International Journal of Radiation Oncology Biology Physics | 2014

Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time

Lesley A. Jarvis; Rongxiao Zhang; David J. Gladstone; Shudong Jiang; Whitney Hitchcock; Oscar D. Friedman; Adam K. Glaser; Michael Jermyn; Brian W. Pogue

PURPOSE To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. METHODS AND MATERIALS An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). RESULTS The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans, mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. CONCLUSIONS Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.


Academic Radiology | 2014

Clinical EPR: Unique Opportunities and Some Challenges

Harold M. Swartz; Benjamin B. Williams; Bassem I. Zaki; Alan C. Hartford; Lesley A. Jarvis; Eunice Y. Chen; Richard J. Comi; Marc S. Ernstoff; Huagang Hou; Nadeem Khan; Steven G. Swarts; Ann Barry Flood; Periannan Kuppusamy

Electron paramagnetic resonance (EPR) spectroscopy has been well established as a viable technique for measurement of free radicals and oxygen in biological systems, from in vitro cellular systems to in vivo small animal models of disease. However, the use of EPR in human subjects in the clinical setting, although attractive for a variety of important applications such as oxygen measurement, is challenged with several factors including the need for instrumentation customized for human subjects, probe, and regulatory constraints. This article describes the rationale and development of the first clinical EPR systems for two important clinical applications, namely, measurement of tissue oxygen (oximetry) and radiation dose (dosimetry) in humans. The clinical spectrometers operate at 1.2 GHz frequency and use surface-loop resonators capable of providing topical measurements up to 1 cm depth in tissues. Tissue pO2 measurements can be carried out noninvasively and repeatedly after placement of an oxygen-sensitive paramagnetic material (currently India ink) at the site of interest. Our EPR dosimetry system is capable of measuring radiation-induced free radicals in the tooth of irradiated human subjects to determine the exposure dose. These developments offer potential opportunities for clinical dosimetry and oximetry, which include guiding therapy for individual patients with tumors or vascular disease by monitoring of tissue oxygenation. Further work is in progress to translate this unique technology to routine clinical practice.


International Journal of Radiation Oncology Biology Physics | 2012

Tumor Bed Dynamics After Surgical Resection of Brain Metastases: Implications for Postoperative Radiosurgery

Lesley A. Jarvis; Nathan E. Simmons; Marc R. Bellerive; Kadir Erkmen; Clifford J. Eskey; David J. Gladstone; Eugen B. Hug; David W. Roberts; Alan C. Hartford

PURPOSE To analyze 2 factors that influence timing of radiosurgery after surgical resection of brain metastases: target volume dynamics and intracranial tumor progression in the interval between surgery and cavity stereotactic radiosurgery (SRS). METHODS AND MATERIALS Three diagnostic magnetic resonance imaging (MRI) scans were retrospectively analyzed for 41 patients with a total of 43 resected brain metastases: preoperative MRI scan (MRI-1), MRI scan within 24 hours after surgery (MRI-2), and MRI scan for radiosurgery planning, which is generally performed ≤1 week before SRS (MRI-3). Tumors were contoured on MRI-1 scans, and resection cavities were contoured on MRI-2 and MRI-3 scans. RESULTS The mean tumor volume before surgery was 14.23 cm3, and the mean cavity volume was 8.53 cm3 immediately after surgery and 8.77 cm3 before SRS. In the interval between surgery and SRS, 20 cavities (46.5%) were stable in size, defined as a change of ≤2 cm3; 10 cavities (23.3%) collapsed by >2 cm3; and 13 cavities (30.2%) increased by >2 cm3. The unexpected increase in cavity size was a result of local progression (2 cavities), accumulation of cyst-like fluid or blood (9 cavities), and nonspecific postsurgical changes (2 cavities). Finally, in the interval between surgery and SRS, 5 cavities showed definite local tumor progression, 4 patients had progression elsewhere in the brain, 1 patient had both local progression and progression elsewhere, and 33 patients had stable intracranial disease. CONCLUSIONS In the interval between surgical resection and delivery of SRS, surgical cavities are dynamic in size; however, most cavities do not collapse, and nearly one-third are larger at the time of SRS. These observations support obtaining imaging for radiosurgery planning as close to SRS delivery as possible and suggest that delaying SRS after surgery does not offer the benefit of cavity collapse in most patients. A prospective, multi-institutional trial will provide more guidance to the optimal timing of cavity SRS.


Health Physics | 2012

ELECTRON PARAMAGNETIC RESONANCE DOSIMETRY FOR A LARGE-SCALE RADIATION INCIDENT

Harold M. Swartz; Ann Barry Flood; Benjamin B. Williams; Ruhong Dong; Steven G. Swarts; Xiaoming He; Oleg Y. Grinberg; Jason W. Sidabras; Eugene Demidenko; Jiang Gui; David J. Gladstone; Lesley A. Jarvis; Maciej M. Kmiec; Kyo Kobayashi; Piotr Lesniewski; Stephen D.P. Marsh; Thomas P. Matthews; Roberto J. Nicolalde; Patrick M. Pennington; Timothy Raynolds; Ildar Salikhov; Dean E. Wilcox; Bassem I. Zaki

Abstract With possibilities for radiation terrorism and intensified concerns about nuclear accidents since the recent Fukushima Daiichi event, the potential exposure of large numbers of individuals to radiation that could lead to acute clinical effects has become a major concern. For the medical community to cope with such an event and avoid overwhelming the medical care system, it is essential to identify not only individuals who have received clinically significant exposures and need medical intervention but also those who do not need treatment. The ability of electron paramagnetic resonance to measure radiation-induced paramagnetic species, which persist in certain tissues (e.g., teeth, fingernails, toenails, bone, and hair), has led to this technique becoming a prominent method for screening significantly exposed individuals. Although the technical requirements needed to develop this method for effective application in a radiation event are daunting, remarkable progress has been made. In collaboration with General Electric and through funding committed by the Biomedical Advanced Research and Development Authority, electron paramagnetic resonance tooth dosimetry of the upper incisors is being developed to become a Food and Drug Administration-approved and manufacturable device designed to carry out triage for a threshold dose of 2 Gy. Significant progress has also been made in the development of electron paramagnetic resonance nail dosimetry based on measurements of nails in situ under point-of-care conditions, and in the near future this may become a second field-ready technique. Based on recent progress in measurements of nail clippings, it is anticipated that this technique may be implementable at remotely located laboratories to provide additional information when the measurements of dose on-site need to be supplemented. The authors conclude that electron paramagnetic resonance dosimetry is likely to be a useful part of triage for a large-scale radiation incident.


Journal of Biomedical Optics | 2013

Real-time in vivo Cherenkoscopy imaging during external beam radiation therapy

Rongxiao Zhang; David J. Gladstone; Lesley A. Jarvis; Rendall R. Strawbridge; P. Jack Hoopes; Oscar D. Friedman; Adam K. Glaser; Brian W. Pogue

Abstract. Cherenkov radiation is induced when charged particles travel through dielectric media (such as biological tissue) faster than the speed of light through that medium. Detection of this radiation or excited luminescence during megavoltage external beam radiotherapy (EBRT) can allow emergence of a new approach to superficial dose estimation, functional imaging, and quality assurance for radiation therapy dosimetry. In this letter, the first in vivo Cherenkov images of a real-time Cherenkoscopy during EBRT are presented. The imaging system consisted of a time-gated intensified charge coupled device (ICCD) coupled with a commercial lens. The ICCD was synchronized to the linear accelerator to detect Cherenkov photons only during the 3.25-μs radiation bursts. Images of a tissue phantom under irradiation show that the intensity of Cherenkov emission is directly proportional to radiation dose, and images can be acquired at 4.7  frames/s with SNR>30. Cherenkoscopy was obtained from the superficial regions of a canine oral tumor during planned, Institutional Animal Care and Use Committee approved, conventional (therapeutically appropriate) EBRT irradiation. Coregistration between photography and Cherenkoscopy validated that Cherenkov photons were detected from the planned treatment region. Real-time images correctly monitored the beam field changes corresponding to the planned dynamic wedge movement, with accurate extent of overall beam field, and expected cold and hot regions.


Advances in Experimental Medicine and Biology | 2014

Advances in Probes and Methods for Clinical EPR Oximetry

Harold M. Swartz; Huagang Hou; Nadeem Khan; Lesley A. Jarvis; Eunice Y. Chen; Benjamin B. Williams; Periannan Kuppusamy

EPR oximetry, which enables reliable, accurate, and repeated measurements of the partial pressure of oxygen in tissues, provides a unique opportunity to investigate the role of oxygen in the pathogenesis and treatment of several diseases including cancer, stroke, and heart failure. Building on significant advances in the in vivo application of EPR oximetry for small animal models of disease, we are developing suitable probes and instrumentation required for use in human subjects. Our laboratory has established the feasibility of clinical EPR oximetry in cancer patients using India ink, the only material presently approved for clinical use. We now are developing the next generation of probes, which are both superior in terms of oxygen sensitivity and biocompatibility including an excellent safety profile for use in humans. Further advances include the development of implantable oxygen sensors linked to an external coupling loop for measurements of deep-tissue oxygenations at any depth, overcoming the current limitation of 10 mm. This paper presents an overview of recent developments in our ability to make meaningful measurements of oxygen partial pressures in human subjects under clinical settings.


Physics in Medicine and Biology | 2015

Cherenkoscopy based patient positioning validation and movement tracking during post-lumpectomy whole breast radiation therapy

Rongxiao Zhang; Jacqueline M. Andreozzi; David J. Gladstone; Whitney Hitchcock; Adam K. Glaser; Shudong Jiang; Brian W. Pogue; Lesley A. Jarvis

To investigate Cherenkov imaging (Cherenkoscopy) based patient positioning and movement tracking during external beam radiation therapy (EBRT). In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the LINAC pulse output, during different fractions of the treatment. Patients were positioned with the aid of the AlignRT system in the beginning of each treatment session. Inter-fraction setup variation was studied by rigid image registrations between images acquired at individual treatments to the average image from all imaged treatment fractions. The amplitude of respiratory motion was calculated from the registration of each frame of Cherenkov images to the reference. A Canny edge detection algorithm was utilized to highlight the beam field edges and biological features provided by major blood vessels apparent in the images. Real-time Cherenkoscopy can monitor the treatment delivery, patient motion and alignment of the beam edge to the treatment region simultaneously. For all the imaged fractions, the patient positioning discrepancies were within our clinical tolerances (3 mm in shifts and 3 degree in pitch angle rotation), with 4.6% exceeding 3 mm but still within 4 mm in shifts. The average discrepancy of repetitive patient positioning was 1.22 mm in linear shift and 0.34 degrees in rotational pitch, consistent with the accuracy reported by the AlignRT system. The edge detection algorithm enhanced features such as field edges and blood vessels. Patient positioning discrepancies and respiratory motion retrieved from rigid image registration were consistent with the edge enhanced images. Besides positioning discrepancies caused by globally inaccurate setups, edge enhanced blood vessels indicate the existence of deformations within the treatment region, especially for large patients. Real-time Cherenkoscopy imaging during EBRT is a novel imaging tool that can be used for treatment monitoring, patient positioning and motion tracking.


Medical Physics | 2016

Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

Jacqueline M. Andreozzi; Rongxiao Zhang; David J. Gladstone; Benjamin B. Williams; Adam K. Glaser; Brian W. Pogue; Lesley A. Jarvis

PURPOSE A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). METHODS Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. RESULTS As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R(2) = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R(2) = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. CONCLUSIONS Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.


Medical Physics | 2015

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Jacqueline M. Andreozzi; Rongxiao Zhang; Adam K. Glaser; Lesley A. Jarvis; Brian W. Pogue; David J. Gladstone

PURPOSE To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. METHODS Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. RESULTS Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. CONCLUSIONS The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.


Physics in Medicine and Biology | 2016

Comparison of Cherenkov excited fluorescence and phosphorescence molecular sensing from tissue with external beam irradiation.

Huiyun Lin; Rongxiao Zhang; Jason R. Gunn; Tatiana V. Esipova; Sergei A. Vinogradov; David J. Gladstone; Lesley A. Jarvis; Brian W. Pogue

Ionizing radiation delivered by a medical linear accelerator (LINAC) generates Cherenkov emission within the treated tissue. A fraction of this light, in the 600-900 nm wavelength region, propagates through centimeters of tissue and can be used to excite optical probes in vivo, enabling molecular sensing of tissue analytes. The success of isolating the emission signal from this Cherenkov excitation background is dependent on key factors such as: (i) the Stokes shift of the probe spectra; (ii) the excited state lifetime; (iii) the probe concentration; (iv) the depth below the tissue surface; and (v) the radiation dose used. Previous studies have exclusively focused on imaging phosphorescent dyes, rather than fluorescent dyes. However there are only a few biologically important phosphorescent dyes and yet in comparison there are thousands of biologically relevant fluorescent dyes. So in this study the focus was a study of efficacy of Cherenkov-excited luminescence using fluorescent commercial near-infrared probes, IRDye 680RD, IRDye 700DX, and IRDye 800CW, and comparing them to the well characterized phosphorescent probe Oxyphor PtG4, an oxygen sensitive dye. Each probe was excited by Cherenkov light from a 6 MV external radiation beam, and measured in continuous wave or time-gated modes. The detection was performed by spectrally resolving the luminescence signals, and measuring them with spectrometer-based separation on an ICCD detector. The results demonstrate that IRDye 700DX and PtG4 allowed for the maximal signal to noise ratio. In the case of the phosphorescent probe, PtG4, with emission decays on the microsecond (μs) time scale, time-gated acquisition was possible, and it allowed for higher efficacy in terms of the probe concentration and detection depth. Phantoms containing the probe at 5 mm depth could be detected at concentrations down to the nanoMolar range, and at depths into the tissue simulating phantom near 3 cm. In vivo studies showed that 5 nmol of dye was readily detected with radiation doses less than 5 cGy. Since concentration, radiation dose and depth each contribute to the level of the detected signal, it may be possible to improve any of these parameters at expense of the others. This paradigm of nanoMolar sensitivity for optical reporters in vivo introduces the concept of molecular sensing of tumors during therapy or diagnostically with biologically relevant concentrations of fluorescent reporters.

Collaboration


Dive into the Lesley A. Jarvis's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge