Magnus Åslund
Royal Institute of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Magnus Åslund.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2010
Erik Fredenberg; Mats Lundqvist; Björn Cederström; Magnus Åslund; Mats Danielsson
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the ...
Medical Physics | 2007
Magnus Åslund; Björn Cederström; Mats Lundqvist; Mats Danielsson
The physical performance of a scanning multislit full field digital mammography system was determined using basic image quality parameters. The system employs a direct detection detector comprised of linear silicon strip sensors in an edge-on geometry connected to photon counting electronics. The pixel size is 50 microm and the field of view 24 x 26 cm2. The performance was quantified using the presampled modulation transfer function, the normalized noise power spectrum and the detective quantum efficiency (DQE). Compared to conventional DQE methods, the scanning geometry with its intrinsic scatter rejection poses additional requirements on the measurement setup, which are investigated in this work. The DQE of the photon counting system was found to be independent of the dose level to the detector in the 7.6-206 microGy range. The peak DQE was 72% and 73% in the scan and slit direction, respectively, measured with a 28 kV W-0.5 mm Al anode-filter combination with an added 2 mm Al filtration.
Medical Physics | 2006
Magnus Åslund; Björn Cederström; Mats Lundqvist; Mats Danielsson
The scatter to primary ratio (SPR) was measured on a scanning multislit full-field digital mammography system for different thickness of breast equivalent material and different tube voltages. Scatter within the detector was measured separately and was found to be the major source of scatter in the assembly. Measured total SPRs below 6% are reported for breast range 3-7 cm. The performance of the multislit assembly is compared to other imaging geometries with different scatter rejection schemes by using the scatter detective quantum efficiency.
Medical Physics | 2010
Erik Fredenberg; Magnus Hemmendorff; Björn Cederström; Magnus Åslund; Mats Danielsson
PURPOSE Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. METHODS A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. RESULTS Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another approximately 70%-90% improvement was found to be within reach for an optimized system. CONCLUSIONS Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.
Radiation Protection Dosimetry | 2010
Magnus Åslund; Erik Fredenberg; M. Telman; Mats Danielsson
In recent decades, developments in detectors for X-ray imaging have improved dose efficiency. This has been accomplished with for example, structured scintillators such as columnar CsI, or with direct detectors where the X rays are converted to electric charge carriers in a semiconductor. Scattered radiation remains a major noise source, and fairly inefficient anti-scatter grids are still a gold standard. Hence, any future development should include improved scatter rejection. In recent years, photon-counting detectors have generated significant interest by several companies as well as academic research groups. This method eliminates electronic noise, which is an advantage in low-dose applications. Moreover, energy-sensitive photon-counting detectors allow for further improvements by optimising the signal-to-quantum-noise ratio, anatomical background subtraction or quantitative analysis of object constituents. This paper reviews state-of-the-art photon-counting detectors, scatter control and their application in diagnostic X-ray medical imaging. In particular, spectral imaging with photon-counting detectors, pitfalls such as charge sharing and high rates and various proposals for mitigation are discussed.
Proceedings of SPIE | 2009
Erik Fredenberg; Mats Lundqvist; Magnus Åslund; Magnus Hemmendorff; Björn Cederström; Mats Danielsson
We present the first evaluation of a recently developed silicon-strip detector for photon-counting dual-energy breast tomosynthesis. The detector is well suited for tomosynthesis with high dose efficiency and intrinsic scatter rejection. A method was developed for measuring the spatial resolution of a system based on the detector in terms of the three-dimensional modulation transfer function (MTF). The measurements agreed well with theoretical expectations, and it was seen that depth resolution was won at the cost of a slightly decreased lateral resolution. This may be a justifiable trade-off as clinical images acquired with the system indicate improved conspicuity of breast lesions. The photon-counting detector enables dual-energy subtraction imaging with electronic spectrumsplitting. This improved the detectability of iodine in phantom measurements, and the detector was found to be stable over typical clinical acquisition times. A model of the energy resolution showed that further improvements are within reach by optimization of the detector.
Medical Imaging 2003: Physics of Medical Imaging | 2003
Mats Lundqvist; Mats Danielsson; Bjoern Cederstroem; Valery Chmill; Alexander Chuntonov; Magnus Åslund
Sectra Microdose is the first single photon counting mammography detector. An edge-on crystalline silicon detector is connected to application specific integrated circuits that individually process each photon. The detector is scanned across the breast and the rejection of scattered radiation exceeds 97% without the use of a Bucky. Processing of each x-rays individually enables an optimization of the information transfer from the x-rays to the image in a way previously not possible. Combined with an almost absence of noise from scattered radiation and from electronics we foresee a possibility to reduce the radiation dose and/or increase the image quality. We will discuss fundamental features of the new direct photon counting technique in terms of dose efficiency and present preliminary measurements for a prototype on physical parameters such as Noise Power Spectra (NPS), MTF and DQE.
Medical Physics | 2005
Magnus Åslund; Björn Cederström; Mats Lundqvist; Mats Danielsson
A theoretical evaluation of nonuniform x-ray field distributions in mammography was conducted. An automatic exposure control (AEC) is proposed for a scanning full field digital mammography system. It uses information from the leading part of the detector to vary the scan velocity dynamically, thus creating a nonuniform x-ray field in the scan direction. Nonuniform radiation fields were also created by numerically optimizing the scan velocity profile to each breasts transmission distribution, with constraints on velocity and acceleration. The goal of the proposed AEC is to produce constant pixel signal-to-noise ratio throughout the image. The target pixel SNR for each image could be set based on the breast thickness, breast composition, and the beam quality as to achieve the same contrast-to-noise ratio between images for structures of interest. The results are quantified in terms of reduction in entrance surface air kerma (ESAK) and scan time relative to a uniform x-ray field. The theoretical evaluation was performed on a set of 266 mammograms. The performance of the different methods to create nonuniform fields decreased with increased detector width, from 18% to 11% in terms of ESAK reduction and from 30% to 25% in terms of scan time reduction for the proposed AEC and detector widths from 10to60mm. Some correlation was found between compressed breast thickness and the projected breast area onto the image field. This translated into an increase of the ESAK and decrease of the scan time reduction with breast thickness. Ideally a nonuniform field in two dimensions could reduce the entrance dose by 39% on average, whereas a field nonuniform in only the scanning dimension ideally yields a 20% reduction. A benefit with the proposed AEC is that the risk of underexposing the densest region of the breast can be virtually eliminated.
Proceedings of SPIE | 2010
Erik Fredenberg; Magnus Åslund; Björn Cederström; Mats Lundqvist; Mats Danielsson
Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. Contrast-enhanced spectral imaging has been thoroughly investigated, but unenhanced imaging may be more useful because it comes as a bonus to the conventional non-energy-resolved absorption image at screening; there is no additional radiation dose and no need for contrast medium. We have used a previously developed theoretical framework and system model that include quantum and anatomical noise to characterize the performance of a photon-counting spectral mammography system with two energy bins for unenhanced imaging. The theoretical framework was validated with synthesized images. Optimal combination of the energy-resolved images for detecting large unenhanced tumors corresponded closely, but not exactly, to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, deteriorated detectability. For small microcalcifications or tumors on uniform backgrounds, however, energy subtraction was suboptimal whereas energy weighting provided a minute improvement. The performance was largely independent of beam quality, detector energy resolution, and bin count fraction. It is clear that inclusion of anatomical noise and imaging task in spectral optimization may yield completely different results than an analysis based solely on quantum noise.
Medical Imaging 2004: Physics of Medical Imaging, 15 February 2004 through 17 February 2004, San Diego, CA | 2004
Magnus Åslund; Björn Cederström; Mats Lundqvist; Mats Danielsson
Measurements and Monte Carlo simulations were used to investigate the scatter properties of a scanned multi-slit digital mammography system. Scatter to primary ratio (S/P) in the center of the image field was calculated for different thickness of breast equivalent material and different tube potentials. The simulated model also varied the angular acceptance, the number of slits and the distance between the slits of a dedicated scatter rejection device. In addition to the expected scatter from the breast equivalent material, scatter within the detector contributes to the S/P-ratio. The main part of the scatter is identified as coming from this process. Measured total S/P-ratios below 3% are reported for breast range 3-8 cm. The scatter-DQE is used as figure-of-merit for comparison to other imaging geometries and scatter rejection schemes.