Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Palka is active.

Publication


Featured researches published by M. Palka.


Physics Letters B | 2010

Origin of the low-mass electron pair excess in light nucleus-nucleus collisions

G. Agakichiev; A. Balanda; D. Belver; A.V. Belyaev; A. Blanco; M. Böhmer; J. L. Boyard; P. Braun-Munzinger; P. Cabanelas; E. Castro; S. Chernenko; T. Christ; M. Destefanis; J. Diaz; F. Dohrmann; A. Dybczak; L. Fabbietti; O. Fateev; P. Finocchiaro; P. Fonte; J. Friese; I. Fröhlich; T. Galatyuk; J. A. Garzón; R. Gernhäuser; A. Gil; C. Gilardi; K. Göbel; M. Golubeva; D. González-Díaz

Abstract We report measurements of electron pair production in elementary p + p and d + p reactions at 1.25 GeV / u with the HADES spectrometer. For the first time, the electron pairs were reconstructed for n + p reactions by detecting the proton spectator from the deuteron breakup. We find that the yield of electron pairs with invariant mass M e + e − > 0.15 GeV / c 2 is about an order of magnitude larger in n + p reactions as compared to p + p . A comparison to model calculations demonstrates that the production mechanism is not sufficiently described yet. The electron pair spectra measured in C + C reactions are compatible with a superposition of elementary n + p and p + p collisions, leaving little room for additional electron pair sources in such light collision systems.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2015

A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals

P. Moskal; Natalia Zoń; T. Bednarski; P. Białas; E. Czerwiński; A. Gajos; D. Kamińska; Ł. Kapłon; Andrzej Kochanowski; G. Korcyl; Jakub Kowal; P. Kowalski; T. Kozik; W. Krzemien; E. Kubicz; Sz. Niedźwiecki; M. Palka; L. Raczyński; Z. Rudy; Oleksandr Rundel; P. Salabura; Neha Sharma; M. Silarski; A. Słomski; J. Smyrski; A. Strzelecki; A. Wieczorek; W. Wiślicki; M. Zieliński

A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar to the measurement signal. The time of the interaction is determined as a relative time between the measured signal and the most similar one in the library. A degree of similarity of measured and model signals is defined as the distance between points representing the measurement- and model-signal in the multidimensional measurement space. Novelty of the method lies also in the proposed way of synchronization of model signals enabling direct determination of the difference between time-of-flights (TOF) of annihilation quanta from the annihilation point to the detectors. The introduced method was validated using experimental data obtained by means of the double strip prototype of the J-PET detector and 22 Na


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014

Test of a single module of the J-PET scanner based on plastic scintillators

P. Moskal; Sz. Niedźwiecki; T. Bednarski; E. Czerwiński; Ł. Kapłon; E. Kubicz; Ines Moskal; M. Pawlik-Niedźwiecka; Neha Sharma; M. Silarski; M. Zieliński; Natalia Zoń; P. Białas; A. Gajos; Andrzej Kochanowski; G. Korcyl; Jakub Kowal; P. Kowalski; T. Kozik; W. Krzemien; Marcin Molenda; M. Palka; L. Raczyński; Z. Rudy; P. Salabura; A. Słomski; J. Smyrski; A. Strzelecki; A. Wieczorek; W. Wiślicki

A Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this paper we report on tests of a single detection module built out from the BC-420 plastic scintillator strip (with dimensions of 5 � 19 � 300 mm 3 ) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68 Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50 ps intervals. The time resolution of the prototype module was established to be better than 80 ps (σ) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93 cm (σ) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to σðEÞ=E � 0:044= ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi EðMeVÞ p


Physical Review C | 2011

Dielectron production in Ar+KCl collisions at 1.76A GeV

G. Agakishiev; A. Balanda; D. Belver; Alexander Belyaev; A. Blanco; J.L. Boyard; P. Cabanelas; E. Castro; S. Chernenko; T. Christ; M. Destefanis; F. Dohrmann; A. Dybczak; T. Eberl; E. Epple; L. Fabbietti; O. Fateev; P. Finocchiaro; P. Fonte; J. Friese; T. Galatyuk; C. Gilardi; M. Golubeva; F. Guber; M. Gumberidze; T. Heinz; T. Hennino; R. Holzmann; P. Huck; I. Iori

We present results on dielectron production in 40 Ar+KCl collisions at 1.76A GeV. For the first time ω mesons could be reconstructed in a heavy-ion reaction at a bombarding energy which is well below the production threshold in free nucleon-nucleon collisions. The ω multiplicity has been extracted and compared to the yields of other particles, in particular of the φ meson. At intermediate e + e invariant masses, we find a strong enhancement of the pair yield over a reference spectrum from elementary nucleon-nucleon reactions suggesting the onset of non-trivial effects of the nuclear medium. Transverse-mass spectra and angular distributions have been reconstructed in three invariant mass bins. In the former unexpectedly large slopes are found for high-mass pairs. The latter, in particular the helicity-angle distributions, are largely consistent with expectations for ]


Physics Letters B | 2015

Partial wave analysis of the reaction p(3.5 GeV)+p → pK+Λ to search for the “ppK−” bound state

G. Agakishiev; O. W. Arnold; D. Belver; Alexander Belyaev; J.C. Berger-Chen; A. Blanco; M. Böhmer; J. L. Boyard; P. Cabanelas; S. Chernenko; A. Dybczak; E. Epple; L. Fabbietti; O. Fateev; P. Finocchiaro; P. Fonte; J. Friese; I. Fröhlich; T. Galatyuk; J. A. Garzón; R. Gernhäuser; K. Göbel; M. Golubeva; D. González-Díaz; F. Guber; M. Gumberidze; T. Heinz; T. Hennino; R. Holzmann; A. Ierusalimov

Employing the Bonn-Gatchina partial wave analysis framework (PWA), we have analyzed HADES data of the reaction p(3.5GeV ) + p !pK + �. This reaction might contain information about the kaonic cluster ”ppK − ” via its decay into p�. Due to interference effects in our coherent description of the data, a hypothetical KNN (or, specifically ”ppK − ”) cluster signal must not necessarily show up as a pronounced feature (e.g. a peak) in an invariant mass spectra like p�. Our PWA analysis includes a variety of resonant and non-resonant intermediate states and delivers a good description of our data (various angular distributions and two-hadron invariant mass spectra) without a contribution of a KNN cluster. At a confidence level of CLs=95% such a cluster can not contribute more than 2-12% to the total cross section with a pK + � final state, which translates into a production cross-section between 0.7 µb and 4.2 µb, respectively. The


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014

Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

L. Raczyński; P. Moskal; P. Kowalski; W. Wiślicki; T. Bednarski; P. Białas; E. Czerwiński; Ł. Kapłon; Andrzej Kochanowski; G. Korcyl; Jakub Kowal; T. Kozik; W. Krzemien; E. Kubicz; Marcin Molenda; Ines Moskal; Sz. Niedźwiecki; M. Palka; M. Pawlik-Niedźwiecka; Z. Rudy; P. Salabura; Neha Sharma; M. Silarski; A. Słomski; J. Smyrski; A. Strzelecki; A. Wieczorek; M. Zieliński; Natalia Zoń

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511 keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps ( σ).


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2015

Compressive sensing of signals generated in plastic scintillators in a novel J-PET instrument

L. Raczyński; P. Moskal; P. Kowalski; W. Wiślicki; T. Bednarski; P. Białas; E. Czerwiński; A. Gajos; Ł. Kapłon; Andrzej Kochanowski; G. Korcyl; Jakub Kowal; T. Kozik; W. Krzemien; E. Kubicz; Sz. Niedźwiecki; M. Palka; Z. Rudy; Oleksandr Rundel; P. Salabura; Neha Sharma; M. Silarski; A. Słomski; J. Smyrski; A. Strzelecki; A. Wieczorek; M. Zieliński; Natalia Zoń

The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The discussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sampling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iterative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recovery error. In this paper we show that an average recovery error is approximately inversely proportional to the number of acquired samples.


Bio-Algorithms and Med-Systems | 2014

A novel method based solely on field programmable gate array (FPGA) units enabling measurement of time and charge of analog signals in positron emission tomography (PET)

M. Palka; P. Moskal; T. Bednarski; P. Białas; E. Czerwiński; Ł. Kapłon; Andrzej Kochanowski; G. Korcyl; Jakub Kowal; P. Kowalski; T. Kozik; Wojciech Krzemień; Marcin Molenda; Szymon Niedźwiecki; Monika Pawlik; Lech Razyński; Z. Rudy; P. Salabura; Neha Gupta-Sharma; M. Silarski; A. Słomski; Jerzy Smyrski; A. Strzelecki; W. Wiślicki; M. Zieliński; Natalia Zoń

Abstract This article presents an application of a novel technique for precise measurements of time and charge based solely on a field programmable gate array (FPGA) device for positron emission tomography (PET). The described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics, and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of ~15 ps (rms) and thus enables sampling of signals in a voltage domain.


Physics in Medicine and Biology | 2016

Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph.

P. Moskal; Oleksandr Rundel; D. Alfs; T. Bednarski; P. Białas; E. Czerwiński; A. Gajos; Krzysztof Giergiel; M. Gorgol; B. Jasińska; D. Kamińska; Ł. Kapłon; G. Korcyl; P. Kowalski; T. Kozik; W. Krzemien; E. Kubicz; Sz. Niedźwiecki; M. Palka; L. Raczyński; Z. Rudy; Neha Sharma; A. Słomski; M. Silarski; A. Strzelecki; A. Wieczorek; W. Wiślicki; Piotr Witkowski; M. Zieliński; Natalia Zoń

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the [Formula: see text] configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the [Formula: see text] matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of [Formula: see text]0.170 ns for 15 cm axial field-of-view (AFOV) and [Formula: see text]0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.


Nuclear Physics | 2013

pK + Λ final state: Towards the extraction of the ppK − contribution

L. Fabbietti; G. Agakishiev; C. Behnke; D. Belver; Alexander Belyaev; J.C. Berger-Chen; A. Blanco; C. Blume; M. Böhmer; P. Cabanelas; S. Chernenko; C. Dritsa; A. Dybczak; E. Epple; O. Fateev; P. Fonte; J. Friese; I. Fröhlich; T. Galatyuk; J. A. Garzón; K. Gill; M. Golubeva; D. González-Díaz; F. Guber; M. Gumberidze; S. Harabasz; T. Hennino; C. Höhne; R. Holzmann; P. Huck

Abstract The reaction p ( @ 3.5 GeV ) + p → p + Λ + K + can be studied to search for the existence of kaonic bound states like p p K − leading to this final state. This effort has been motivated by the assumption that in p + p collisions the Λ ( 1405 ) resonance can act as a doorway to the formation of the kaonic bound states. The status of this analysis within the HADES Collaboration, with particular emphasis on the comparison to simulations, is shown in this work and the deviation method utilized by the DISTO Collaboration in a similar analysis is discussed. The outcome suggests the employment of a partial wave analysis do disentangle the different contributions to the measured p K + Λ final state.

Collaboration


Dive into the M. Palka's collaboration.

Top Co-Authors

Avatar

G. Korcyl

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Z. Rudy

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar

T. Kozik

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar

L. Raczyński

Maria Curie-Skłodowska University

View shared research outputs
Top Co-Authors

Avatar

P. Kowalski

Maria Curie-Skłodowska University

View shared research outputs
Top Co-Authors

Avatar

M. Silarski

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar

P. Białas

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar

E. Kubicz

Jagiellonian University

View shared research outputs
Top Co-Authors

Avatar

Neha Sharma

Jagiellonian University

View shared research outputs
Researchain Logo
Decentralizing Knowledge