Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kim-Lien Nguyen is active.

Publication


Featured researches published by Kim-Lien Nguyen.


Magnetic Resonance in Medicine | 2016

Safety and technique of ferumoxytol administration for MRI.

Shreyas S. Vasanawala; Kim-Lien Nguyen; Michael D. Hope; Mellena D. Bridges; Thomas A. Hope; Scott B. Reeder; Mustafa R. Bashir

Ferumoxytol is an ultrasmall superparamagnetic iron oxide agent marketed for the treatment of anemia. There has been increasing interest in its properties as an MRI contrast agent as well as greater awareness of its adverse event profile. This mini‐review summarizes the current state of knowledge of the risks of ferumoxytol and methods of administration. Magn Reson Med 75:2107–2111, 2016.


Clinical Radiology | 2016

Cardiovascular MRI with ferumoxytol

John Paul Finn; Kim-Lien Nguyen; Fei Han; Ziwu Zhou; Isidro B. Salusky; Ihab Ayad; Peng Hu

The practice of contrast-enhanced magnetic resonance angiography (CEMRA) has changed significantly in the span of a decade. Concerns regarding gadolinium (Gd)-associated nephrogenic systemic fibrosis in those with severely impaired renal function spurred developments in low-dose CEMRA and non-contrast MRA as well as efforts to seek alternative MR contrast agents. Originally developed for MR imaging use, ferumoxytol (an ultra-small superparamagnetic iron oxide nanoparticle), is currently approved by the US Food and Drug Administration for the treatment of iron deficiency anaemia in adults with renal disease. Since its clinical availability in 2009, there has been rising interest in the scientific and clinical use of ferumoxytol as an MR contrast agent. The unique physicochemical and pharmacokinetic properties of ferumoxytol, including its long intravascular half-life and high r1 relaxivity, support a spectrum of MRI applications beyond the scope of Gd-based contrast agents. Moreover, whereas Gd is not found in biological systems, iron is essential for normal metabolism, and nutritional iron deficiency poses major public health challenges worldwide. Once the carbohydrate shell of ferumoxytol is degraded, the elemental iron at its core is incorporated into the reticuloendothelial system. These considerations position ferumoxytol as a potential game changer in the field of CEMRA and MRI. In this paper, we aim to summarise our experience with the cardiovascular applications of ferumoxytol and provide a brief synopsis of ongoing investigations on ferumoxytol-enhanced MR applications.


Journal of Magnetic Resonance Imaging | 2016

Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm

Jiaxin Shao; Stanislas Rapacchi; Kim-Lien Nguyen; Peng Hu

To develop an accurate and precise myocardial T1 mapping technique using an inversion recovery spoiled gradient echo readout at 3.0 Tesla (T).


European Journal of Echocardiography | 2014

Safety and tolerability of regadenoson CMR.

Kim-Lien Nguyen; W. Patricia Bandettini; Sujata M Shanbhag; Steve W. Leung; Joel R Wilson; Andrew E. Arai

Aims Knowledge of adverse events associated with regadenoson perfusion cardiac magnetic resonance (CMR) and patient tolerability has implications for patient safety and staff training. We sought to assess the safety and tolerability of regadenoson stress CMR. Materials and methods A group of 728 consecutive patients (median age 58, 44% female) and 25 normal volunteers (median age 21, 24% female) were recruited from August 2009 to March 2012 using a prospective, cross-sectional study design. Subjects were stressed using fixed-dose regadenoson and imaged using a 1.5T MRI scanner. Symptoms and adverse events including death, myocardial infarction (MI), ventricular tachycardia (VT)/ventricular fibrillation (VF), hospitalization, arrhythmias, and haemodynamic stability were assessed. Results There were no occurrences of death, MI, VT/VF, high-grade atrioventricular block, or stress-induced atrial fibrillation. Notable adverse events included one case of bronchospasm and one case of heart failure exacerbation resulting in hospitalization. The most common symptoms in patients were dyspnoea (30%, n = 217), chest discomfort (27%, n = 200), and headache (15%, n = 111). There was minimal change between baseline and peak systolic and diastolic blood pressure in both patients and volunteers (P > 0.05). A blunted heart rate response to regadenoson was noted in patients with body mass index (BMI) ≥30 kg/m2 (P < 0.001), and diabetes (P = 0.001). Conclusions Regadenoson CMR is well tolerated and can be performed safely with few adverse events.


Journal of Magnetic Resonance Imaging | 2017

MRI with ferumoxytol: A single center experience of safety across the age spectrum

Kim-Lien Nguyen; Takegawa Yoshida; Fei Han; Ihab Ayad; Brian Reemtsen; Isidro B. Salusky; Gary Satou; Peng Hu; J. Paul Finn

To summarize our single‐center safety experience with the off‐label use of ferumoxytol for magnetic resonance imaging (MRI) and to compare the effects of ferumoxytol on monitored physiologic indices in patients under anesthesia with those of gadofosveset trisodium.


Journal of Magnetic Resonance Imaging | 2015

Instantaneous signal loss simulation (InSiL): An improved algorithm for myocardial T1 mapping using the MOLLI sequence

Jiaxin Shao; Kim-Lien Nguyen; Yutaka Natsuaki; Bruce S Spottiswoode; Peng Hu

To propose a T1 mapping algorithm for the modified Look‐Locker inversion‐recovery (MOLLI) sequence that can improve T1 estimation accuracy.


Magnetic Resonance in Medicine | 2017

Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

Fei Han; Ziwu Zhou; Eric Han; Yu Gao; Kim-Lien Nguyen; J. Paul Finn; Peng Hu

To develop and validate a cardiac‐respiratory self‐gating strategy for the recently proposed multiphase steady‐state imaging with contrast enhancement (MUSIC) technique.


American Journal of Physiology-heart and Circulatory Physiology | 2017

Aerobic exercise in anthracycline-induced cardiotoxicity: a systematic review of current evidence and future directions

Joseph J. Chen; Pei-Tzu Wu; Holly R. Middlekauff; Kim-Lien Nguyen

Cancer and cardiovascular disease are major causes of morbidity and mortality worldwide. Older cancer patients often wrestle with underlying heart disease during cancer therapy, whereas childhood cancer survivors are living long enough to face long-term unintended cardiac consequences of cancer therapies, including anthracyclines. Although effective and widely used, particularly in the pediatric population, anthracycline-related side effects including dose-dependent association with cardiac dysfunction limit their usage. Currently, there is only one United States Food and Drug Administration-approved drug, dexrazoxane, available for the prevention and mitigation of cardiotoxicity related to anthracycline therapy. While aerobic exercise has been shown to reduce cardiovascular complications in multiple diseases, its role as a therapeutic approach to mitigate cardiovascular consequences of cancer therapy is in its infancy. This systematic review aims to summarize how aerobic exercise can help to alleviate unintended cardiotoxic side effects and identify gaps in need of further research. While published work supports the benefits of aerobic exercise, additional clinical investigations are warranted to determine the effects of different exercise modalities, timing, and duration to identify optimal aerobic training regimens for reducing cardiovascular complications, particularly late cardiac effects, in cancer survivors exposed to anthracyclines.


NMR in Biomedicine | 2017

Accelerated ferumoxytol-enhanced 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) cardiovascular MRI: validation in pediatric congenital heart disease: Accelerated 4D MUSIC

Ziwu Zhou; Fei Han; Stanislas Rapacchi; Kim-Lien Nguyen; Daniel Z. Brunengraber; Kim Gj; John Paul Finn; Peng Hu

The purpose of this work was to validate a parallel imaging (PI) and compressed sensing (CS) combined reconstruction method for a recently proposed 4D non‐breath‐held, multiphase, steady‐state imaging technique (MUSIC) cardiovascular MRI in a cohort of pediatric congenital heart disease patients. We implemented a graphics processing unit accelerated CS‐PI combined reconstruction method and applied it in 13 pediatric patients who underwent cardiovascular MRI after ferumoxytol administration. Conventional breath‐held contrast‐enhanced magnetic resonance angiography (CE‐MRA) was first performed during the first pass of ferumoxytol injection, followed by the original MUSIC and the proposed CS‐PI MUSIC during the steady‐state distribution phase of ferumoxytol. Qualities of acquired images were then evaluated using a four‐point scale. Left ventricular volumes and ejection fractions calculated from the original MUSIC and the CS‐PI MUSIC were also compared with conventional multi‐slice 2D cardiac cine MRI. The proposed CS‐PI MUSIC reduced the imaging time of the MUSIC acquisition to 4.6 ± 0.4 min from 8.9 ± 1.2 min. Computationally intensive image reconstruction was completed within 5 min without interruption of sequential clinical scans. The proposed method (mean 3.3–4.0) provided image quality comparable to that of the original MUSIC (3.2–4.0) (all P ≥ 0.42), and better than conventional breath‐held first‐pass CE‐MRA (1.1–3.3) for 13 anatomical structures (all P ≤ 0.0014) with good inter‐observer agreement (κ > 0.46). The calculated ventricular volumes and ejection fractions from both original MUSIC (r > 0.90) and CS‐PI MUSIC (r > 0.85) correlated well with 2D cine imaging. In conclusion, PI and CS were successfully incorporated into the 4D MUSIC acquisition to further reduce scan time by approximately 50% while maintaining highly comparable image quality in a clinically practical reconstruction time.


Current Oncology Reports | 2016

Cardiac MRI: a Translational Imaging Tool for Characterizing Anthracycline-Induced Myocardial Remodeling

Kim-Lien Nguyen; Peng Hu; Daniel B. Ennis; Jiaxin Shao; Kimberly A. Pham; Joseph J. Chen

Cardiovascular side effects of cancer therapeutics are the leading causes of morbidity and mortality in cancer survivors. Anthracyclines (AC) serve as the backbone of many anti-cancer treatment strategies, but dose-dependent myocardial injury limits their use. Cumulative AC exposure can disrupt the dynamic equilibrium of the myocardial microarchitecture while repeated injury and repair leads to myocyte loss, interstitial myocardial fibrosis, and impaired contractility. Although children are assumed to have greater myocardial plasticity, AC exposure at a younger age portends worse prognosis. In older patients, there is lower overall survival once they develop cardiovascular disease. Because aberrations in the myocardial architecture predispose the heart to a decline in function, early detection with sensitive imaging tools is crucial and the implications for resource utilization are substantial. As a comprehensive imaging modality, cardiac magnetic resonance (CMR) imaging is able to go beyond quantification of ejection fraction and myocardial deformation to characterize adaptive microstructural and microvascular changes that are important to myocardial tissue health. Herein, we describe CMR as an established translational imaging tool that can be used clinically to characterize AC-associated myocardial remodeling.

Collaboration


Dive into the Kim-Lien Nguyen's collaboration.

Top Co-Authors

Avatar

Peng Hu

University of California

View shared research outputs
Top Co-Authors

Avatar

J. Paul Finn

University of California

View shared research outputs
Top Co-Authors

Avatar

Gary Satou

University of California

View shared research outputs
Top Co-Authors

Avatar

Fei Han

University of California

View shared research outputs
Top Co-Authors

Avatar

Ihab Ayad

University of California

View shared research outputs
Top Co-Authors

Avatar

Jiaxin Shao

University of California

View shared research outputs
Top Co-Authors

Avatar

Ziwu Zhou

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John Paul Finn

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge