Klaus Giewekemeyer
University of Göttingen
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Klaus Giewekemeyer.
Proceedings of the National Academy of Sciences of the United States of America | 2010
Klaus Giewekemeyer; Pierre Thibault; Sebastian Kalbfleisch; André Beerlink; Cameron M. Kewish; Martin Dierolf; Franz Pfeiffer; Tim Salditt
Recent advances in coherent x-ray diffractive imaging have paved the way to reliable and quantitative imaging of noncompact specimens at the nanometer scale. Introduced a year ago, an advanced implementation of ptychographic coherent diffractive imaging has removed much of the previous limitations regarding sample preparation and illumination conditions. Here, we apply this recent approach toward structure determination at the nanoscale to biological microscopy. We show that the projected electron density of unstained and unsliced freeze-dried cells of the bacterium Deinococcus radiodurans can be derived from the reconstructed phase in a straightforward and reproducible way, with quantified and small errors. Thus, the approach may contribute in the future to the understanding of the highly disputed nucleoid structure of bacterial cells. In the present study, the estimated resolution for the cells was 85 nm (half-period length), whereas 50-nm resolution was demonstrated for lithographic test structures. With respect to the diameter of the pinhole used to illuminate the samples, a superresolution of about 15 was achieved for the cells and 30 for the test structures, respectively. These values should be assessed in view of the low dose applied on the order of ≃1.3·105 Gy, and were shown to scale with photon fluence.
Optics Express | 2012
Robin N. Wilke; Marius Priebe; Matthias Bartels; Klaus Giewekemeyer; A. Diaz; P. Karvinen; Tim Salditt
Ptychographic coherent X-ray diffractive imaging (PCDI) has been combined with nano-focus X-ray diffraction to study the structure and density distribution of unstained and unsliced bacterial cells, using a hard X-ray beam of 6.2keV photon energy, focused to about 90nm by a Fresnel zone plate lens. While PCDI provides images of the bacteria with quantitative contrast in real space with a resolution well below the beam size at the sample, spatially resolved small angle X-ray scattering using the same Fresnel zone plate (cellular nano-diffraction) provides structural information at highest resolution in reciprocal space up to 2nm(-1). We show how the real and reciprocal space approach can be used synergistically on the same sample and with the same setup. In addition, we present 3D hard X-ray imaging of unstained bacterial cells by a combination of ptychography and tomography.
Journal of Synchrotron Radiation | 2012
S. P. Krüger; H. Neubauer; Matthias Bartels; Sebastian Kalbfleisch; Klaus Giewekemeyer; P.-J. Wilbrandt; Michael Sprung; Tim Salditt
Optimized X-ray waveguides have been fabricated and characterized in terms of transmission, angular acceptance, farfield pattern and imaging applications. Beam confinement down to sub-10 nm in two orthogonal directions has been demonstrated, at the nano-focus endstation at P10 of PETRA III at HASYLAB/DESY.
Optics Express | 2011
Klaus Giewekemeyer; Mike Beckers; Thomas Gorniak; Michael Grunze; Tim Salditt; Axel Rosenhahn
Coherent x-ray diffractive microscopy enables full reconstruction of the complex transmission function of an isolated object to diffraction-limited resolution without relying on any optical elements between the sample and detector. In combination with ptychography, also specimens of unlimited lateral extension can be imaged. Here we report on an application of ptychographic coherent diffractive imaging (PCDI) in the soft x-ray regime, more precisely in the so-called water window of photon energies where the high scattering contrast between carbon and oxygen is well-suited to image biological samples. In particular, we have reconstructed the complex sample transmission function of a fossil diatom at a photon energy of 517 eV. In imaging a lithographically fabricated test sample a resolution on the order of 50 nm (half-period length) has been achieved. Along with this proof-of-principle for PCDI at soft x-ray wavelengths, we discuss the experimental and technical challenges which can occur especially for soft x-ray PCDI.
Ultramicroscopy | 2013
Mike Beckers; Tobias Senkbeil; Thomas Gorniak; Klaus Giewekemeyer; Tim Salditt; Axel Rosenhahn
X-ray ptychography is a rapidly developing phase retrieval technique that combines the experimental advantages of coherent diffractive imaging with the possibility to image extended specimens. Data collection requires imaging at several scan points with high positional accuracy, which implies susceptibility to mechanical drift. This is a well-known problem in ptychographic scans, which can reduce reconstruction quality and limit the achievable resolution. Using a simple model for positional drift, we show that a set of corrected positions can be found systematically, leading to strong improvements in the reconstruction of a Siemens star dataset severely affected by drift.
Optical Nanoscopy | 2012
Matthias Bartels; Marius Priebe; Robin N. Wilke; Sven P Krüger; Klaus Giewekemeyer; Sebastian Kalbfleisch; Christian Olendrowitz; Michael Sprung; Tim Salditt
We have imaged the three-dimensional density distribution of unstained and unsliced, freeze-dried cells of the gram-positive bacterium Deinococcus radiodurans by tomographic x-ray propagation microscopy, i.e. projection tomography with phase contrast formation by free space propagation. The work extends previous x-ray imaging of biological cells in the simple in-line holography geometry to full three-dimensional reconstruction, based on a fast iterative phase reconstruction algorithm which circumvents the usual twin-image problem. The sample is illuminated by the highly curved wave fronts emitted from a virtual quasi-point source with 10 nm cross section, realized by two crossed x-ray waveguides. The experimental scheme allows for a particularly dose efficient determination of the 3D density distribution in the cellular structure.
New Journal of Physics | 2010
Klaus Giewekemeyer; H. Neubauer; Sebastian Kalbfleisch; S. P. Krüger; Tim Salditt
We report on lensless nanoscale imaging using x-ray waveguides as ultra-small sources for quasi-point-like illumination. We first give a brief account of the basic optical setup, an overview of the progress in waveguide fabrication and characterization, as well as the basics of image formation. We then compare one-step holographic and iterative ptychographic reconstruction, both for simulated and experimental data collected on samples illuminated by waveguided beams. We demonstrate that scanning the sample with partial overlap can substantially improve reconstruction quality in holographic imaging, and that divergent beams make efficient use of the limited dynamic range of current detectors, regardless of the reconstruction scheme. Among different experimental settings presented, smallest source dimensions of 29 nm (horizontal) ×17 nm have been achieved, using multi-modal interference effects. These values have been determined by ptychographic reconstruction of a Ta test structure at 17.5 keV and have been corroborated by simulations of field propagation inside the waveguide.
Optics Express | 2011
Tim Salditt; Sebastian Kalbfleisch; Markus Osterhoff; S. P. Krüger; Matthias Bartels; Klaus Giewekemeyer; H. Neubauer; M. Sprung
We have studied the spatial coherence properties of a nano-focused x-ray beam by grating (Talbot) interferometry in projection geometry. The beam is focused by a fixed curvature mirror system optimized for high flux density under conditions of partial coherence. The spatial coherence of the divergent exit wave emitted from the mirror focus is measured by Talbot interferometry The results are compared to numerical calculations of coherence propagation. In view of imaging applications, the magnified in-line image of a test pattern formed under conditions of partial coherence is analyzed quantitatively. Finally, additional coherence filtering by use of x-ray waveguides is demonstrated. By insertion of x-ray waveguides, the beam diameter can be reduced from typical values of 200 nm to values below 15 nm. In proportion to the reduction in the focal spot size, the numerical aperture (NA) of the projection imaging system is increased, as well as the coherence length, as quantified by grating interferometry.
Optics Express | 2010
S. P. Krüger; Klaus Giewekemeyer; Sebastian Kalbfleisch; Matthias Bartels; H. Neubauer; Tim Salditt
We have combined two high transmission planar x-ray waveguides glued onto each other in a crossed geometry to form an effective quasi-point source. From measurements of the far-field diffraction pattern, the phase and amplitude of the near-field distribution is retrieved using the error-reduction algorithm. In agreement with finite difference field simulations (forward calculation), the reconstructed exit wave intensity distribution (inverse calculation) exhibits a full width at half maximum (FWHM) below 15 nm in both dimensions. Finally, holographic imaging is successfully demonstrated for the crossed waveguide device by translation of a lithographic test structure through the waveguide beam.
Journal of Synchrotron Radiation | 2013
Klaus Giewekemeyer; Robin N. Wilke; Markus Osterhoff; Matthias Bartels; Sebastian Kalbfleisch; Tim Salditt
In the past decade Kirkpatrick-Baez (KB) mirrors have been established as powerful focusing systems in hard X-ray microscopy applications. Here a ptychographic characterization of the KB focus in the dedicated nano-imaging setup GINIX (Göttingen Instrument for Nano-Imaging with X-rays) at the P10 coherence beamline of the PETRA III synchrotron at HASLYLAB/DESY, Germany, is reported. More specifically, it is shown how aberrations in the KB beam, caused by imperfections in the height profile of the focusing mirrors, can be eliminated using a pinhole as a spatial filter near the focal plane. A combination of different pinhole sizes and illumination conditions of the KB setup makes the prepared optical setup well suited not only for high-resolution ptychographic coherent X-ray diffractive imaging but also for moderate-resolution/large-field-of-view propagation imaging in the divergent KB beam.