Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Marco Aurélio Versiani is active.

Publication


Featured researches published by Marco Aurélio Versiani.


International Endodontic Journal | 2009

A comparative study of physicochemical properties of AH Plus, Epiphany, and Epiphany SE root canal sealers

L. M. Resende; F. J. A. Rached-Junior; Marco Aurélio Versiani; A. E. Souza-Gabriel; C. E. S. Miranda; Yara Terezinha Silva-Sousa; M. D. Sousa Neto

AIM To assess the physicochemical properties and the surface morphology of AH Plus, Epiphany, and Epiphany SE root canal sealers. METHODOLOGY Five samples of each material were employed for each test according to ANSI/ADA specification 57. The samples were assigned to four groups: (i) AH Plus; (ii) Epiphany; (iii) Epiphany + Thinning Resin; (iv) Epiphany SE. The distilled water used during the solubility test was submitted to spectrometry to verify the release of calcium ions. The morphologies of the external surface and the cross-section of the samples were analysed by means of a scanning electron microscope (SEM). Statistical analysis was performed by using One-Way ANOVA and post hoc Tukey-Kramer tests with the null hypothesis set as 5%. RESULTS Setting time, flow and radiopacity results were in accordance with ANSI/ADA requirements whereas the dimensional change of all sealers and solubility of Epiphany did not fulfil ANSI/ADA protocols. AH Plus and Epiphany SE were similar in terms of flow, radiopacity, solubility and dimensional change. The spectrometry test revealed significant calcium ion release from Epiphany with and without the thinning resin. SEM analysis revealed essentially a homogeneous surface with compact layer and some rough areas. CONCLUSIONS Setting time, flow, and radiopacity tests conformed to ANSI/ADA standardization. The dimensional change in all groups and the solubility of Epiphany were greater than values considered acceptable, with higher amounts of calcium ion release. Epiphany SE revealed more organized, compacted, and homogeneous polymers in a reduced resin matrix when compared with the other groups.


International Endodontic Journal | 2012

Changes in the surface of four calcium silicate-containing endodontic materials and an epoxy resin-based sealer after a solubility test

R. P. Borges; Manoel Damião Sousa-Neto; Marco Aurélio Versiani; Fuad Jacob Abi Rached-Junior; Gustavo De-Deus; Carlos Eduardo Saraiva Miranda; Jesus Djalma Pécora

AIM To compare the changes in the surface structure and elemental distribution, as well as the percentage of ion release, of four calcium silicate-containing endodontic materials with a well-established epoxy resin-based sealer, submitted to a solubility test. METHODOLOGY Solubility of AH Plus, iRoot SP, MTA Fillapex, Sealapex and MTA-Angelus (MTA-A) was tested according to ANSI/ADA Specification 57. The deionized water used in the solubility test was submitted to atomic absorption spectrophotometry to determine and quantify Ca(2+), Na(+), K(+), Zn(2+), Ni(2+) and Pb(2+) ions release. In addition, the outer and inner surfaces of nonsubmitted and submitted samples of each material to the solubility test were analysed by means of scanning electron microscopy and energy-dispersive spectroscopy (SEM/EDX). Statistical analysis was performed by using one-way anova and Tukeys post hoc tests (α = 0.05). RESULTS Solubility results, in percentage, sorted in an increasing order were -1.24 ± 0.19 (MTA-A), 0.28 ± 0.08 (AH Plus), 5.65 ± 0.80 (Sealapex), 14.89 ± 0.73 (MTA Fillapex) and 20.64 ± 1.42 (iRoot SP). AH Plus and MTA-A were statistically similar (P > 0.05), but different from the other materials (P < 0.05). High levels of Ca(2+) ion release were observed in all groups except AH Plus sealer. MTA-A also had the highest release of Na(2+) and K(+) ions. Zn(+2) ion release was observed only with AH Plus and Sealapex sealers. After the solubility test, all surfaces had morphological changes. The loss of matrix was evident and the filler particles were more distinguishable. EDX analysis displayed high levels of calcium and carbon at the surface of Sealapex, MTA Fillapex and iRoot SP. CONCLUSIONS AH Plus and MTA-A were in accordance with ANSI/ADAs requirements regarding solubility whilst iRoot SP, MTA Fillapex and Sealapex did not fulfil ANSI/ADAs protocols. High levels of Ca(2+) ion release were observed in all materials except AH Plus. SEM/EDX analysis revealed that all samples had morphological changes in both outer and inner surfaces after the solubility test. High levels of calcium and carbon were also observed at the surface of all materials except AH Plus and MTA-A.


International Endodontic Journal | 2010

Histological evaluation of the effectiveness of increased apical enlargement for cleaning the apical third of curved canals

V. J. Fornari; Yara Terezinha Silva-Sousa; José Roberto Vanni; Jesus Djalma Pécora; Marco Aurélio Versiani; Manoel Damião Sousa-Neto

OBJECTIVE To evaluate the influence of apical size on cleaning of the apical third of curved canals prepared with rotary instruments. METHODOLOGY Forty-four mesiobuccal canals of maxillary molars teeth were instrumented to different apical sizes (30, 0.02; 35, 0.02; 40, 0.02; 45, 0.02) using a crown-down technique. After canal preparation, the apical thirds of the roots were submitted to histological processing and examination. The specimens were analysed at 40× magnification and the images were submitted to morphometric analysis with an integration grid to evaluate the percentage of debris and uninstrumented root canal walls. The action of the instruments on the root canal walls was assessed based on the surface regularity, abrupt change on the continuity of root canal walls, and partial or total pre-dentine removal. The results were statistically compared using one-way anova with post hoc Tukey test. Pearsons correlation was performed to identify potential correlations between values. RESULTS The percentage of uninstrumented root canal dentine was higher when apical enlargement was performed with instruments 30, 0.02 taper (55.64 ± 4.62%) and 35, 0.02 taper (49.03 ± 5.70%) than with instruments 40, 0.02 taper (38.08 ± 10.44%) and 45, 0.02 taper (32.65 ± 8.51%) (P < 0.05). More debris were observed when apical enlargement was performed with instruments 30, 0.02 taper (34.62 ± 9.49%) and 35, 0.02 taper (25.33 ± 7.37%) (P < 0.05). There was a significant correlation between the amount of remaining debris and the perimeter of uninstrumented root canal dentine (r = 0.9130, P < 0.001). CONCLUSION No apical enlargement size allowed the root canal walls to be prepared completely. Apical third cleanliness could be predicted by instrument diameter.


Journal of Endodontics | 2014

Lack of Causal Relationship between Dentinal Microcracks and Root Canal Preparation with Reciprocation Systems

Gustavo De-Deus; Emmanuel João Nogueira Leal Silva; Juliana Marins; Erick Miranda Souza; Aline de Almeida Neves; Felipe Gonçalves Belladonna; Haimon Diniz Lopes Alves; R.T. Lopes; Marco Aurélio Versiani

INTRODUCTION This study aimed to evaluate the frequency of dentinal microcracks observed after root canal preparation with 2 reciprocating and a conventional full-sequence rotary system using micro-computed tomographic analysis. METHODS Thirty mesial roots of mandibular molars presenting a type II Vertucci canal configuration were scanned at an isotropic resolution of 14.16 μm. The sample was randomly assigned to 3 experimental groups (n = 10) according to the system used for the root canal preparation: group A-Reciproc (VDW, Munich, Germany), group B-WaveOne (Dentsply Maillefer, Baillagues, Switzerland), and group C-BioRaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland). Second and third scans were taken after the root canals were prepared with instruments sizes 25 and 40, respectively. Then, pre- and postoperative cross-section images of the roots (N = 65,340) were screened to identify the presence of dentinal defects. RESULTS Dentinal microcracks were observed in 8.72% (n = 5697), 11.01% (n = 7197), and 7.91% (n = 5169) of the cross-sections from groups A (Reciproc), B (WaveOne), and C (BioRaCe), respectively. All dentinal defects identified in the postoperative cross-sections were also observed in the corresponding preoperative images. CONCLUSIONS No causal relationship between dentinal microcrack formation and canal preparation procedures with Reciproc, WaveOne, and BioRaCe systems was observed.


International Endodontic Journal | 2011

Evaluation of physicochemical properties of four root canal sealers.

D. S. H. Flores; Fuad Jacob Abi Rached-Junior; Marco Aurélio Versiani; D. F. C. Guedes; Manoel Damião Sousa-Neto; Jesus Djalma Pécora

AIM To assess the physicochemical properties and the surface morphology of AH Plus, GuttaFlow, RoekoSeal and Activ GP root canal sealers. METHODOLOGY Five samples of each material were evaluated for setting time, dimensional alteration, solubility and radiopacity tests, according to ANSI/ADA Specification 57. A total of 50 mL of deionized distilled water from the solubility tests were used to measure the metal solubility by atomic absorption spectrometry. The morphologies of the external surface and the cross-section of the samples were analysed by means of a scanning electron microscope (SEM). Statistical analysis was performed by using one-way anova and post hoc Tukey-Kramer tests with the null hypothesis set as 5%. RESULTS AH Plus had the longest setting time (580.6 ± 3.05 min) (P<0.05). Activ GP did not have a mean value on the radiopacity and solubility tests (1.31 ± 0.35 mm and 11.8 ± 0.43%, respectively) in accordance with ANSI/ADA, being significantly different from the other materials (P<0.05), which had mean values for these tests in accordance with the ADAs requirements. GuttaFlow was the only sealer that conformed to the Specification 57 concerning the dimensional alteration test (0.44 ± 0.16%) (P<0.05). The spectrometry test revealed significant Ca(2+), K(+), Zn(2+) ion release from Activ GP sealer (32.57 ± 5.0, 1.57 ± 0.22 and 8.20 ± 1.74 μg mL(-1), respectively). In SEM analysis, the loss of matrix was evident and the filler particles were more distinguishable in all groups. CONCLUSIONS The setting time of all sealers was in accordance with ANSI/ADAs requirements. Activ GP did not fulfill ANSI/ADAs protocols regarding radiopacity, dimensional alteration and solubility. GuttaFlow was the only sealer that conformed to the Specification 57 in all tests. SEM analysis revealed that the surfaces of all sealers had micromorphological changes after the solubility test.


Journal of Endodontics | 2012

Root and root canal morphology of four-rooted maxillary second molars: a micro-computed tomography study.

Marco Aurélio Versiani; Jesus Djalma Pécora; Manoel Damião Sousa-Neto

INTRODUCTION This study examined the anatomy of 4-rooted maxillary second molars by using micro-computed tomography. METHODS Twenty-five 4-rooted maxillary second molars were scanned to evaluate the size and curvature of the roots; the distance and spatial configuration between some anatomical landmarks; the number of root canals and the position of apical foramina; the occurrence of fusion of roots and enamel pearls; the configuration of the canal at the apical third; the cross-sectional appearance, the volume, and surface area of the root canals. Data were compared by using analysis of variance post hoc Tukey test (α = 0.05). RESULTS The specimens were classified as types I (n = 16), II (n = 7), and III (n = 2). The size of the roots was similar (P > .05), and most of them presented straight with 1 canal, except the mesiobuccal that showed 2 canals in 24% of the samples. The configuration of the pulp chamber was mostly irregular quadrilateral-shaped. The lowest mean distance of the orifices was observed between the buccal roots (P < .05). Accessory canals were present mostly in the apical third. Location of the apical foramina varied considerably. Fusion of roots and enamel pearls occurred in 44% and 8% of the samples, respectively. Mean distance from the pulp chamber floor to the furcation was 2.15 ± 0.57 mm. No statistical differences were found in the bi-dimensional and 3-dimensional analyses (P > .05). CONCLUSIONS All analyzed parameters showed differences between roots, except for the length of the roots, the configuration of the canals at the apical third, cross-sectional appearance, volume, and surface area of the canals.


Journal of Endodontics | 2015

Micro-computed Tomographic Assessment on the Effect of ProTaper Next and Twisted File Adaptive Systems on Dentinal Cracks.

Gustavo De-Deus; Felipe Gonçalves Belladonna; Erick Miranda Souza; Emmanuel João Nogueira Leal Silva; Aline de Almeida Neves; Haimon Diniz Lopes Alves; R.T. Lopes; Marco Aurélio Versiani

INTRODUCTION The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and Twisted File Adaptive (TFA; SybronEndo, Orange, CA) systems through micro-computed tomographic analysis. METHODS Twenty moderately curved mesial roots of mandibular molars presenting a type II Vertucci canal configuration were randomly assigned to 2 experimental groups (n = 10) according to the system used for the root canal preparation: PTN or TFA systems. The specimens were scanned through high-resolution micro-computed tomographic imaging before and after root canal preparation. Afterward, pre- and postoperative cross-sectional images of the mesial roots (N = 25,820) were screened to identify the presence of dentinal defects. RESULTS Dentinal microcracks were observed in 38.72% (n = 5150) and 30.27% (n = 3790) of the cross-sectional images in the PTN and TFA groups, respectively. All dentinal defects identified in the postoperative scans were already present in the corresponding preoperative images. CONCLUSIONS Root canal preparation with PTN and TFA systems did not induce the formation of new dentinal microcracks.


International Endodontic Journal | 2011

The anatomy of two-rooted mandibular canines determined using micro-computed tomography

Marco Aurélio Versiani; Jesus Djalma Pécora; Manoel Damião Sousa-Neto

AIM To investigate the internal and external anatomy of extracted human mandibular canines with two roots and two distinct canals using micro-computed tomography (μCT). METHODOLOGY Fourteen two-rooted human mandibular canines were scanned using a high-resolution μCT system (SkyScan 1174v2; SkyScan N.V., Kontich, Belgium). The images were processed to evaluate the size of the roots, the furcation regions, the presence of accessory canals, the mean distances between several anatomical landmarks, the position of the apical foramina, the direction of root curvatures, the cross-sectional appearances (SMI index), the volume and surface areas of the root canals. RESULTS Root bifurcation was located in both apical (44%, n = 6) and middle (58%, n = 8) thirds of the root. The size of the buccal and lingual roots was similar in 29% of the sample. From a buccal view, no curvature towards the lingual or buccal direction occurred in either roots. From a proximal view, no straight lingual root occurred. In both views, S-shaped roots were found in 21% of the specimens. Location of the apical foramen varied considerably, tending to the mesio-buccal aspect of both roots. Lateral and furcation canals were observed mostly in the cervical third in 29% and 65% of the sample, respectively. The structure model index (SMI) index ranged from 1.87 to 3.86, with a mean value of 2.93 ± 0.46. Mean volume and area of the root canals were 11.52 ± 3.44 mm(3) and 71.16 ± 11.83 mm(2), respectively. CONCLUSIONS The evaluation of two-rooted mandibular canines revealed that bifurcations occurred in the apical and middle third. S-shaped roots were found in 21% of the specimens. Mean volume, surface area and SMI index of the root canals were 11.52 mm(3), 71.16 mm(2) and 2.93, respectively.


Journal of Endodontics | 2013

Comparison of the Cleaning Efficacy of Self-Adjusting File and Rotary Systems in the Apical Third of Oval-shaped Canals

Marcus Vinícius de Melo Ribeiro; Yara Terezinha Silva-Sousa; Marco Aurélio Versiani; Alessandro Lamira; Liviu Steier; Jesus Djalma Pécora; Manoel Damião Sousa-Neto

INTRODUCTION Cleaning and shaping of root canals are essential steps for the success of endodontic therapy. The purpose of this study was to evaluate the tissue debridement efficacy of the self-adjusting file (SAF) protocol in the apical third of oval-shaped canals of mandibular incisors in comparison with a nickel-titanium rotary system preparation. METHODS Twenty-six single-rooted human mandibular incisor teeth were selected and assigned to a control (n = 4) and 2 experimental groups (n = 11) according to 1 of 2 instrumentation techniques, SAF and nickel-titanium rotary systems. After root canal preparation, the apical thirds of the specimens were submitted to histologic processing and analyzed by optical microscopy regarding the percentage of debris and uninstrumented root canal walls. The data were statistically compared by using unpaired t test with Welchs correction, and the level of significance was set at 5%. RESULTS The percentage of remaining debris and uninstrumented canal perimeter was significantly lower in SAF group (2.18 ± 2.71 and 12.33 ± 7.85, respectively) than in rotary group (13.11 ± 12.98 and 53.54 ± 15.95, respectively) (P < .05). In the SAF group most of specimens were completely free of debris, whereas in the rotary group 53% of the canals presented debris. CONCLUSIONS SAF had significantly more contact to the dentin walls and removed more debris than rotary instrumentation in the apical third of mandibular incisors.


Journal of Endodontics | 2015

Accumulated hard tissue debris produced during reciprocating and rotary nickel-titanium canal preparation.

Gustavo De-Deus; Juliana Marins; Emmanuel João Nogueira Leal Silva; Erick Miranda Souza; Felipe Gonçalves Belladonna; Claudia Reis; A.S. Machado; R.T. Lopes; Marco Aurélio Versiani; Sidnei Paciornik; Aline de Almeida Neves

INTRODUCTION This study compared the amount of hard tissue debris produced after different apical enlargement with single-file reciprocating systems (WaveOne [Dentsply Maillefer, Baillaigues, Switzerland] and Reciproc [VDW, Munich, Germany]) and a conventional multifile rotary system (BioRaCe [FKG Dentaire, La-Chaux-de-Fonds, Switzerland]) using micro-computed tomographic imaging. METHODS Thirty moderately curved mesial roots of mandibular molars presenting 2 independent root canals were selected and scanned at an isotropic resolution of 14.16 μm. The sample was assigned to 3 groups (n = 10) with respect to the root length and degree of curvature of the mesial root according to the system used for the root canal preparation: Reciproc, WaveOne, and BioRaCe. Second and third scans were taken after the root canals were prepared up to ISO sizes 25 and 40, respectively. The matched images of the mesial canals, before and after preparation, were examined from the furcation level to the apex to evaluate the amount of hard tissue debris (%). Data were statistically compared using a general linear model for repeated-measures with a significance level set at 5%. RESULTS Instrumentation systems per se did not influence the amount of hard tissue accumulation (P > .05), whereas a significant reduction in the percentage of hard tissue debris was observed after sequential enlargement in all groups (P < .05). CONCLUSIONS None of the systems yielded root canals completely free from packed hard tissue debris. The increased final apical size resulted in significantly less debris accumulation for both reciprocating and rotary systems.

Collaboration


Dive into the Marco Aurélio Versiani's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gustavo De-Deus

Federal Fluminense University

View shared research outputs
Top Co-Authors

Avatar

Erick Miranda Souza

Federal University of Maranhão

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

R.T. Lopes

Federal University of Rio de Janeiro

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Graziela Bianchi Leoni

Universidade de Ribeirão Preto

View shared research outputs
Researchain Logo
Decentralizing Knowledge