Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lars Niclauss is active.

Publication


Featured researches published by Lars Niclauss.


Interactive Cardiovascular and Thoracic Surgery | 2010

Right ventricular rupture due to recurrent mediastinal infection with a closed chest

Lars Niclauss; Dominique Delay; Frank Stumpe

Right ventricular (RV) rupture in cases of mediastinitis following cardiac surgery is a rare and dangerous complication. Bleeding from the right ventricle occurs mainly after sternal reopening, due to either iatrogenic manipulation (wire removal, lesions due to wiring maneuvers) or mechanical shearing forces, producing direct injury. We present a case of RV wall perforation due to infection in a recurrent postoperative mediastinitis with a closed chest. The current literature on treatment of postoperative mediastinitis is also reviewed.


Interactive Cardiovascular and Thoracic Surgery | 2013

Aortic biological valve prosthesis in patients younger than 65 years of age: transition to a flexible age limit?

Lars Niclauss; Ludwig Karl von Segesser; Enrico Ferrari

OBJECTIVES Guidelines proposed bioprosthesis implantation for aortic valve disease if the patients were at least 65 years old at the time of surgery, with a trend towards even younger patients in recent years. Considering the adverse effects of lifetime anticoagulation, new biological valves (less prone to degeneration) and new technologies may lead patients and surgeons to different choices. Therefore, it is interesting to analyse the results of aortic bioprosthetic valve replacement in patients aged <65 years at the time of surgery. METHODS From January 2000 to December 2010, 84 patients aged <65 years at the time of surgery had undergone an aortic bio-prosthetic valve replacement. A mid-term follow-up [(FU) mean FU time: 54.4 ± 39.2 months] was done in August 2011 in all patients (FU completeness: 100%). Results were compared with patients who had a mechanical prosthetic aortic valve replacement during the same period. RESULTS The reoperation rate for structural valve degeneration (SVD) of bioprostheses was 6% and occurred exclusively among patients <56 years. Contraindications for anticoagulation determined the choice of a bioprosthesis among 83% of these patients. The personal preference to avoid anticoagulation was the leading cause in 68% of the older patients (56-65 years). Neurological complications occurred more frequently in the mechanical control group. CONCLUSIONS Reoperations for SVD after bioprosthesis implantation occurred exclusively among younger patients (<56 years), not suitable for systemic anticoagulation. Previous studies, together with our experience, are in favour of an age limit between 56 and 60 years, taking into consideration alternative transcatheter approaches to SVD treatment.


European Journal of Cardio-Thoracic Surgery | 2017

Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: a critical review.

Lars Niclauss

Transit time flow measurement (TTFM) is a quality control tool for intraoperative graft evaluation in coronary artery bypass graft (CABG) surgery. A critical review of the literature available using TTFM in CABG surgery is the focus of this article. The main objectives will be to detail precise parameters for flow evaluation, to show limitations of TTFM and to prove its predictive impact on postoperative graft failure rate. Publications listed in the PubMed database were reviewed, searching for intraoperative graft verification in coronary surgery by TTFM, with postoperative imaging follow-up (FU) modality and with a special focus on publications released after European guidelines from 2010. Nine included publications revealed an overall graft failure rate of ∼12%. Mean graft flow had a positive predictive value in the largest study, and cut-offs, of at least 20 ml/min for internal mammary artery (IMA) grafts, therein partially confirming guidelines, and 30–40 ml/min for saphenous venous grafts (SVGs) were proposed. An explicit correlation between graft flow, patency rate and severity of coronary stenosis, by indicating the fractional flow reserve, was found for IMA grafts. Increased pulsatility index and increased systolic reverse flow probably predict worse outcome and may help identifying competitive flow. Diastolic filling, rarely indicated, could not be confirmed as the predictive marker. No significant correlation of TTFM and graft failure rate for radial and other arterial grafts could be found, partially due to the small number of these types of grafts analysed. Larger target vessels and lower postoperative CK-MB levels may predict better graft patency rates. Low sensitivity for TTFM to reliably detect graft failure is certainly a major issue, as found in randomized analyses. However, methodical limitations and varying threshold values for TTFM render a general consensus difficult. Influence of quantity (vessel territory distribution) and quality (myocardial scar) of the graft perfusion area, on TTFM and FU outcome, was not included by anyone and should be part of future research. TTFM is probably not the tool of choice to detect progressive late graft failure of SVG. Peroperative TTFM values should be correlated with one type of conduit, differentiating between early and late graft failure (by applying a uniform, appropriated definition), to precise and confirm threshold values.


The Annals of Thoracic Surgery | 2014

Surgical Procedure in Immunoglobulin G4–Related Ascending Aortitis?

Sébastien Colombier; P. Ruchat; Fabrizio Gronchi; René Prêtre; Lars Niclauss

Immunoglobulin G4 (IgG4)-related fibroinflammatory systemic disease accounts for 7% of all noninfectious aneurysms of the thoracic aorta. A patient was admitted with a symptomatic ascending aortic aneurysm and thickened aortic wall (outer/inner diameter 55/45 mm), which was replaced. Probes revealed IgG4-related aortitis associated with a primary tuberculosis infection. Corticosteroid and antituberculosis therapies were used, and the patients clinical evolution was favorable. The optimal treatment strategy of IgG4-related aortitis, a new entity, remains vague. Inner aortic diameter alone does not justify aortic replacement, but wall thickening may mimic intramural hematoma. In this particular case of IgG4-related aortitis, immunosuppressive treatment alone, as an alternative to a surgical procedure, may be debatable.


European Journal of Cardio-Thoracic Surgery | 2014

On-pump fibrillating heart mitral valve replacement with the SAPIEN™ XT transcatheter heart valve

Enrico Ferrari; Lars Niclauss; Didier Locca; Carlo Marcucci

In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien™ XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.


European Journal of Cardio-Thoracic Surgery | 2011

Imaging for trans-catheter pulmonary stent-valve implantation without angiography: role of intravascular ultrasound

Enrico Ferrari; Lars Niclauss; Denis Berdajs; Ludwig Karl von Segesser

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien™ THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.


Interactive Cardiovascular and Thoracic Surgery | 2009

Total aortic arch stenting – hemodynamical impact of carotid artery perfusion

Lars Niclauss; Ludwig K. von Segesser

The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.


Annals of Vascular Surgery | 2010

Therapy of acute massive pulmonary embolism associated with Klippel-Trenaunay syndrome.

Lars Niclauss; Dominique Delay; Enrico Ferrari; Philippe Gersbach; Frank Stumpe; Ludwig K. von Segesser

Acute massive pulmonary embolism (PE) is a life-threatening event. Before the era of cardiopulmonary bypass, acute pulmonary embolectomy had been historically attempted in patients with severe hemodynamic compromise. The Klippel-Trenaunay syndrome (KTS) represents a significant life-long risk for major thromboembolic events. We present two young patients with Klippel-Trenaunay syndrome who survived surgical embolectomy after massive PE and cardiopulmonary resuscitation, with good postoperative recovery. Even though the role of surgical embolectomy in massive PE is not clearly defined, with current technology it can be life saving and can lead to a complete recovery, especially in young patients as described in this study.


Asian Cardiovascular and Thoracic Annals | 2015

Single Heartstring aortotomy for multiple off-pump venous bypass grafts

Lars Niclauss; Sébastien Colombier; René Prêtre

Off-pump coronary bypass grafting may decrease the rate of stroke, due to minimal aortic manipulation. For venous grafts, clampless hemostasis when performing the proximal anastomosis can be achieved using the Heartstring device. We describe a technique using a single device to suture two veins to one aortotomy. This technique requires less space and could be advantageous in very short, small, and calcified aortas. In to our experience, this technique is rapid, simple, easy to reproduce, and cost-saving.


Asian Cardiovascular and Thoracic Annals | 2017

Low pacemaker incidence with continuous-sutured valves: a retrospective analysis

Lars Niclauss; Dominique Delay; Raymond Pfister; Sébastien Colombier; Matthias Kirsch; René Prêtre

Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay (p = 0.01), preexisting rhythm disorders (p < 0.001), complex prosthetic endocarditis (p = 0.01), and complex redo (p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group (p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

Collaboration


Dive into the Lars Niclauss's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Enrico Ferrari

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

René Prêtre

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar

Ludwig Karl von Segesser

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar

Denis Berdajs

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar

Sébastien Colombier

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Matthias Kirsch

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

Michel Hurni

University Hospital of Lausanne

View shared research outputs
Researchain Logo
Decentralizing Knowledge