Radiation Oncology | 2006
Christoph Thilmann; Simeon Nill; Thomas Tücking; Angelika Höss; Bernd Hesse; Lars Dietrich; Rolf Bendl; Bernhard Rhein; Peter Häring; Christian Thieke; Uwe Oelfke; Juergen Debus; Peter E. Huber
BackgroundThe purpose of the study was the clinical implementation of a kV cone beam CT (CBCT) for setup correction in radiotherapy.Patients and methodsFor evaluation of the setup correction workflow, six tumor patients (lung cancer, sacral chordoma, head-and-neck and paraspinal tumor, and two prostate cancer patients) were selected. All patients were treated with fractionated stereotactic radiotherapy, five of them with intensity modulated radiotherapy (IMRT). For patient fixation, a scotch cast body frame or a vacuum pillow, each in combination with a scotch cast head mask, were used. The imaging equipment, consisting of an x-ray tube and a flat panel imager (FPI), was attached to a Siemens linear accelerator according to the in-line approach, i.e. with the imaging beam mounted opposite to the treatment beam sharing the same isocenter. For dose delivery, the treatment beam has to traverse the FPI which is mounted in the accessory tray below the multi-leaf collimator. For each patient, a predefined number of imaging projections over a range of at least 200 degrees were acquired. The fast reconstruction of the 3D-CBCT dataset was done with an implementation of the Feldkamp-David-Kress (FDK) algorithm. For the registration of the treatment planning CT with the acquired CBCT, an automatic mutual information matcher and manual matching was used.Results and discussionBony landmarks were easily detected and the table shifts for correction of setup deviations could be automatically calculated in all cases. The image quality was sufficient for a visual comparison of the desired target point with the isocenter visible on the CBCT. Soft tissue contrast was problematic for the prostate of an obese patient, but good in the lung tumor case. The detected maximum setup deviation was 3 mm for patients fixated with the body frame, and 6 mm for patients positioned in the vacuum pillow. Using an action level of 2 mm translational error, a target point correction was carried out in 4 cases. The additional workload of the described workflow compared to a normal treatment fraction led to an extra time of about 10–12 minutes, which can be further reduced by streamlining the different steps.ConclusionThe cone beam CT attached to a LINAC allows the acquisition of a CT scan of the patient in treatment position directly before treatment. Its image quality is sufficient for determining target point correction vectors. With the presented workflow, a target point correction within a clinically reasonable time frame is possible. This increases the treatment precision, and potentially the complex patient fixation techniques will become dispensable.
Physics in Medicine and Biology | 2006
U. Malsch; Christian Thieke; Peter E. Huber; Rolf Bendl
Image registration has many medical applications in diagnosis, therapy planning and therapy. Especially for time-adaptive radiotherapy, an efficient and accurate elastic registration of images acquired for treatment planning, and at the time of the actual treatment, is highly desirable. Therefore, we developed a fully automatic and fast block matching algorithm which identifies a set of anatomical landmarks in a 3D CT dataset and relocates them in another CT dataset by maximization of local correlation coefficients in the frequency domain. To transform the complete dataset, a smooth interpolation between the landmarks is calculated by modified thin-plate splines with local impact. The concept of the algorithm allows separate processing of image discontinuities like temporally changing air cavities in the intestinal track or rectum. The result is a fully transformed 3D planning dataset (planning CT as well as delineations of tumour and organs at risk) to a verification CT, allowing evaluation and, if necessary, changes of the treatment plan based on the current patient anatomy without time-consuming manual re-contouring. Typically the total calculation time is less than 5 min, which allows the use of the registration tool between acquiring the verification images and delivering the dose fraction for online corrections. We present verifications of the algorithm for five different patient datasets with different tumour locations (prostate, paraspinal and head-and-neck) by comparing the results with manually selected landmarks, visual assessment and consistency testing. It turns out that the mean error of the registration is better than the voxel resolution (2 x 2 x 3 mm(3)). In conclusion, we present an algorithm for fully automatic elastic image registration that is precise and fast enough for online corrections in an adaptive fractionated radiation treatment course.
Physics in Medicine and Biology | 2006
Christian P. Karger; Angelika Höss; Rolf Bendl; Valer Canda; Lothar R. Schad
For the application of magnetic resonance imaging (MRI) in precision radiotherapy, image distortions must be reduced to a minimum to maintain geometrical accuracy. Recently, two-dimensional (2D) and three-dimensional (3D) algorithms for MRI-device-specific distortion corrections were developed by the manufacturers of MRI devices. A previously developed phantom (Karger C P et al 2003 Phys. Med. Biol. 48 211-21) was used to quantify and assess the size of geometrical image distortions before and after application of the 2D and 3D correction algorithm in the head region. Four different types of MRI devices with different gradient systems were measured. For comparison, measurements were also performed with two computed tomography (CT) devices. Mean distortions of up to 4.6+/-1.4 mm (maximum: 5.8 mm) were found prior to the correction. After the correction, the mean distortions were well below 2.0 mm in most cases. Distortions in the CT images were below or equal to 1.0 mm on average. Generally, the 3D algorithm produced comparable or better results than the 2D algorithm. The remaining distortions after the correction appear to be acceptable for fractionated radiotherapy.
Physics in Medicine and Biology | 2002
Barbara Dobler; Rolf Bendl
A new method is described that allows precise modelling of organs at risk and target volume for radiation therapy of intra-ocular tumours. The aim is to optimize the dose distribution and thus to reduce normal tissue complication probability. A geometrical 3D model based on elliptic shapes was developed that can be used for multimodal model-based segmentation of 3D patient data. The tumour volume cannot be clearly identified in CT and MR data, whereas the tumour outline can be discriminated very precisely in fundus photographs. Therefore, a multimodal 2D fundus diagram was developed, which allows us to correlate and display simultaneously information extracted from the eye model, 3D data and the fundus photograph. Thus, the connection of fundus diagram and 3D data is well-defined and the 3D volume can be calculated directly from the tumour outline drawn onto the fundus photograph and the tumour height measured by ultrasound. The method allows the calculation of a precise 3D eye model of the patient, including the different structures of the eye as well as the tumour volume. The method was developed as part of the new 3D treatment planning system OCTOPUS for proton therapy of ocular tumours within a national research project together with the Hahn-Meitner-Institut Berlin.
International Journal of Radiation Oncology Biology Physics | 2009
Juergen Biederer; Julien Dinkel; Gregor Remmert; Siri Jetter; Simeon Nill; Torsten Moser; Rolf Bendl; Carsten Thierfelder; Michael Fabel; Uwe Oelfke; Michael Bock; Christian Plathow; H. Bolte; Thomas Welzel; Beata Hoffmann; Günter Hartmann; Wolfgang Schlegel; Jürgen Debus; Martin Heller; Hans-Ulrich Kauczor
PURPOSE Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). METHODS AND MATERIALS Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24 x 10(2)/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution approximately 1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. RESULTS Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). CONCLUSIONS Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.
Computer Methods and Programs in Biomedicine | 2014
Kerstin A. Kessel; Christian Bohn; Uwe Engelmann; Dieter Oetzel; Nina Bougatf; Rolf Bendl; Jürgen Debus; Stephanie E. Combs
In radiation oncology, where treatment concepts are elaborated in interdisciplinary collaborations, handling distributed, large heterogeneous amounts of data efficiently is very important, yet challenging, for an optimal treatment of the patient as well as for research itself. This becomes a strong focus, as we step into the era of modern personalized medicine, relying on various quantitative data information, thus involving the active contribution of multiple medical specialties. Hence, combining patient data from all involved information systems is inevitable for analyses. Therefore, we introduced a documentation and data management system integrated in the clinical environment for electronic data capture. We discuss our concept and five-year experience of a precise electronic documentation system, with special focus on the challenges we encountered. We specify how such a system can be designed and implemented to plan, tailor and conduct (multicenter) clinical trials, ultimately reaching the best clinical performance, and enhancing interdisciplinary and clinical research.
Strahlentherapie Und Onkologie | 2002
Christoph Thilmann; Angelika Zabel; Sabine Kuhn; Rolf Bendl; Bernhard Rhein; Michael Wannenmacher; Jürgen Debus
Hintergrund: Eine 44-jährige Patientin mit der Indikation zur Bestrahlung bei brusterhaltender Therapie eines Mammakarzinoms war zugewiesen worden, da bei ausgeprägter Trichterbrust mit konventionellen Techniken keine zufrieden stellende Dosisverteilung erreicht werden konnte. Daher erfolgte die Bestrahlung als intensitätsmodulierte Strahlentherapie (IMRT) mit inverser Bestrahlungsplanung. Die IMRT wurde hinsichtlich der erzielten Dosisverteilung und der Durchführtbarkeit mit konventionellen Techniken verglichen. Patientin und Methoden: Bei Tumorsitz rechts unten innen beinhaltete das Zielvolumen die rechte Restbrust und den ipsilateralen parasternalen Lymphabfluss. Nach inverser Optimierung erfolgte die Bestrahlung in “Step-and-shoot”-Technik mit zwölf IMRT-Feldern mit sechs Intensitätsstufen an einem 6-MV-Linearbeschleuniger. Es wurden 50,4 Gy im Zielvolumen appliziert. Zum Vergleich wurden Bestrahlungspläne in konventioneller Technik mit zwei tangentialen irregulären 6-MV-Photonen-Feldern (Technik A) und in kombinierter Form mit zusätzlichem 15-MeV-Elektronen-Feld (Technik B) erstellt. Untersucht wurden Konformität und Homogenität im Zielvolumen und die Dosisverteilung im Normalgewebe. Ergebnisse: Die Konformität an beide Zielvolumina konnte mit IMRT erheblich verbessert werden. Die Homogenität im Zielvolumen war nur geringgradig schlechter als mit Technik A. Das Lungenvolumen, das mehr als 20 Gy erhält, konnte von 56,8% mit Technik A bzw. 40,1% mit Technik B auf 22,1% reduziert werden. Die Therapie wurde ohne nennenswerte Nebenwirkungen toleriert. Die mittlere Behandlungszeit pro Sitzung betrug 19,5 min. Schlussfolgerungen: Eine invers geplante IMRT in Vielfeldertechnik ist in der adjuvanten Situation beim Mammakarzinom einsetzbar. Im vorliegenden Fall einer Patientin mit Trichterbrust konnte im Vergleich zu konventionellen Techniken eine massive Dosisreduktion der ipsilateralen Lunge ohne Dosiseinbußen im Zielvolumen erreicht werden. Inwieweit der höhere technische Aufwand der IMRT bei der brusterhaltenden Therapie zu einem klinisch detektierbaren Vorteil führt, wird derzeit im Rahmen einer kontrollierten Studie untersucht.Background: A 44-year old woman with breast cancer was transferred to our institution for irradiation. Due to a pronounced funnel chest no satisfying dose distribution was obtained by conventional techniques. Thus an intensity-modulated radiotherapy (IMRT) based on inverse optimisation was carried out. IMRT was compared to conventional techniques regarding dose distribution and feasibility. Patient and Methods: Tumor site was in the right middle lower quadrant. Target volume included the right breast and the parasternal lymph nodes. Target dose was 50.4 Gy. Based on inverse optimisation irradiation was carried out in “step-and-shoot”-technique with twelve intensity modulated beams with six intensity steps. Additionally, treatment plans were calculated using conventional techniques (technique A with two tangential wedged 6-MV photon beams, technique B with additional oblique 15-MeV electron portal). We analysed conformality and homogeneity of target volume and dose distribution within normal tissue. Results: Dose conformality was substantially improved by IMRT. Dose homogeneity was slightly decreased compared to technique A. Lung volume irradiated with a dose higher than 20 Gy was reduced from 56.8% with technique A and 40.1% with technique B, respectively to 22.1% with IMRT. Treatment was tolerated well by the patient without relevant side effects. Mean treatment time was 19.5 min. Conclusion: The inversely planned IMRT using multiple beam directions is suitable for breast irradiation following breast conserving surgery. In the present case of a woman with funnel chest lung dose was substantially reduced without reduction of target dose. In which was the complex treatment technique leads to a clinically detectable advantage is examined at present, in the context of a study.
Physics in Medicine and Biology | 2008
Pan Li; Urban Malsch; Rolf Bendl
Modern techniques of radiotherapy like intensity modulated radiation therapy (IMRT) make it possible to deliver high dose to tumors of different irregular shapes at the same time sparing surrounding healthy tissue. However, internal tumor motion makes precise calculation of the delivered dose distribution challenging. This makes analysis of tumor motion necessary. One way to describe target motion is using image registration. Many registration methods have already been developed previously. However, most of them belong either to geometric approaches or to intensity approaches. Methods which take account of anatomical information and results of intensity matching can greatly improve the results of image registration. Based on this idea, a combined method of image registration followed by 3D modeling and simulation was introduced in this project. Experiments were carried out for five patients 4DCT lung datasets. In the 3D simulation, models obtained from images of end-exhalation were deformed to the state of end-inhalation. Diaphragm motions were around -25 mm in the cranial-caudal (CC) direction. To verify the quality of our new method, displacements of landmarks were calculated and compared with measurements in the CT images. Improvement of accuracy after simulations has been shown compared to the results obtained only by intensity-based image registration. The average improvement was 0.97 mm. The average Euclidean error of the combined method was around 3.77 mm. Unrealistic motions such as curl-shaped deformations in the results of image registration were corrected. The combined method required less than 30 min. Our method provides information about the deformation of the target volume, which we need for dose optimization and target definition in our planning system.
Journal of Applied Clinical Medical Physics | 2014
Christoph Hoffmann; Sonja Krause; Eva Maria Stoiber; Angela Mohr; Stefan Rieken; Oliver Schramm; Jürgen Debus; Florian Sterzing; Rolf Bendl; Kristina Giske
The purpose of this study was to test the accuracy of a commercially available deformable image registration tool in a clinical situation. In addition, to demonstrate a method to evaluate the resulting transformation of such a tool to a reference defined by multiple experts. For 16 patients (seven head and neck, four thoracic, five abdominal), 30‐50 anatomical landmarks were defined on recognizable spots of a planning CT and a corresponding fraction CT. A commercially available deformable image registration tool, Velocity AI, was used to align all fraction CTs with the respective planning CTs. The registration accuracy was quantified by means of the target registration error in respect to expert‐defined landmarks, considering the interobserver variation of five observers. The interobserver uncertainty of the landmark definition in our data sets is found to be 1.2±1.1mm. In general the deformable image registration tool decreases the extent of observable misalignments from 4‐8 mm to 1‐4 mm for nearly 50% of the landmarks (to 77% in sum). Only small differences are observed in the alignment quality of scans with different tumor location. Smallest residual deviations were achieved in scans of the head and neck region (79%,≤4mm) and the thoracic cases (79%,≤4mm), followed by the abdominal cases (59%,≤4mm). No difference is observed in the alignment quality of different tissue types (bony vs. soft tissue). The investigated commercially available deformable image registration tool is capable of reducing a mean target registration error to a level that is clinically acceptable for the evaluation of retreatment plans and replanning in case of gross tumor change during treatment. Yet, since the alignment quality needs to be improved further, the individual result of the deformable image registration tool has still to be judged by the physician prior to application. PACS numbers: 87.57.nj, 87.57.N‐, 87.55.‐x
International Journal of Radiation Oncology Biology Physics | 2011
Kristina Giske; Eva Maria Stoiber; Michael Schwarz; Armin Stoll; Marc W. Muenter; Carmen Timke; Falk Roeder; Juergen Debus; Peter E. Huber; Christian Thieke; Rolf Bendl
PURPOSE To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. METHODS AND MATERIALS A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. RESULTS The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. CONCLUSIONS Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future.