Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Carpinelli is active.

Publication


Featured researches published by M. Carpinelli.


Medical Physics | 2009

A novel multithreshold method for nodule detection in lung CT

Bruno Golosio; Giovanni Luca Christian Masala; Alessio Piccioli; P. Oliva; M. Carpinelli; Rosella Cataldo; P. Cerello; Francesco De Carlo; Fabio Falaschi; Maria Evelina Fantacci; Gianfranco Gargano; Parnian Kasae; M. Torsello

Multislice computed tomography (MSCT) is a valuable tool for lung cancer detection, thanks to its ability to identify noncalcified nodules of small size (from about 3 mm). Due to the large number of images generated by MSCT, there is much interest in developing computer-aided detection (CAD) systems that could assist radiologists in the lung nodule detection task. A complete multistage CAD system, including lung boundary segmentation, regions of interest (ROIs) selection, feature extraction, and false positive reduction is presented. The selection of ROIs is based on a multithreshold surface-triangulation approach. Surface triangulation is performed at different threshold values, varying from a minimum to a maximum value in a wide range. At a given threshold value, a ROI is defined as the volume inside a connected component of the triangulated isosurface. The evolution of a ROI as a function of the threshold can be represented by a treelike structure. A multithreshold ROI is defined as a path on this tree, which starts from a terminal ROI and ends on the root ROI. For each ROI, the volume, surface area, roundness, density, and moments of inertia are computed as functions of the threshold and used as input to a classification system based on artificial neural networks. The method is suitable to detect different types of nodules, including juxta-pleural nodules and nodules connected to blood vessels. A training set of 109 low-dose MSCT scans made available by the Pisa center of the Italung-CT trial and annotated by expert radiologists was used for the algorithm design and optimization. The system performance was tested on an independent set of 23 low-dose MSCT scans coming from the Pisa Italung-CT center and on 83 scans made available by the Lung Image Database Consortium (LIDC) annotated by four expert radiologists. On the Italung-CT test set, for nodules having a diameter greater than or equal to 3 mm, the system achieved 84% and 71% sensitivity at false positive/scan rates of 10 and 4, respectively. For nodules having a diameter greater than or equal to 4 mm, the sensitivities were 97% and 80% at false positive/scan rates of 10 and 4, respectively. On the LIDC data set, the system achieved a 79% sensitivity at a false positive/scan rate of 4 in the detection of nodules with a diameter greater than or equal to 3 mm that have been annotated by all four radiologists.


Applied Physics Letters | 2010

Quantitative evaluation of single-shot inline phase contrast imaging using an inverse compton x-ray source

P. Oliva; M. Carpinelli; Bruno Golosio; Pasquale Delogu; Marco Endrizzi; Jangho Park; Igor Pogorelsky; V. Yakimenko; O. Williams; J. B. Rosenzweig

Inverse compton scattering (ICS) x-ray sources are of current interest in biomedical imaging. We present an experimental demonstration of inline phase contrast imaging using a single picosecond pulse of the ICS source located at the BNL Accelerator Test Facility. The phase contrast effect is clearly observed. Its qualities are shown to be in agreement with the predictions of theoretical models through comparison of experimental and simulated images of a set of plastic wires of differing composition and size. Finally, we display an application of the technique to a biological sample, confirming the possibility of time-resolved imaging on the picosecond scale.


Journal of Applied Physics | 2008

Phase contrast imaging simulation and measurements using polychromatic sources with small source-object distances

Bruno Golosio; Pasquale Delogu; Irene Zanette; M. Carpinelli; Giovanni Luca Christian Masala; P. Oliva; A. Stefanini; S. Stumbo

Phase contrast imaging is a technique widely used in synchrotron facilities for nondestructive analysis. Such technique can also be implemented through microfocus x-ray tube systems. Recently, a relatively new type of compact, quasimonochromatic x-ray sources based on Compton backscattering has been proposed for phase contrast imaging applications. In order to plan a phase contrast imaging system setup, to evaluate the system performance and to choose the experimental parameters that optimize the image quality, it is important to have reliable software for phase contrast imaging simulation. Several software tools have been developed and tested against experimental measurements at synchrotron facilities devoted to phase contrast imaging. However, many approximations that are valid in such conditions (e.g., large source-object distance, small transverse size of the object, plane wave approximation, monochromatic beam, and Gaussian-shaped source focal spot) are not generally suitable for x-ray tubes and othe...


Applied Physics Letters | 2012

Measurement of an inverse Compton scattering source local spectrum using k-edge filters

Bruno Golosio; Marco Endrizzi; P. Oliva; Pasquale Delogu; M. Carpinelli; Igor Pogorelsky; V. Yakimenko

X-ray sources based on the inverse Compton scattering process are attracting a growing interest among scientists, due to their extremely fast pulse, quasi-monochromatic spectrum, and relatively high intensity. The energy spectrum of the x-ray beam produced by inverse Compton scattering sources in a fixed observation direction is a quasi-monochromatic approximately Gaussian distribution. The mean value of this distribution varies with the scattering polar angle between the electron beam direction and the x-ray beam observation direction. Previous works reported experimental measurements of the mean energy as a function of the polar angle. This work introduces a method for the measurement of the whole local energy spectrum (i.e., the spectrum in a fixed observation direction) of the x-ray beam yielded by inverse Compton scattering sources, based on a k-edge filtering technique.


Journal of Instrumentation | 2013

A proton Computed Tomography system for medical applications

V. Sipala; M. Bruzzi; M. Bucciolini; M. Carpinelli; G.A.P. Cirrone; C. Civinini; G. Cuttone; D. Lo Presti; S. Pallotta; C. Pugliatti; N. Randazzo; F. Romano; M. Scaringella; C. Stancampiano; C. Talamonti; M. Tesi; Eleonora Vanzi; M. Zani

Proton Computed Tomography (pCT) can improve the accuracy of both patient positioning and dose calculation in proton therapy, enabling to accurately reconstruct the electron density distribution of irradiated tissues. A pCT prototype, equipped with a silicon tracker and a YAG:Ce calorimeter, has been manufactured by an Italian collaboration. First tests under proton beam allowed obtaining good quality tomographic images of a non-homogeneous phantom. Manufacturing of a new large area system with real-time data acquisition is under way.


Journal of Instrumentation | 2014

A proton Computed Tomography based medical imaging system

M. Scaringella; M. Bruzzi; M. Bucciolini; M. Carpinelli; G.A.P. Cirrone; C. Civinini; G. Cuttone; D. Lo Presti; S. Pallotta; C. Pugliatti; N. Randazzo; F. Romano; V. Sipala; C. Stancampiano; C. Talamonti; Eleonora Vanzi; M. Zani

This paper reports on the activity of the INFN PRIMA/RDH collaboration in the development of proton Computed Tomography (pCT) systems based on single proton tracking and residual energy measurement. The systems are made of a silicon microstrip tracker and a YAG:Ce crystal calorimeter to measure single protons trajectory and residual energy, respectively. A first prototype of pCT scanner, with an active area of about 5 × 5 cm2 and a data rate capability of 10 kHz, has been constructed and characterized with 62 MeV protons at INFN Laboratori Nazionali del Sud in Catania (Italy) and with 180 MeV protons at The Svedberg Laboratory (TSL) in Uppsala (Sweden). Results of these measurements, including tomographic reconstructions of test phantoms, will be shown and discussed. An upgraded system with an extended field of view (up to ~ 5 × 20 cm2) and an increased event rate capability up to one MHz, presently under development, will be also described.


Journal of Instrumentation | 2012

Performance of upstream interaction region detectors for the FIRST experiment at GSI

Z. Abou-Haidar; C. Agodi; M. A. G. Alvarez; M. Anelli; T. Aumann; G. Battistoni; A. Bocci; T.T. Böhlen; A. Boudard; Antonio Brunetti; M. Carpinelli; G.A.P. Cirrone; M. A. Cortés-Giraldo; G. Cuttone; M. De Napoli; M. Durante; J.P. Fernández-García; Ch. Finck; M.I. Gallardo; Bruno Golosio; E. Iarocci; Felice Iazzi; G. Ickert; R. Introzzi; D. Juliani; J. Krimmer; N. Kurz; M. Labalme; Y. Leifels; A. Le Fèvre

The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at GSI has been designed to study carbon fragmentation, measuring 12C double differential cross sections (∂2σ/∂θ∂E) for different beam energies between 100 and 1000 MeV/u. The experimental setup integrates newly designed detectors in the, so called, Interaction Region around the graphite target. The Interaction Region upstream detectors are a 250 μm thick scintillator and a drift chamber optimized for a precise measurement of the ions interaction time and position on the target. In this article we review the design of the upstream detectors along with the preliminary results of the data taking performed on August 2011 with 400 MeV/u fully stripped carbon ion beam at GSI. Detectors performances will be reviewed and compared to those obtained during preliminary tests, performed with 500 MeV electrons (at the BTF facility in the INFN Frascati Laboratories) and 80 MeV/u protons and carbon ions (at the INFN LNS Laboratories in Catania).


Journal of Physics: Conference Series | 2014

ELIMED, MEDical and multidisciplinary applications at ELI-Beamlines

F. Schillaci; Antonello Anzalone; G.A.P. Cirrone; M. Carpinelli; G. Cuttone; Mariapompea Cutroneo; C. De Martinis; D. Giove; G. Korn; M. Maggiore; Lorenzo Manti; D. Margarone; Agatino Musumarra; F Perozziello; Ivan Petrović; P. Pisciotta; Marcella Renis; Aleksandra Ristić-Fira; F. Romano; Giuseppe Schettino; V. Scuderi; L. Torrisi; A. Tramontana; S. Tudisco

ELI-Beamlines is one of the pillars of the pan-European project ELI (Extreme Light Infrastructure). It will be an ultra high-intensity, high repetition-rate, femtosecond laser facility whose main goal is generation and applications of high-brightness X-ray sources and accelerated charged particles in different fields. Particular care will be devoted to the potential applicability of laser-driven ion beams for medical treatments of tumors. Indeed, such kind of beams show very interesting peculiarities and, moreover, laser-driven based accelerators can really represent a competitive alternative to conventional machines since they are expected to be more compact in size and less expensive. The ELIMED project was launched thanks to a collaboration established between FZU-ASCR (ELI-Beamlines) and INFN-LNS researchers. Several European institutes have already shown a great interest in the project aiming to explore the possibility to use laser-driven ion (mostly proton) beams for several applications with a particular regard for medical ones. To reach the project goal several tasks need to be fulfilled, starting from the optimization of laser-target interaction to dosimetric studies at the irradiation point at the end of a proper designed transport beam-line. Researchers from LNS have already developed and successfully tested a high-dispersive power Thomson Parabola Spectrometer, which is the first prototype of a more performing device to be used within the ELIMED project. Also a Magnetic Selection System able to produce a small pencil beam out of a wide energy distribution of ions produced in laser-target interaction has been realized and some preliminary work for its testing and characterization is in progress. In this contribution the status of the project will be reported together with a short description of the of the features of device recently developed.


Optics Express | 2011

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Marco Endrizzi; Timur E. Gureyev; Pasquale Delogu; P. Oliva; Bruno Golosio; M. Carpinelli; Igor Pogorelsky; V. Yakimenko; U. Bottigli

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.


11th International Conference on Nucleus-Nucleus Collisions (NN2012) | 2013

FIRST experiment: Fragmentation of Ions Relevant for Space and Therapy

C. Agodi; Z. Abou-Haidar; M. A. G. Alvarez; T. Aumann; F. Balestra; G. Battistoni; A. Bocci; T.T. Böhlen; M Bondì; A. Boudard; A. Brunetti; M. Carpinelli; F Cappuzzello; M Cavallaro; D Carbone; G.A.P. Cirrone; M. A. Cortés-Giraldo; G. Cuttone; M. De Napoli; Marco Durante; J.P. Fernández-García; C Finck; A Foti; M.I. Gallardo; Bruno Golosio; E. Iarocci; Felice Iazzi; G. Ickert; R. Introzzi; D. Juliani

Nuclear fragmentation processes are relevant in different fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at SIS accelerator of GSI laboratory in Darmstadt, has been designed for the measurement of different ions fragmentation cross sections at different energies between 100 and 1000 MeV/nucleon. The experiment is performed by an international collaboration made of institutions from Germany, France, Italy and Spain. The experimental apparatus is partly based on an already existing setup made of the ALADIN magnet, the MUSIC IV TPC, the LAND2 neutron detector and the TOFWALL scintillator TOF system, integrated with newly designed detectors in the interaction Region (IR) around the carbon removable target: a scintillator Start Counter, a Beam Monitor drift chamber, a silicon Vertex Detector and a Proton Tagger for detection of light fragments emitted at large angles (KENTROS). The scientific program of the FIRST experiment started on summer 2011 with the study of the 400 MeV/nucleon 12C beam fragmentation on thin (8mm) carbon target.

Collaboration


Dive into the M. Carpinelli's collaboration.

Top Co-Authors

Avatar

G. Cuttone

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar

G.A.P. Cirrone

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P. Oliva

University of Sassari

View shared research outputs
Top Co-Authors

Avatar

V. Sipala

University of Sassari

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. Bruzzi

University of Florence

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge