Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mads Møller Pedersen is active.

Publication


Featured researches published by Mads Møller Pedersen.


New Biotechnology | 2010

Lignocellulose pretreatment severity – relating pH to biomatrix opening

Mads Møller Pedersen; Anne S. Meyer

In cellulose-to-ethanol processes a physico-chemical pretreatment of the lignocellulosic feedstock is a crucial prerequisite for increasing the amenability of the cellulose to enzymatic attack. Currently published pretreatment strategies span over a wide range of reaction conditions involving different pH values, temperatures, types of catalysts and holding times. The consequences of the pretreatment on lignocellulosic biomass are described with special emphasis on the chemical alterations of the biomass during pretreatment, especially highlighting the significance of the pretreatment pH. We present a new illustration of the pretreatment effects encompassing the differential responses to the pH and temperature. A detailed evaluation of the use of severity factor calculations for pretreatment comparisons signifies that the multiple effects of different pretreatment factors on the subsequent monosaccharide yields after enzymatic hydrolysis cannot be reliably compared by a one-dimensional severity factor, even within the same type of pretreatment strategy. However, a quantitative comparison of published data for wheat straw pretreatment illustrates that there is some correlation between the hydrolysis yields (glucose and xylose) and the pretreatment pH, but no correlation with the pretreatment temperature (90-200°C). A better recognition and understanding of the factors affecting biomatrix opening, and use of more standardized evaluation protocols, will allow for the identification of new pretreatment strategies that improve biomass utilization and permit rational enzymatic hydrolysis of the cellulose.


Biotechnology Progress | 2009

Influence of substrate particle size and wet oxidation on physical surface structures and enzymatic hydrolysis of wheat straw.

Mads Møller Pedersen; Anne S. Meyer

In the worldwide quest for producing biofuels from lignocellulosic biomass, the importance of the substrate pretreatment is becoming increasingly apparent. This work examined the effects of reducing the substrate particle sizes of wheat straw by grinding prior to wet oxidation and enzymatic hydrolysis. The yields of glucose and xylose were assessed after treatments with a benchmark cellulase system consisting of Celluclast 1.5 L (Trichoderma reesei) and Novozym 188 β‐glucosidase (Aspergillus niger). Both wet oxidized and not wet oxidized wheat straw particles gave increased glucose release with reduced particle size. After wet oxidation, the glucose release from the smallest particles (53–149 μm) reached 90% of the theoretical maximum after 24 h of enzyme treatment. The corresponding glucose release from the wet oxidized reference samples (2–4 cm) was ∼65% of the theoretical maximum. The xylose release only increased (by up to 39%) with particle size decrease for the straw particles that had not been wet oxidized. Wet oxidation pretreatment increased the enzymatic xylose release by 5.4 times and the glucose release by 1.8 times across all particle sizes. Comparison of scanning electron microscopy images of the straw particles revealed edged, nonspherical, porous particles with variable surface structures as a result of the grinding. Wet oxidation pretreatment tore up the surface structures of the particles to retain vascular bundles of xylem and phloem. The enzymatic hydrolysis left behind a significant amount of solid, apparently porous structures within all particles size groups of both the not wet oxidized and wet oxidized particles.


Biotechnology for Biofuels | 2011

Low temperature lignocellulose pretreatment: effects and interactions of pretreatment pH are critical for maximizing enzymatic monosaccharide yields from wheat straw

Mads Møller Pedersen; Katja Salomon Johansen; Anne S. Meyer

BackgroundThe recent development of improved enzymes and pentose-using yeast for cellulosic ethanol processes calls for new attention to the lignocellulose pretreatment step. This study assessed the influence of pretreatment pH, temperature, and time, and their interactions on the enzymatic glucose and xylose yields from mildly pretreated wheat straw in multivariate experimental designs of acid and alkaline pretreatments.ResultsThe pretreatment pH was the most significant factor affecting both the enzymatic glucose and xylose yields after mild thermal pretreatments at maximum 140°C for 10 min. The maximal enzymatic glucose and xylose yields from the solid, pretreated wheat straw fraction were obtained after pretreatments at the most extreme pH values (pH 1 or pH 13) at the maximum pretreatment temperature of 140°C. Surface response models revealed significantly correlating interactions of the pretreatment pH and temperature on the enzymatic liberation of both glucose and xylose from pretreated, solid wheat straw. The influence of temperature was most pronounced with the acidic pretreatments, but the highest enzymatic monosaccharide yields were obtained after alkaline pretreatments. Alkaline pretreatments also solubilized most of the lignin.ConclusionsPretreatment pH exerted significant effects and factor interactions on the enzymatic glucose and xylose releases. Quite extreme pH values were necessary with mild thermal pretreatment strategies (T ≤ 140°C, time ≤ 10 min). Alkaline pretreatments generally induced higher enzymatic glucose and xylose release and did so at lower pretreatment temperatures than required with acidic pretreatments.


Ultrasound in Medicine and Biology | 2012

Comparison of Real-Time In Vivo Spectral and Vector Velocity Estimation

Mads Møller Pedersen; Michael Johannes Pihl; Per Haugaard; Jens Hansen; Kristoffer Lindskov Hansen; Michael Bachmann Nielsen; Jørgen Arendt Jensen

The purpose of this study is to show whether a newly introduced vector flow method is equal to conventional spectral estimation. Thirty-two common carotid arteries of 16 healthy volunteers were scanned using a BK Medical ProFocus scanner (DK-2730, Herlev, Denmark) and a linear transducer at 5 MHz. A triplex imaging sequence yields both the conventional velocity spectrum and a two-dimensional vector velocity image. Several clinical parameters were estimated and compared for the two methods: Flow angle, peak systole velocity (PS), end diastole velocity (ED) and resistive index (RI). With a paired t-test, the spectral and vector angles did not differ significantly (p = 0.658), whereas PS (p = 0.034), ED (p = 0.004) and RI (p < 0.0001) differed significantly. Vector flow can measure the angle for spectral angle correction, thus eliminating the bias from the radiologist performing the angle setting with spectral estimation. The flow angle limitation in velocity estimation is also eliminated, so that flow at any angle can be measured.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2012

Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner

Martin Christian Hemmsen; Svetoslav Ivanov Nikolov; Mads Møller Pedersen; Michael Johannes Pihl; Marie Sand Enevoldsen; Jens Hansen; Jørgen Arendt Jensen

This paper describes the design and implementation of a versatile, open-architecture research data acquisition system using a commercially available medical ultrasound scanner. The open architecture will allow researchers and clinicians to rapidly develop applications and move them relatively easy to the clinic. The system consists of a standard PC equipped with a camera link and an ultrasound scanner equipped with a research interface. The ultrasound scanner is an easy-to-use imaging device that is capable of generating high-quality images. In addition to supporting the acquisition of multiple data types, such as B-mode, M-mode, pulsed Doppler, and color flow imaging, the machine provides users with full control over imaging parameters such as transmit level, excitation waveform, beam angle, and focal depth. Beamformed RF data can be acquired from regions of interest throughout the image plane and stored to a file with a simple button press. For clinical trials and investigational purposes, when an identical image plane is desired for both an experimental and a reference data set, interleaved data can be captured. This form of data acquisition allows switching between multiple setups while maintaining identical transducer, scanner, region of interest, and recording time. Data acquisition is controlled through a graphical user interface running on the PC. This program implements an interface for third-party software to interact with the application. A software development toolkit is developed to give researchers and clinicians the ability to utilize third-party software for data analysis and flexible manipulation of control parameters. Because of the advantages of speed of acquisition and clinical benefit, research projects have successfully used the system to test and implement their customized solutions for different applications. Three examples of system use are presented in this paper: evaluation of synthetic aperture sequential beamformation, transverse oscillation for blood velocity estimation, and acquisition of spectral velocity data for evaluating aortic aneurysms.


Ultrasound in Medicine and Biology | 2014

Volume Flow in Arteriovenous Fistulas Using Vector Velocity Ultrasound

Peter Møller Hansen; Jacob Bjerring Olesen; Michael Johannes Pihl; Theis Lange; Søren T. Heerwagen; Mads Møller Pedersen; Marianne Rix; Lars Lönn; Jørgen Arendt Jensen; Michael Bachmann Nielsen

Volume flow in arteriovenous fistulas for hemodialysis was measured using the angle-independent ultrasound technique Vector Flow Imaging and compared with flow measurements using the ultrasound dilution technique during dialysis. Using an UltraView 800 ultrasound scanner (BK Medical, Herlev, Denmark) with a linear transducer, 20 arteriovenous fistulas were scanned directly on the most superficial part of the fistula just before dialysis. Vector Flow Imaging volume flow was estimated with two different approaches, using the maximum and the average flow velocities detected in the fistula. Flow was estimated to be 242 mL/min and 404 mL/min lower than the ultrasound dilution technique estimate, depending on the approach. The standard deviations of the two Vector Flow Imaging approaches were 175.9 mL/min and 164.8 mL/min compared with a standard deviation of 136.9 mL/min using the ultrasound dilution technique. The study supports that Vector Flow Imaging is applicable for volume flow measurements.


Ultraschall in Der Medizin | 2011

New technology - demonstration of a vector velocity technique.

Peter Møller Hansen; Mads Møller Pedersen; Kristoffer Lindskov Hansen; Michael Bachmann Nielsen; Jørgen Arendt Jensen

With conventional Doppler ultrasound it is not possible to estimate direction and velocity of blood flow, when the angle of insonation exceeds 60-70°. Transverse oscillation is an angle independent vector velocity technique which is now implemented on a conventional ultrasound scanner. In this paper a few of the possibilities with transverse oscillation are demonstrated.


Ultrasonics | 2015

First report on intraoperative vector flow imaging of the heart among patients with healthy and diseased aortic valves

Kristoffer Lindskov Hansen; Hasse Møller-Sørensen; Mads Møller Pedersen; Peter Møller Hansen; Jesper Kjaergaard; Jens T. Lund; Jens C. Nilsson; Jørgen Arendt Jensen; Michael Bachmann Nielsen

The vector velocity method Transverse Oscillation (TO) implemented on a conventional ultrasound (US) scanner (ProFocus, BK Medical, Herlev, Denmark) can provide real-time, angle-independent estimates of the cardiac blood flow. During cardiac surgery, epicardial US examination using TO was performed on (A) 3 patients with healthy aortic valve and (B) 3 patients with aortic valve stenosis. In group B, the systolic flow of the ascending aorta had higher velocities, was more aliased and chaotic. The jet narrowed to 44% of the lumen compared to 75% in group A and with a vector concentration, a measure of flow complexity, of 0.41 compared to 0.87 in group A. The two groups had similar secondary flow of the ascending aorta with an average rotation frequency of 4.8 Hz. Simultaneous measurements were obtained with spectral Doppler (SD) and a thermodilution technique (TD). The mean difference in peak systolic velocity compared to SD in group A was 22% and 45% in B, while the mean difference in volume flow compared to TD in group A was 30% and 32% in B. TO can potentially reveal new information of cardiac blood flow, and may become a valuable diagnostic tool in the evaluation of patients with cardiovascular diseases.


Ultrasonic Imaging | 2013

Intraoperative cardiac ultrasound examination using vector flow imaging.

Kristoffer Lindskov Hansen; Mads Møller Pedersen; Hasse Møller-Sørensen; Jesper Kjaergaard; Jens C. Nilsson; Jens T. Lund; Jørgen Arendt Jensen; Michael Bachmann Nielsen

Conventional ultrasound (US) methods for blood velocity estimation only provide one-dimensional and angle-dependent velocity estimates; thus, the complexity of cardiac flow has been difficult to measure. To circumvent these limitations, the Transverse Oscillation (TO) vector flow method has been proposed. The vector flow method implemented on a commercial scanner provided real-time, angle-independent estimates of cardiac blood flow. Epicardiac and epiaortic, intraoperative US examinations were performed on three patients with stenosed coronary arteries scheduled for bypass surgery. Repeating cyclic beat-to-beat flow patterns were seen in the ascending aorta and pulmonary artery of each patient, but these patterns varied between patients. Early systolic retrograde flow filling the aortic sinuses was seen in the ascending aorta as well as early systolic retrograde flow in the pulmonary artery. In diastole, stable vortices in aortic sinuses of the ascending aorta created central antegrade flow. A stable vortex in the right atrium was seen during the entire heart cycle. The measurements were compared with estimates obtained intraoperatively with conventional spectral Doppler US using a transesophageal and an epiaortic approach. Mean differences in peak systole velocity of 11% and 26% were observed when TO was compared with transesophageal echocardiography and epiaortic US, respectively. In one patient, the cardiac output derived from vector velocities was compared with pulmonary artery catheter thermodilution technique and showed a difference of 16%. Vector flow provides real-time, angle-independent vector velocities of cardiac blood flow. The technique can potentially reveal new information of cardiovascular physiology and give insight into blood flow dynamics.


Ultrasound in Medicine and Biology | 2014

Novel Flow Quantification of the Carotid Bulb and the Common Carotid Artery with Vector Flow Ultrasound

Mads Møller Pedersen; Michael Johannes Pihl; Per Haugaard; Kristoffer Lindskov Hansen; Theis Lange; Lars Lönn; Michael Bachmann Nielsen; Jørgen Arendt Jensen

Abnormal blood flow is usually assessed using spectral Doppler estimation of the peak systolic velocity. The technique, however, only estimates the axial velocity component, and therefore the complexity of blood flow remains hidden in conventional ultrasound examinations. With the vector ultrasound technique transverse oscillation the blood velocities of both the axial and the transverse directions are obtained and the complexity of blood flow can be visualized. The aim of the study was to determine the technical performance and interpretation of vector concentration as a tool for estimation of flow complexity. A secondary aim was to establish accuracy parameters to detect flow changes/patterns in the common carotid artery (CCA) and the carotid bulb (CB). The right carotid bifurcation including the CCA and CB of eight healthy volunteers were scanned in a longitudinal plane with vector flow ultrasound (US) using a commercial vector flow ultrasound scanner (ProFocus, BK Medical, Denmark) with a linear 5 MHz transducer transverse oscillation vector flow software. CCA and CB areas were marked in one cardiac cycle from each volunteer. The complex flow was assessed by medical expert evaluation and by vector concentration calculation. A vortex with complex flow was found in all carotid bulbs, whereas the CCA had mainly laminar flow. The medical experts evaluated the flow to be mainly laminar in the CCA (0.82 ± 0.14) and mainly complex (0.23 ± 0.22) in the CB. Likewise, the estimated vector concentrations in CCA (0.96 ± 0.16) indicated mainly laminar flow and in CB (0.83 ± 0.07) indicated mainly turbulence. Both methods were thus able to clearly distinguish the flow patterns of CCA and CB in systole. Vector concentration from angle-independent vector velocity estimates is a quantitative index, which is simple to calculate and can differentiate between laminar and complex flow.

Collaboration


Dive into the Mads Møller Pedersen's collaboration.

Top Co-Authors

Avatar

Jørgen Arendt Jensen

Technical University of Denmark

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael Johannes Pihl

Technical University of Denmark

View shared research outputs
Top Co-Authors

Avatar

Martin Christian Hemmsen

Technical University of Denmark

View shared research outputs
Top Co-Authors

Avatar

Anne S. Meyer

Technical University of Denmark

View shared research outputs
Top Co-Authors

Avatar

Hasse Møller-Sørensen

Copenhagen University Hospital

View shared research outputs
Top Co-Authors

Avatar

Jens T. Lund

Copenhagen University Hospital

View shared research outputs
Top Co-Authors

Avatar

Jesper Kjaergaard

Copenhagen University Hospital

View shared research outputs
Top Co-Authors

Avatar

Lars Lönn

University of Copenhagen

View shared research outputs
Researchain Logo
Decentralizing Knowledge