 (0.4%) with ZES vs 4 (0.6%) with EES (P = .69). The 318 nonenrolled eligible patients (308 patients [96.9%] of whom were followed up) were older and had more advanced disease than trial participants. Their TVF rate was higher than that of trial participants (71 of 318 [23.3%] vs 233 of 1391 [17.1%]; P = .02), which partly reflects a difference in cardiac mortality (23 of 318 [7.7%] vs 60 of 1391 [4.5%]; P = .03). Similar 5-year rates were found for myocardial infarction (91 of 1391 [6.7%] vs 22 of 318 [7.2%]; P = .80) and target vessel revascularization (129 of 1391 [9.7%] vs 34 of 318 [11.4%]; P = .36) between trial participants and nonenrolled eligible patients. In all eligible patients (ie, trial participants plus nonenrolled eligible patients), the TVF rate was only slightly higher than in trial participants only (18.3% vs 17.1%). Conclusions and Relevance Long-term outcome data from nonenrolled eligible patients support the validity of the TWENTE trial findings and present, with the trial, a strong case for the long-term safety and efficacy of the newer-generation DESs used. Trial Registration clinicaltrials.gov Identifier: NCT01066650


International Journal of Cardiology | 2016

Safety and efficacy of everolimus-eluting bioresorbable vascular scaffolds versus durable polymer everolimus-eluting metallic stents assessed at 1-year follow-up: A systematic review and meta-analysis of studies

Bertrand Njume Mukete; Liefke C. van der Heijden; Kenneth Tandjung; Hassan Baydoun; Kapil Yadav; Qusai Saleh; Carine J.M. Doggen; Nidal Abi Rafeh; Thierry H. Le Jemtel; Clemens von Birgelen

BACKGROUND The Absorb bioresorbable vascular scaffold (BVS) was developed to address long-term safety issues of metallic drug-eluting stents. However, it may be associated with an increased event risk during the first year. METHODS A systematic literature search was performed (in MEDLINE/PubMed, Cochrane CENTRAL, EMBASE, and scientific meeting abstracts) to identify studies that compared BVS and cobalt-chromium durable polymer everolimus-eluting stents (EES). For randomized clinical trials and non-randomized propensity score matched studies that reported 1-year outcome data, fixed/random-effects models were used to generate pooled estimates of outcomes, presented as odds ratios (OR) with 95%-confidence intervals (CI). RESULTS The 1-year follow-up data of 6 trials with 5588 patients were analyzed. A device-oriented composite endpoint (DOCE - cardiac death, target vessel myocardial infarction (MI), or target lesion revascularization (TLR)) was reached by 308 BVS or EES patients (195/3253 vs. 113/2315). Meta-analysis showed that patients who received BVS had an increased risk of MI (4.3% vs. 2.3%; OR:1.63, 95%-CI: 1.18-2.25, p<0.01) and definite-or-probable scaffold thrombosis (1.3% vs. 0.6%; OR:2.10, 95%-CI: 1.13-3.87, p=0.02). However, there was no significant between-group difference in risk of DOCE (6.0% vs. 4.9%; OR:1.19, 95%-CI: 0.94-1.52, p=0.16), cardiac death (0.8% vs. 0.7%; OR:1.14, 95%-CI: 0.54-2.39, p=0.73), or TLR (2.5% vs. 2.5%; OR: 0.98, 95%-CI:0.69-1.40, p=0.92). CONCLUSIONS During the first year of follow-up, patients treated with BVS had a higher incidence of MI and scaffold thrombosis. The risk of DOCE was not significantly different. As BVS may pay off later, future robust data on long-term clinical outcome will be of paramount importance.


Catheterization and Cardiovascular Interventions | 2012

Incidence of periprocedural myocardial infarction following stent implantation: Comparison between first- and second-generation drug-eluting stents

Kenneth Tandjung; Mounir W.Z. Basalus; Esther Muurman; Hans W. Louwerenburg; K. Gert van Houwelingen; Martin G. Stoel; Frits H.A.F. de Man; Hanneke Jansen; Jennifer Huisman; Gerard C.M. Linssen; Herman T. Droste; Mark B. Nienhuis; Clemens von Birgelen

Background: First‐ and second‐generation drug‐eluting stents (DES) differ in coating materials, which may influence the incidence of periprocedural myocardial infarction (PMI). Objective: To compare the incidence of PMI between first‐ and second‐generation DES, using the current Academic Research Consortium (ARC) definition of PMI. Methods: We assessed 800 patients treated with first‐ (Taxus Liberté or Endeavor) or second‐generation DES (Xience V or Resolute). Each DES group consisted of 200 consecutive patients, who were treated during the transition from first‐ to second‐generation DES. Routine peri‐interventional assessment of cardiac biomarkers was performed to compare the incidence of PMI between DES groups according to the updated definition by the ARC: 2x upper reference limit of creatine kinase (CK), confirmed by CK‐MB elevation. Results: In 800 patients, a total of 1,522 DES (363 Taxus; 385 Endeavor; 382 Xience V; 392 Resolute) were implanted to treat 1,232 lesions. Patient characteristics did not differ between groups. In patients receiving second‐generation DES, more multivessel percutaneous coronary interventions were performed (P = 0.01). The overall incidence of PMI was 4.75%. Between first‐ and second‐generation DES, there was no significant difference in PMI (5.5% vs. 4.0%; P = 0.29). In a multivariate analysis, only the total number of stents implanted (P < 0.001) and presentation with acute coronary syndrome (P = 0.02) were independent predictors of PMI. Conclusion: Using the revised ARC definition, we found no significant difference in PMI between first‐ and second‐generation DES. Overall, PMI occurred in 4.75%, which is 58% lower than with use of the historical PMI definition.


Catheterization and Cardiovascular Interventions | 2015

Clinical outcome of patients with implantation of second‐generation drug‐eluting stents in the right coronary ostium: Insights from 2‐year follow‐up of the TWENTE trial

Ming Kai Lam; Hanim Sen; Kenneth Tandjung; Marije M. Löwik; Mounir W.Z. Basalus; J.C. Mewes; Martin G. Stoel; K. Gert van Houwelingen; Gerard C.M. Linssen; Maarten Joost IJzerman; Catharina Jacoba Maria Doggen; Clemens von Birgelen

The aim of the present study was to assess the impact on clinical outcome of right coronary artery (RCA) ostial coverage with second‐generation drug‐eluting stents (DES).

Collaboration


Dive into the Kenneth Tandjung's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gerard C.M. Linssen

University Medical Center Groningen

View shared research outputs
Top Co-Authors

Avatar

Hanim Sen

Medisch Spectrum Twente

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ming Kai Lam

Medisch Spectrum Twente

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge