IEEE Transactions on Medical Imaging | 2012

Reference-Free PRFS MR-Thermometry Using Near-Harmonic 2-D Reconstruction of the Background Phase

Rares Salomir; Magalie Viallon; Antje Kickhefel; Joerg Roland; Denis R. Morel; Lorena Petrusca; Vincent Auboiroux; Thomas Goget; Sylvain Terraz; Christoph Becker; Patrick Gross

Proton resonance frequency shift (PRFS) MR thermometry (MRT) is the generally preferred method for monitoring thermal ablation, typically implemented with gradient-echo (GRE) sequences. Standard PRFS MRT is based on the subtraction of a temporal reference phase map and is, therefore, intrinsically sensitive to tissue motion (including deformation) and to external perturbation of the magnetic field. Reference-free (or reference-less) PRFS MRT has been previously described by Rieke and was based on a 2-D polynomial fit performed on phase data from outside the heated region, to estimate the background phase inside the region of interest. While their approach was undeniably a fundamental progress in terms of robustness against tissue motion and magnetic perturbations, the underlying mathematical formalism requires a thick unheated border and may be subject to numerical instabilities with high order polynomials. A novel method of reference-free PRFS MRT is described here, using a physically consistent formalism, which exploits mathematical properties of the magnetic field in a homogeneous or near-homogeneous medium.


Physics in Medicine and Biology | 2012

Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo

Vincent Auboiroux; Lorena Petrusca; Magalie Viallon; Thomas Goget; Christoph Becker; Rares Salomir

Magnetic resonance imaging (MRI) and ultrasonography have been used simultaneously in this ex vivo study for the image-guidance of high intensity focused ultrasound (HIFU) treatment in moving tissue. A ventilator-driven balloon produced periodic and non-rigid (i.e. breathing-like) motion patterns in phantoms. MR-compatible ultrasound (US) imaging enabled near real-time 2D motion tracking based on optical flow detection, while near-harmonic reference-free proton resonance frequency shift (PRFS) MR thermometry (MRT) was used to monitor the thermal buildup on line. Reference-free MRT was applied to gradient-echo echo-planar imaging phase maps acquired at the frame rate of 250 to 300 ms/slice with voxel size 1.25×1.25×5 mm(3). The MR-US simultaneous imaging was completely free of mutual interferences while minor RF interferences from the HIFU device were detected in the far field of the US images. The effective duty-cycle of the HIFU sonication was close to 100 % and no off-interval was required to temporally decouple it from the ultrasonography. The motion compensation of the HIFU sonication was achieved with an 8 Hz frame rate and sub-millimeter spatial accuracy, both for single-focus mode and for an iterated multi-foci line scan. Near harmonic reference-less PRFS MRT delivered motion-robust thermal maps perpendicular or parallel to the HIFU beam (0.7 °C precision, 0.5 °C absolute accuracy). Out-of-plane motion compensation was not addressed in this study.


Investigative Radiology | 2013

Hybrid Ultrasound/Magnetic Resonance Simultaneous Acquisition and Image Fusion for Motion Monitoring in the Upper Abdomen

Lorena Petrusca; Philippe C. Cattin; Valeria De Luca; Frank Preiswerk; Zarko Celicanin; Vincent Auboiroux; Magalie Viallon; Patrik Arnold; Francesco Santini; Sylvain Terraz; Klaus Scheffler; Christoph Becker; Rares Salomir

ObjectivesThe combination of ultrasound (US) and magnetic resonance imaging (MRI) may provide a complementary description of the investigated anatomy, together with improved guidance and assessment of image-guided therapies. The aim of the present study was to integrate a clinical setup for simultaneous US and magnetic resonance (MR) acquisition to obtain synchronized monitoring of liver motion. The feasibility of this hybrid imaging and the precision of image fusion were evaluated. Materials and MethodsUltrasound imaging was achieved using a clinical US scanner modified to be MR compatible, whereas MRI was achieved on 1.5- and 3-T clinical scanners. Multimodal registration was performed between a high-resolution T1 3-dimensional (3D) gradient echo (volume interpolated gradient echo) during breath-hold and a simultaneously acquired 2D US image, or equivalent, retrospective registration of US imaging probe in the coordinate frame of MRI. A preliminary phantom study was followed by 4 healthy volunteer acquisitions, performing simultaneous 4D MRI and 2D US harmonic imaging (Fo = 2.2 MHz) under free breathing. ResultsNo characterized radiofrequency mutual interferences were detected under the tested conditions with commonly used MR sequences in clinical routine, during simultaneous US/MRI acquisition. Accurate spatial matching between the 2D US and the corresponding MRI plane was obtained during breath-hold. In situ fused images were delivered. Our 4D MRI sequence permitted the dynamic reconstruction of the intra-abdominal motion and the calculation of high temporal resolution motion field vectors. ConclusionsThis study demonstrates that, truly, simultaneous US/MR dynamic acquisition in the abdomen is achievable using clinical instruments. A potential application is the US/MR hybrid guidance of high-intensity focused US therapy in the liver.


Magnetic Resonance in Medicine | 2012

ARFI-prepared MRgHIFU in liver: simultaneous mapping of ARFI-displacement and temperature elevation, using a fast GRE-EPI sequence

Vincent Auboiroux; Magalie Viallon; Joerg Roland; Jean-Noël Hyacinthe; Lorena Petrusca; Denis R. Morel; Thomas Goget; Sylvain Terraz; Patrick Gross; Christoph Becker; Rares Salomir

MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR‐guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting quality. The thermal effect of high intensity focused ultrasound pulses associated with ARFI measurements is recommended to be monitored on line, in particular when the beam crosses highly absorbent structures or interfaces (e.g., bones or air‐filled cavities). A dedicated MR sequence is proposed here, derived from a segmented gradient echo‐echo planar imaging kernel by adding a bipolar motion encoding gradient with interleaved alternating polarities. Temporal resolution was reduced to 2.1 s, with in‐plane spatial resolution of 1 mm. MR‐ARFI measurements were executed during controlled animal breathing, with trans‐costal successively steered foci, to investigate the spatial modulation of the focus intensity and the targeting offset. ARFI‐induced tissue displacement measurements enabled the accurate localization, in vivo, of the high intensity focused ultrasound focal point in sheep liver, with simultaneous monitoring of the temperature elevation. ARFI‐based precalibration of the focal point position was immediately followed by trans‐costal MR‐guided high intensity focused ultrasound ablation, monitored with a conventional proton resonance frequency shift MR thermometry sequence. The latter MR thermometry sequence had spatial resolution and geometrical distortion identical with the ARFI maps, hence no coregistration was required. Magn Reson Med, 2012.


Medical Image Analysis | 2014

Model-guided respiratory organ motion prediction of the liver from 2D ultrasound

Frank Preiswerk; Valeria De Luca; Patrik Arnold; Zarko Celicanin; Lorena Petrusca; Christine Tanner; Oliver Bieri; Rares Salomir; Philippe C. Cattin

With the availability of new and more accurate tumour treatment modalities such as high-intensity focused ultrasound or proton therapy, accurate target location prediction has become a key issue. Various approaches for diverse application scenarios have been proposed over the last decade. Whereas external surrogate markers such as a breathing belt work to some extent, knowledge about the internal motion of the organs inherently provides more accurate results. In this paper, we combine a population-based statistical motion model and information from 2d ultrasound sequences in order to predict the respiratory motion of the right liver lobe. For this, the motion model is fitted to a 3d exhalation breath-hold scan of the liver acquired before prediction. Anatomical landmarks tracked in the ultrasound images together with the model are then used to reconstruct the complete organ position over time. The prediction is both spatial and temporal, can be computed in real-time and is evaluated on ground truth over long time scales (5.5 min). The method is quantitatively validated on eight volunteers where the ultrasound images are synchronously acquired with 4D-MRI, which provides ground-truth motion. With an average spatial prediction accuracy of 2.4 mm, we can predict tumour locations within clinically acceptable margins.


Magnetic Resonance in Medicine | 2014

Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs

Zarko Celicanin; Auboiroux; Oliver Bieri; Lorena Petrusca; Francesco Santini; M Viallon; Klaus Scheffler; Rares Salomir

Magnetic resonance‐guided high‐intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges.


Physics in Medicine and Biology | 2011

An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy

Vincent Auboiroux; Erik Dumont; Lorena Petrusca; Magalie Viallon; Rares Salomir

A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm(-2) CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.


BioMed Research International | 2014

Respiratory-Gated MRgHIFU in Upper Abdomen Using an MR-Compatible In-Bore Digital Camera

Vincent Auboiroux; Lorena Petrusca; Magalie Viallon; Arnaud Muller; Sylvain Terraz; Romain Breguet; Xavier Montet; Christoph Becker; Rares Salomir

Objective. To demonstrate the technical feasibility and the potential interest of using a digital optical camera inside the MR magnet bore for monitoring the breathing cycle and subsequently gating the PRFS MR thermometry, MR-ARFI measurement, and MRgHIFU sonication in the upper abdomen. Materials and Methods. A digital camera was reengineered to remove its magnetic parts and was further equipped with a 7u2009m long USB cable. The system was electromagnetically shielded and operated inside the bore of a closed 3T clinical scanner. Suitable triggers were generated based on real-time motion analysis of the images produced by the camera (resolution 640 × 480 pixels, 30u2009fps). Respiratory-gated MR-ARFI prepared MRgHIFU ablation was performed in the kidney and liver of two sheep in vivo, under general anaesthesia and ventilator-driven forced breathing. Results. The optical device demonstrated very good MR compatibility. The current setup permitted the acquisition of motion artefact-free and high resolution MR 2D ARFI and multiplanar interleaved PRFS thermometry (average SNR 30 in liver and 56 in kidney). Microscopic histology indicated precise focal lesions with sharply delineated margins following the respiratory-gated HIFU sonications. Conclusion. The proof-of-concept for respiratory motion management in MRgHIFU using an in-bore digital camera has been validated in vivo.


Investigative Radiology | 2013

Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: application to intercostal ablation in liver.

Rares Salomir; Lorena Petrusca; Vincent Auboiroux; Arnaud Muller; Maria Isabel Vargas Gomez; Denis R. Morel; Thomas Goget; Romain Breguet; Sylvain Terraz; Jerry Hopple; Xavier Montet; Christoph Becker; Magalie Viallon

ObjectivesThe treatment of liver cancer is a major public health issue because the liver is a frequent site for both primary and secondary tumors. Rib heating represents a major obstacle for the application of extracorporeal focused ultrasound to liver ablation. Magnetic resonance (MR)–guided external shielding of acoustic obstacles (eg, the ribs) was investigated here to avoid unwanted prefocal energy deposition in the pathway of the focused ultrasound beam. Materials and MethodsEx vivo and in vivo (7 female sheep) experiments were performed in this study. Magnetic resonance–guided high-intensity focused ultrasound (MRgHIFU) was performed using a randomized 256-element phased-array transducer (f∼1 MHz) and a 3-T whole-body clinical MR scanner. A physical mask was inserted in the prefocal beam pathway, external to the body, to block the energy normally targeted on the ribs. The effectiveness of the reflecting material was investigated by characterizing the efficacy of high-intensity focused ultrasound beam reflection and scattering on its surface using Schlieren interferometry. Before high-intensity focused ultrasound sonication, the alignment of the protectors with the conical projections of the ribs was required and achieved in multiple steps using the embedded graphical tools of the MR scanner. Multiplanar near real-time MR thermometry (proton resonance frequency shift method) enabled the simultaneous visualization of the local temperature increase at the focal point and around the exposed ribs. The beam defocusing due to the shielding was evaluated from the MR acoustic radiation force impulse imaging data. ResultsBoth MR thermometry (performed with hard absorber positioned behind a full-aperture blocking shield) and Schlieren interferometry indicated a very good energy barrier of the shielding material. The specific temperature contrast between rib surface (spatial average) and focus, calculated at the end point of the MRgHIFU sonication, with protectors vs no protectors, indicated an important reduction of the temperature elevation at the ribs’ surface, typically by 3.3 ± 0.4 in vivo. This was translated into an exponential reduction in thermal dose by several orders of magnitude. The external shielding covering the full conical shadow of the ribs was more effective when the protectors could be placed close to the ribs’ surface and had a tendency to lose its efficiency when placed further from the ribs. Hepatic parenchyma was safely ablated in vivo using this rib-sparing strategy and single-focus independent sonications. ConclusionsA readily available, MR-compatible, effective, and cost-competitive method for rib protection in transcostal MRgHIFU was validated in this study, using specific reflective strips. The current approach permitted safe intercostal ablation of small volumes (0.7 mL) of liver parenchyma.


CardioVascular and Interventional Radiology | 2013

Management of Respiratory Motion in Extracorporeal High-Intensity Focused Ultrasound Treatment in Upper Abdominal Organs: Current Status and Perspectives

Arnaud Muller; Lorena Petrusca; Vincent Auboiroux; Pierre-Jean Valette; Rares Salomir; François Cotton

Extracorporeal high-intensity focused ultrasound (HIFU) is a minimally invasive therapy considered with increased interest for the ablation of small tumors in deeply located organs while sparing surrounding critical tissues. A multitude of preclinical and clinical studies have showed the feasibility of the method; however, concurrently they showed several obstacles, among which the management of respiratory motion of abdominal organs is at the forefront. The aim of this review is to describe the different methods that have been proposed for managing respiratory motion and to identify their advantages and weaknesses. First, we specify the characteristics of respiratory motion for the liver, kidneys, and pancreas and the problems it causes during HIFU planning, treatment, and monitoring. Second, we make an inventory of the preclinical and clinical approaches used to overcome the problem of organ motion. Third, we analyze their respective benefits and drawbacks to identify the remaining physical, technological, and clinical challenges. We thereby consider the outlook of motion compensation techniques and those that would be the most suitable for clinical use, particularly under magnetic resonance thermometry monitoring.

Collaboration


Dive into the Lorena Petrusca's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge