Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Maciej M. Kmiec is active.

Publication


Featured researches published by Maciej M. Kmiec.


Journal of Neurochemistry | 2007

Seizure‐induced formation of isofurans: novel products of lipid peroxidation whose formation is positively modulated by oxygen tension

Manisha Patel; Li-Ping Liang; Huagang Hou; Benjamin B. Williams; Maciej M. Kmiec; Harold M. Swartz; Joshua P. Fessel; L. Jackson Roberts

We have previously shown that seizures induce the formation of F2‐isoprostanes (F2‐IsoPs), one of the most reliable indices of oxidative stress in vivo. Isofurans (IsoFs) are novel products of lipid peroxidation whose formation is favored by high oxygen tensions. In contrast, high oxygen tensions suppress the formation of F2‐IsoPs. The present study determined seizure‐induced formation of IsoFs and its relationship with cellular oxygen levels (pO2). Status epilepticus (SE) resulted in F2‐IsoP and IsoF formation, with overlapping but distinct time courses in hippocampal subregions. IsoF, but not F2‐IsoP formation coincided with mitochondrial oxidative stress. SE resulted in a transient decrease in hippocampal pO2 measured by in vivo electron paramagnetic resonance oximetry suggesting an early phase of seizure‐induced hypoxia. Seizure‐induced F2‐IsoP formation coincided with the peak hypoxia phase, whereas IsoF formation coincided with the ‘reoxygenation’ phase. These results demonstrate seizure‐induced increase in IsoF formation and its correlation with changes in hippocampal pO2 and mitochondrial dysfunction.


Health Physics | 2010

DEVELOPMENT OF IN VIVO TOOTH EPR FOR INDIVIDUAL RADIATION DOSE ESTIMATION AND SCREENING

Benjamin B. Williams; Ruhong Dong; Maciej M. Kmiec; Greg Burke; Eugene Demidenko; David J. Gladstone; Roberto J. Nicolalde; Artur Sucheta; Piotr Lesniewski; Harold M. Swartz

The development of in vivo EPR has made it feasible to perform tooth dosimetry measurements in situ, greatly expanding the potential for using this approach for immediate screening after radiation exposures. The ability of in vivo tooth dosimetry to provide estimates of absorbed dose has been established through a series of experiments using unirradiated volunteers with specifically irradiated molar teeth placed in situ within gaps in their dentition and in natural canine teeth of patients who have completed courses of radiation therapy for head and neck cancers. Multiple measurements in patients who have received radiation therapy demonstrate the expected heterogeneous dose distributions. Dose-response curves have been generated using both populations and, using the current methodology and instrument, the standard error of prediction based on single 4.5-min measurements is approximately 1.5 Gy for inserted molar teeth and between 2.0 and 2.5 Gy in the more irregularly shaped canine teeth. Averaging of independent measurements can reduce this error significantly to values near 1 Gy. Developments to reduce these errors are underway, focusing on geometric optimization of the resonators, detector positioning techniques, and optimal data averaging approaches. In summary, it seems plausible that the EPR dosimetry techniques will have an important role in retrospective dosimetry for exposures involving large numbers of individuals.


Health Physics | 2012

ELECTRON PARAMAGNETIC RESONANCE DOSIMETRY FOR A LARGE-SCALE RADIATION INCIDENT

Harold M. Swartz; Ann Barry Flood; Benjamin B. Williams; Ruhong Dong; Steven G. Swarts; Xiaoming He; Oleg Y. Grinberg; Jason W. Sidabras; Eugene Demidenko; Jiang Gui; David J. Gladstone; Lesley A. Jarvis; Maciej M. Kmiec; Kyo Kobayashi; Piotr Lesniewski; Stephen D.P. Marsh; Thomas P. Matthews; Roberto J. Nicolalde; Patrick M. Pennington; Timothy Raynolds; Ildar Salikhov; Dean E. Wilcox; Bassem I. Zaki

Abstract With possibilities for radiation terrorism and intensified concerns about nuclear accidents since the recent Fukushima Daiichi event, the potential exposure of large numbers of individuals to radiation that could lead to acute clinical effects has become a major concern. For the medical community to cope with such an event and avoid overwhelming the medical care system, it is essential to identify not only individuals who have received clinically significant exposures and need medical intervention but also those who do not need treatment. The ability of electron paramagnetic resonance to measure radiation-induced paramagnetic species, which persist in certain tissues (e.g., teeth, fingernails, toenails, bone, and hair), has led to this technique becoming a prominent method for screening significantly exposed individuals. Although the technical requirements needed to develop this method for effective application in a radiation event are daunting, remarkable progress has been made. In collaboration with General Electric and through funding committed by the Biomedical Advanced Research and Development Authority, electron paramagnetic resonance tooth dosimetry of the upper incisors is being developed to become a Food and Drug Administration-approved and manufacturable device designed to carry out triage for a threshold dose of 2 Gy. Significant progress has also been made in the development of electron paramagnetic resonance nail dosimetry based on measurements of nails in situ under point-of-care conditions, and in the near future this may become a second field-ready technique. Based on recent progress in measurements of nail clippings, it is anticipated that this technique may be implementable at remotely located laboratories to provide additional information when the measurements of dose on-site need to be supplemented. The authors conclude that electron paramagnetic resonance dosimetry is likely to be a useful part of triage for a large-scale radiation incident.


International Journal of Biomedical Imaging | 2012

Surface wave multipath signals in near-field microwave imaging

Paul M. Meaney; Fridon Shubitidze; Margaret W. Fanning; Maciej M. Kmiec; Neil R. Epstein; Keith D. Paulsen

Microwave imaging techniques are prone to signal corruption from unwanted multipath signals. Near-field systems are especially vulnerable because signals can scatter and reflect from structural objects within or on the boundary of the imaging zone. These issues are further exacerbated when surface waves are generated with the potential of propagating along the transmitting and receiving antenna feed lines and other low-loss paths. In this paper, we analyze the contributions of multi-path signals arising from surface wave effects. Specifically, experiments were conducted with a near-field microwave imaging array positioned at variable heights from the floor of a coupling fluid tank. Antenna arrays with different feed line lengths in the fluid were also evaluated. The results show that surface waves corrupt the received signals over the longest transmission distances across the measurement array. However, the surface wave effects can be eliminated provided the feed line lengths are sufficiently long independently of the distance of the transmitting/receiving antenna tips from the imaging tank floor. Theoretical predictions confirm the experimental observations.


Health Physics | 2010

Surface loop resonator design for in vivo EPR tooth dosimetry using finite element analysis.

Jennifer D. Pollock; Benjamin B. Williams; Jason W. Sidabras; Oleg Y. Grinberg; Ildar Salikhov; Piotr Lesniewski; Maciej M. Kmiec; Harold M. Swartz

Finite element analysis is used to evaluate and design L-band surface loop resonators for in vivo electron paramagnetic resonance (EPR) tooth dosimetry. This approach appears to be practical and useful for the systematic examination and evaluation of resonator configurations to enhance the precision of dose estimates. The effects of loop positioning in the mouth are examined, and it is shown that the sensitivity to loop position along a row of molars is decreased as the loop is moved away from the teeth.


Radiation Protection Dosimetry | 2016

FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY

Wilson Schreiber; Sergey Petryakov; Maciej M. Kmiec; Matthew A. Feldman; Paul M. Meaney; Victoria A. Wood; Holly K. Boyle; Ann Barry Flood; Benjamin B. Williams; Harold M. Swartz

Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario.


PLOS ONE | 2015

Tooth Retrospective Dosimetry Using Electron Paramagnetic Resonance: Influence of Irradiated Dental Composites

Céline M. Desmet; Andrej Djurkin; Ana Maria Dos Santos-Goncalvez; Ruhong Dong; Maciej M. Kmiec; Kyo Kobayashi; Kevin Rychert; Sébastien Beun; Julian Leprince; Gaëtane Leloup; Philippe Leveque; Bernard Gallez

In the aftermath of a major radiological accident, the medical management of overexposed individuals will rely on the determination of the dose of ionizing radiations absorbed by the victims. Because people in the general population do not possess conventional dosimeters, after the fact dose reconstruction methods are needed. Free radicals are induced by radiations in the tooth enamel of victims, in direct proportion to dose, and can be quantified using Electron Paramagnetic Resonance (EPR) spectrometry, a technique that was demonstrated to be very appropriate for mass triage. The presence of dimethacrylate based restorations on teeth can interfere with the dosimetric signal from the enamel, as free radicals could also be induced in the various composites used. The aim of the present study was to screen irradiated composites for a possible radiation-induced EPR signal, to characterize it, and evaluate a possible interference with the dosimetric signal of the enamel. We investigated the most common commercial composites, and experimental compositions, for a possible class effect. The effect of the dose was studied between 10 Gy and 100 Gy using high sensitivity X-band spectrometer. The influence of this radiation-induced signal from the composite on the dosimetric signal of the enamel was also investigated using a clinical L-Band EPR spectrometer, specifically developed in the EPR center at Dartmouth College. In X-band, a radiation-induced signal was observed for high doses (25-100 Gy); it was rapidly decaying, and not detected after only 24h post irradiation. At 10 Gy, the signal was in most cases not measurable in the commercial composites tested, with the exception of 3 composites showing a significant intensity. In L-band study, only one irradiated commercial composite influenced significantly the dosimetric signal of the tooth, with an overestimation about 30%. In conclusion, the presence of the radiation-induced signal from dental composites should not significantly influence the dosimetry for early dose assessment.


Radiation Protection Dosimetry | 2016

Dielectric-Backed Aperture Resonators for X-Band in vivo EPR Nail Dosimetry

Oleg Y. Grinberg; Jason W. Sidabras; D. S. Tipikin; Vladimir Krymov; Michael Mariani; Matthew M. Feldman; Maciej M. Kmiec; Sergey Petryakov; Spencer Brugger; Brandon Carr; Wilson Schreiber; Steven G. Swarts; Harold M. Swartz

A new resonator for X-band in vivo EPR nail dosimetry, the dielectric-backed aperture resonator (DAR), is developed based on rectangular TE102 geometry. This novel geometry for surface spectroscopy improves at least a factor of 20 compared to a traditional non-backed aperture resonator. Such an increase in EPR sensitivity is achieved by using a non-resonant dielectric slab, placed on the aperture inside the cavity. The dielectric slab provides an increased magnetic field at the aperture and sample, while minimizing sensitive aperture resonance conditions. This work also introduces a DAR semi-spherical (SS)-TE011 geometry. The SS-TE011 geometry is attractive due to having twice the incident magnetic field at the aperture for a fixed input power. It has been shown that DAR provides sufficient sensitivity to make biologically relevant measurements both in vitro and in vivo Although in vivo tests have shown some effects of physiological motions that suggest the necessity of a more robust finger holder, equivalent dosimetry sensitivity of approximately 1.4 Gy has been demonstrated.


Cell Biochemistry and Biophysics | 2017

Development of the Implantable Resonator System for Clinical EPR Oximetry

Rose M. Caston; Wilson Schreiber; Huagang Hou; Benjamin B. Williams; Eunice Y. Chen; Philip E. Schaner; Lesley A. Jarvis; Ann Barry Flood; Sergey Petryakov; Maciej M. Kmiec; Periannan Kuppusamy; Harold M. Swartz

Hypoxic tumors are more resistant to radiotherapy and chemotherapy, which decreases the efficacy of these common forms of treatment. We have been developing implantable paramagnetic particulates to measure oxygen in vivo using electron paramagnetic resonance. Once implanted, oxygen can be measured repeatedly and non-invasively in superficial tissues (<3 cm deep), using an electron paramagnetic resonance spectrometer and an external surface-loop resonator. To significantly extend the clinical applications of electron paramagnetic resonance oximetry, we developed an implantable resonator system to obtain measurements at deeper sites. This system has been used to successfully obtain oxygen measurements in animal studies for several years. We report here on recent developments needed to meet the regulatory requirements to make this technology available for clinical use. radio frequency heating is discussed and magnetic resonance compatibility testing of the device has been carried out by a Good Laboratory Practice-certified laboratory. The geometry of the implantable resonator has been modified to meet our focused goal of verifying safety and efficacy for the proposed use of intracranial measurements and also for future use in tissue sites other than the brain. We have encapsulated the device within a smooth cylindrical-shaped silicone elastomer to prevent tissues from adhering to the device and to limit perturbation of tissue during implantation and removal. We have modified the configuration for simultaneously measuring oxygen at multiple sites by developing a linear array of oxygen sensing probes, which each provide independent measurements. If positive results are obtained in additional studies which evaluate biocompatibility and chemical characterization, we believe the implantable resonator will be at a suitable stage for initial testing in human subjects.


Radiation Protection Dosimetry | 2016

Surface Dielectric Resonators for X-band EPR Spectroscopy

Sergey Petryakov; Wilson Schreiber; Maciej M. Kmiec; Benjamin B. Williams; Harold M. Swartz

A new resonator for X-band electron paramagnetic resonance (EPR) spectroscopy, which utilizes the unique resonance properties of dielectric substrates, has been developed using a single crystal of titanium dioxide. As a result of the dielectric properties of the crystal(s) chosen, this novel resonator provides the ability to make in vivo EPR spectroscopy surface measurements in the presence of lossy tissues at X-band frequencies (up to 10 GHz). A double-loop coupling device is used to transmit and receive microwave power to/from the resonator. This coupler has been developed and optimized for coupling to the resonator in the presence of lossy tissues to further enable in vivo measurements, such as in vivo EPR spectroscopy of human fingernails or teeth to measure the dose of ionizing radiation that a given individual has been exposed to. An advantage of this resonator for surface measurements is that the magnetic fields generated by the resonator are inherently shallow, which is desirable for in vivo nail dosimetry.

Collaboration


Dive into the Maciej M. Kmiec's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jason W. Sidabras

Medical College of Wisconsin

View shared research outputs
Researchain Logo
Decentralizing Knowledge