Featured researches published by L Santanam.


International Journal of Radiation Oncology Biology Physics | 2009

Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking.

Amit Sawant; Ryan L. Smith; Raghu Venkat; L Santanam; Byungchul Cho; P.R. Poulsen; Herbert Cattell; Laurence J. Newell; Parag J. Parikh; P Keall

PURPOSE We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). METHODS AND MATERIALS In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. RESULTS System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. CONCLUSION We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.


International Journal of Radiation Oncology Biology Physics | 2008

Prospective Clinical Trial of Positron Emission Tomography/Computed Tomography Image-Guided Intensity-Modulated Radiation Therapy for Cervical Carcinoma With Positive Para-Aortic Lymph Nodes

Jacqueline Esthappan; S Chaudhari; L Santanam; Sasa Mutic; J.R. Olsen; Dusten M. Macdonald; Daniel A. Low; Anurag K. Singh; Perry W. Grigsby

PURPOSE To describe a more aggressive treatment technique allowing dose escalation to positive para-aortic lymph nodes (PALN) in patients with cervical cancer, by means of positron emission tomography (PET)/computed tomography (CT)-guided intensity-modulated radiation therapy (IMRT). Here, we describe methods for simulation and planning of these treatments and provide objectives for target coverage as well as normal tissue sparing to guide treatment plan evaluation. METHODS AND MATERIALS Patients underwent simulation on a PET/CT scanner. Treatment plans were generated to deliver 60.0 Gy to the PET-positive PALN and 50.0 Gy to the PALN and pelvic lymph node beds. Treatment plans were optimized to deliver at least 95% of the prescribed doses to at least 95% of each target volume. Dose-volume histograms were calculated for normal structures. RESULTS The plans of 10 patients were reviewed. Target coverage goals were satisfied in all plans. Analysis of dose-volume histograms indicated that treatment plans involved irradiation of approximately 50% of the bowel volume to at least 25.0 Gy, with less than 10% receiving at least 50.0 Gy and less than 1% receiving at least 60.0. With regard to kidney sparing, approximately 50% of the kidney volume received at least 16.0 Gy, less than 5% received at least 50.0 Gy, and less than 1% received at least 60.0 Gy. CONCLUSIONS We have provided treatment simulation and planning methods as well as guidelines for the evaluation of target coverage and normal tissue sparing that should facilitate the more aggressive treatment of cervical cancer.


International Journal of Radiation Oncology Biology Physics | 2012

Standardizing Naming Conventions in Radiation Oncology

L Santanam; Coen W. Hurkmans; Sasa Mutic; Corine van Vliet-Vroegindeweij; S Brame; William L. Straube; James M. Galvin; Prabhakar Tripuraneni; Jeff M. Michalski; Walter R. Bosch

PURPOSE The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. MATERIALS AND METHODS The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. RESULTS In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. CONCLUSIONS Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).


Medical Physics | 2012

Quality assurance for nonradiographic radiotherapy localization and positioning systems: Report of Task Group 147

Twyla R. Willoughby; Joerg Lehmann; J BenComo; Shirish Jani; L Santanam; A. Sethi; Timothy D. Solberg; Wolfgang A. Tomé; Timothy J. Waldron

New technologies continue to be developed to improve the practice of radiation therapy. As several of these technologies have been implemented clinically, the Therapy Committee and the Quality Assurance and Outcomes Improvement Subcommittee of the American Association of Physicists in Medicine commissioned Task Group 147 to review the current nonradiographic technologies used for localization and tracking in radiotherapy. The specific charge of this task group was to make recommendations about the use of nonradiographic methods of localization, specifically; radiofrequency, infrared, laser, and video based patient localization and monitoring systems. The charge of this task group was to review the current use of these technologies and to write quality assurance guidelines for the use of these technologies in the clinical setting. Recommendations include testing of equipment for initial installation as well as ongoing quality assurance. As the equipment included in this task group continues to evolve, both in the type and sophistication of technology and in level of integration with treatment devices, some of the details of how one would conduct such testing will also continue to evolve. This task group, therefore, is focused on providing recommendations on the use of this equipment rather than on the equipment itself, and should be adaptable to each users situation in helping develop a comprehensive quality assurance program.


International Journal of Radiation Oncology Biology Physics | 2009

INTEGRATION OF REAL-TIME INTERNAL ELECTROMAGNETIC POSITION MONITORING COUPLED WITH DYNAMIC MULTILEAF COLLIMATOR TRACKING: AN INTENSITY-MODULATED RADIATION THERAPY FEASIBILITY STUDY

Ryan L. Smith; Amit Sawant; L Santanam; Raghu Venkat; Laurence J. Newell; Byung Chul Cho; P.R. Poulsen; Herbert Catell; P Keall; Parag J. Parikh

PURPOSE Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. METHODS AND MATERIALS A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. RESULTS Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: +/-3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. CONCLUSIONS Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.


International Journal of Radiation Oncology Biology Physics | 2008

FIDUCIAL-BASED TRANSLATIONAL LOCALIZATION ACCURACY OF ELECTROMAGNETIC TRACKING SYSTEM AND ON-BOARD KILOVOLTAGE IMAGING SYSTEM

L Santanam; K Malinowski; James Hubenshmidt; Steve Dimmer; Martin L. Mayse; Jeffrey D. Bradley; Amir Chaudhari; Kirsten Lechleiter; Sree Krishna Murty Goddu; Jacqueline Esthappan; Sasa Mutic; Daniel A. Low; Parag J. Parikh

PURPOSE The Calypso medical four-dimensional localization system uses AC electromagnetics, which do not require ionizing radiation, for accurate, real-time tumor tracking. This investigation compared the static and dynamic tracking accuracy of this system to that of an on-board imaging kilovoltage X-ray system for concurrent use of the two systems. METHODS AND MATERIALS The localization accuracies of a kilovoltage imaging system and a continuous electromagnetic tracking system were compared. Using an in-house developed four-dimensional stage, quality-assurance fixture containing three radiofrequency transponders was positioned at a series of static locations and then moved through the ellipsoidal and nonuniform continuous paths. The transponder positions were tracked concurrently by the Calypso system. For static localization, the transponders were localized using portal images and digitally reconstructed radiographs by commercial matching software. For dynamic localization, the transponders were fluoroscopically imaged, and their positions were determined retrospectively using custom-written image processing programs. The localization data sets were synchronized with and compared to the known quality assurance fixture positions. The experiment was repeated to retrospectively track three transponders implanted in a canine lung. RESULTS The root mean square error of the on-board imaging and Calypso systems was 0.1 cm and 0.0 cm, respectively, for static localization, 0.22 mm and 0.33 mm for dynamic phantom positioning, and 0.42 mm for the canine study. CONCLUSION The results showed that both localization systems provide submillimeter accuracy. The Calypso and on-board imaging tracking systems offer distinct sets of advantages and, given their compatibility, patients could benefit from the complementary nature of the two systems when used concurrently.


Radiotherapy and Oncology | 2015

Benchmark IMRT evaluation of a Co-60 MRI-guided radiation therapy system

H. Omar Wooten; V Rodriguez; O.L. Green; R. Kashani; L Santanam; Kari Tanderup; Sasa Mutic; H. Harold Li

A device for MRI-guided radiation therapy (MR-IGRT) that uses cobalt-60 sources to deliver intensity modulated radiation therapy is now commercially available. We investigated the performance of the treatment planning and delivery system against the benchmark recommended by the American Association of Physicists in Medicine (AAPM) Task Group 119 for IMRT commissioning and demonstrated that the device plans and delivers IMRT treatments within recommended confidence limits and with similar accuracy as linac IMRT.


Medical Physics | 2009

Quality assurance for clinical implementation of an electromagnetic tracking system

L Santanam; C. Noel; Twyla R. Willoughby; Jacqueline Esthappan; Sasa Mutic; Eric E. Klein; Daniel A. Low; Parag J. Parikh

The Calypso Medical 4D localization system utilizes alternating current electromagnetics for accurate, real-time tumor tracking. A quality assurance program to clinically implement this system is described here. Testing of the continuous electromagnetic tracking system (Calypso Medical Technologies, Seattle, WA) was performed using an in-house developed four-dimensional stage and a quality assurance fixture containing three radiofrequency transponders at independently measured locations. The following tests were performed to validate the Calypso system: (a) Localization and tracking accuracy, (b) system reproducibility, (c) measurement of the latency of the tracking system, and (d) measurement of transmission through the Calypso table overlay and the electromagnetic array. The translational and rotational localization accuracies were found to be within 0.01 cm and 1.0 degree, respectively. The reproducibility was within 0.1 cm. The average system latency was measured to be within 303 ms. The attenuation by the Calypso overlay was measured to be 1.0% for both 6 and 18 MV photons. The attenuations by the Calypso array were measured to be 2% and 1.5% for 6 and 18 MV photons, respectively. For oblique angles, the transmission was measured to be 3% for 6 MV, while it was 2% for 18 MV photons. A quality assurance process has been developed for the clinical implementation of an electromagnetic tracking system in radiation therapy.


International Journal of Radiation Oncology Biology Physics | 2013

An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

Stephanie A. Terezakis; Kendra Harris; Eric C. Ford; Jeff M. Michalski; Theodore L. DeWeese; L Santanam; Sasa Mutic

PURPOSE Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). METHODS AND MATERIALS All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. RESULTS Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. CONCLUSIONS A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.


Physics in Medicine and Biology | 2010

An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking.

C. Noel; L Santanam; J.R. Olsen; K.W. Baker; Parag J. Parikh

Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects of intra- and inter-fraction target motion for prostate cancer patients using fiducial-based electromagnetic tracking. A computer program utilizing real-time tracking data was written to (1) prospectively determine appropriate rotational/translational motion limits for patients treated with continuous isocenter localization; (2) retrospectively analyze dosimetric target coverage after daily treatment, and (3) visualize three-dimensional rotations and translations of the prostate with respect to the planned target volume and dose matrix. We present phantom testing and a patient case to validate and demonstrate the utility of this application. Gamma analysis of planar dose computed by our application demonstrated accuracy within 1%/1 mm. Dose computation of a patient treatment revealed high variation in minimum dose to the prostate (D(min)) over 40 fractions and a drop in the D(min) of approximately 8% between a 5 mm and a 3 mm PTV margin plan. The infrastructure has been created for patient-specific treatment evaluation using continuous tracking data. This application can be used to increase confidence in treatment delivery to targets influenced by motion.

Collaboration


Dive into the L Santanam's collaboration.

Top Co-Authors

Avatar

Sasa Mutic

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Parag J. Parikh

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

S Goddu

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

C. Noel

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

O.L. Green

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Jeffrey D. Bradley

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

R. Kashani

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

D Low

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Eric E. Klein

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Jacqueline Esthappan

Washington University in St. Louis

View shared research outputs
Researchain Logo
Decentralizing Knowledge