Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ronald Ordinola-Zapata is active.

Publication


Featured researches published by Ronald Ordinola-Zapata.


Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 2009

Depth and percentage of penetration of endodontic sealers into dentinal tubules after root canal obturation using a lateral compaction technique: A confocal laser scanning microscopy study

Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Márcia Sirlene Zardin Graeff; Aldo del Carpio Perochena; Rodrigo Ricci Vivan; Éricson Janolio de Camargo; Roberto Brandão Garcia; Norberti Bernardineli; James L. Gutmann; Ivaldo Gomes de Moraes

OBJECTIVE The aim was to compare the percentage and depth of sealer penetration into dentinal tubules during obturation using Sealer 26, GuttaFlow, or Sealapex in root canals filled with the lateral compaction technique. STUDY DESIGN Thirty root canals filled with the lateral compaction technique using GuttaFlow (n = 10), Sealapex (n = 10), or Sealer 26 (n = 10) were analyzed using confocal microscopy. The teeth were sectioned at 3 and 5 mm from the apex, and statistical analyses was performed using analysis of variance-Tukey test (P < .05). RESULTS Sealapex showed the deepest sealer penetration at both levels evaluated (P < .05). No statistically significance was found between Sealer 26 and GuttaFlow at the 3 mm and 5 mm levels. No statistical significance was found in the percentage of penetration around the root canal wall among the 3 sealers evaluated at both levels. CONCLUSIONS Although Sealapex displayed deeper penetration into the dentinal tubules there was no difference in the percentage of adaptation to the root canal walls among the 3 sealers evaluated.


Journal of Endodontics | 2011

Biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin.

Aldo del Carpio-Perochena; Clovis Monteiro Bramante; Marco Antonio Hungaro Duarte; Marcelo Haas Villas-Bôas; Márcia Sirlene Zardin Graeff; Norberti Bernardineli; Flaviana Bombarda de Andrade; Ronald Ordinola-Zapata

INTRODUCTION The aim of this study was to evaluate the biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin. METHODS One hundred twenty bovine dentin specimens were infected intraorally by using a removable orthodontic device. Thirty samples were used for each irrigant solution: 2% chlorhexidine and 1%, 2.5%, and 5.25% sodium hypochlorite (NaOCl). The solutions were used for 5, 15, and 30 minutes and at 2 experimental volumes, 500 μL and 1 mL. The samples were stained by using acridine orange dye before and after the experiments and evaluated by using a confocal microscope. The percentage of biofilm, isolated cells, and noncolonized dentin was measured by using a grid system. Differences in the reduction or increase of the studied parameters were assessed by using nonparametric methods (P < .05). RESULTS The higher values of biofilm dissolution and noncolonized dentin were found in the 30-minute NaOCl group and in the 5-minute and 15-minute groups of 5.25% NaOCL. The use of 2% chlorhexidine solution did not improve the biofilm dissolution or increase the cleaning of the dentin in comparison with the NaOCl solutions (P < .05). CONCLUSIONS Two percent chlorhexidine does not dissolve the biofilms. Thirty minutes of NaOCl are necessary to have higher values of biofilm dissolution and to increase the cleaning of the dentin independently of the concentration in comparison with the 5-minute and 15-minute contact times.


International Endodontic Journal | 2012

Antimicrobial effect of endodontic solutions used as final irrigants on a dentine biofilm model

Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Márcia Sirlene Zardin Graeff; I. Gomes de Moraes; Marina Angélica Marciano; Marco Antonio Hungaro Duarte

AIM To evaluate the residual biovolume of live bacterial cells, the mean biofilm thickness and the substratum coverage found in mixed biofilms treated with different endodontic irrigant solutions. METHODOLOGY Twenty-five bovine dentine specimens were infected intraorally using a removable orthodontic device. Five samples were used for each irrigant solution: 2% chlorhexidine, 1% sodium hypochlorite (NaOCl), 10% citric acid, 17% EDTA and distilled water. The solutions were used for 5 min. The samples were stained using the Live/Dead technique and evaluated using a confocal microscope. Differences in the amount of total biovolume (μm(3)), number of surviving cells (μm(3)), mean biofilm thickness (μm) and substratum coverage (%) of the treated biofilms were determined using nonparametric statistical tests (P < 0.05). RESULTS Similar values of biovolume total, biovolume of live subpopulations and substratum coverage were found in 2% chlorhexidine, 10% citric acid, 17% EDTA and distilled water-treated biofilms (P > 0.05). The lower values of the studied parameters were found in 1% NaOCl-treated dentine (P < 0.05) with the exception of the mean biofilm height criteria that did not reveal significant differences amongst the irrigant solutions (P > 0.05). CONCLUSIONS One per cent sodium hypochlorite was the only irrigant that had a significant effect on biofilm viability and architecture.


International Endodontic Journal | 2014

Influence of powder‐to‐water ratio on radiopacity, setting time, pH, calcium ion release and a micro‐CT volumetric solubility of white mineral trioxide aggregate

Thais Cristina Pereira; Marco Antonio Hungaro Duarte; Ronald Ordinola-Zapata; Marina Angélica Marciano; Clovis Monteiro Bramante; Norberti Bernardineli

AIM To evaluate the radiopacity, setting time, pH level, calcium ion release and solubility of white mineral trioxide aggregate (MTA; Angelus, Londrina, Pr, Brazil) with different powder-to-water ratios. METHODOLOGY Three MTA groups were prepared using 4 : 1, 3 : 1 and 2 : 1 powder-to-water ratios. For the radiopacity analysis, the 10 × 1 mm specimens were arranged on occlusal films with a cylinder of dentine and an aluminium stepwedge. The digitized radiographs were evaluated with Digora 1.51 software to determine the radiographic density. The setting time test was performed according to the American Society for Testing and Materials 266/08 standard specifications, but the specimens were made according to International Organization for Standardization 6876:2001. Thirty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH level and calcium ion release (atomic absorption spectrophotometer) at 3, 24, 72 and 168 h. In the solubility test, the root-end fillings of 30 acrylic teeth were scanned twice by a Micro-CT, before and after immersion in ultrapure water for 168 h. Digital data were reconstructed, and the volume (mm(3) ) of the samples was obtained using CTan software (CTan v1.11.10.0, SkyScan). The data were statistically analysed by the anova, Tukey, Kruskal-Wallis and Dunns tests. RESULTS The radiopacity was higher (P < 0.05) when the 4 : 1 proportion was utilized. The setting time was longer, and the pH level and calcium ion release were higher (P < 0.05) with a greater volume of water. The group with more water (2 : 1) had significantly (P < 0.05) more material volume loss (6.46%) compared with the other groups. CONCLUSIONS The ratio of powder/water significantly interfered with the physical and chemical properties of white MTA Angelus.


Journal of Endodontics | 2010

Influence of Calcium Hydroxide Association on the Physical Properties of AH Plus

Marco Antonio Hungaro Duarte; Ronald Ordinola-Zapata; Ricardo Affonso Bernardes; Clovis Monteiro Bramante; Norberti Bernardineli; Roberto Brandão Garcia; Ivaldo Gomes de Moraes

INTRODUCTION This study evaluated in vitro the radiopacity, setting time, flow, film thickness, solubility, and dimensional changes of AH Plus sealer pure (Dentsply De Trey Gmbh, Konstanz, Germany) and containing 5% and 10% of calcium hydroxide. METHODS The study was performed according to the requirements of the ISO 6876:2001 standard and the American National Standards Institute/American Dental Association (ANSI/ADA)s Specification No. 57. The following tests were performed: setting time, flow, film thickness, dimensional stability, radiopacity, and solubility. Data were analyzed statistically by analysis of variance and the Tukey tests with a significance level of 5%. RESULTS The addition of 5% or 10% calcium hydroxide to AH Plus sealer did not alter significantly the radiopacity or setting time values (p > 0.05). Adding 10% calcium hydroxide reduced the flow compared with pure AH Plus and AH Plus/5% calcium hydroxide. The addition of 5% and 10% calcium hydroxide increased the solubility and expansion of AH Plus. All materials presented expansion valued above those recommended by the ADA. The addition of calcium hydroxide to the sealer resulted in greater film thickness. CONCLUSIONS The addition of 5% calcium hydroxide did not affect most physical properties of AH Plus sealer.


Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 2009

Evaluation of the radiopacity of some commercial and experimental root-end filling materials

Rodrigo Ricci Vivan; Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Norberti Bernardineli; Roberto Brandão Garcia; Marco Antonio Hungaro Duarte; Ivaldo Gomes de Moraes

OBJECTIVE The aim of the present study was to evaluate the radiopacity of 5 root end filling materials (white MTA Angelus, MTA Bio, light-cured MTA, Sealepox RP, and Portland cement clinker with bismuth oxide and calcium sulfate). METHOD Five specimens, 10 mm in diameter and 1 mm in thickness according to specification ISO 6876:2001 were fabricated from each material and radiographed using Insigth occlusal films close to a graduated aluminum step-wedge (2 to 16 mm in thickness). Radiographs were digitized and compared to the aluminum step-wedge. The radiographic density data were converted into millimeters of aluminum (mm Al), using the Digora 1.51 software. Results were evaluated statistically using the analysis of variance (ANOVA) followed by Tukey test. The level of significance was set at 5% (P <.05%). RESULTS Radiopacity values ranged from 1.21 mm Al (light-cured MTA) to 6.45 mm Al (MTA Angelus). Comparison between materials showed significant difference (P < .05) between MTA Angelus and all other materials, between Sealepox RP and MTA Bio, and between light-cured MTA and Portland cement clinker. Light-cured MTA was significantly less radiopaque than all other materials. No significant difference (P > .05) was found between MTA Bio and Portland cement clinker. CONCLUSIONS All retrograde filling materials evaluated showed greater radiopacity than dentin. All the materials, except light-cured MTA met the minimum radiopacity standards of 3 mm Al recognized by the ISO 6876:2001 and ADA n.57.


International Endodontic Journal | 2014

Biofilm removal by 6% sodium hypochlorite activated by different irrigation techniques

Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Raydolfo M. Aprecio; R. Handysides; David E. Jaramillo

AIM To compare the removal of biofilm utilizing four irrigation techniques on a bovine root canal model. METHODOLOGY Fifty dentine specimens (2 × 2 mm) were infected with biofilm. The samples were then adapted to previously created cavities in the bovine model. The root canals were irrigated twice with 2 mL of 6% sodium hypochlorite for 2 min (4 min total). Following initial irrigation, the different treatment modalities were introduced for 60 s (3 × 20 s intervals). The evaluated techniques were needle irrigation, Endoactivator (Dentsply Tulsa Dental, Tulsa, OK, USA), passive ultrasonic irrigation and laser-activated irrigation (photon-induced photoacoustic streaming). The controls were irrigated with distilled water and conventional needle irrigation. Subsequently, the dentine samples were separated from the model and analysed using a scanning electron microscope (SEM). Fifteen operative fields were scanned per block, and SEM pictures were captured. Two calibrated evaluators examined the images and collected data using a four-degree scale. Nonparametric tests were used to evaluate for statistical significance amongst the groups. RESULTS The group undergoing laser-activated irrigation using photon-induced photoacoustic streaming exhibited the most favourable results in the removal of biofilm. Passive ultrasonic irrigation scores were significantly lower than both the Endoactivator and needle irrigation scores. Sonic and needle irrigation were not significantly different. The least favourable results were found in the control group. CONCLUSIONS Laser activation of 6% sodium hypochlorite significantly improved the cleaning of biofilm-infected dentine followed by passive ultrasonic irrigation.


Journal of Endodontics | 2013

Antimicrobial activity of triantibiotic paste, 2% chlorhexidine gel, and calcium hydroxide on an intraoral-infected dentin biofilm model.

Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Paloma Gagliardi Minotti; Roberto Brandão Garcia; Norberti Bernardineli; David E. Jaramillo; Marco Antonio Hungaro Duarte

INTRODUCTION The purpose of this study was to evaluate the antimicrobial activity of calcium hydroxide, 2% chlorhexidine gel, and triantibiotic paste (ie, metronidazole, minocycline, and ciprofloxacin) by using an intraorally infected dentin biofilm model. METHODS Forty bovine dentin specimens were infected intraorally using a removable orthodontic device in order to induce the biofilm colonization of the dentin. Then, the samples were treated with the medications for 7 days. Saline solution was used as the control. Two evaluations were performed: immediately after the elimination of the medication and after incubation in brain-heart infusion medium for 24 hours. The Live/Dead technique (Invitrogen, Eugene, OR) and a confocal microscope were used to obtain the percentage of live cells. Nonparametric statistical tests were performed to show differences in the percentage of live cells among the groups (P < .05). RESULTS Calcium hydroxide and 2% chlorhexidine gel did not show statistical differences in the immediate evaluation. However, after application of the brain-heart infusion medium for 24 hours, 2% gel chlorhexidine showed a statistically lesser percentage of live cells in comparison with calcium hydroxide. The triantibiotic paste significantly showed a lower percentage of live cells in comparison with the 2% chlorhexidine gel and calcium hydroxide groups in the immediate and secondary (after 24 hours) evaluations. CONCLUSIONS The triantibiotic paste was most effective at killing the bacteria in the biofilms on the intraorally infected dentin model in comparison with 2% chlorhexidine gel and calcium hydroxide.


International Endodontic Journal | 2011

Analysis of four gutta-percha techniques used to fill mesial root canals of mandibular molars

Marina Angélica Marciano; Ronald Ordinola-Zapata; T. V. R. N. Cunha; Marco Antonio Hungaro Duarte; Roberto Brandão Garcia; Clovis Monteiro Bramante; Norberti Bernardineli; Ivaldo Gomes de Moraes

AIM To compare the percentage of gutta-percha, sealer and voids and the influence of isthmuses in mesial root canals of mandibular molars filled with different techniques. METHODOLOGY Canals in 60 mesial roots of mandibular first molars were prepared with ProTaper instruments to size F2 (size 25, 0.08 taper) and filled using a single-cone, lateral compaction, System B or Thermafil techniques. An epoxy resin sealer was labelled with Rhodamine-B dye to allow analysis under a confocal microscope. The percentage of gutta-percha, sealer and area of voids was calculated at 2, 4 and 6 mm from the apex, using Image Tool 3.0 software. Statistical analysis was performed using nonparametric Kruskal-Wallis and Dunn tests (P < 0.05). The influence of isthmuses on the presence or absence of voids was evaluated using the Fisher test. RESULTS At the 2 mm level, the percentage of gutta-percha, sealer and voids was similar amongst the System B, lateral compaction and single-cone techniques. The single-cone technique revealed significantly less gutta-percha, more sealer and voids in comparison with the Thermafil technique at the 2 and 4 mm level (P < 0.05). The analysis of all sections (2, 4 and 6 mm) revealed that more gutta-percha and less sealer and voids were found in root canals filled with Thermafil and System B techniques (P < 0.05). The Fisher test revealed that the presence of isthmuses increased the occurrence of voids in the lateral compaction group only (P < 0.05). CONCLUSION Gutta-percha, sealer filled area and voids were dependent on the canal-filling technique. The presence of isthmuses may influence the quality of root filling.


Journal of Endodontics | 2011

Physical Properties and Interfacial Adaptation of Three Epoxy Resin–based Sealers

Marina Angélica Marciano; Bruno Martini Guimarães; Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Roberto Brandão Garcia; Norberti Bernardineli; Flaviana Bombarda de Andrade; Ivaldo Gomes de Moraes; Marco Antonio Hungaro Duarte

INTRODUCTION The aim of the study was to evaluate the radiopacity, solubility, flow, film thickness, setting time, and adaptation to the root canal walls of 3 epoxy resin-based sealers: AH Plus, Acroseal, and Adseal. METHODS Physical tests were performed following American National Standards Institute/American Dental Associations requirements. For interfacial adaptation analysis, 30 maxillary canines were shaped by using ProTaper instruments. The specimens were divided into 3 groups (n = 10): group 1, AH Plus; group 2, Acroseal; and group 3, Adseal. The sealers were mixed with rhodamine B dye, and the canals were filled by using the lateral compaction technique. The percentage of gaps and voids area was calculated at 2, 4, and 6 mm levels from the apex. Statistical evaluation was performed by using analysis of variance for physical analysis and nonparametric Kruskal-Wallis and Dunn tests for interfacial adaptation (P < .05). RESULTS No statistical differences were found for adaptation, percentage of voids, solubility, flow, and film thickness among the sealers (P > .05). AH Plus was significantly more radiopaque (P < .05). For the setting time, there were statistical differences among all the studied sealers (P < .05). CONCLUSIONS AH Plus, Acroseal, and Adseal presented similar root canal adaptation, solubility, flow, and film thickness. Statistical differences were found for radiopacity and setting time (P < .05).

Collaboration


Dive into the Ronald Ordinola-Zapata's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge