Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kyoshiro Imagawa is active.

Publication


Featured researches published by Kyoshiro Imagawa.


Optics Letters | 1981

KRS-5 optical fibers capable of transmitting high-power CO 2 laser beam

Shiro Sakuragi; T. Morikawa; J. Shimada; Mitsunori Saito; Y. Kubo; Kyoshiro Imagawa; Haruo Kotani

Polycrystalline KRS-5 optical fibers were experimentally demonstrated to have high-power transmission capabilities for a cw CO(2) laser beam. A typical sample of fibers provided by extrusion, 1 mm in diameter and 0.87 m in length, carried a laser power of 68 W to its output end and was found to remain free from damage at an incoming laser intensity up to 30 kW/cm(2).


arXiv: Instrumentation and Methods for Astrophysics | 2016

Dark matter search project PICO-LON

K. Fushimi; H. Ejiri; Ryuta Hazama; H. Ikeda; Kyoshiro Imagawa; K. Inoue; Gakuji Kanzaki; A. Kozlov; R. Orito; Tatsushi Shima; Y. Takemoto; Y Teraoka; S. Umehara; Kensuke Yasuda; S. Yoshida

The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purified by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of 226Ra and 228Th were effectively reduced to 58 ± 4 µBq/kg and 1.5 ± 1.9 µBq/kg, respectively. It should be remarked that the concentration of 210Pb, which is crucial for the sensitivity to dark matter, was reduced to 24 ± 2 µBq/kg. The total background rate at 10 keVee was as low as 8 keV−1kg−1day−1, which was sufficiently low to search for dark matter. Further purification of NaI(Tl) ingot and future prospect of PICO-LON project is discussed.The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purified by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of Ra and Th were effectively reduced to 58 ± 4 μBq/kg and 1.5 ± 1.9 μBq/kg, respectively. It should be remarked that the concentration of Pb, which is crucial for the sensitivity to dark matter, was reduced to 24 ± 2 μBq/kg. The total background rate at 10 keVee was as low as 8 keV −1kg−1day−1, which was sufficiently low to search for dark matter. Further purification of NaI(Tl) ingot and future prospect of PICO-LON project is discussed. 1. Outline of PICO-LON project PICO-LON (Pure Inorganic Crystal Observatory for LOw-background Neutr(al)ino) aims at search for WIMPs by means of highly radio-pure NaI(Tl) scintillator. NaI(Tl) scintillator has great advantage to searching for WIMPs because all the nuclei are sensitive to both spindependent and spin-independent interactions. The NaI(Tl) scintillator has another advantages to WIMPs search because of its low background and easy to operate under room temperature. The DAMA/LIBRA group is continuously searching for the signal of WIMPs by highly radiopure and large volume NaI(Tl) crystals [1]. They developed highly radio-pure NaI(Tl) crystal which contains only a few ppt of U and Th chain isotope impurities and less than 20 ppb ar X iv :1 51 2. 04 64 5v 1 [ as tr oph .I M ] 1 5 D ec 2 01 5 of natural potassium [2]. Many other groups are trying to develop highly radio-pure NaI(Tl) crystals to search for WIMPs, however, the sensitivity to WIMPs are suffered from a large amount of 210Pb contamination [3, 4, 5, 6]. Recently, the PICO-LON group established the method to reduce 210Pb in NaI(Tl) crystal. One of the most serious origin of background was successfully removed and further purification and low background test was done. The final set-up of the PICO-LON detector is planned to consist of 42 modules of large volume NaI(Tl) detectors, each with 12.70 cmφ×12.70 cm. The total mass of the detector system is enough to test the annual modulation signal which is reported by DAMA/LIBRA [7]. The NaI(Tl) crystal is viewed by one photomultiplier tube (PMT) in order to lower the background events from PMTs. In the following sections, we will present the recent progresses on the crystal purification and the result of test measurement of low background measurement. 2. Development of low background NaI(Tl) scintillator The purification of NaI(Tl) ingot is the most important task to develop the high sensitivity detector to search for WIMPs because radioactive impurities (RI) in the NaI(Tl) crystal reduces the sensitivity to the WIMPs seriously. The impurities of RIs in a crystal scintillator should be less than a few tens of μBq/kg in order to use the crystal for dark matter search. The contamination of 210Pb is the serious backgrounds because it emits low energy beta rays (Emax = 17 keV and 63.5 keV), the low energy gamma ray and the conversion electron (Eγ = 46.5 keV) and L-X rays below 16 keV. The 210Bi, the progeny of 210Pb, emits high energy beta ray (Emax = 1162 keV) which produces bremsstrahlung photons. All the radiations associated with 210Pb severely reduce the sensitivity to WIMPs signal. Although it is quite difficult to reduce the concentration of 210Pb, we have successfully reduced its concentration by chemical process of raw NaI powder. We tried to remove the Pb ion in the raw powder of NaI by cation exchange resin which was optimized to remove the Pb ion. The raw NaI powder was dissolved in ultra pure water with the concentration of 300 g/Liter. The NaI solution was poured into a column in which the cation exchange resin was filled. The best parameter was searched for and determined to optimize the reduction of lead ion by several trials. The processed solution was dried by rotary vacuum evaporator. The vacuum of the evaporator was broken by high purity nitrogen gas to avoid the contamination by 222Rn in the air. As a result, the concentration of 210Pb became as small as 24 ± 2 μBq/kg. The U-chain (238U and 226Ra) and Th-chain (228Th) were effectively reduced by purifying the raw material of a graphite crucible. The graphite was selected based on results of U, Th and K measurements, however, we found the purity of the graphite was not sufficiently good because a significant contamination of U-chain and Th-chain were observed. Further purification of graphite was done by baking the graphite under 3000 K. The concentration of 226Ra and 228Th were successfully reduced to 58 ± 4 μBq/kg and 1.5 ± 1.9 μBq/kg, respectively. 3. Low background measurement in Kamioka underground observatory The NaI(Tl) ingot was shaved and polished to make 7.62 cmφ×7.62 cm cylindrical shape. A quartz light guide with 4 mm in thickness was glued on the top of the cylindrical NaI(Tl) ingot. All other surfaces of the ingot was covered with 4 mm thick PTFE reflector to guide the scintillation photons to the light guide. The ingot and the light guide were covered with 0.08 cm thick oxygen free high conductive copper (OFHC). The NaI(Tl) detector was covered with 5 cm thick OFHC copper and 20 cm thick old lead passive shield. No active shield was installed in the present measurement. The minimum thickness of the lead shield was 18 cm. Fast neutrons were thermalized and absorbed by 5 cm thick borated polyethylene. Pure nitrogen gas evaporated from liquid nitrogen was flushed into the inner area of the shield to purge radon. The schematic drawing of the detector system is shown in Figure 1. Figure 1. Geometry of the present measurement in Kamioka underground observatory. The low background measurement was started in the summer of 2015 in Kamioka underground laboratory (36◦25’N, 137◦18’E) located at 2700 m water equivalent. The experiment area was placed in the area of KamLAND experiment. The air of the experimental room was controlled to keep clean as class 10 by using a HEPA filter. The flux of the cosmic ray is reduced by a factor of 10−5 relative to the flux in the surface laboratory. A low background photomultiplier tube (PMT) R11065-20 provided by Hamamatsu Photonics was attached on the light guide by optical grease. The concentrations of U and Th chain in the PMT were less than 10 mBq/module. The quantum efficiency was as large as 30 % at the wavelength of 420 nm. The PMT output pulse was introduced into the fast data acquisition system MoGURA (Module for General Use Rapid Application)[8] to digitize the pulse shape. The trigger for the data acquisition system was produced by timing filter amplifier (TFA) which integrates 200 nsec. The fast noise pulses below single photoelectron signals are effectively removed by introducing TFA and the trigger rate was reduced by about two order of magnitude. Energy calibration for higher energy range was performed by using 133Ba and 40K (KCl) sources. The energy resolution at 1.46 MeV was 6.9 % in full-width-half-maximum (FWHM). Figure 2. The energy spectra obtained by irradiating 133Ba (upper orange) and background (lower green). Low background measurement was continued for the live time of 7 days× 1.2 kg. The energy spectra of energy calibration and low background measurements are shown in Figure 2. The background energy spectrum was well reproduced by Monte Carlo simulation with the concentration of the RIs in the surrounding materials. The present energy threshold was 10 keVee and the event rate was 8 keV−1kg−1day−1at the energy threshold. 4. Future prospects We developed highly radio-pure NaI(Tl) crystal to search for cosmic dark matter. The RIs of U-chain and Th-chain were sufficiently reduced by purification of the raw NaI powder and the graphite crucible. The significant potassium impurity was observed in the low background measurement. The Monte Carlo simulation agreed with the assumption that the 2.6 ppm of potassium was contained in NaI(Tl) crystal. The concentration of potassium was too large to use the crystal to the dark matter search. The chemical process to remove the potassium in NaI raw powder is now in progress. The background from the surrounding materials is the next important issue. All the materials which will be used for the detector are selected by measuring the gamma rays from the samples. We started the collaboration with the XMASS group to lower the background from PMTs. Extensive search for the low background materials will be finished in the beginning of 2016 and low background PMT will be developed for PICO-LON in 2016. Full background simulation of 250 kg PICO-LON setup is now ongoing. The detail of the detector design is fixing by discussing with Horiba and Hamamatsu Photonics. The detector design will be optimized to ensure the background rejection by making unti-coincidence measurements of background events such as potassium, 1461 keV gamma ray and 3 keV X ray. 5. Acknowledgment The authors thank Professor S.Nakayama for fruitful discussion and encouragement. The authors also thank Kamioka Mining and Smelting Company for supporting activities in the Kamioka mine and Horiba Ltd. for making the NaI(Tl) detectors. This work was supported by Grantin-Aid for Scientific Research (B) number 24340055, Grant-in-Aid for Scientific Research on Innovative Areas number 26104008. The work was also supported by Creative Research Project in Institute of Socio, Arts and Sciences, Tokushima University. The corresponding author thanks Nogami Fund at RCNP Osaka University for the travel support to attend TAUP 2015.


arXiv: Instrumentation and Methods for Astrophysics | 2016

High purity NaI(Tl) scintillator to search for dark matter

K. Fushimi; H. Ejiri; Ryuta Hazama; H. Ikeda; K. Inoue; Kyoshiro Imagawa; Gakuji Kanzaki; A. Kozlov; R. Orito; Tatsushi Shima; Y. Takemoto; Y Teraoka; S. Umehara; S. Yoshida

A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powder. The impurity of


Journal of Physics: Conference Series | 2010

MOON for double-beta decays and neutrino nuclear responses

K. Fushimi; Y Kameda; K Harada; S. Nakayama; H. Ejiri; Tatsushi Shima; K Yasuda; R. Hazama; Kyoshiro Imagawa

^{226}


Journal of Physics: Conference Series | 2010

Dark matter search by means of segmented scintillator (PICO-LON)

K. Fushimi; Y Kameda; K Harada; S. Nakayama; H. Ejiri; Tatsushi Shima; K Yasuda; S. Umehara; R. Hazama; Kyoshiro Imagawa

Ra was reduced less than 100


Journal of Physics: Conference Series | 2008

PICO-LON project for WIMPs search

K. Fushimi; Kensuke Yasudai; Yuuki Kamedai; H. Ejiri; R. Hazama; K. Ichihara; Kyoshiro Imagawa; Hiroshi Ito; N. Koori; Hidehito Nakamura; S. Nakayama; M. Nomachi; T. Shima; S. Umehara; S. Yoshida

\mu


Journal of the Physical Society of Japan | 2006

The Performance of Thin NaI(Tl) Scintillator Plate for Dark Matter Search

K. Fushimi; H. Kawasuso; E. Aihara; R. Hayami; M. Toi; Kensuke Yasuda; S. Nakayama; N. Koori; M. Nomachi; K. Ichihara; R. Hazama; S. Yoshida; S. Umehara; Kyoshiro Imagawa; Hiroshi Ito

Bq/kg in NaI(Tl) crystal. It should be remarked that the impurity of


THE 10TH INTERNATIONAL SYMPOSIUM ON ORIGIN OF MATTER AND EVOLUTION OF GALAXIES: OMEG—2010 | 2010

PICO‐LON project to search for cosmic dark matter

K. Fushimi; H. Ejiri; K Harada; R. Hazama; Kyoshiro Imagawa; Y. Kameda; Erika Matsumoto; S. Nakayama; Tatsushi Shima

^{210}


Journal of Physics: Conference Series | 2006

WIMPs search by means of thin NaI(Tl) array

K. Fushimi; H. Kawasuso; E. Aihara; R. Hayami; N. Koori; S. Nakayama; Kensuke Yasuda; R. Hazama; K. Ichihara; Hidehito Nakamura; M. Nomachi; Takeo Ogama; S. Umehara; S. Yoshida; H. Ejiri; Kyoshiro Imagawa; Hiroshi Ito

Pb, which is difficult to reduce, is effectively reduced by chemical processing of NaI raw powder down to less than 30


Archive | 1981

Laser surgical knife

Kyoshiro Imagawa; Tomoyuki Haga

\mu

Collaboration


Dive into the Kyoshiro Imagawa's collaboration.

Top Co-Authors

Avatar

K. Fushimi

University of Tokushima

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ryuta Hazama

Osaka Sangyo University

View shared research outputs
Top Co-Authors

Avatar

S. Nakayama

University of Tokushima

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge