Mark O. Westerhaus
Pennsylvania State University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Mark O. Westerhaus.
Journal of Near Infrared Spectroscopy | 1997
John S. Shenk; Mark O. Westerhaus; Paolo Berzaghi
A new procedure (LOCAL) for local calibrations is presented. LOCAL selects spectra from a library of samples and computes a PLS calibration equation for each constituent of the sample. This study evaluated the performances of LOCAL on the prediction of ground corn grain and haylage using several different combinations of data transformations, wavelength segment reduction, number of PLS factors and samples used in calibration. LOCAL resulted in lower SEP values for all the constituents of corn and dry matter of haylage with improvements ranging between 6 to 13%. Global calibrations had only a small advantage over LOCAL (1–2%) in the prediction of acid detergent fibre and crude protein in haylage. The two most important variables controlling the accuracy of predictions were number of samples in the calibration and number of PLS factors in the solution. Best results were obtained using 150 to 225 samples and more than 20 PLS factors per calibration equation. The speed of the LOCAL procedure is 0.5–2 s per sample on a 90 MHz computer. With this speed and accuracy, LOCAL is now available for real-time routine operation on a Windows platform.
Journal of Near Infrared Spectroscopy | 2000
Paolo Berzaghi; John S. Shenk; Mark O. Westerhaus
This study evaluated the use of an algorithm (LOCAL) for local calibration using multi-product databases. Four different databases were used: forages (hay, corn silage, haylage, small grain silage and total mixed ration; n=2924), grain (barley, corn, oats and wheat; n=1464), meat (meat and bone meal, fish meal and poultry meal; n=693) and feed (bakery products, mixed feed, poultry feed and soya products; n=1518). One-tenth of the samples were selected for validation from each database. Predictions of validation samples using generic and specific global calibrations were compared to the predictions generated by LOCAL. Standard errors of prediction for LOCAL calibrations were always lower than those of generic global calibrations and similar to those of specific global calibrations. However, LOCAL predictions were further improved by using different settings for each constituent. The analysis of the samples selected by LOCAL showed that for heterogeneous products such as total mixed rations and corn silage, LOCAL optimised predictions by choosing samples from different products. LOCAL calibration was then used with one database (n=6599) comprising all the samples. Standard errors of prediction were similar to those obtained with the four different databases. LOCAL can accurately predict the composition of different products using multi-product databases. Routine analysis can be simplified by using LOCAL calibration combined with large databases. In addition, LOCAL can provide accurate predictions of spectra from remote standardised instrument without the operator identifying the sample.
Journal of Near Infrared Spectroscopy | 2000
Franklin E. Barton; John S. Shenk; Mark O. Westerhaus; D. B. Funk
A large data base of near infrared and protein data was used to examine the utility of a data base regression technique know as LOCAL in the ISI International software package. A total of 2203 samples of wheat from five classes with protein values by combustion analysis comprised the data base. One half of the samples came from hard red spring and hard red winter wheats. The number of samples in the individual classes ranged from 235 for Durum to 694 for hard red spring. These samples were collected over a five year period and represented wheat in commercial trade. Calibrations were determined for each class, the entire data base as a “global” calibration, a data base regression which selected appropriate samples for a unique calibration for each sample and the standard equations of NIR spectroscopy regulatory analysis. Results will be reported which show data base regression technique to be as good as specific calibrations by partial least squares regression for sub-classes of products and precise enough for use for regulatory purposes. The use of this data base regression technique over normal learning sets has other advantages, such as easier calibration update, easier transferability and the possibility to include authentication and classification as part of the model.
Nir News | 1993
John S. Shenk; Mark O. Westerhaus
Many standardisation methods were evaluated before the patented method was selected. We evaluated a method similar to piecewise direct calibration. The method worked very well on mathematically created wavelength shifts, baseline offsets and band pass changes. When actual instrument differences were evaluated, however, the coefficients in the standardisation models were unrealistically large. We concluded that higher order models were dependent on small spectral changes (on the order of sample rescan repeatability). We then concentrated on simple linear models and developed the method that was later patented. This method of standardisation is represented in Figure 2. The patented method was developed and optimised for Pacific Scientific 6250 monochromators. Although satisfactory for those instruments, the
Journal of Near Infrared Spectroscopy | 1996
A. Couillard; A. J. Turgeon; Mark O. Westerhaus; John S. Shenk
The use of near infrared (NIR) reflectance spectroscopy to evaluate soil properties has started to receive more attention in recent years. The technology is evolving and research on NIR spectroscopic analysis using natural state samples is increasing. There is no method available today, besides NIR spectroscopy, that could simultaneously evaluate physical and chemical properties of a soil sample without processing the sample and affecting the visual quality of the site. More samples can be scanned in their natural undisturbed form resulting in a variety of particle sizes. Research on the effect of scanning products with different particle sizes is essential. The differences in the particle size of the soil separates may lower the prediction accuracy of NIR spectroscopy. In this study, we evaluated the ability of NIR spectroscopy to predict soil separates from artificial soil samples. Feldspar and silica sands and silts, kaolinite and montmorillonite clays, and reed sedge and Canadian sphagnum peat moss organic matters were used as separates. They were scanned alone, and in different mixture percentages, from 400 to 2500 nm with a total of 116 samples. The absence of linearity in the binary mixtures, preventing accurate calibration, was noticed and required the development of a transformation model to generate new laboratory values from a laboratory weight scaling factor generated for each soil separate. The adjustment of the laboratory values improved the prediction accuracy of the mixtures. The coefficient of determination ranged from 0.95 to 0.99. The standard error of cross-validation ranged from 2.09 to 5.82%.
Nir News | 2010
Benoît Igne; Pierre Dardenne; David Honigs; J. Todd Kuenstner; Karl H. Norris; Zhenqi Shi; Mark O. Westerhaus
14 A s part of the many activities proposed to attendees of the International Diffuse Refl ectance Conference (IDRC) taking place biennially in Chambersburg, Pennsylvania, USA, the software shoot-out is always a great occasion to listen to and interact with experienced chemometricians presenting their approach to a common problem. This 2010 IDRC challenge asked participants to develop calibration models for three human blood constituents: haemoglobin, glucose and cholesterol. This biomedical challenge, a cutting edge research area for numerous laboratories throughout the world, was made possible by the help of Karl Norris and Dr J. Todd Kuenstner (Charleston Area Medical Center, West Virginia, USA) who generously donated the data. Blood samples were analysed during the period from 1990 to 1992 with a NIRSystems 6500 spectrometer (Foss NIRSystems, Laurel, MD, USA) equipped with a transmission amplifi er mounted in the sample transport accessory. The instrument was confi gured to a vertical light-path mode using a platform supplied by the manufacturer. This made it possible to use a simple sample presentation for either transmission or refl ection measurements. The sample cell was a 2 cm diameter stainless steel cylinder with a quartz window. For transmission measurements, 200 μL of whole blood was transferred from a pipette to the sample cell, providing a sample thickness of 0.6 mm. For refl ection measurements, the cell was fi lled to a sample thickness of at least 2 mm to provide a sample of infi nite thickness for the NIR spectral region. The empty cell was used as a reference for transmission measurements and a ceramic reference standard for refl ection measurements. Participants were provided with three data sets for each measurement geometry (calibration, validation and test). Reference measurements were available for calibration and validation sets only. Participants were to develop the best prediction models with the available data and send their predictions of the test set to the shootout chair prior to the beginning of the conference. Criteria for deciding winners included overall prediction statistics of the test sets (both refl ection and transmission), novelty and uniqueness of the approach, and clarity of the presentation. All spectra (refl ection and transmission) had 700 variables, from 1100 nm to 2498 nm, with a 2 nm interval. Table 1 describes calibration and validation sample statistics. The trained chemometrician would notice that calibration and validation sets were suspiciously similar in terms of their distributions. Both sets were actually created from the same data set (fresh blood) while spectra of the test sets were samples frozen for storage and thawed before analysis. This choice was made to test participants’ models for robustness. Figure 1 shows spectral data and score plot of all three sets for the transmission data. Because the data sets were primarily designed for the study of the ability of NIR spectroscopy to predict haemoglobin, only haemoglobin predictions on the test sets were considered when judging calibration model statistics. The approaches taken by the four participants are presented here.
Nir News | 2014
Mark O. Westerhaus
At the recent EAS Symposium held in Somerset, NJ, USA, Mark Westerhaus was presented with the EAS Award for Outstanding Achievements in Near Infrared Spectroscopy. Mark kindly agreed to let us publish his talk so we are delighted to reproduce it below. I think you will find it to be a very clear explanation of the reasons for various elements of old and new software treatments that many of us have used in the past. Congratulations on this well-deserved award Mark!! Ed.
Crop Science | 1991
John S. Shenk; Mark O. Westerhaus
Archive | 1986
John S. Shenk; Mark O. Westerhaus
Crop Science | 1991
John S. Shenk; Mark O. Westerhaus