Metrologia | 2012

Final report on EURAMET.L-K1.2: EURAMET comparison of gauge blocks by interferometry

Marko Katić; Vedran Mudronja

During the EURAMET TC-L meeting in Lisbon in October 2009 a key comparison of gauge blocks by interferometry between five laboratories was initiated by the Croatian National Laboratory for Length, in order to test the performance of new equipment and to support CMC submission. The final report describes the measurement of eight short gauge blocks, with central length as the measurand. Since preliminary results were not consistent, statistical analysis of the entire dataset indicated that one laboratory should be excluded from calculation of the KCRV. Furthermore, another laboratory was asked to increase their measurement uncertainty due to rounding of the measurand value. Final results show good overall agreement, with the entire set being statistically consistent according to Birge ratio criteria. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Metrologia | 2010

Final report for the period 2007–2009 on the CCL-K11 ongoing key comparison

Michael Matus; Kaj Nyholm; Alan A. Madej; J.E. Bernard; Jerzy Walczuk; Lucija Crepinšek Lipuš; Héctor A Castillo M; Rene Pichardo Vega; Karina Beatriz Bastida; María Griselda Mingolla; Igor Malinovski; Luiz Tarelho; Ricardo França; Ramiz Hamid; Ersoy Sahin; Marko Katić; Vedran Šimunović; Lennart Robertsson

Lasers from nine national metrology institutes (NMIs) were compared as part of the CCL-K11 ongoing key comparison, initiated by the 13th meeting of the Comite Consultative des Longeurs (CCL) in 2007. The absolute frequency of the f component of the R(127) 11–5 transition of molecular iodine was measured for these lasers following the technical protocol for CCL-K11. The results of these measurements are compiled in the present report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Transactions of Famena | 2014

REALIZATION OF THE HIGHEST LEVEL OF TRACEABILITY IN CROATIAN NATIONAL LABORATORY FOR LENGTH

Marko Katić; Vedran Mudronja; Vedran Šimunović


Precision Engineering-journal of The International Societies for Precision Engineering and Nanotechnology | 2017

Long term stability of silicon roughness standards

Gorana Baršić; Marko Katić; Vedran Šimunović


Lasers in Medical Science | 2017

The efficacy of photon-initiated photoacoustic streaming in the removal of calcium silicate-based filling remnants from the root canal after rotary retreatment

Mateja Suk; Ivona Bago; Marko Katić; Damir Šnjarić; Marija Šimundić Munitić; Ivica Anić


Archive | 2011

Ensuring measurement unity in the field of dimensional nanometrology

Gorana Baršić; Vedran Šimunović; Marko Katić


Metrologia | 2018

Metrological characteristics of newly developed reference Vickers hardness blocks for the high hardness range

Tamara Aleksandrov Fabijanić; Marko Katić; Febo Menelao


Archive | 2017

Evaluation of the efficacy of ProTaper Universal, Reciproc and Reciproc Blue in the removal of epoxy-resin based sealer from root canals – a micro-computed tomography study

Mateja Suk; Ivona Bago; Marko Katić; Ivica Anić


Macroscale, Recent Developments in Traceable Dimensional Measurements | 2017

Evaluation of measuring methods for the evaluation of Additive Manufacturing

Oelof Kruger; Gorana Baršić; Ana Pilipović; Marko Katić


Archive | 2016

Comparison of results obtained using Coordinate Measuring Machine, Computed Radiography and Computed Tomography

Marko Katić; Gorana Baršić; Morana Mihaljević

Collaboration


Dive into the Marko Katić's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael Matus

Bundesamt für Eich- und Vermessungswesen

View shared research outputs
Top Co-Authors

Avatar

Kaj Nyholm

University of Helsinki

View shared research outputs
Top Co-Authors

Avatar

Alan A. Madej

National Research Council

View shared research outputs
Researchain Logo
Decentralizing Knowledge