Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kurt J. Thome is active.

Publication


Featured researches published by Kurt J. Thome.


Bulletin of the American Meteorological Society | 2013

Achieving Climate Change Absolute Accuracy in Orbit

Bruce A. Wielicki; David F. Young; M. G. Mlynczak; Kurt J. Thome; Stephen S. Leroy; James M. Corliss; J. G. Anderson; Chi O. Ao; Richard J. Bantges; Fred A. Best; Kevin W. Bowman; Helen E. Brindley; James J. Butler; William D. Collins; John Andrew Dykema; David R. Doelling; Daniel R. Feldman; Nigel P. Fox; Xianglei Huang; Robert E. Holz; Yi Huang; Zhonghai Jin; D. Jennings; David G. Johnson; K. Jucks; Seima Kato; Daniel Bernard Kirk-Davidoff; Robert O. Knuteson; Greg Kopp; David P. Kratz

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREOs inherently high absolute accuracy will be verified and traceable on orbit to Systeme Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earths thermal infrared spectrum (5–50 μm), the spectrum of solar radiation reflected by the Earth and its atmosphere (320–2300 nm), and radio occultation refractivity from which...


IEEE Transactions on Geoscience and Remote Sensing | 2014

CLARREO Approach for Reference Intercalibration of Reflected Solar Sensors: On-Orbit Data Matching and Sampling

Carlos M. Roithmayr; Constantine Lukashin; Paul W. Speth; Greg Kopp; Kurt J. Thome; Bruce A. Wielicki; David F. Young

The implementation of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission was recommended by the National Research Council in 2007 to provide an on-orbit intercalibration standard with accuracy of 0.3% (k = 2) for relevant Earth observing sensors. The goal of reference intercalibration, as established in the Decadal Survey, is to enable rigorous high-accuracy observations of critical climate change parameters, including reflected broadband radiation [Clouds and Earths Radiant Energy System (CERES)], cloud properties [Visible Infrared Imaging Radiometer Suite (VIIRS)], and changes in surface albedo, including snow and ice albedo feedback. In this paper, we describe the CLARREO approach for performing intercalibration on orbit in the reflected solar (RS) wavelength domain. It is based on providing highly accurate spectral reflectance and reflected radiance measurements from the CLARREO Reflected Solar Spectrometer (RSS) to establish an on-orbit reference for existing sensors, namely, CERES and VIIRS on Joint Polar Satellite System satellites, Advanced Very High Resolution Radiometer and follow-on imagers on MetOp, Landsat imagers, and imagers on geostationary platforms. One of two fundamental CLARREO mission goals is to provide sufficient sampling of high-accuracy observations that are matched in time, space, and viewing angles with measurements made by existing instruments, to a degree that overcomes the random error sources from imperfect data matching and instrument noise. The data matching is achieved through CLARREO RSS pointing operations on orbit that align its line of sight with the intercalibrated sensor. These operations must be planned in advance; therefore, intercalibration events must be predicted by orbital modeling. If two competing opportunities are identified, one target sensor must be given priority over the other. The intercalibration method is to monitor changes in targeted sensor response function parameters: effective offset, gain, nonlinearity, optics spectral response, and sensitivity to polarization. In this paper, we use existing satellite data and orbital simulation methods to determine mission requirements for CLARREO, its instrument pointing ability, methodology, and needed intercalibration sampling and data matching for accurate intercalibration of RS radiation sensors on orbit. We conclude that with the CLARREO RSS in a polar 90° inclination orbit at a 609-km altitude, estimated intercalibration sampling will limit the uncertainty contribution from data matching noise to 0.3% (k = 2) over the climate autocorrelation time period. The developed orbital modeling and intercalibration event prediction will serve as a framework for future mission operations.


Proceedings of SPIE | 2009

Radiometric characterization of hyperspectral imagers using multispectral sensors

Joel McCorkel; Kurt J. Thome; Nathan Leisso; Nikolaus Anderson; Jeff Czapla-Myers

The Remote Sensing Group (RSG) at the University of Arizona has a long history of using ground-based test sites for the calibration of airborne and satellite based sensors. Often, ground-truth measurements at these tests sites are not always successful due to weather and funding availability. Therefore, RSG has also employed automated ground instrument approaches and cross-calibration methods to verify the radiometric calibration of a sensor. The goal in the cross-calibration method is to transfer the calibration of a well-known sensor to that of a different sensor. This work studies the feasibility of determining the radiometric calibration of a hyperspectral imager using multispectral imagery. The work relies on the Moderate Resolution Imaging Spectroradiometer (MODIS) as a reference for the hyperspectral sensor Hyperion. Test sites used for comparisons are Railroad Valley in Nevada and a portion of the Libyan Desert in North Africa. Hyperion bands are compared to MODIS by band averaging Hyperions high spectral resolution data with the relative spectral response of MODIS. The results compare cross-calibration scenarios that differ in image acquisition coincidence, test site used for the calibration, and reference sensor. Cross-calibration results are presented that show agreement between the use of coincident and non-coincident image pairs within 2% in most bands as well as similar agreement between results that employ the different MODIS sensors as a reference.


Proceedings of SPIE | 2009

Transmittance measurement of a heliostat facility used in the preflight radiometric calibration of Earth-observing sensors

Jeffrey S. Czapla-Myers; Kurt J. Thome; Nikolaus Anderson; Joel McCorkel; Nathan Leisso; W. Good; S. Collins

Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.


Proceedings of SPIE | 2015

Radiometric calibration of G-LiHT's imaging spectrometer using GLAMR for satellite sensor intercalibration

Amit Angal; Joel McCorkel; Bruce D. Cook; Lawrence A. Corp; Kurt J. Thome

NASA Goddard’s Lidar, Hyperspectral and Thermal Imager (G-LiHT) facilitates simultaneous measurements beneficial to variety of applications. Of the suite of “off-the shelf” instruments of G-LiHT, the Visible Near-Infrared (VNIR) Imaging Spectrometer acquires high resolution spectral measurements (1.5 nm resolution) from 0.4 to 1 μm. Goddard Space Flight Center’s Laser for Absolute Measurement of Response (GLAMR) was used to measure the absolute spectral response (ASR) of the G-LiHT’s imaging spectrometer. Continuously tunable lasers coupled to an integrating sphere allow a radiance-based calibration for the detectors at reflective solar wavelengths. GLAMR measurements, covering a wavelength range from 0.58 to 0.99 μm were acquired between July 30 to August 2, 2013. In order to account for the large field-of-view (50°), G-LiHT was rotated in 2 degree increments so that the same area of the sphere is viewed by all detectors. Using this data along with the coincident Silicon trap radiometer measurements, the ASR was computed. The derived calibration parameters for G-LiHT’s Imaging Spectrometer are to be transferred to near-simultaneous measurements of Landsat sensors. Calibration uncertainty of G-LiHT is 1-3% depending spectral region and transferring this traceability to coincident satellite sensors has 3-5% depending on spectral region.


Metrologia | 2014

Initial studies of the directional reflectance changes in pressed and sintered PTFE diffusers following exposure to contamination and ionizing radiation

G T Georgiev; James J. Butler; Kurt J. Thome; L A Ramos-Izquierdo; L Ding; L J Graziani; G A Meadows

Changes in the directional reflectance properties of pressed and sintered polytetrafluoroethylene (PTFE) diffusers induced by exposure to vacuum ultraviolet (VUV) irradiation before and after controlled contamination with Pennzane are presented in this paper. A set of 99% reflective, white, optical grade diffuse calibration standards were irradiated with a VUV source positioned at 60? to the diffuser normal. The bidirectional reflectance distribution functions before and after contamination and VUV irradiation were measured and compared at a number of scatter geometries and wavelengths in the UV, VIS and IR spectral ranges. The 8? directional hemispherical reflectance?s were also measured and compared from 200?nm to 2500?nm. Our results indicate a measureable impact of VUV irradiation on pressed and sintered PTFE diffusers as manifested by a directional dependent change in their reflectance. Such an effect needs to be considered in the on-orbit deployment of PTFE diffusers.


Earth Observing Systems XXII | 2017

Establishing BRDF calibration capabilities through shortwave infrared

Georgi T. Georgiev; James J. Butler; Kurt J. Thome; Catherine C. Cooksey; Leibo Ding

Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Distribution Functions (BRDFs) of the laboratory and flight diffusers used in their pre-flight and on-orbit calibrations. This paper advances that initial work and presents a comparison of spectral Bidirectional Reflectance Distribution Function (BRDF) and Directional Hemispherical Reflectance (DHR) of Spectralon*, a common material for laboratory and onorbit flight diffusers. A new measurement setup for BRDF measurements from 900 nm to 2500 nm located at NASA Goddard Space Flight Center (GSFC) is described. The GSFC setup employs an extended indium gallium arsenide detector, bandpass filters, and a supercontinuum light source. Comparisons of the GSFC BRDF measurements in the shortwave infrared (SWIR) with those made by the National Institute of Standards and Technology (NIST) Spectral Tri-function Automated Reference Reflectometer (STARR) are presented. The Spectralon sample used in this study was 2 inch diameter, 99% white pressed and sintered Polytetrafluoroethylene (PTFE) target. The NASA/NIST BRDF comparison measurements were made at an incident angle of 0° and viewing angle of 45° . Additional BRDF data not compared to NIST were measured at additional incident and viewing angle geometries and are not presented here. The total combined uncertainty for the measurement of BRDF in the SWIR range made by the GSFC scatterometer is less than 1% (k = 1). This study is in support of the calibration of the Radiation Budget Instrument (RBI) and Visible Infrared Imaging Radiometer Suit (VIIRS) instruments of the Joint Polar Satellite System (JPSS) and other current and future NASA remote sensing missions operating across the reflected solar wavelength region.


Proceedings of SPIE | 2016

Evaluation of GLAMR-based calibration for SI-traceable field reflectance retrievals

Amit Angal; Joel McCorkel; Kurt J. Thome

The reflected solar instrument that is part of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is being formulated with a goal of providing SI-traceable measurement of radiance that is an order of magnitude more accurate than the current imaging sensors. The Goddard Laser for Absolute Measurement of Radiance (GLAMR) is a key element to reaching such accuracy along with transferring the laboratory calibration to on-orbit measurements. Results from field reflectance retrievals using three separate instruments all of which have been calibrated using GLAMR are shown. The instruments include a commercial field spectrometer and a portable version of CLARREO’s calibration demonstration system. The third instrument is NASA Goddard’s Lidar, Hyperspectral and Thermal Imager (G-LiHT) which is an airborne system. All three were operated during a March 2013 measurement campaign at Red Lake Playa, Arizona as part of the on-orbit commissioning phase of Landsat 8. Reflectance is derived from near-coincident measurements by the three sensors for a small area of the playa. The retrieved results are SI-traceable and demonstrate the ability to transfer the GLAMR calibration to the field. Use of the G-LiHT data in the calibration of Landsat-7 and -8 sensors permits them both to be placed on the GLAMR-scale as well.


Proceedings of SPIE | 2016

Results from Source-Based and Detector-Based Calibrations of a CLARREO Calibration Demonstration System

Amit Angal; Joel McCorkel; Kurt J. Thome

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is formulated to determine long-term climate trends using SI-traceable measurements. The CLARREO mission will include instruments operating in the reflected solar (RS) wavelength region from 320 nm to 2300 nm. The Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO and facilitates testing and evaluation of calibration approaches. The basis of CLARREO and SOLARIS calibration is the Goddard Laser for Absolute Measurement of Response (GLAMR) that provides a radiance-based calibration at reflective solar wavelengths using continuously tunable lasers. SI-traceability is achieved via detector-based standards that, in GLAMR’s case, are a set of NIST-calibrated transfer radiometers. A portable version of the SOLARIS, Suitcase SOLARIS is used to evaluate GLAMR’s calibration accuracies. The calibration of Suitcase SOLARIS using GLAMR agrees with that obtained from source-based results of the Remote Sensing Group (RSG) at the University of Arizona to better than 5% (k=2) in the 720-860 nm spectral range. The differences are within the uncertainties of the NIST-calibrated FEL lamp-based approach of RSG and give confidence that GLAMR is operating at <5% (k=2) absolute uncertainties. Limitations of the Suitcase SOLARIS instrument also discussed and the next edition of the SOLARIS instrument (Suitcase SOLARIS- 2) is expected to provide an improved mechanism to further assess GLAMR and CLARREO calibration approaches.


Proceedings of SPIE | 2016

Preliminary Results of BTDF Calibration of Transmissive Solar Diffusers for Remote Sensing

Georgi Georgiev; James J. Butler; Kurt J. Thome; Catherine C. Cooksey; Leibo Ding

Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute’s (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA’s Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their onboard transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

Collaboration


Dive into the Kurt J. Thome's collaboration.

Top Co-Authors

Avatar

Joel McCorkel

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

James J. Butler

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Amit Angal

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar

Catherine C. Cooksey

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Greg Kopp

University of Colorado Boulder

View shared research outputs
Researchain Logo
Decentralizing Knowledge