Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Keshthra Satchithananda is active.

Publication


Featured researches published by Keshthra Satchithananda.


Journal of Bone and Joint Surgery, American Volume | 2012

Pseudotumors in Association with Well-functioning Metal-on-metal Hip Prostheses: A Case-control Study Using Three-dimensional Computed Tomography and Magnetic Resonance Imaging

A. J. Hart; Keshthra Satchithananda; Alexander D Liddle; Shiraz Sabah; Donald McRobbie; Johann Henckel; Justin Cobb; John A. Skinner; Adam Mitchell

INTRODUCTION Many papers have been published recently on the subject of pseudotumors surrounding metal-on-metal hip resurfacing and replacement prostheses. These pseudotumors are sterile, inflammatory lesions within the periprosthetic tissues and have been variously termed masses, cysts, bursae, collections, or aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). The prevalence of pseudotumors in patients with a well-functioning metal-on-metal hip prosthesis is not well known. The purpose of this study was to quantify the prevalence of pseudotumors adjacent to well-functioning and painful metal-on-metal hip prostheses, to characterize these lesions with use of magnetic resonance imaging, and to assess the relationship between their presence and acetabular cup position with use of three-dimensional computed tomography. METHODS We performed a case-control study to compare the magnetic resonance imaging findings of patients with a well-functioning unilateral metal-on-metal hip prosthesis and patients with a painful prosthesis (defined by either revision arthroplasty performed because of unexplained pain or an Oxford hip score of <30 of 48 possible points). Thirty patients with a painful hip prosthesis and twenty-eight controls with a well-functioning prosthesis were recruited consecutively. All patients also underwent computed tomography to assess the position of the acetabular component. RESULTS Thirty-four patients were diagnosed with a pseudotumor. However, the prevalence of pseudotumors in patients with a painful hip (seventeen of thirty, 57%) was not significantly different from the prevalence in the control group (seventeen of twenty-eight, 61%). No objective differences in pseudotumor characteristics between the groups were identified. No clear association between the presence of a pseudotumor and acetabular component position was identified. The Oxford hip score in the group with a painful hip (mean, 20.2; 95% confidence interval [CI], 12.7 to 45.8) was poorer than that in the control group (mean, 41.2; 95% CI, 18.5 to 45.8; p ≤ 0.0001). CONCLUSIONS A periprosthetic cystic pseudotumor was diagnosed commonly (in thirty-four [59%] of the entire study cohort) with use of metal artifact reduction sequence (MARS) magnetic resonance imaging in this series of patients with a metal-on-metal hip prosthesis. The prevalence of pseudotumors was similar in patients with a well-functioning hip prosthesis and patients with a painful hip. Pseudotumors were also diagnosed commonly in patients with a well-positioned acetabular component. Although magnetic resonance imaging is useful for surgical planning, the presence of a cystic pseudotumor may not necessarily indicate the need for revision arthroplasty. Further correlation of clinical and imaging data is needed to determine the natural history of pseudotumors to guide clinical practice.


Acta Orthopaedica | 2014

A comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty.

Imran A Siddiqui; Shiraz Sabah; Keshthra Satchithananda; Adrian Lim; Suzie Cro; Johann Henckel; John Skinner; Alister Hart

Background and purpose — Metal artifact reduction sequence (MARS) MRI and ultrasound scanning (USS) can both be used to detect pseudotumors, abductor muscle atrophy, and tendinous pathology in patients with painful metal-on-metal (MOM) hip arthroplasty. We wanted to determine the diagnostic test characteristics of USS using MARS MRI as a reference for detection of pseudotumors and muscle atrophy. Patients and methods — We performed a prospective cohort study to compare MARS MRI and USS findings in 19 consecutive patients with unilateral MOM hips. Protocolized USS was performed by consultant musculoskeletal radiologists who were blinded regarding clinical details. Reports were independently compared with MARS MRI, the imaging gold standard, to calculate predictive values. Results — The prevalence of pseudotumors on MARS MRI was 68% (95% CI: 43–87) and on USS it was 53% (CI: 29–76). The sensitivity of USS in detecting pseudotumors was 69% (CI 39–91) and the specificity was 83% (CI: 36–97). The sensitivity of detection of abductor muscle atrophy was 47% (CI: 24–71). In addition, joint effusion was detected in 10 cases by USS and none were seen by MARS MRI. Interpretation — We found a poor agreement between USS and MARS MRI. USS was inferior to MARS MRI for detection of pseudotumors and muscle atrophy, but it was superior for detection of joint effusion and tendinous pathologies. MARS MRI is more advantageous than USS for practical reasons, including preoperative planning and longitudinal comparison.


American Journal of Roentgenology | 2013

The Efficacy of Axillary Ultrasound in the Detection of Nodal Metastasis in Breast Cancer

Belinda Lee; Adrian Lim; Jonathan Krell; Keshthra Satchithananda; R. Charles Coombes; Jacqueline S. Lewis; Justin Stebbing

OBJECTIVE Recent reports indicate a lack of survival benefit for axillary lymph node dissection (ALND) versus sentinel lymph node biopsy in early breast cancer. To study this issue further, we assessed the accuracy and effectiveness of ultrasound examination in detecting axillary nodal involvement in breast cancer patients with the aim of refining our current clinical pathways. MATERIALS AND METHODS Ultrasound data were collected from breast cancer cases over 3 years. Images were reviewed by experienced radiologists and the following characteristics were assessed: size, morphology, hyperechoic hilum, and cortical thickness of the ipsilateral axillary nodes. The findings were correlated with histologic outcomes after ALND. RESULTS Two hundred twenty-four cases were included in the analysis, 113 (50.4%) of which had evidence of metastatic nodal involvement at final histology. Of these 113 cases, ultrasound findings for 59 (52.2%) were positive. The overall positive predictive value of ultrasound for detecting metastatic nodal involvement measured 0.81. The negative predictive value was 0.60. The sensitivity was 53.7%; specificity, 85.1%; and accuracy, 67.9%. The ultrasound morphologic lymph node features with the greatest correlation with malignancy were the absence of a hyperechoic hilum (p = 0.003) and increased cortical thickness (p = 0.03). Patients with a metastatic nodal burden density of at least 20% were more likely to have abnormal findings on axillary ultrasound examination (p = 0.009). CONCLUSION Axillary ultrasound has a low negative predictive value and negative ultrasound results do not exclude axillary node metastases with sufficient sensitivity to justify its routine clinical use. Clinical pathways need to consider an evidence-based approach, focusing on the criteria by which we select breast cancer patients for ALND.


European Journal of Radiology | 2013

Evaluating automated dynamic contrast enhanced wrist 3T MRI in healthy volunteers: one-year longitudinal observational study.

Anshul Rastogi; Olga Kubassova; Lada V. Krasnosselskaia; Adrian Lim; Keshthra Satchithananda; Mikael Boesen; Michael Binks; Joseph V. Hajnal; Peter C. Taylor

RATIONAL AND OBJECTIVE Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so as to differentiate changes induced by treatment from the inherent variability of perfusion measures. The objective of this study was to test a pixel-by-pixel parametric map based approach for analysis of DCE-MRI (Dynamika) and to investigate the variability in signal characteristics over time in healthy controls using longitudinally acquired images. MATERIALS AND METHODS 10 healthy volunteers enrolled, dominant wrists were imaged with contrast enhanced 3T MRI at baseline, week 12, 24 and 52 and scored with RAMRIS, DCE-MRI was analysed using a novel quantification parametric map based approach. Radiographs were obtained at baseline and week 52 and scored using modified Sharp van der Heidje method. RAMRIS scores and dynamic MRI measures were correlated. RESULTS No erosions were seen on radiographs, whereas MRI showed erosion-like changes, low grade bone marrow oedema and low-moderate synovial enhancement. The DCE-MRI parameters were stable (baseline scores, variability) (mean±st.dev); in whole wrist analysis, MEmean (1.3±0.07, -0.08±0.1 at week 24) and IREmean (0.008±0.004, -0.002±0.005 at week 12 and 24). In the rough wrist ROI, MEmean (1.2±0.07, 0.04±0.02 at week 52) and IREmean (0.001±0.0008, 0.0006±0.0009 at week 52) and precise wrist ROI, MEmean (1.2±0.09, 0.04±0.04 at week 52) and IREmean (0.001±0.0008, 0.0008±0.001 at week 24 and 52). The Dynamic parameters obtained using fully automated analysis demonstrated strong, statistically significant correlations with RAMRIS synovitis scores. CONCLUSION The study demonstrated that contrast enhancement does occur in healthy volunteers but the inherent variability of perfusion measures obtained with quantitative DCE-MRI method is low and stable, suggesting its suitability for longitudinal studies of inflammatory arthritis. These results also provide important information regarding potential cut-off levels for imaging remission goals in patients with RA using both RAMRIS and DCE-MRI extracted parametric parameters.


Rheumatology | 2014

Night-time immobilization of the distal interphalangeal joint reduces pain and extension deformity in hand osteoarthritis

F E Watt; Donna Kennedy; Katharine Carlisle; Andrew Freidin; Richard Szydlo; Lesley Honeyfield; Keshthra Satchithananda; Tonia L. Vincent

Objective. DIP joint OA is common but has few cost-effective, evidence-based interventions. Pain and deformity [radial or ulnar deviation of the joint or loss of full extension (extension lag)] frequently lead to functional and cosmetic issues. We investigated whether splinting the DIP joint would improve pain, function and deformity. Methods. A prospective, radiologist-blinded, non-randomized, internally controlled trial of custom splinting of the DIP joint was carried out. Twenty-six subjects with painful, deforming DIP joint hand OA gave written, informed consent. One intervention joint and one control joint were nominated. A custom gutter splint was worn nightly for 3 months on the intervention joint, with clinical and radiological assessment at baseline, 3 and 6 months. Differences in the change were compared by the Wilcoxon signed rank test. Results. The median average pain at baseline was similar in the intervention (6/10) and control joints (5/10). Average pain (primary outcome measure) and worst pain in the intervention joint were significantly lower at 3 months compared with baseline (P = 0.002, P = 0.02). Differences between intervention and control joint average pain reached significance at 6 months (P = 0.049). Extension lag deformity was significantly improved in intervention joints at 3 months and in splinted joints compared with matched contralateral joints (P = 0.016). Conclusion. Short-term night-time DIP joint splinting is a safe, simple treatment modality that reduces DIP joint pain and improves extension of the digit, and does not appear to give rise to non-compliance, increased stiffness or joint restriction. Trial registration: clinical trials.gov, http://clinicaltrials.gov, NCT01249391.


Clinical Radiology | 2013

Cross-sectional imaging of the metal-on-metal hip prosthesis: the London ultrasound protocol.

I.A. Siddiqui; Shiraz A. Sabah; Keshthra Satchithananda; Adrian Lim; Johann Henckel; John A. Skinner; A. J. Hart

Cross-sectional imaging of the metal-on-metal hip prosthesis: The London ultrasound protocol I.A. Siddiqui , S.A. Sabah , K. Satchithananda , A.K. Lim , J. Henckel , J.A. Skinner , A.J. Hart a,* a Institute of Orthopaedic and Musculoskeletal Science, University College London, The Royal National Orthopaedic Hospital, London, UK Department of Radiology, Imperial College Healthcare NHS Trust, Imperial College London, Charing Cross Hospital, London, UK


British Journal of Radiology | 2017

Enhanced pre-operative axillary staging using intradermal microbubbles and contrast-enhanced ultrasound to detect and biopsy sentinel lymph nodes in breast cancer: a potential replacement for axillary surgery

Karina Cox; Sian Taylor-Phillips; Nisha Sharma; Jennifer Weeks; Philippa Mills; Ali Sever; Adrian Lim; Isobel Haigh; Mohamed Hashem; Tania de Silva; Keshthra Satchithananda; Meng-Xing Tang; Matthew G. Wallis

OBJECTIVE To compare the experience of four UK Centres in the use of intradermal microbubbles and contrast enhanced ultrasound (CEUS) to pre-operatively identify and biopsy sentinel lymph nodes (SLN) in patients with breast cancer. METHODS In all centres, breast cancer patients had a microbubble/CEUS SLN core biopsy prior to axillary surgery and patients in Centres 1 and 2 had a normal greyscale axillary ultrasound. Data were collected between 2010 and 2016; 1361 from Centre 1 (prospective, sequential), 376 from Centre 2 (retrospective, sequential), 121 from Centre 3 (retrospective, selected) and 48 from Centre 4 (prospective, selected). RESULTS SLN were successfully core biopsied in 80% (Centre 1), 79.6% (Centre 2), 77.5% (Centre 3) and 88% (Centre 4). The sensitivities to identify all SLN metastases were 46.9% [95% confidence intervals (CI) (39.4-55.1)], 52.5% [95% CI (39.1-65.7)], 46.4% [95% CI (27.5-66.1)] and 45.5% [95% CI (16.7-76.6)], respectively. The specificities were 99.7% [95% CI (I98.9-100)], 98.1% [95% CI (94.5-99.6)], 100% [95% CI (93.2-100%)] and 96.3% [95% CI (81-99.9)], respectively.The negative predictive values were 87.0% [95% CI (84.3-89.3)], 84.5% [95% CI (78.4-89.5)], 86.9% [95% CI (82.4-90.3)] and 86.2% [95% CI (78.4-91.5)], respectively. At Centres 1 and 2, 12/730 (1.6%) and 7/181 (4%), respectively, of patients with a benign microbubble/CEUS SLN core biopsy had two or more lymph node (LN) macrometastases found at the end of primary surgical treatment. CONCLUSION The identification and biopsy of SLN using CEUS is a reproducible technique. Advances in knowledge: In the era of axillary conservation, microbubble/CEUS SLN core biopsy has the potential to succeed surgical staging of the axilla.


Orthopade | 2014

Erratum zu: Magnetresonanztomographische Untersuchungen bei Problemen mit Metall-auf-Metall-Implantaten

T.M. Parsons; Keshthra Satchithananda; R. Berber; Siddiqui Ia; Robinson E; Alister Hart


Archive | 2014

Can we substitute MARS MRI with CT

Elizabeth Robinson; Johann Henckel; Shiraz Sabah; Keshthra Satchithananda; John Skinner; Alister Hart


Orthopaedic Proceedings | 2012

An MRI Classification of Lesions Around Metal-on-Metal Hip Replacements

Alister Hart; Keshthra Satchithananda; Johann Henckel; Justin Cobb; Shiraz Sabah; John Skinner; Adam Mitchell

Collaboration


Dive into the Keshthra Satchithananda's collaboration.

Top Co-Authors

Avatar

Adrian Lim

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

Johann Henckel

Royal National Orthopaedic Hospital

View shared research outputs
Top Co-Authors

Avatar

Alister Hart

University of Huddersfield

View shared research outputs
Top Co-Authors

Avatar

Shiraz Sabah

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

John Skinner

University College London

View shared research outputs
Top Co-Authors

Avatar

A. J. Hart

Charing Cross Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John A. Skinner

Royal National Orthopaedic Hospital

View shared research outputs
Top Co-Authors

Avatar

Justin Cobb

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

Alexander D Liddle

Imperial College Healthcare

View shared research outputs
Researchain Logo
Decentralizing Knowledge