Kristina Giske
German Cancer Research Center
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Kristina Giske.
Journal of Applied Clinical Medical Physics | 2014
Christoph Hoffmann; Sonja Krause; Eva Maria Stoiber; Angela Mohr; Stefan Rieken; Oliver Schramm; Jürgen Debus; Florian Sterzing; Rolf Bendl; Kristina Giske
The purpose of this study was to test the accuracy of a commercially available deformable image registration tool in a clinical situation. In addition, to demonstrate a method to evaluate the resulting transformation of such a tool to a reference defined by multiple experts. For 16 patients (seven head and neck, four thoracic, five abdominal), 30‐50 anatomical landmarks were defined on recognizable spots of a planning CT and a corresponding fraction CT. A commercially available deformable image registration tool, Velocity AI, was used to align all fraction CTs with the respective planning CTs. The registration accuracy was quantified by means of the target registration error in respect to expert‐defined landmarks, considering the interobserver variation of five observers. The interobserver uncertainty of the landmark definition in our data sets is found to be 1.2±1.1mm. In general the deformable image registration tool decreases the extent of observable misalignments from 4‐8 mm to 1‐4 mm for nearly 50% of the landmarks (to 77% in sum). Only small differences are observed in the alignment quality of scans with different tumor location. Smallest residual deviations were achieved in scans of the head and neck region (79%,≤4mm) and the thoracic cases (79%,≤4mm), followed by the abdominal cases (59%,≤4mm). No difference is observed in the alignment quality of different tissue types (bony vs. soft tissue). The investigated commercially available deformable image registration tool is capable of reducing a mean target registration error to a level that is clinically acceptable for the evaluation of retreatment plans and replanning in case of gross tumor change during treatment. Yet, since the alignment quality needs to be improved further, the individual result of the deformable image registration tool has still to be judged by the physician prior to application. PACS numbers: 87.57.nj, 87.57.N‐, 87.55.‐x
International Journal of Radiation Oncology Biology Physics | 2011
Kristina Giske; Eva Maria Stoiber; Michael Schwarz; Armin Stoll; Marc W. Muenter; Carmen Timke; Falk Roeder; Juergen Debus; Peter E. Huber; Christian Thieke; Rolf Bendl
PURPOSE To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. METHODS AND MATERIALS A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. RESULTS The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. CONCLUSIONS Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future.
International Journal of Radiation Oncology Biology Physics | 2009
Eva Maria Stoiber; Gerhard Lechsel; Kristina Giske; Marc W. Muenter; Angelika Hoess; Rolf Bendl; Juergen Debus; Peter E. Huber; Christian Thieke
PURPOSE To evaluate stereotactic positioning uncertainties of patients with paraspinal tumors treated with fractionated intensity-modulated radiotherapy; and to determine whether target-point correction via rigid registration is sufficient for daily patient positioning. PATIENTS AND METHODS Forty-five patients with tumors at the cervical, thoracic, and lumbar spine received regular control computed-tomography (CT) scans using an in-room CT scanner. All patients were immobilized with the combination of Scotch cast torso and head masks. The positioning was evaluated regarding translational and rotational errors by applying a rigid registration algorithm based on mutual information. The registration box was fitted to the target volume for optimal registration in the high-dose area. To evaluate the suitability of the rigid registration result for correcting the target volume position we subsequently registered three small subsections of the upper, middle, and lower target volume. The resulting residual deviations reflect the extent of the elastic deformations, which cannot be covered by the rigid-body registration procedure. RESULTS A total of 321 control CT scans were evaluated. The rotational errors were negligible. Translational errors were smallest for cervical tumors (-0.1 +/- 1.1, 0.3 +/- 0.8, and 0.1 +/- 0.9 mm along left-right, anterior-posterior, and superior-inferior axes), followed by thoracic (0.8 +/- 1.1, 0.3 +/- 0.8, and 1.1 +/- 1.3 mm) and lumbar tumors (-0.7 +/- 1.3, 0.0 +/- 0.9, and 0.5 +/- 1.6 mm). The residual deviations of the three subsections were <1 mm. CONCLUSIONS The applied stereotactic patient setup resulted in small rotational errors. However, considerable translational positioning errors may occur; thus, on the basis of these data daily control CT scans are recommended. Rigid transformation is adequate for correcting the target volume position.
Radiation Oncology | 2014
Markus Stoll; Kristina Giske; Jürgen Debus; Rolf Bendl; Eva Maria Stoiber
BackgroundTo analyse the frequency of re-planning and its variability dependent on the IGRT correction strategy and on the modification of the dosimetric criteria for re-planning for the spinal cord in head and neck IG-IMRT.MethodsDaily kV-control-CTs of six head and neck patients (=175 CTs) were analysed. All volumes of interest were re-contoured using deformable image registration. Three IGRT correction strategies were simulated and the resulting dose distributions were computed for all fractions. Different sets of criteria with varying dose thresholds for re-planning were investigated. All sets of criteria ensure equivalent target coverage of both CTVs, but vary in the tolerance threshold of the spinal cord.ResultsThe variations of the D95 and D2 in respect to the planned values ranged from -7% to +3% for both CTVs, and -2% to +6% for the spinal cord. Despite different correction vectors of the three IGRT strategies, the dosimetric differences were small. The number of fractions not requiring re-planning varied between 0% and 11% dependent on the applied IGRT correction strategy. In contrast, this number ranged between 32% and 70% dependent on the dosimetric thresholds, even though these thresholds were only gently modified.ConclusionsThe more precise the planned dose needs to be maintained over the treatment course, the more frequently re-planning is required. The influence of different IGRT correction strategies, even though geometrically notable, was found to be of only limited relevance for the re-planning frequency. In contrast, the definition and modification of thresholds for re-planning have a major impact on the re-planning frequency.
Acta Oncologica | 2014
Eva Maria Stoiber; Michael Schwarz; Jürgen Debus; Rolf Bendl; Kristina Giske
Abstract Background. To present a new method that determines an optimised IGRT couch correction vector from a displacement vector field (DVF). The DVF is computed by a deformable image registration (DIR) method. The proposed method can improve the quality of volume-of-interest (VOI) alignment in image guided radiation therapy (IGRT), and can serve as a decision-making aid for re-planning. Material and methods. The proposed method was demonstrated using the CT data sets of 11 head-and-neck cancer patients with daily kilovoltage control-CTs. A DVF was computed for each control-CT using a DIR method. The DVF was used for voxel tracking and re-contouring of the VOIs in the control-CTs. Then a rigid body transformation, which could be used as couch correction vector, was optimised. The aim of the optimisation process was to find a vector and rotations that map the deformed VOIs into a specified territory. This territory was defined by a margin extension of the VOIs at the time of the planning process. Within this extension, VOI motion and deformation was tolerated. The objective function in the optimisation process was the sum of all volume fractions outside the defined territories. Results. The proposed method was able to find a correction vector, which resulted in a coverage of the target volumes of at least 98% in 52.3% of all fractions. In contrast, a standard IGRT correction using a rigid registration method only fulfilled this criterion in 22.6% of all fractions. The optimisation process took an average of 1.5 minutes per fraction. Conclusion. The knowledge of the deformation of the anatomy allows the determination of an optimised rigid correction vector using our method. The method ensures controlled mapping of the VOIs despite small deformations. If no optimised vector can be determined, re-planning should be considered. Thus, our method can also serve as a decision-making aid for re-planning.
Acta Oncologica | 2013
Eva Maria Stoiber; Michael Schwarz; Peter E. Huber; Jürgen Debus; Rolf Bendl; Kristina Giske
Lind PAM, Marks LB, Hardenbergh PH, Clough R, Fan [21] M, Hollis D, et al. Technical factors associated with radiation pneumonitis after local regional radiation therapy for breast cancer. Int J Radiat Oncol Biol Phys 2002;52: 137–43. Allen AM, Czerminska M, Janne PA, Sugarbaker DJ, Bueno [22] R, Harris JR, et al. Fatal pneumonitis associated with intensity-modulated radiation therapy for mesothelioma. Int J Radiat Oncol Biol Phys 2006;65:640–5. Minor GI, Yashar CM, Spanos WJ, Jr., Jose BO, Silverman [23] CL, Carrascosa LA, et al. The relationship of radiation pneumonitis to treated lung volume in breast conservation therapy. Breast J 2006;12:48–52. Taylor CW, Nisbet A, McGale P, Darby SC. Cardiac expo[24] sures in breast cancer radiotherapy: 1950s–1990s. Int J Radiat Oncol Biol Phys 2007;69:1484–95. Borger JH, Hooning MJ, Boersma LJ, Snijders-Keilholz A, [25] Aleman BM, Lintzen E, et al. Cardiotoxic effects of tangential breast irradiation in early breast cancer patients: The role of irradiated heart volume. Int J Radiat Oncol Biol Phys 2007;69:1131–8. Taylor CW, Nisbet A, McGale P, Goldman U, Darby SC, Hall [15] P, et al. Cardiac doses from Swedish breast cancer radiotherapy since the 1950s. Radiother Oncol 2009;90:127–35. Darby SC, Cutter DJ, Boerma M, Constine LS, Fajardo LF, [16] Kodama K, et al. Radiation-related heart disease: Current knowledge and future prospects. Int J Radiat Oncol Biol Phys 2010;76:656–65. Gagliardi G, Constine LS, Moiseenko V, Correa C, Pierce [17] LJ, Allen AM, et al. Radiation dose-volume effects in the heart. Int J Radiat Oncol Biol Phys 2010;76:S77–85. Correa CR, Das IJ, Litt HI, Ferrari V, Hwang WT, Solin LJ, [18] et al. Association between tangential beam treatment parameters and cardiac abnormalities after definitive radiation treatment for left-sided breast cancer. Int J Radiat Oncol Biol Phys 2008;72:508–16. Teh AYM, Park EJH, Shen L, Cheung HT. Three-demnsional [19] volumentric analysis of irradiated lung with adjuvant breast irradiation. Int J Radiat Oncol Biol Phys 2009;75:1309–15. Das IJ, Cheng C-W, Fein DA, Fowble B. Patterns of dose [20] variability in radiation prescription of breast cancer. Radiother Oncol 1997;44:83–9.
Radiation Oncology | 2012
Michael Schwarz; Kristina Giske; Armin Stoll; Simeon Nill; P. Huber; Jürgen Debus; Rolf Bendl; Eva Maria Stoiber
BackgroundTo evaluate the impact of image-guided radiation therapy (IGRT) versus non-image-guided radiation therapy (non-IGRT) on the dose to the clinical target volume (CTV) and the cervical spinal cord during fractionated intensity-modulated radiation therapy (IMRT) for head-and-neck cancer (HNC) patients.Material and MethodsFor detailed investigation, 4 exemplary patients with daily control-CT scans (total 118 CT scans) were analyzed. For the IGRT approach a target point correction (TPC) derived from a rigid registration focused to the high-dose region was used. In the non-IGRT setting, instead of a TPC, an additional cohort-based safety margin was applied. The dose distributions of the CTV and spinal cord were calculated on each control-CT and the resulting dose volume histograms (DVHs) were compared with the planned ones fraction by fraction. The D50 and D98 values for the CTV and the D5 values of the spinal cord were additionally reported.ResultsIn general, the D50 and D98 histograms show no remarkable difference between both strategies. Yet, our detailed analysis also reveals differences in individual dose coverage worth inspection. Using IGRT, the D5 histograms show that the spinal cord less frequently receives a higher dose than planned compared to the non-IGRT setting. This effect is even more pronounced when looking at the curve progressions of the respective DVHs.ConclusionsBoth approaches are equally effective in maintaining CTV coverage. However, IGRT is beneficial in spinal cord sparing. The use of an additional margin in the non-IGRT approach frequently results in a higher dose to the spinal cord than originally planned. This implies that a margin reduction combined with an IGRT correction helps to maintain spinal cord dose sparing best as possible. Yet, a detailed analysis of the dosimetric consequences dependent on the used strategy is required, to detect single fractions with unacceptable dosimetric deviations.
International Journal of Radiation Oncology Biology Physics | 2011
Eva Maria Stoiber; Kristina Giske; Kai Schubert; Florian Sterzing; Gregor Habl; Matthias Uhl; Klaus Herfarth; Rolf Bendl; Jürgen Debus
PURPOSE To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. METHODS AND MATERIALS 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patients skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. RESULTS After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. CONCLUSION The patient fixation used allows for deformations between the patients skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.
Radiotherapy and Oncology | 2013
Eva Maria Stoiber; Michael Schwarz; Jürgen Debus; P. Huber; Rolf Bendl; Kristina Giske
PURPOSE To present a new method that assesses the delivered maximum dose of different spinal cord sections in head-and-neck cancer treated with intensity-modulated radiation therapy (IMRT). This allows a more accurate estimation of the remaining cord dose tolerance in case of a later re-irradiation treatment planning. MATERIALS AND METHODS The suggested workflow is demonstrated using daily acquired kilo-voltage control-CTs of four head-and-neck cancer patients (118 control-CTs). The local maximum dose inside different cord levels is determined and accumulated for the planning situation and over the treatment course for an IGRT and a non-IGRT approach. RESULTS The approach is suitable to accurately detect and document the delivered maximum dose dependent on the cord levels. The delivered maximum dose differed up to 13% from the planned one in all sections due to setup uncertainties and the applied correction strategy. CONCLUSION The presented approach facilitates later re-irradiation treatment planning due to detailed documentation of the delivered maximum dose to the spinal cord levels in the primary IMRT. The method also facilitates the interpretation of complex 3D dose information by reducing it to its essentials. This 2D illustration is an aid to orientation for the physician in the re-irradiation planning process.
Medical Physics | 2013
Andrea Fränzle; Maren Bretschi; Tobias Bäuerle; Kristina Giske; Jens Hillengass; Rolf Bendl
PURPOSE Most of the patients who died of breast cancer have developed bone metastases. To understand the pathogenesis of bone metastases and to analyze treatment response of different bone remodeling therapies, preclinical animal models are examined. In breast cancer, bone metastases are often bone destructive. To assess treatment response of bone remodeling therapies, the volumes of these lesions have to be determined during the therapy process. The manual delineation of missing structures, especially if large parts are missing, is very time-consuming and not reproducible. Reproducibility is highly important to have comparable results during the therapy process. Therefore, a computerized approach is needed. Also for the preclinical research, a reproducible measurement of the lesions is essential. Here, the authors present an automated segmentation method for the measurement of missing bone mass in a preclinical rat model with bone metastases in the hind leg bones based on 3D CT scans. METHODS The affected bone structure is compared to a healthy model. Since in this preclinical rat trial the metastasis only occurs on the right hind legs, which is assured by using vessel clips, the authors use the left body side as a healthy model. The left femur is segmented with a statistical shape model which is initialised using the automatically segmented medullary cavity. The left tibia and fibula are segmented using volume growing starting at the tibia medullary cavity and stopping at the femur boundary. Masked images of both segmentations are mirrored along the median plane and transferred manually to the position of the affected bone by rigid registration. Affected bone and healthy model are compared based on their gray values. If the gray value of a voxel indicates bone mass in the healthy model and no bone in the affected bone, this voxel is considered to be osteolytic. RESULTS The lesion segmentations complete the missing bone structures in a reasonable way. The mean ratio vr∕vm of the reconstructed bone volume vr and the healthy model bone volume vm is 1.07, which indicates a good reconstruction of the modified bone. CONCLUSIONS The qualitative and quantitative comparison of manual and semi-automated segmentation results have shown that comparing a modified bone structure with a healthy model can be used to identify and measure missing bone mass in a reproducible way.