Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Liefke C. van der Heijden is active.

Publication


Featured researches published by Liefke C. van der Heijden.


Jacc-cardiovascular Interventions | 2015

Clinical Events and Patient-Reported Chest Pain in All-Comers Treated With Resolute Integrity and Promus Element Stents : 2-Year Follow-Up of the DUTCH PEERS (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial (TWENTE II)

Hanim Sen; Ming Kai Lam; Marije M. Löwik; Peter W. Danse; Gillian A.J. Jessurun; K. Gert van Houwelingen; Rutger L. Anthonio; R. Melvyn Tjon Joe Gin; Raymond W.M. Hautvast; J. (Hans) W. Louwerenburg; Frits H.A.F. de Man; Martin G. Stoel; Liefke C. van der Heijden; Gerard C.M. Linssen; Maarten Joost IJzerman; Kenneth Tandjung; Carine J.M. Doggen; Clemens von Birgelen

OBJECTIVES This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts). BACKGROUND For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce. METHODS The DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial [TWENTE II]) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations. RESULTS The 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel-related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 [95% confidence interval: 1.05 to 3.39], p = 0.03). CONCLUSIONS During the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.


JAMA Cardiology | 2017

Five-year outcome after implantation of zotarolimus- and everolimus-eluting stents in randomized trial participants and nonenrolled eligible patients : A secondary analysis of a randomized clinical trial

Clemens von Birgelen; Liefke C. van der Heijden; Mounir W.Z. Basalus; Marlies M. Kok; Hanim Sen; Hans W. Louwerenburg; Gert van Houwelingen; Martin G. Stoel; Frits H.A.F. de Man; Gerard C.M. Linssen; Kenneth Tandjung; Carine J.M. Doggen; Job van der Palen; Marije M. Löwik

Importance Long-term follow-up after a clinical trial of 2 often-used, newer-generation drug-eluting stents (DESs) in a broad patient population is of interest. Comprehensive long-term outcome of eligible nonenrolled patients has never been reported. Objective To assess 5-year safety and efficacy of 2 newer-generation DESs in randomized participants with non–ST-elevation acute coronary syndromes or stable angina and to evaluate long-term outcomes of nonenrolled eligible patients treated with the same DESs. Design, Setting, and Participants The TWENTE (Real-World Endeavor Resolute vs Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated, patient-blinded, randomized, comparative DES trial that enrolled patients from June 18, 2008, to August 26, 2010. Most patients had non–ST-elevation acute coronary syndromes and complex lesions. Of all 1709 eligible patients, 1391 (81.4%) were treated in the TWENTE trial with zotarolimus-eluting (ZES, n = 697) or everolimus-eluting (EES, n = 694) cobalt-chromium stents. The remaining 318 eligible patients (18.6%) were not enrolled but underwent nonrandomized treatment with the same DESs. Data were analyzed from August 26, 2015, to October 11, 2016. Event rates (percentages) were derived from log-rank analysis and may differ from straightforward calculation (nominator/denominator). The 5-year follow-up of the TWENTE participants was prespecified in the trial protocol; that of the nonenrolled participants was ad hoc. Main Outcomes and Measures Target vessel failure (TVF), a composite of cardiac death, target vessel–related myocardial infarction, or target vessel revascularization. Results Of 1709 eligible participants, 1233 (72.1%) were men, 476 (27.9%) were women, and mean (SD) age was 64.6 (10.6) years. Among the 1370 of 1391 TWENTE trial participants (98.5% follow-up), TVF was similar between those in the ZES (16.1%) and EES (18.1%) groups (P = .36). Stent thrombosis rates were low: definite (7 of 697 [1.0%] vs 4 of 694 [0.6%]; P = .37) and occurred after more than 1 year in 3 (0.4%) with ZES vs 4 (0.6%) with EES (P = .69). The 318 nonenrolled eligible patients (308 patients [96.9%] of whom were followed up) were older and had more advanced disease than trial participants. Their TVF rate was higher than that of trial participants (71 of 318 [23.3%] vs 233 of 1391 [17.1%]; P = .02), which partly reflects a difference in cardiac mortality (23 of 318 [7.7%] vs 60 of 1391 [4.5%]; P = .03). Similar 5-year rates were found for myocardial infarction (91 of 1391 [6.7%] vs 22 of 318 [7.2%]; P = .80) and target vessel revascularization (129 of 1391 [9.7%] vs 34 of 318 [11.4%]; P = .36) between trial participants and nonenrolled eligible patients. In all eligible patients (ie, trial participants plus nonenrolled eligible patients), the TVF rate was only slightly higher than in trial participants only (18.3% vs 17.1%). Conclusions and Relevance Long-term outcome data from nonenrolled eligible patients support the validity of the TWENTE trial findings and present, with the trial, a strong case for the long-term safety and efficacy of the newer-generation DESs used. Trial Registration clinicaltrials.gov Identifier: NCT01066650


International Journal of Cardiology | 2016

Safety and efficacy of everolimus-eluting bioresorbable vascular scaffolds versus durable polymer everolimus-eluting metallic stents assessed at 1-year follow-up: A systematic review and meta-analysis of studies

Bertrand Njume Mukete; Liefke C. van der Heijden; Kenneth Tandjung; Hassan Baydoun; Kapil Yadav; Qusai Saleh; Carine J.M. Doggen; Nidal Abi Rafeh; Thierry H. Le Jemtel; Clemens von Birgelen

BACKGROUND The Absorb bioresorbable vascular scaffold (BVS) was developed to address long-term safety issues of metallic drug-eluting stents. However, it may be associated with an increased event risk during the first year. METHODS A systematic literature search was performed (in MEDLINE/PubMed, Cochrane CENTRAL, EMBASE, and scientific meeting abstracts) to identify studies that compared BVS and cobalt-chromium durable polymer everolimus-eluting stents (EES). For randomized clinical trials and non-randomized propensity score matched studies that reported 1-year outcome data, fixed/random-effects models were used to generate pooled estimates of outcomes, presented as odds ratios (OR) with 95%-confidence intervals (CI). RESULTS The 1-year follow-up data of 6 trials with 5588 patients were analyzed. A device-oriented composite endpoint (DOCE - cardiac death, target vessel myocardial infarction (MI), or target lesion revascularization (TLR)) was reached by 308 BVS or EES patients (195/3253 vs. 113/2315). Meta-analysis showed that patients who received BVS had an increased risk of MI (4.3% vs. 2.3%; OR:1.63, 95%-CI: 1.18-2.25, p<0.01) and definite-or-probable scaffold thrombosis (1.3% vs. 0.6%; OR:2.10, 95%-CI: 1.13-3.87, p=0.02). However, there was no significant between-group difference in risk of DOCE (6.0% vs. 4.9%; OR:1.19, 95%-CI: 0.94-1.52, p=0.16), cardiac death (0.8% vs. 0.7%; OR:1.14, 95%-CI: 0.54-2.39, p=0.73), or TLR (2.5% vs. 2.5%; OR: 0.98, 95%-CI:0.69-1.40, p=0.92). CONCLUSIONS During the first year of follow-up, patients treated with BVS had a higher incidence of MI and scaffold thrombosis. The risk of DOCE was not significantly different. As BVS may pay off later, future robust data on long-term clinical outcome will be of paramount importance.


American Heart Journal | 2016

Impact of severe lesion calcification on clinical outcome of patients with stable angina, treated with newer generation permanent polymer-coated drug-eluting stents: A patient-level pooled analysis from TWENTE and DUTCH PEERS (TWENTE II)

Jennifer Huisman; Liefke C. van der Heijden; Marlies M. Kok; Peter W. Danse; Gillian A.J. Jessurun; Martin G. Stoel; K. Gert van Houwelingen; Marije M. Löwik; Raymond W.M. Hautvast; Maarten Joost IJzerman; Catharina Jacoba Maria Doggen; Clemens von Birgelen

BACKGROUND The outcome of percutaneous coronary intervention with newer generation permanent polymer-coated drug-eluting stents (DES) in patients with severely calcified lesions is greatly unknown. We assessed the impact of severe lesion calcification on clinical outcome in patients with stable angina who underwent percutaneous coronary intervention with newer generation DES. METHODS TWENTE and DUTCH PEERS randomized trials enrolled 1423 patients with stable angina, who were categorized into patients with versus without severe target lesion calcification. A patient-level pooled analysis assessed clinical outcome, including target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization (TVR). RESULTS Patients with severe calcification (n = 342) were older (66.6 ± 9.1 vs 64.2 ± 9.8 years, P < .001) and had more diabetes (25.7% vs 20.4%, P = .04) than other patients (n = 1081). Patients with calcified lesions had higher rates of TVF (16.4% vs 9.8%, pLogrank = .001), cardiac death (4.4% vs 1.5%, P = .03), target vessel myocardial infarction (7.6% vs 3.4%, P = .001), and definite stent thrombosis (1.8% vs 0.4%, P = .02). Multivariate analysis demonstrated that severe calcification was an independent risk factor of 2-year TVF (HR 1.42, 95% CI: 1.02-1.99, pLogrank = .04); landmark analysis showed that this was based on a difference during the first year (periprocedural: 5.8% vs. 3.1%, pLogrank = .02; first year: 7.5% vs. 3.8%, pLogrank = .007; second year: 4.1% vs. 3.3%, pLogrank = .54). CONCLUSION In patients with stable angina, severe target lesion calcification is associated with an increased risk of adverse cardiovascular events following treatment with newer generation permanent polymer-coated DES. This increase in risk is restricted to the first year of follow-up, which is an encouraging finding.


American Heart Journal | 2015

Three-year clinical outcome of patients with bifurcation treatment with second-generation Resolute and Xience V stents in the randomized TWENTE trial

Ming Kai Lam; Hanim Sen; K. Gert van Houwelingen; Marije M. Löwik; Liefke C. van der Heijden; Marlies M. Kok; Frits H.A.F. de Man; Gerard C.M. Linssen; Kenneth Tandjung; Carine J.M. Doggen; Clemens von Birgelen

BACKGROUND Only limited data from large randomized clinical trials have been published on the long-term performance of second-generation drug-eluting stents in bifurcation lesions. METHODS We investigated in patients in the randomized TWENTE trial the long-term safety and efficacy of treating bifurcation lesions with 2 widely applied second-generation drug-eluting stents, the zotarolimus-eluting Resolute stent (Medtronic Inc, Santa Rosa, CA) and the everolimus-eluting Xience V stent (Abbott Vascular, Santa Clara, CA). Three-year follow-up was available in 99.3%. Patients were categorized into treatment for ≥1 bifurcation lesion versus treatment for nonbifurcation lesions only. RESULTS Among the 1,391 patients of the TWENTE trial, 362 (26%) were treated for bifurcation lesions. At 3-year follow-up, target-vessel failure did not differ between patients treated for bifurcation versus nonbifurcation lesions (13.1% vs 12.6%; P = .84), whereas the periprocedural myocardial infarction rate was higher in patients with bifurcation lesions (6.9% vs 3.1%; P < .01). Of the 362 patients with bifurcation lesion treatment, 179 (49.4%) were treated with Resolute and 183 (50.6%) with Xience V. There was no significant difference in target-vessel failure between the Resolute and Xience V groups with bifurcation treatment (13.6% vs 12.6%; P = .78), and their incidence of definite-or-probable stent thrombosis was low and similar (1.1% vs 0.5%, respectively; P = .62). CONCLUSION Despite a significant difference in periprocedural myocardial infarction, 3-year clinical outcome after implantation of second-generation stents was favorable and similar for patients with and without bifurcation lesions. In addition, we observed no difference in long-term clinical outcome after bifurcation lesion treatment with Resolute and Xience V stents.


Eurointervention | 2017

Three-year safety and efficacy of treating all-comers with newer-generation Resolute Integrity or PROMUS Element stents in the randomised Dutch PEERS (TWENTE II) trial

Liefke C. van der Heijden; Marlies M. Kok; Marije M. Löwik; Peter W. Danse; Gillian A.J. Jessurun; Raymond W.M. Hautvast; Gert van Houwelingen; Martin G. Stoel; Marc Hartmann; Gerard C.M. Linssen; Carine J.M. Doggen; Clemens von Birgelen

AIMS The aim of this report was to assess the three-year safety and efficacy of implanting newer-generation Resolute Integrity zotarolimus-eluting stents (ZES) versus PROMUS Element everolimus-eluting stents (EES) in all-comers. METHODS AND RESULTS In the randomised, multicentre, investigator-initiated DUTCH PEERS trial, a total of 1,811 all-comers were 1:1 randomly assigned to treatment with ZES versus EES. A total of 1,293 patients (72%) were treated for complex lesions and 455 patients (25%) were treated for multiple lesions. The primary endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction or target vessel revascularisation. Adverse clinical events were independently adjudicated. Three-year follow-up data were obtained in 1,807 patients (99.8%, four withdrawals). Both the ZES and EES groups showed favourable outcomes with a similar incidence of TVF (10.7% vs. 10.3%; pLog-rank=0.77) and the individual components thereof: cardiac death (3.2% vs. 3.1%; pLog-rank=0.87), target vessel-related myocardial infarction (2.8% vs. 2.2%; pLog-rank=0.44) and target vessel revascularisation (6.0% vs. 6.2%; pLog-rank=0.87). In addition, the incidence of definite or probable stent thrombosis was similar for patients treated with ZES versus EES (1.4% vs. 1.1%; pLog-rank=0.66). CONCLUSIONS The safety and efficacy of treating all-comers with newer-generation Resolute Integrity and PROMUS Element stents was found to be extended up to three years.


Catheterization and Cardiovascular Interventions | 2018

Patient preference for radial versus femoral vascular access for elective coronary procedures: The PREVAS study

Marlies M. Kok; Marieke Geertruida Maria Weernink; Clemens von Birgelen; Anneloes Fens; Liefke C. van der Heijden; Janine Astrid van Til

To explore patient preference for vascular access site in percutaneous coronary procedures, the perceived importance of benefits and risks of transradial access (TRA) and transfemoral access (TFA) were assessed. In addition, direct preference for vascular access and preference for shared decision making (SDM) were evaluated.


Jacc-cardiovascular Interventions | 2016

Sex Difference in Chest Pain After Implantation of Newer Generation Coronary Drug-Eluting Stents: A Patient-Level Pooled Analysis From the TWENTE and DUTCH PEERS Trials

Marlies M. Kok; Liefke C. van der Heijden; Hanim Sen; Peter W. Danse; Marije M. Löwik; Rutger L. Anthonio; J. (Hans) W. Louwerenburg; Frits H.A.F. de Man; Gerard C.M. Linssen; Maarten Joost IJzerman; Catharina Jacoba Maria Doggen; Angela H.E.M. Maas; Roxana Mehran; Clemens von Birgelen

OBJECTIVES This study sought to assess sex differences in chest pain after percutaneous coronary intervention (PCI) with newer generation drug-eluting stents (DES). BACKGROUND Sex-based data on chest pain after PCI with DES are scarce. METHODS The authors performed a patient-level pooled analysis of the TWENTE and DUTCH PEERS randomized trials, in which patients were treated with newer generation permanent polymer-coated DES. At 1 and 2 years, clinical follow-up was available in 99.8% and patient-reported chest pain data in 94.1% and 93.6%, respectively. RESULTS Among all 3,202 patients, the 871 (27.2%) women were older (67.5 ± 10.2 years vs. 62.8 ± 10.6 years; p < 0.001) and had more cardiovascular risk factors: diabetes (24.2% vs. 17.8%; p < 0.001), hypertension (63.6% vs. 51.6%; p < 0.001), and positive family history (54.5% vs. 50.1%; p = 0.03). At 1- and 2-year follow-up, women reported more clinically relevant chest pain (16.3% vs. 10.5%; p < 0.001, and 17.2% vs. 11.1%; p < 0.001, respectively). Multivariate analysis demonstrated that female sex independently predicted clinically relevant chest pain at 1- and 2-year follow-up both during daily activities and at minimum physical exertion/at rest (1 year adjusted odds ratio [OR]: 1.7; 95% confidence interval [CI]: 1.2 to 2.4; p = 0.002; and adjusted OR: 1.8; 95% CI: 1.3 to 2.5; p < 0.001; 2-year adjusted OR: 1.8; 95% CI: 1.3 to 2.6; p < 0.001; and adjusted OR: 1.7; 95% CI: 1.3 to 2.3; p = 0.001). Nevertheless, the 2-year rates of death, myocardial infarction, revascularization, stent thrombosis, and various composite clinical endpoints were similar for both sexes. CONCLUSIONS Although the incidence of adverse cardiovascular events was low and similar for both sexes, women showed a statistically significantly higher prevalence of clinically relevant chest pain, which might be largely related to mechanisms other than epicardial coronary obstruction.


International Journal of Cardiology | 2018

High bleeding risk patients with acute coronary syndromes treated with contemporary drug-eluting stents and Clopidogrel or Ticagrelor: Insights from CHANGE DAPT

M.D. Paolo Zocca; Marlies M. Kok; Liefke C. van der Heijden; K. Gert van Houwelingen; Marc Hartmann; Frits H.A.F. de Man; Martin G. Stoel; J. (Hans) W. Louwerenburg; Iris L.H. Knottnerus; Gerard C.M. Linssen; Carine J.M. Doggen; Clemens von Birgelen

BACKGROUND The prospective observational CHANGE DAPT study compared clopidogrel versus ticagrelor-based dual antiplatelet (DAPT) regimens in consecutive patients with acute coronary syndrome (ACS), treated with percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES). During the ticagrelor period (TP, May 2014-August 2015) there were more major bleedings than during the clopidogrel period (CP, December 2012-April 2014). METHODS AND RESULTS To evaluate whether the excess of major bleedings during TP may be limited to high bleeding risk (HBR) patients, we performed an explorative analysis of all 2062 CHANGE DAPT participants, of whom 547(26.5%) were classified as HBR (CP, n = 245; TP, n = 302). In HBR and non-HBR patients, we assessed the impact of CP versus TP on propensity score-adjusted rates of major bleeding and a pre-defined ischemic endpoint (composite of cardiac death, myocardial infarction, or stroke) at 1-year follow-up. Among HBR patients, the rate of major bleeding was significantly higher during TP (1.7% vs. 5.0%; HRadjusted 3.70 [95% CI 1.18-11.67], p = 0.03), while there was no significant difference in the ischemic endpoint (6.6% vs. 8.0%, HRadjusted 1.23 [95% CI 0.63-2.42], p = 0.54). In non-HBR patients, the rates of major bleeding (1.1% vs. 1.7%; HRadjusted 2.13 [95% CI 0.84-5.43], p = 0.11) and the ischemic endpoint (2.8% vs. 3.4%, HRadjusted 1.38 [95% CI 0.74-2.57], p = 0.32) were similar between both periods. CONCLUSIONS Among consecutive ACS patients, the increased risk of major bleeding during ticagrelor-based DAPT was limited to HBR patients. In both HBR and non-HBR patients, ticagrelor-based DAPT did not reduce ischemic outcomes following treatment with contemporary DES implantation.


The Cardiology | 2017

Three-Year Clinical Outcome of Patients with Coronary Disease and Increased Event Risk Treated with Newer-Generation Drug-Eluting Stents: From the Randomized DUTCH PEERS Trial

Liefke C. van der Heijden; Marlies M. Kok; Marije M. Löwik; Peter W. Danse; Gillian A.J. Jessurun; Marc Hartmann; Martin G. Stoel; Gert van Houwelingen; Raymond W.M. Hautvast; Gerard C.M. Linssen; Carine J.M. Doggen; Clemens von Birgelen

Objective: Limited data is available on the long-term outcome of patients with increased cardiovascular event risk, treated with newer-generation durable polymer drug-eluting stents (DES). Methods: We therefore assessed 3-year follow-up data of high-risk versus low- to intermediate-risk patients of the randomized DUTCH PEERS trial (NCT01331707). In both risk groups we also compared patients treated with Resolute Integrity versus Promus Element DES. Patients were categorized as “high-risk” if they met ≥1 of the following criteria: (1) diabetes (17.9%); (2) previous myocardial infarction (21.9%); (3) previous coronary revascularization (25.8%); (4) chronic renal failure (3.5%); (5) left ventricular ejection fraction ≤30% (1.5%); and (6) age ≥75 years (17.3%). Results: At the 3-year follow-up, the incidence of the composite endpoint target vessel failure (TVF) (13.2 vs. 7.5%; logrank p < 0.001) and 2 of its components - cardiac death (4.7 vs. 1.5%; logrank p < 0.001) and target vessel revascularization (7.3 vs. 4.7%; logrank p = 0.03) - was higher in high-risk (n = 957) versus low- to intermediate-risk patients (n = 854). Among high-risk patients, treatment with Resolute Integrity (n = 481) and Promus Element stents (n = 476) was similarly safe and efficacious (TVF: 13.3 vs. 13.1%; logrank p = 0.95; definite-or-probable stent thrombosis: 1.7 vs. 1.7%; logrank p = 1.00). Conclusions: The newer-generation Resolute Integrity and Promus Element stents showed similar results in terms of safety and efficacy for treating high-risk patients, who had significantly higher event rates than patients with low-to-intermediate risk.

Collaboration


Dive into the Liefke C. van der Heijden's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gerard C.M. Linssen

University Medical Center Groningen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge