Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Maciej Dębski is active.

Publication


Featured researches published by Maciej Dębski.


Advances in Clinical and Experimental Medicine | 2016

Venous Stenosis and Occlusion in the Presence of Endocardial Leads.

Krzysztof Boczar; Andrzej Ząbek; Kazimierz Haberka; Małgorzata Hardzina; Maciej Dębski; Anna Rydlewska; Ewa Nowosielska-Ząbek; Jacek Lelakowski; Barbara Małecka

BACKGROUND Venous stenosis and occlusion in the presence of endocardial leads constitute one of the complications of permanent cardiac pacing either by pacemaker, implantable cardioverter-defibrillator or cardiac resynchronization therapy. OBJECTIVES The aim of this study was to assess the incidence of stenosis and occlusions and determine the risk factors in patients with endocardial leads in a prospective single-center study. MATERIAL AND METHODS Two hundred eighty consecutive patients aged 25-95 years (male 68.8%) were included. A contrast venography examination of the ipsilateral access vein was performed. The whole study population was divided into 2 groups, based on the presence (group I) or absence (group II) of endocardial leads. RESULTS Venous stenosis/occlusion was identified in 51 patients (37.5%) in group I and in 3 patients (3.6%) in group II; p < 0.0001. The lead presence most highly correlated with venous complications (OR = 4.172; p < 0.001). In patients with endocardial leads divided into I A and I B according to venous patency diabetes mellitus was proved in multivariate analysis to be the only protective factor against the development of venous stenosis/occlusion (OR = 0.473; p = 0.010). CONCLUSIONS The presence of endocardial leads is a predisposing factor for venous stenosis/occlusion and increases the risk 4-fold. The venous lesions in the presence of endocardial leads are less frequent among patients with diabetes mellitus.


Acta Cardiologica | 2016

Gender differences in dual-chamber pacemaker implantation indications and long-term outcomes.

Maciej Dębski; Ulman M; Ząbek A; Kazimierz Haberka; Jacek Lelakowski; Barbara Małecka

Objective Dual-chamber (DDD) pacing is the most commonly used mode of heart stimulation. The data on gender-related differences in the long-term follow-up of DDD pacing mode are still limited. We performed a retrospective single-centre study to determine the effect of gender on the implantation indications and the incidence of adverse events resulting in DDD mode loss. Methods and results A group of 1,049 consecutive patients with DDD pacemaker implanted between 1984 and 2002 were followed up until 2014. The study group consisted of 995 patients who performed at least one follow-up visit. Follow-up period was 124.2 ± 68.3 months, mean age was 63.5 ± 12.4 years, 56% were male. Adverse events were defined as loss of primary DDD stimulation – lead malfunction, progression to permanent AF, and infective complications. Women were older than men (64.7 vs 62.6 years) at the time of implantation and they remained, on average, 1.5 year longer in follow-up compared with men. Female patients had significantly more SSS, history of paroxysmal AF, and a similar percentage of AVB compared with male patients. The incidence of lead malfunction, device-related infections, and progression to permanent AF did not show significant differences. However, in the group without prior paroxysmal AF, women developed permanent AF more frequently. Conclusions This patients cohort showed that there is an association between gender and indications to DDD pacing therapy. The rate of adverse events was similar in both genders. Women had a significantly longer duration of follow-up, despite markedly higher age at implantation.


Acta Cardiologica | 2015

The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-center experience.

Andrzej Zabek; Barbara Małecka; Kazimierz Haberka; Krzysztof Boczar; Roman Pfitzner; Maciej Dębski; Jacek Lelakowski

INTRODUCTION Transvenous lead extraction (TLE) is a recognized method of treatment in the case of permanent stimulation complication. OBJECTIVES The objective of this study was to analyse the indications and presentation of the early experience of TLE procedures in a group of patients with old pacing systems. PATIENTS AND METHODS Patients with a relevant history of stimulation (at least 12 months in case of a pacemaker) qualified for the research. Indications, effectiveness and complications of TLE procedures were analysed. RESULTS Two hundred patients at the age of 66.4 (19.1-86.2 years) were enrolled and 278 leads with dwell time 76.2 months (2.1-327.4) were removed. The indications for TLE were: lead-dependent infective endocarditis in 13 cases (6.5%), pocket infection in 29 cases (14.5%), lead damage in 120 cases (60.0%), and upgrade of device system in 38 cases (19.0%). Manual traction was used to remove 66 active fixation leads (23.7%). A femoral approach was required to extract 4 leads (1.4%). Two hundred and eight leads (74.8%) were extracted using the mechanical (Cook) system and subclavian approach. Laser technique, and an electrosurgical sheath were not used. Complete procedural success was achieved in 96% of cases and overall clinical success was 98.5%. Complication rate was 5.5% (11 patients): minor and major complication rate was 3.0% (6 patients) and 2.5% (5 cases), respectively. Low body mass index (BMI) was associated with a higher rate of complications. CONCLUSIONS The dominant indication to TLE procedures was lead dysfunction. Transvenous lead extraction has a high success rate and a low complication rate. Low BMI increased the complication rate.


Kardiologia Polska | 2018

Differences in knowledge among patients with atrial fibrillation receiving non-vitamin K antagonist oral anticoagulants and vitamin K antagonists

Małgorzata Konieczyńska; Ewa Sobieraj; Agata Hanna Bryk; Maciej Dębski; Maciej Polak; Piotr Podolec; Barbara Małecka; Andrzej Pająk; Lien Desteghe; Hein Heidbuchel; Anetta Undas

BACKGROUND Non-vitamin K antagonist oral anticoagulants (NOACs) are increasingly used for stroke prevention in patients with atrial fibrillation (AF) worldwide. Few articles have compared current understanding of AF patients about the disease and anticoagulant therapy in relation to the medications used. AIM We sought to compare the knowledge of AF and anticoagulation between AF patients treated with NOACs and those on vitamin K antagonists (VKAs). METHODS We used the Jessa AF Knowledge Questionnaire (JAKQ), developed and validated in Belgium. Patients were re-cruited at a tertiary centre in Kraków, Poland. RESULTS A total of 479 AF patients completed the JAKQ. Patients on NOACs (n = 276, 57.6%) compared with those on VKAs (n = 175, 36.5%) did not differ regarding demographic and clinical variables. The mean score of the JAKQ was very similar in the NOAC and VKA group (60.7 ± 17.0% vs. 61.6 ± 17.1%; p = 0.4, respectively). The differences in the proportion of correct responses referred to three questions. Consequences of AF, such as blood clots and cerebral infarction, were more obvious for patients on NOACs compared with those on VKAs (81.5% vs. 70.9%; p = 0.01). The patients on NOACs (78.7% vs. 67.6%; p = 0.009) more frequently considered consulting a physician for advice concerning anticoagulant treatment before surgery, while fewer patients on NOACs were aware of the need to take their medication even if they did not feel AF (76.1% vs. 89.7%; p = 0.0004). Only 25.9% of the VKA patients and 49.3% of the NOAC users knew what to do if they missed a dose of the anticoagulant. CONCLUSIONS The knowledge of arrhythmia and anticoagulation is better regarding the safety issues among subjects on NOACs compared with those on VKAs. Irrespective of the type of oral anticoagulation therapy, education of AF patients should be improved.


Annals of Noninvasive Electrocardiology | 2018

Inhibition of left ventricular stimulation due to left ventricular lead failure and the left ventricular T-wave protection algorithm in patient with cardiac resynchronization therapy and pacemaker dependency

Andrzej Ząbek; Barbara Małecka; Maciej Dębski; Krzysztof Boczar; Jacek Lelakowski

The electrocardiogram (ECG) interpretation in patients with cardiac resynchronization therapy (CRT) is often a perplexing problem. The difficulty in the device evaluation increases in the presence of unfamiliar timing cycles and a lead dysfunction. Authors describe a special function of a Biotronik CRT devices called the left ventricle T‐wave protection (LVTP), and demonstrate its behavior in a patient with left ventricular (LV) lead failure. This report shows that sometimes it might be difficult to understand the loss of resynchronization in 12‐lead ECG when LVTP feature is on, and a malfunction of left ventricular lead sensing occurs.


Acta Cardiologica | 2017

Venous stenosis and occlusion in the presence of endocardial leads in patients referred for transvenous lead extraction

Krzysztof Boczar; Andrzej Zabek; Kazimierz Haberka; Maciej Dębski; Anna Rydlewska; Robert Musial; Jacek Lelakowski; Barbara Małecka

Objective The aim of this study was to evaluate the incidence of venous stenosis and occlusion (VSO) in patients referred for transvenous lead extraction (TLE) with regard to the indications for this treatment and to analyse the influence of VSO on efficacy, complications and technical challenges of TLE procedures. Methods The material consists of 133 consecutive TLE procedure records. The contrast venography examination of the ipsilateral access vein was performed prior to the operation. The whole study population was divided into two subgroups, based on the presence (subgroup I) or absence (subgroup II) of VSO. Results Phlebography was performed in 133 patients with age ranging from 25.7 to 86.1 years, 44 female (33.1%). The VSO was confirmed in 48 (36.1%) patients – subgroup I. Most of the patients were referred to TLE due to non-infectious reasons (100 pts—75.2%). The absence of VSO was observed substantially more frequently in patients with diabetes (P = 0.02). Procedural success rate reached 93.3% in subgroup I and 98.8% in subgroup II (P = 0.1). There was no significant difference in the use of advanced tools and alternative access sites. Conclusion The presence of VSO can be expected in one third of patients referred for lead extraction. There is no association between indication for TLE (infected or noninfected lead extraction) and the incidence of VSO. Diabetes proved to have a protective effect on venous patency in the previously mentioned group. VSO does not influence the effectiveness, safety, and the use of additional tools during TLE procedures.


International Journal of Cardiology | 2016

The utility of a CHA2DS2-VASc score in predicting the presence of significant stenosis and occlusion of veins with indwelling endocardial leads.

Krzysztof Boczar; Andrzej Ząbek; Maciej Dębski; Kazimierz Haberka; Anna Rydlewska; Jacek Lelakowski; Barbara Małecka

BACKGROUND Currently, there are no studies in which a CHA2DS2-VASc score has been used to predict the risk of venous stenosis and occlusion (VSO) in patients after the implantation of a cardiac implantable electronic device (CIED). METHODS The material consists of the records of 223 consecutive patients qualified for transvenous lead extraction, generator change and system revisions or upgrades in whom we assessed the utility of a CHA2DS2-VASc score in the prediction of VSO. The CHA2DS2-VASc score was calculated retrospectively based on the clinical data. The whole study population was divided into two groups, based on the presence (group I) or absence (group II) of VSO. Using the receiver operating characteristic (ROC) curve, we identified the optimal cut-off point for the CHA2DS2-VASc score that allowed the prediction of the absence of VSO. RESULTS The venography was performed in 223 consecutive patients aged on average 68.2years (25.7-95.3), 77 females (34.5%). The presence of VSO was detected in 79 (35.4%) patients aged 68.3±14.1years, 30 female (40%) patients-group I. The level of the cut-off point for the CHA2DS2-VASc score that allowed the prediction of the absence of VSO was 3.0. CONCLUSION In the whole population the incidence of VSO amounted to 35.4%. The result of the CHA2DS2-VASc score was a destimulant of VSO occurrence and was characterized by moderate sensitivity (73.4%) and specificity (42.4%) in predicting the absence of VSO. The most significant factor, which prevented VSO development was diabetes.


Pacing and Clinical Electrophysiology | 2018

Analysis of electrical lead failures in patients referred for transvenous lead extraction procedures

Andrzej Ząbek; Krzysztof Boczar; Maciej Dębski; Mateusz Ulman; Paweł Matusik; Jacek Lelakowski; Barbara Małecka

We evaluated the influences of selected factors on electrical lead failure (ELF) occurrence in patients referred for transvenous lead extraction (TLE) procedures.


Kardiologia Polska | 2018

Lead-related complications after DDD pacemaker implantation

Maciej Dębski; Mateusz Ulman; Andrzej Ząbek; Krzysztof Boczar; Kazimierz Haberka; Marcin Kuniewicz; Jacek Lelakowski; Barbara Małecka

BACKGROUND Pacing leads remain the weakest link in pacemaker systems despite advances in manufacturing technology. AIM The aim of the study was to assess the long-term pacing lead performance in an unselected real-life cohort following primary DDD pacing system implantation. METHODS A single-centre retrospective analysis of patients who underwent DDD pacing system implantation between October 1984 and December 2014 and were followed-up until August 2016 was conducted. The inclusion criterion was at least one follow-up visit after post-implant discharge. The performance of each atrial and ventricular lead implanted was evaluated during the follow-up period, and the incidence of, and predictive factors for, lead dislodgement and failure were analysed. RESULTS The data of 3771 patients and 24,431.8 patient-years of follow-up were analysed. The mean follow-up of patients was 77.7 ± 61.8 months. During the study period, 7887 transvenous atrial and right ventricular pacing leads were implanted. Lead dislodgement occurred in 94 (1.2%) leads (92 [2.4%] patients), perforation in 11 (0.1%) leads (10 [0.3%] patients), and lead failure in 329 (4.2%) leads (275 [7.3%] patients). Atrial lead position was a predictive factor for lead dislodgement, while age at implantation, polyurethane 80A insulation, subclavian vein access, unipolar lead construction, and lead manufacturer were multivariate predictors of lead failure. CONCLUSIONS Leads with polyurethane 80A insulation, unipolar construction, and those implanted via subclavian vein puncture exhibited the worst long-term performance.


Journal of Electrocardiology | 2018

Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block

Krzysztof Boczar; Agnieszka Sławuta; Andrzej Ząbek; Maciej Dębski; Jacek Gajek; Jacek Lelakowski; Barbara Małecka

CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%.

Collaboration


Dive into the Maciej Dębski's collaboration.

Top Co-Authors

Avatar

Barbara Małecka

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Jacek Lelakowski

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Krzysztof Boczar

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Andrzej Ząbek

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Kazimierz Haberka

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mateusz Ulman

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Magdalena Kostkiewicz

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Marcin Kuniewicz

Jagiellonian University Medical College

View shared research outputs
Top Co-Authors

Avatar

Paweł Matusik

Jagiellonian University Medical College

View shared research outputs
Researchain Logo
Decentralizing Knowledge