Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Marije M. Löwik is active.

Publication


Featured researches published by Marije M. Löwik.


The Lancet | 2014

Third-generation zotarolimus-eluting and everolimus-eluting stents in all-comer patients requiring a percutaneous coronary intervention (DUTCH PEERS): a randomised, single-blind, multicentre, non-inferiority trial

Clemens von Birgelen; Hanim Sen; Ming Kai Lam; Peter W. Danse; Gillian A.J. Jessurun; Raymond W.M. Hautvast; Gert van Houwelingen; Alexander Schramm; R. Melvyn Tjon Joe Gin; J. (Hans) W. Louwerenburg; Frits H.A.F. de Man; Martin G. Stoel; Marije M. Löwik; Gerard C.M. Linssen; Salah A.M. Saïd; Mark B. Nienhuis; Patrick M.J. Verhorst; Mounir W.Z. Basalus; Catharina Jacoba Maria Doggen; Kenneth Tandjung

BACKGROUND Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial. METHODS In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707. FINDINGS Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk difference 0·88%, 95% CI -1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group differences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events. INTERPRETATION Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. FUNDING Boston Scientific, Medtronic.


Jacc-cardiovascular Interventions | 2015

Clinical Events and Patient-Reported Chest Pain in All-Comers Treated With Resolute Integrity and Promus Element Stents : 2-Year Follow-Up of the DUTCH PEERS (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial (TWENTE II)

Hanim Sen; Ming Kai Lam; Marije M. Löwik; Peter W. Danse; Gillian A.J. Jessurun; K. Gert van Houwelingen; Rutger L. Anthonio; R. Melvyn Tjon Joe Gin; Raymond W.M. Hautvast; J. (Hans) W. Louwerenburg; Frits H.A.F. de Man; Martin G. Stoel; Liefke C. van der Heijden; Gerard C.M. Linssen; Maarten Joost IJzerman; Kenneth Tandjung; Carine J.M. Doggen; Clemens von Birgelen

OBJECTIVES This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts). BACKGROUND For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce. METHODS The DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial [TWENTE II]) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations. RESULTS The 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel-related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 [95% confidence interval: 1.05 to 3.39], p = 0.03). CONCLUSIONS During the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.


American Heart Journal | 2014

Comparison of 3 biodegradable polymer and durable polymer-based drug-eluting stents in all-comers (BIO-RESORT): Rationale and study design of the randomized TWENTE III multicenter trial

Ming Kai Lam; Hanim Sen; Kenneth Tandjung; K. Gert van Houwelingen; Arie G. de Vries; Peter W. Danse; Carl E. Schotborgh; Martijn Scholte; Marije M. Löwik; Gerard C.M. Linssen; Maarten Joost IJzerman; Jacobus Adrianus Maria van der Palen; Catharina Jacoba Maria Doggen; Clemens von Birgelen

AIM To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. METHODS AND RESULTS BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. CONCLUSIONS BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome.


American Journal of Cardiology | 2012

Comparison of Frequency of Periprocedural Myocardial Infarction in Patients With and Without Diabetes Mellitus to Those With Previously Unknown but Elevated Glycated Hemoglobin Levels (from the TWENTE Trial)

Kenneth Tandjung; K.G. van Houwelingen; Hanneke Jansen; Mounir W.Z. Basalus; Hanim Sen; Marije M. Löwik; Martin G. Stoel; J. (Hans) W. Louwerenburg; F.H.A.F. De Man; Gerard C.M. Linssen; Rogier Nijhuis; Mark B. Nienhuis; van der Jacobus Palen; Ronald P. Stolk; C. von Birgelen

In patients without a history of diabetes mellitus, increased levels of glycated hemoglobin (HbA1c) are associated with higher cardiovascular risk. The relation between undetected diabetes and clinical outcome after percutaneous coronary intervention is unknown. To investigate whether these patients may have an increased risk of periprocedural myocardial infarction (PMI), the most frequent adverse event after percutaneous coronary intervention, we assessed patients of the TWENTE trial (a randomized, controlled, second-generation drug-eluting stent trial) in whom HbA1c data were available. Patients were classified as known diabetics or patients without a history of diabetes who were subdivided into undetected diabetics (HbA1c ≥6.5%) and nondiabetics (HbA1c <6.5%). Systematic measurement of cardiac biomarkers and electrocardiographic assessment were performed. One-year clinical outcome was also compared. Of 626 patients, 44 (7%) were undetected diabetics, 181 (29%) were known diabetics, and 401 (64%) were nondiabetics. In undetected diabetics the PMI rate was higher than in nondiabetics (13.6% vs 3.7%, p = 0.01) and known diabetics (13.6% vs 6.1%, p = 0.11). Multivariate analysis adjusting for covariates confirmed a significantly higher PMI risk in undetected diabetics compared to nondiabetics (odds ratio 6.13, 95% confidence interval 2.07 to 18.13, p = 0.001) and known diabetics (odds ratio 3.73, 95% confidence interval 1.17 to 11.89, p = 0.03). After 1 year, target vessel MI rate was significantly higher in undetected diabetics (p = 0.02) than in nondiabetics, which was related mainly to differences in PMI. Target vessel failure was numerically larger in unknown diabetics than in nondiabetics, but this difference did not reach statistical significance (13.6% vs 8.0%, p = 0.25). In conclusion, undetected diabetics were shown to have an increased risk of PMI.


JAMA Cardiology | 2017

Five-year outcome after implantation of zotarolimus- and everolimus-eluting stents in randomized trial participants and nonenrolled eligible patients : A secondary analysis of a randomized clinical trial

Clemens von Birgelen; Liefke C. van der Heijden; Mounir W.Z. Basalus; Marlies M. Kok; Hanim Sen; Hans W. Louwerenburg; Gert van Houwelingen; Martin G. Stoel; Frits H.A.F. de Man; Gerard C.M. Linssen; Kenneth Tandjung; Carine J.M. Doggen; Job van der Palen; Marije M. Löwik

Importance Long-term follow-up after a clinical trial of 2 often-used, newer-generation drug-eluting stents (DESs) in a broad patient population is of interest. Comprehensive long-term outcome of eligible nonenrolled patients has never been reported. Objective To assess 5-year safety and efficacy of 2 newer-generation DESs in randomized participants with non–ST-elevation acute coronary syndromes or stable angina and to evaluate long-term outcomes of nonenrolled eligible patients treated with the same DESs. Design, Setting, and Participants The TWENTE (Real-World Endeavor Resolute vs Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated, patient-blinded, randomized, comparative DES trial that enrolled patients from June 18, 2008, to August 26, 2010. Most patients had non–ST-elevation acute coronary syndromes and complex lesions. Of all 1709 eligible patients, 1391 (81.4%) were treated in the TWENTE trial with zotarolimus-eluting (ZES, n = 697) or everolimus-eluting (EES, n = 694) cobalt-chromium stents. The remaining 318 eligible patients (18.6%) were not enrolled but underwent nonrandomized treatment with the same DESs. Data were analyzed from August 26, 2015, to October 11, 2016. Event rates (percentages) were derived from log-rank analysis and may differ from straightforward calculation (nominator/denominator). The 5-year follow-up of the TWENTE participants was prespecified in the trial protocol; that of the nonenrolled participants was ad hoc. Main Outcomes and Measures Target vessel failure (TVF), a composite of cardiac death, target vessel–related myocardial infarction, or target vessel revascularization. Results Of 1709 eligible participants, 1233 (72.1%) were men, 476 (27.9%) were women, and mean (SD) age was 64.6 (10.6) years. Among the 1370 of 1391 TWENTE trial participants (98.5% follow-up), TVF was similar between those in the ZES (16.1%) and EES (18.1%) groups (P = .36). Stent thrombosis rates were low: definite (7 of 697 [1.0%] vs 4 of 694 [0.6%]; P = .37) and occurred after more than 1 year in 3 (0.4%) with ZES vs 4 (0.6%) with EES (P = .69). The 318 nonenrolled eligible patients (308 patients [96.9%] of whom were followed up) were older and had more advanced disease than trial participants. Their TVF rate was higher than that of trial participants (71 of 318 [23.3%] vs 233 of 1391 [17.1%]; P = .02), which partly reflects a difference in cardiac mortality (23 of 318 [7.7%] vs 60 of 1391 [4.5%]; P = .03). Similar 5-year rates were found for myocardial infarction (91 of 1391 [6.7%] vs 22 of 318 [7.2%]; P = .80) and target vessel revascularization (129 of 1391 [9.7%] vs 34 of 318 [11.4%]; P = .36) between trial participants and nonenrolled eligible patients. In all eligible patients (ie, trial participants plus nonenrolled eligible patients), the TVF rate was only slightly higher than in trial participants only (18.3% vs 17.1%). Conclusions and Relevance Long-term outcome data from nonenrolled eligible patients support the validity of the TWENTE trial findings and present, with the trial, a strong case for the long-term safety and efficacy of the newer-generation DESs used. Trial Registration clinicaltrials.gov Identifier: NCT01066650


American Heart Journal | 2016

Impact of severe lesion calcification on clinical outcome of patients with stable angina, treated with newer generation permanent polymer-coated drug-eluting stents: A patient-level pooled analysis from TWENTE and DUTCH PEERS (TWENTE II)

Jennifer Huisman; Liefke C. van der Heijden; Marlies M. Kok; Peter W. Danse; Gillian A.J. Jessurun; Martin G. Stoel; K. Gert van Houwelingen; Marije M. Löwik; Raymond W.M. Hautvast; Maarten Joost IJzerman; Catharina Jacoba Maria Doggen; Clemens von Birgelen

BACKGROUND The outcome of percutaneous coronary intervention with newer generation permanent polymer-coated drug-eluting stents (DES) in patients with severely calcified lesions is greatly unknown. We assessed the impact of severe lesion calcification on clinical outcome in patients with stable angina who underwent percutaneous coronary intervention with newer generation DES. METHODS TWENTE and DUTCH PEERS randomized trials enrolled 1423 patients with stable angina, who were categorized into patients with versus without severe target lesion calcification. A patient-level pooled analysis assessed clinical outcome, including target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization (TVR). RESULTS Patients with severe calcification (n = 342) were older (66.6 ± 9.1 vs 64.2 ± 9.8 years, P < .001) and had more diabetes (25.7% vs 20.4%, P = .04) than other patients (n = 1081). Patients with calcified lesions had higher rates of TVF (16.4% vs 9.8%, pLogrank = .001), cardiac death (4.4% vs 1.5%, P = .03), target vessel myocardial infarction (7.6% vs 3.4%, P = .001), and definite stent thrombosis (1.8% vs 0.4%, P = .02). Multivariate analysis demonstrated that severe calcification was an independent risk factor of 2-year TVF (HR 1.42, 95% CI: 1.02-1.99, pLogrank = .04); landmark analysis showed that this was based on a difference during the first year (periprocedural: 5.8% vs. 3.1%, pLogrank = .02; first year: 7.5% vs. 3.8%, pLogrank = .007; second year: 4.1% vs. 3.3%, pLogrank = .54). CONCLUSION In patients with stable angina, severe target lesion calcification is associated with an increased risk of adverse cardiovascular events following treatment with newer generation permanent polymer-coated DES. This increase in risk is restricted to the first year of follow-up, which is an encouraging finding.


Catheterization and Cardiovascular Interventions | 2015

Clinical outcome of patients with implantation of second‐generation drug‐eluting stents in the right coronary ostium: Insights from 2‐year follow‐up of the TWENTE trial

Ming Kai Lam; Hanim Sen; Kenneth Tandjung; Marije M. Löwik; Mounir W.Z. Basalus; J.C. Mewes; Martin G. Stoel; K. Gert van Houwelingen; Gerard C.M. Linssen; Maarten Joost IJzerman; Catharina Jacoba Maria Doggen; Clemens von Birgelen

The aim of the present study was to assess the impact on clinical outcome of right coronary artery (RCA) ostial coverage with second‐generation drug‐eluting stents (DES).


American Heart Journal | 2015

Three-year clinical outcome of patients with bifurcation treatment with second-generation Resolute and Xience V stents in the randomized TWENTE trial

Ming Kai Lam; Hanim Sen; K. Gert van Houwelingen; Marije M. Löwik; Liefke C. van der Heijden; Marlies M. Kok; Frits H.A.F. de Man; Gerard C.M. Linssen; Kenneth Tandjung; Carine J.M. Doggen; Clemens von Birgelen

BACKGROUND Only limited data from large randomized clinical trials have been published on the long-term performance of second-generation drug-eluting stents in bifurcation lesions. METHODS We investigated in patients in the randomized TWENTE trial the long-term safety and efficacy of treating bifurcation lesions with 2 widely applied second-generation drug-eluting stents, the zotarolimus-eluting Resolute stent (Medtronic Inc, Santa Rosa, CA) and the everolimus-eluting Xience V stent (Abbott Vascular, Santa Clara, CA). Three-year follow-up was available in 99.3%. Patients were categorized into treatment for ≥1 bifurcation lesion versus treatment for nonbifurcation lesions only. RESULTS Among the 1,391 patients of the TWENTE trial, 362 (26%) were treated for bifurcation lesions. At 3-year follow-up, target-vessel failure did not differ between patients treated for bifurcation versus nonbifurcation lesions (13.1% vs 12.6%; P = .84), whereas the periprocedural myocardial infarction rate was higher in patients with bifurcation lesions (6.9% vs 3.1%; P < .01). Of the 362 patients with bifurcation lesion treatment, 179 (49.4%) were treated with Resolute and 183 (50.6%) with Xience V. There was no significant difference in target-vessel failure between the Resolute and Xience V groups with bifurcation treatment (13.6% vs 12.6%; P = .78), and their incidence of definite-or-probable stent thrombosis was low and similar (1.1% vs 0.5%, respectively; P = .62). CONCLUSION Despite a significant difference in periprocedural myocardial infarction, 3-year clinical outcome after implantation of second-generation stents was favorable and similar for patients with and without bifurcation lesions. In addition, we observed no difference in long-term clinical outcome after bifurcation lesion treatment with Resolute and Xience V stents.


Catheterization and Cardiovascular Interventions | 2015

Three-year clinical outcome after treatment of chronic total occlusions with second-generation drug-eluting stents in the TWENTE trial

K. Gert van Houwelingen; Hanim Sen; Ming Kai Lam; Kenneth Tandjung; Marije M. Löwik; Frits H.A.F. de Man; J. (Hans) W. Louwerenburg; Martin G. Stoel; Marc Hartmann; Gerard C.M. Linssen; Carine J.M. Doggen; Clemens von Birgelen

To compare long‐term outcome of patients treated for chronic total occlusion (CTO) lesions versus patients treated for non‐CTO lesions only.


Eurointervention | 2017

Three-year safety and efficacy of treating all-comers with newer-generation Resolute Integrity or PROMUS Element stents in the randomised Dutch PEERS (TWENTE II) trial

Liefke C. van der Heijden; Marlies M. Kok; Marije M. Löwik; Peter W. Danse; Gillian A.J. Jessurun; Raymond W.M. Hautvast; Gert van Houwelingen; Martin G. Stoel; Marc Hartmann; Gerard C.M. Linssen; Carine J.M. Doggen; Clemens von Birgelen

AIMS The aim of this report was to assess the three-year safety and efficacy of implanting newer-generation Resolute Integrity zotarolimus-eluting stents (ZES) versus PROMUS Element everolimus-eluting stents (EES) in all-comers. METHODS AND RESULTS In the randomised, multicentre, investigator-initiated DUTCH PEERS trial, a total of 1,811 all-comers were 1:1 randomly assigned to treatment with ZES versus EES. A total of 1,293 patients (72%) were treated for complex lesions and 455 patients (25%) were treated for multiple lesions. The primary endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction or target vessel revascularisation. Adverse clinical events were independently adjudicated. Three-year follow-up data were obtained in 1,807 patients (99.8%, four withdrawals). Both the ZES and EES groups showed favourable outcomes with a similar incidence of TVF (10.7% vs. 10.3%; pLog-rank=0.77) and the individual components thereof: cardiac death (3.2% vs. 3.1%; pLog-rank=0.87), target vessel-related myocardial infarction (2.8% vs. 2.2%; pLog-rank=0.44) and target vessel revascularisation (6.0% vs. 6.2%; pLog-rank=0.87). In addition, the incidence of definite or probable stent thrombosis was similar for patients treated with ZES versus EES (1.4% vs. 1.1%; pLog-rank=0.66). CONCLUSIONS The safety and efficacy of treating all-comers with newer-generation Resolute Integrity and PROMUS Element stents was found to be extended up to three years.

Collaboration


Dive into the Marije M. Löwik's collaboration.

Top Co-Authors

Avatar

Gerard C.M. Linssen

University Medical Center Groningen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hanim Sen

Medisch Spectrum Twente

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge