Journal of the American College of Cardiology | 1995
Kim Tan; Neil Sulke; Nick Taub; Edgar Sowton
OBJECTIVES This study evaluated the validity of the American College of Cardiology/American Heart Association ABC lesion classification scheme and its modifications. BACKGROUND With the continued refinement in angioplasty technique and equipment evolution, the lesion morphologic determinants of immediate angioplasty outcome have changed significantly. Hence, the validity of the classification scheme has been questioned. METHODS We assessed the lesion morphologic determinants of immediate angioplasty outcome in 729 consecutive patients who underwent coronary angioplasty of 994 vessels and 1,248 lesions. RESULTS Angioplasty success was achieved in 91% of lesions, and abrupt closure occurred in 3%. Success was achieved in 96%, 93% and 80% of type A, B and C lesions, respectively (A vs. B, p = NS; B vs. C, p < 0.001; A vs. C, p < 0.001; A vs. B1, p = NS; A vs. B2, p = 0.03; B1 vs. B2, p = 0.02; B2 vs. C, p < 0.001; C1 vs. C2, p = NS). Abrupt closure occurred in 2.1%, 2.6% and 5% of type A, B and C lesions, respectively (A vs. B, B vs. C, A vs. C and A vs. B1, all p = NS; B1 vs. B2, p = 0.01; B2 vs. C1, p = NS; C1 vs. C2, p = 0.04). Type B characteristics had a success rate ranging from 74% to 95% and an abrupt closure rate ranging from 2.2% to 14%. Type C characteristics had a success rate ranging from 57% to 88% and an abrupt closure rate ranging from 0% to 16%. Longer lesions, calcified lesions, diameter stenosis of 80% to 99% and presence of thrombus were predictive of a lower success rate. Longer lesions, angulated lesions, diameter stenosis of 80% to 99% and calcified lesions were predictive of an abrupt closure. CONCLUSIONS The previously proposed classification schemes are outdated and need to be changed for application in current angioplasty practice. Analyzing specific lesion morphologic characteristics rather than applying a simple lesion classification score when evaluating angioplasty outcome may be more useful because it provides a more precise profile of the lesion and allows better patient stratification and selection.
Journal of the American College of Cardiology | 1997
Kayvan Kamalvand; Kim Tan; Athanasios Kotsakis; Cliff Bucknall; Neil Sulke
OBJECTIVES We sought 1) to compare three pacing modalities-DDDR with mode switching (DM), DDDR with conventional upper rate behavior (DR) and VVIR (VR)-in patients with a history of atrial tachyarrhythmias, and 2) to assess the efficacy of six mode-switching algorithms. BACKGROUND A history of atrial tachyarrhythmias has been a relative contraindication to dual-chamber pacing. Several mode-switching algorithms have recently been developed to prevent rapid tracking of atrial tachyarrhythmias. METHODS Forty-eight patients (mean age 64 years, 58% male) with a history of atrial tachyarrhythmias and heart block had a DM pacemaker implanted. Pacemakers were programmed to DM, DR and VR modes for 4 weeks each in a randomized crossover design. All subjects used a patient-activated electrocardiographic (ECG) recorder throughout the study and additionally underwent ambulatory ECG monitoring and a treadmill exercise test in each mode. They completed three symptom questionnaires at the end of each pacing period. At the end of the study, patients chose their preferred pacing period. RESULTS DM was significantly better than VR mode objectively (exercise time DM 8.1 min, VR 7.0 min, p < 0.01) and subjectively (perceived well-being DM 69, VR 51, p < 0.001; functional class DM 2.2, VR 2.5, p < 0.05; subjective symptom score DM 21.2, VR 26.8, p = 0.01). Patient-perceived well-being was significantly better with DM than with DR mode (DM 69, DR 60, p = 0.02). DM mode was the preferred pacing period (DM 51%, DR 14%, VR 14%). Early termination of pacing because of adverse symptoms was requested by 33% of patients during VR, 19% during DR but only 3% during DM mode. A higher proportion of patients with a fast mode-switching device preferred DM mode (fast 55%, slow 49%), whereas no patients with a fast mode-switching device chose VR as the preferred mode (fast 0%, slow 19%). In the subgroup of patients who had had atrioventricular node ablation, DM was also preferred to VR mode (DM 53%, VR 27%). Overall, there were only two cases of inappropriate mode switching and one case of inappropriate tracking of an atrial tachyarrhythmia. CONCLUSIONS DM is the pacing mode of choice of patients with paroxysmal atrial tachyarrhythmias. With optimal programming, inappropriate mode switching and tracking of atrial tachyarrhythmias was very uncommon.
Pacing and Clinical Electrophysiology | 1998
Peter J. Stafford; Kavan Kamalvand; Kim Tan; Richard Vincent; Neil Sulke
After cardioversion from atrial fibrillation (AF) many patients develop early recurrence of the arrhythmia. While these patients may be appropriate for immediate prophylaxis against AF recurrence their identification at the time of cardioversion is not possible. Since the signal‐averaged P wave (SAPW) is abnormal in individuals with atrial arrhythmia, we assessed its utility for predicting early AF recurrence after cardioversion. Seventy‐five cardioversions in 31 patients were evaluated. The mean age was 59 (range 28–79) years; 26 were male. Fifty‐eight cardioversions were internal using low energy biphasic DC shocks delivered via electrodes placed in the right atrial appendage and coronary sinus. P wave specific signal averaging was performed at 3 and 24 hours after each cardioversion to estimate filtered P wave duration and energy from 20, 40, and 60 to 150 Hz. Follow‐up was by regular clinic visits and transtelephonic ECG monitoring. Early recurrence of AF (prospectively defined as sinus rhythm duration < 1 week) occurred after 30 cardioversions. No differences were found in any P wave variable measured at 3 hours between these cardioversions and those that resulted in a longer duration of sinus rhythm. Paired 3‐ and 24‐hour signal‐averaged data were available in 47 cardioversions. There were significant falls in P wave energy from 3 to 24 hours after 31 cardioversions that resulted in sinus rhythm for > 1 week, (P40: 3 hours 11.2 [±1.5] μV2· s, 24 hours 8.6 [±1.2] μV2· s, P < 0.001), but not following the 16 after which AF returned within 1 week (P40: 3 hours 9.0 [±1.2] μV2· s, 24 hours 8.5 [±1.2] μV2· s, P = NS). A fall in P40 of > 25% had a positive predictive accuracy for maintenance of sinus rhythm of 87%; negative predictive accuracy was only 37%. Similar falls in P wave energy occurred after cardioversions that resulted in longer term (> 4 weeks) sinus rhythm, but not in those that did not. However, the predictive accuracy of a fall in P40 was less (positive predictive accuracy 38%, negative predictive accuracy 62%). Patients with relapsing permanent AF who remain in sinus rhythm for at least 1 week after cardioversion show a fall in P wave energy within the first 24 hours. However, in these patients the technique does not predict recurrent AF within 1 week nor sinus rhythm > 4 weeks. These observations suggest persistent disordered atrial activation as a mechanism for early recurrence of AF after cardioversion.
Pacing and Clinical Electrophysiology | 1996
Neil Sulke; Kim Tan; Kayvan Kamalvand; Julian Bostock; Cliff Bucknall
Dual sensor ventricular demand rate responsive (VVIR mode) pacing was compared with single sensor rate responsive pacing to assess whether this new development should be more widely incorporated in modern pacemaker devices. A within patient randomized, double‐blind crossover study involving ten patients, mean age 67.4 years (70% male), had Medtronic Legend Plus dual sensor VVIR pacemakers implanted for high grade A V block and chronic or persistent paroxysmal atrial fibrillation. Performance values were compared to 20 healthy control subjects of a similar age and gender. Patients were both subjectively and objectively assessed after 2 weeks of out‐of‐hospital activity in VVIR mode (minute ventilation sensing), VVIR mode (activity sensing), VVIR mode (dual sensor), and VVI mode (no rate response). All patients were assessed for subjective preference for, and objective improvement in, any pacing modality as assessed by standardized daily activity protocols and graded exercise treadmill testing. Subjective perception of exercise capacity and functional status was significantly lower in VVI mode (P < 0.05) compared to any of the VVIR modes, which did not differ. After completion of the study 70% of patients chose VVIR as their preferred mode, with 30% expressing no preference. Forty percent preferred activity sensor WIR mode pacing, 30% preferred dual sensor VVIR mode pacing, and 70% found either dual sensor WIR mode, minute ventilation sensor WIR mode, or both modalities least acceptable. No patient found activity sensing WIR mode least acceptable. Graded treadmill testing revealed significantly lower exercise tolerance during WI mode pacing (P < 0.01) compared to the VVIR modalities, which did not differ. Overall, chronotropic response was best with dual sensor pacing during standardized daily activity protocols and during the standard car journey. The data from this study suggest that there is no marked clinical advantage obtained from the use of dual sensor devices over current activity sensing ventricular demand rate responsive pacemakers, but with the probable added disadvantages of increased size, complexity, cost, and decreased longevity.
Pacing and Clinical Electrophysiology | 1996
Kayvan Kamalvand; Kim Tan; Roger Willems; Neil Sulke
Pacemakers are becoming increasingly sophisticated, offering a host of new diagnostic functions. This case illustrates how some of these functions can be used to help with the diagnosis and management of patients with pacemakers who suffer from cardiac arrhythmias.
Pacing and Clinical Electrophysiology | 1996
Neil Sulke; Kim Tan; Julian Bostock
Following His‐bundle ablation and VVIR pacemaker implantation, severe pacemaker syndrome developed and was treated with DDDR pacing, in a 70‐year‐old woman. Due to bilateral subclavian vein stenoses, DDDR pacing could not be maintained and an unusual method of restoring atrioventricular synchrony is described using the contraiateral redundant atrial electrode connected to the ipsilateral dual chamber pacemaker and ventricular electrode.
European Heart Journal | 1999
Kayvan Kamalvand; Kim Tan; G. Lloyd; J. Gill; Cliff Bucknall; Neil Sulke
Catheterization and Cardiovascular Diagnosis | 1994
Kim Tan; Robert A. Henderson; Neil Sulke; Richard Cooke; Sheila Karani; Edgar Sowton
European Heart Journal | 1995
Kim Tan; Neil Sulke; N. Taub; Edgar Sowton
European Heart Journal | 1995
Kim Tan; N. Sule; N. Taub; Edgar Sowton