Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lynne M. Sloan is active.

Publication


Featured researches published by Lynne M. Sloan.


Clinical Microbiology Reviews | 2006

Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

Mark J. Espy; J. R. Uhl; Lynne M. Sloan; Seanne P. Buckwalter; Mary F. Jones; Emily A. Vetter; J. D. C. Yao; Nancy L. Wengenack; Jon E. Rosenblatt; Franklin R. Cockerill; Thomas F. Smith

SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.


Journal of Clinical Microbiology | 2008

Comparison of Real-Time PCR for Detection of the tcdC Gene with Four Toxin Immunoassays and Culture in Diagnosis of Clostridium difficile Infection

Lynne M. Sloan; Brian J. Duresko; Daniel R. Gustafson; Jon E. Rosenblatt

ABSTRACT We have developed a rapid real-time PCR method using fluorescence resonance energy transfer probes and the LightCycler (Roche Diagnostics), which will detect the presence of the tcdC gene of Clostridium difficile in stool samples. Our PCR method also will identify the presence of base pair deletions, one of which (18 bp) has been associated with the “epidemic” toxin-hyperproducing strains. We compared the results of this PCR with those of three C. difficile toxin-detecting enzyme immunoassays (EIAs), an EIA for the detection of glutamate dehydrogenase (GDH), and culture of C. difficile. A total of 200 stool specimens were studied by the methods under comparison. C. difficile was isolated from 49 specimens by culture, and 44 of these were confirmed as containing one of the genes associated with toxin production (“toxigenic culture”). Using toxigenic culture as the “gold standard”, the sensitivities, specificities, and positive and negative predictive values, respectively, of the assays were 48%, 98%, 88%, and 87% for the Premier toxin A and B test; 48%, 99%, 91%, and 87% for the ImmunoCard toxin A & B test; 48%, 84%, 46%, and 85% for the Xpect C. difficile toxin A/B test; 32%, 100%, 100%, and 84% for the Triage C. difficile panel (for toxin A); and 86%, 97%, 90%, and 96% for the LightCycler PCR. Thus, in comparison to the sensitivity of toxigenic culture, the sensitivities of the toxin immunoassays were unacceptably low, while the LightCycler real-time PCR assay for the detection of the tcdC gene of C. difficile is sensitive and specific.


The New England Journal of Medicine | 2011

Emergence of a New Pathogenic Ehrlichia Species, Wisconsin and Minnesota, 2009

Bobbi S. Pritt; Lynne M. Sloan; Diep K. Hoang Johnson; Ulrike G. Munderloh; Susan M. Paskewitz; Kristina M. McElroy; Jevon McFadden; Matthew J. Binnicker; David F. Neitzel; Gongping Liu; William L. Nicholson; Curtis M. Nelson; Joni J. Franson; Scott A. Martin; Scott A. Cunningham; Christopher R. Steward; Kay Bogumill; Mary E. Bjorgaard; Jeffrey P. Davis; Jennifer H. McQuiston; David M. Warshauer; Mark P. Wilhelm; Robin Patel; Vipul A. Trivedi; Marina E. Eremeeva

BACKGROUND Ehrlichiosis is a clinically important, emerging zoonosis. Only Ehrlichia chaffeensis and E. ewingii have been thought to cause ehrlichiosis in humans in the United States. Patients with suspected ehrlichiosis routinely undergo testing to ensure proper diagnosis and to ascertain the cause. METHODS We used molecular methods, culturing, and serologic testing to diagnose and ascertain the cause of cases of ehrlichiosis. RESULTS On testing, four cases of ehrlichiosis in Minnesota or Wisconsin were found not to be from E. chaffeensis or E. ewingii and instead to be caused by a newly discovered ehrlichia species. All patients had fever, malaise, headache, and lymphopenia; three had thrombocytopenia; and two had elevated liver-enzyme levels. All recovered after receiving doxycycline treatment. At least 17 of 697 Ixodes scapularis ticks collected in Minnesota or Wisconsin were positive for the same ehrlichia species on polymerase-chain-reaction testing. Genetic analyses revealed that this new ehrlichia species is closely related to E. muris. CONCLUSIONS We report a new ehrlichia species in Minnesota and Wisconsin and provide supportive clinical, epidemiologic, culture, DNA-sequence, and vector data. Physicians need to be aware of this newly discovered close relative of E. muris to ensure appropriate testing, treatment, and regional surveillance. (Funded by the National Institutes of Health and the Centers for Disease Control and Prevention.).


Journal of Clinical Microbiology | 2014

Comparative Evaluation of Two Commercial Multiplex Panels for Detection of Gastrointestinal Pathogens by Use of Clinical Stool Specimens

Reeti Khare; Mark J. Espy; Elizabeth Cebelinski; David Boxrud; Lynne M. Sloan; Scott A. Cunningham; Bobbi S. Pritt; Robin Patel; Matthew J. Binnicker

ABSTRACT The detection of pathogens associated with gastrointestinal disease may be important in certain patient populations, such as immunocompromised hosts, the critically ill, or individuals with prolonged disease that is refractory to treatment. In this study, we evaluated two commercially available multiplex panels (the FilmArray gastrointestinal [GI] panel [BioFire Diagnostics, Salt Lake City, UT] and the Luminex xTag gastrointestinal pathogen panel [GPP] [Luminex Corporation, Toronto, Canada]) using Cary-Blair stool samples (n = 500) submitted to our laboratory for routine GI testing (e.g., culture, antigen testing, microscopy, and individual real-time PCR). At the time of this study, the prototype (non-FDA-cleared) FilmArray GI panel targeted 23 pathogens (14 bacterial, 5 viral, and 4 parasitic), and testing of 200 μl of Cary-Blair stool was recommended. In contrast, the Luminex GPP assay was FDA cleared for the detection of 11 pathogens (7 bacterial, 2 viral, and 2 parasitic), but had the capacity to identify 4 additional pathogens using a research-use-only protocol. Importantly, the Luminex assay was FDA cleared for 100 μl raw stool; however, 100 μl Cary-Blair stool was tested by the Luminex assay in this study. Among 230 prospectively collected samples, routine testing was positive for one or more GI pathogens in 19 (8.3%) samples, compared to 76 (33.0%) by the FilmArray and 69 (30.3%) by the Luminex assay. Clostridium difficile (12.6 to 13.9% prevalence) and norovirus genogroup I (GI)/GII (5.7 to 13.9% prevalence) were two of the pathogens most commonly detected by both assays among prospective samples. Sapovirus was also commonly detected (5.7% positive rate) by the FilmArray assay. Among 270 additional previously characterized samples, both multiplex panels demonstrated high sensitivity (>90%) for the majority of targets, with the exception of several pathogens, notably Aeromonas sp. (23.8%) by FilmArray and Yersinia enterocolitica (48.1%) by the Luminex assay. Interestingly, the FilmArray and Luminex panels identified mixed infections in 21.1% and 13.0% of positive prospective samples, respectively, compared to only 8.3% by routine methods.


Lancet Infectious Diseases | 2016

Identification of a novel pathogenic Borrelia species causing Lyme borreliosis with unusually high spirochaetaemia: a descriptive study

Bobbi S. Pritt; Paul S. Mead; Diep K. Hoang Johnson; David F. Neitzel; Laurel B. Respicio-Kingry; Jeffrey P. Davis; Elizabeth Schiffman; Lynne M. Sloan; Martin E. Schriefer; Adam J. Replogle; Susan M. Paskewitz; Julie Ray; Jenna Bjork; Christopher R. Steward; Alecia Deedon; Xia Lee; Luke C. Kingry; Tracy K. Miller; Michelle A. Feist; Elitza S. Theel; Robin Patel; Cole L. Irish; Jeannine M. Petersen

BACKGROUND Lyme borreliosis is the most common tick-borne disease in the northern hemisphere. It is a multisystem disease caused by Borrelia burgdorferi sensu lato genospecies and characterised by tissue localisation and low spirochaetaemia. In this study we aimed to describe a novel Borrelia species causing Lyme borreliosis in the USA. METHODS At the Mayo clinic, from 2003 to 2014, we tested routine clinical diagnostic specimens from patients in the USA with PCR targeting the oppA1 gene of B burgdorferi sensu lato. We identified positive specimens with an atypical PCR result (melting temperature outside of the expected range) by sequencing, microscopy, or culture. We collected Ixodes scapularis ticks from regions of suspected patient tick exposure and tested them by oppA1 PCR. FINDINGS 100 545 specimens were submitted by physicians for routine PCR from Jan 1, 2003 to Sept 30, 2014. From these samples, six clinical specimens (five blood, one synovial fluid) yielded an atypical oppA1 PCR product, but no atypical results were detected before 2012. Five of the six patients with atypical PCR results had presented with fever, four had diffuse or focal rash, three had symptoms suggestive of neurological inclusion, and two were admitted to hospital. The sixth patient presented with knee pain and swelling. Motile spirochaetes were seen in blood samples from one patient and cultured from blood samples from two patients. Among the five blood specimens, the median oppA1 copy number was 180 times higher than that in 13 specimens that tested positive for B burgdorferi sensu stricto during the same time period. Multigene sequencing identified the spirochaete as a novel B burgdorferi sensu lato genospecies. This same genospecies was detected in ticks collected at a probable patient exposure site. INTERPRETATION We describe a new pathogenic Borrelia burgdorferi sensu lato genospecies (candidatus Borrelia mayonii) in the upper midwestern USA, which causes Lyme borreliosis with unusually high spirochaetaemia. Clinicians should be aware of this new B burgdorferi sensu lato genospecies, its distinct clinical features, and the usefulness of oppA1 PCR for diagnosis. FUNDING US Centers for Disease Control and Prevention Epidemiology and Laboratory Capacity for Infectious Diseases (ELC) Cooperative Agreement and Mayo Clinic Small Grant programme.


Journal of Clinical Microbiology | 2010

Three-Hour Molecular Detection of Campylobacter, Salmonella, Yersinia, and Shigella Species in Feces with Accuracy as High as That of Culture

Scott A. Cunningham; Lynne M. Sloan; Lisa M. Nyre; Emily A. Vetter; Jayawant N. Mandrekar; Robin Patel

ABSTRACT Campylobacter jejuni and Salmonella, Shigella, and Yersinia species (along with Shiga toxin-producing Escherichia coli) are the most common causes of acute bacterial diarrheal disease in the United States. Current detection techniques are time-consuming, limiting usefulness for patient care. We developed and validated a panel of rapid PCR assays for the detection and identification of C. jejuni, C. coli, Salmonella, and Yersinia species and Shigella and enteroinvasive E. coli in stool samples. A total of 392 archived stool specimens, previously cultured for enteric pathogens, were evaluated by PCR. Overall, 104 stool specimens had been culture positive (C. jejuni/coli [n = 51], Salmonella species [n = 42], Shigella species [n = 6], and Yersinia species [n = 5]). Compared to culture, the overall sensitivity and specificity of PCR detection of these organisms were 92 and 98% (96/104 and 283/288), respectively, from fresh or Cary Blair stool (P = 0.41); 87 and 98% (41/47 and 242/246), respectively, from fresh stool (P = 0.53); and 96 and 98% (55/57 and 41/42), respectively, from Cary Blair stool (P = 0.56). For individual genera, PCR was as sensitive as the culture method, with the exception of Salmonella culture using selenite enrichment for which PCR was less sensitive than culture from fresh, but not Cary Blair (P = 0.03 and 1.00, respectively) stools. This PCR assay panel for the rapid diagnosis of acute infectious bacterial diarrheal pathogens has a sensitivity and specificity equivalent to that of culture for stools in Cary Blair transport medium. Paired with reflexive culture of stools testing positive, this should provide an improvement in care for patients with acute infectious diarrheal disease.


Journal of Clinical Microbiology | 2002

Multiplex LightCycler PCR Assay for Detection and Differentiation of Bordetella pertussis and Bordetella parapertussis in Nasopharyngeal Specimens

Lynne M. Sloan; Marlene K. Hopkins; P. S. Mitchell; Emily A. Vetter; Jon E. Rosenblatt; William S. Harmsen; Franklin R. Cockerill; Robin Patel

ABSTRACT A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS481 and IS1001 of B. pertussis and B. parapertussis, respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensitivity is less than one organism per reaction. Results for Bordetella culture and/or direct fluorescent antibody testing and a second LightCycler PCR assay (target, pertussis toxin gene) were compared to results of the LC-PCR-IS assay for 111 nasopharyngeal swabs submitted for pertussis testing. Of the specimens, 12 were positive (9 B. pertussis and 3 B. parapertussis) and 68 specimens were negative by all methods. Three other specimens were positive for B. pertussis by at least two of the methods (including the LC-PCR-IS assay), and another 28 specimens were positive for B. pertussis by the LC-PCR-IS assay only. No specimens were negative by the LC-PCR-IS assay and positive by the other methods. A conventional PCR method (target, IS481) was also compared to the LC-PCR-IS assay for a different group of nasopharyngeal swab specimens (n = 96): 44 specimens were positive and 41 specimens were negative for B. pertussis with both PCR methods. Nine specimens were positive for B. pertussis by the LC-PCR-IS assay and negative by the conventional PCR assay, and two specimens were positive for B. pertussis by the conventional PCR assay and negative by the LC-PCR-IS assay. Positivity of the two assays was not significantly different (P = 0.0654). The insertion sequence IS481 is also present in Bordetella holmesii; specimens containing B. holmesii may yield false-positive results. The LC-PCR-IS assay takes approximately 45 min to complete post-nucleic acid extraction, compared to 24 h for the conventional PCR assay previously used in our laboratory. The LC-PCR-IS assay is easier to perform than the conventional PCR assay, and the closed system decreases the chance of contamination. All of these characteristics represent a significant improvement in the detection of B. pertussis and B. parapertussis in nasopharyngeal specimens.


Journal of Clinical Microbiology | 2002

Real-Time PCR Method for Detection of Encephalitozoon intestinalis from Stool Specimens

D. M. Wolk; Susan K. Schneider; Nancy L. Wengenack; Lynne M. Sloan; Jon E. Rosenblatt

ABSTRACT The prevalence of microsporidiosis is likely underestimated due to the labor-intensive, insensitive, and nonspecific clinical laboratory methods used for the diagnosis of this disease. A real-time PCR assay was designed to assess DNA extraction methods and to detect three Encephalitozoon species in feces. Modifications of the MagNA Pure LC DNA isolation kit protocol (Roche Applied Sciences, Indianapolis, Ind.) were compared by using the automated MagNA Pure LC instrument (Roche) and fecal specimens spiked with Encephalitozoonintestinalis spores. Extracted DNA was amplified by the LightCycler (Roche) PCR assay. Assay sensitivity, reproducibility, and efficiency were assessed by comparing threshold crossover values achieved with different extraction and storage conditions (fresh, refrigerated, frozen, and preserved specimens). Optimal extraction conditions were achieved by using a commercial buffer, tissue lysis buffer (Roche), as the specimen diluent. LightCycler PCR results were compared to those obtained from routine stool microscopy with trichrome blue stain. The lower limit of detection for the LightCycler PCR assay varied by storage conditions from 102 to 104 spores/ml of feces, a value which represented a significant improvement over that achieved by staining (≥1.0 × 106 spores/ml). Melting temperature analysis of the amplicons allowed for the differentiation of three Encephalitozoon species (E. intestinalis, E. cuniculi, and E. hellem). The assay is readily adaptable to the clinical laboratory and represents the first real-time PCR assay designed to detect Encephalitozoon species.


Journal of Clinical Microbiology | 2001

Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods

Mark J. Espy; Paul N. Rys; Arlo D. Wold; James R. Uhl; Lynne M. Sloan; Greg D. Jenkins; Duane M. Ilstrup; Frank R. Cockerill; Robin Patel; Jon E. Rosenblatt; Thomas F. Smith

ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method (P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles (P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) (P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.


Journal of Clinical Microbiology | 2004

Comparison of the Roche LightCycler vanA/vanB Detection Assay and Culture for Detection of Vancomycin-Resistant Enterococci from Perianal Swabs

Lynne M. Sloan; J. R. Uhl; Emily A. Vetter; Cathy D. Schleck; William S. Harmsen; J. Manahan; Rodney L. Thompson; Jon E. Rosenblatt; Franklin R. Cockerill

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA/vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml (n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml (n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.

Collaboration


Dive into the Lynne M. Sloan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Susan M. Paskewitz

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jeffrey P. Davis

University of Wisconsin-Madison

View shared research outputs
Researchain Logo
Decentralizing Knowledge