Markus S. Kuster
University of Western Australia
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Markus S. Kuster.
Medicine and Science in Sports and Exercise | 1999
Markus S. Kuster; Karl Grob; Maria Kuster; Graeme A. Wood; A. Gächter
PURPOSE It was the purpose of the present study to examine the possibility of increased muscle coordination after anterior cruciate ligament (ACL) reconstruction through the wearing of a compression sleeve. METHODS Thirty-six patients were studied who had undergone unilateral ACL reconstruction at least 12 months previously. All subjects were required to perform a 10-cm standing drop jump from an elevated platform onto a force plate, to land on one leg, and thereafter maintain a one-legged balance for 25 s. This task was repeated three times without and three times with an elastic compression sleeve worn on the reconstructed limb. For analysis, the task was partitioned into a landing phase (150 ms), an adjusting phase (10s), and a balancing phase (10s). The peak impact loadings were measured in each direction (Fx, Fy, and Fz) during landing, while force-time integrals (intFz, intFy, and intFz) and root mean square (RMS) error of these forces were calculated for the adjusting and balancing phases. The path length and RMS of the center of pressure coordinates (Ax and Ay) were obtained for the adjusting and balancing phases combined. RESULTS Drop landings with the bandage produced significantly larger (P < 0.001) peak ground reaction forces in the vertical and anteroposterior direction, suggesting increased subject confidence in their knee. Wearing the knee bandage also enabled the patients to reduce all measured parameters in the anteroposterior direction (rmsFx, intFx, rmsAx) during both the adjusting and balancing phases (P < 0.001 ). A significant reduction in the center of pressure path length further indicated an enhanced steadiness during the one-legged stance. CONCLUSIONS It was concluded that a compression sleeve improved the total integration of the balance control system and muscle coordination.
Journal of Orthopaedic Trauma | 2007
Karl Stoffel; Kai-Uwe Lorenz; Markus S. Kuster
Objective: We compared the biomechanical stability of bone-plate constructs using a compression plate (CP), an internal fixator (IF), and a combination plate (CP/IF). Methods: Standardized simulated shaft fractures with a segmental defect in composite bones (n = 60) and intraarticular distal femur fractures with a comminuted supracondylar zone in fresh frozen cadaveric femurs (n = 36) were stabilized by CP, IF, and CP/IF. Construct stiffness, plastic deformation, and fixation strength were measured under axial compression and torsion using a biaxial testing machine. Results: The experimental results indicate for the distal femur fracture model that IF has less loss of reduction by plastic deformation under axial load compared to CP (IF 61% of CP). Under torsion, the CP showed significantly (P < 0.05) decreased plastic deformation compared to the IF (CP 51% of IF). The combination (CP/IF) of the 2 fixation principles generally resulted in a higher load to failure under axial compression and torsion (145% failure load of CP and 118% of IF under axial compression, 88% of CP and 109% of IF under torsion). Results were similar between the 2 fracture models. Conclusions: Under compression, IF provides similar fixation in comminuted fractures and was better than the CP for avoiding loss of reduction, whereas under torsional loading, CP was more important for stiffness, plastic deformation, and load to failure than IF. However, combination (CP/IF) fixation seems advisable in intraarticular and extraarticular fractures of long bones with a metaphyseal comminution. These data may be utilized by surgeons to build a more specific treatment plan in patients with these fracture types.
Orthopedics | 2002
Markus S. Kuster; Gwidon Stachowiak
A complication of total knee arthroplasty (TKA) is fatigue-type wear, which can destroy a tibial inlay in <10 years. This deleterious wear mechanism occurs during cyclic loading if the yield stress of polyethylene is exceeded. Because increased stress on and within the polyethylene inlay is associated with increased wear, it is important to reduce the inlay stress by either activity restrictions or conformity changes of design. All stress parameters are more sensitive to conformity changes (eg, design changes) than to load changes (eg, activity restrictions). However, the reduction of stress on and within the polyethylene through increased conformity will increase the stress at the tibial fixation interfaces. An attempt was made to solve this problem with the introduction of mobile-bearing designs. Many mobile-bearing designs exist with good long-term results. One important difference among the various designs is the amount of flexion range with full conformity between the femoral component and the tibial inlay. Although a single radius design reduces polyethylene stress throughout the flexion range, it may be disadvantageous for a revision design to intraoperatively adapt to different degrees of constraint. Aseptic loosening and osteolysis due to small abrasive and adhesive wear particles have also been reported as a cause of failure. The design and material parameters affecting polyethylene wear in TKAs, as well as the potential detrimental effects of wear particle size, are the key issues in defining the life of a TKA.
Journal of Bone and Joint Surgery-british Volume | 2007
Benjamin O. Jeffcote; Rochelle L. Nicholls; A. Schirm; Markus S. Kuster
Achieving deep flexion after total knee replacement remains a challenge. In this study we compared the soft-tissue tension and tibiofemoral force in a mobile-bearing posterior cruciate ligament-sacrificing total knee replacement, using equal flexion and extension gaps, and with the gaps increased by 2 mm each. The tests were conducted during passive movement in five cadaver knees, and measurements of strain were made simultaneously in the collateral ligaments. The tibiofemoral force was measured using a customised mini-force plate in the tibial tray. Measurements of collateral ligament strain were not very sensitive to changes in the gap ratio, but tibiofemoral force measurements were. Tibiofemoral force was decreased by a mean of 40% (SD 10.7) after 90 degrees of knee flexion when the flexion gap was increased by 2 mm. Increasing the extension gap by 2 mm affected the force only in full extension. Because increasing the range of flexion after total knee replacement beyond 110 degrees is a widely-held goal, small increases in the flexion gap warrant further investigation.
Journal of Orthopaedic Trauma | 2004
Karl Stoffel; Gwidon Stachowiak; Thomas Forster; A. Gächter; Markus S. Kuster
Objective: To test the hypothesis that oblique screws at the ends of a plate provide increased strength of fixation as compared to standard screw insertion. Design: Biomechanical laboratory study in synthetic bone test medium. Methods: Narrow 4.5-mm stainless steel low-contoured dynamic compression plates were anchored with cortical screws to blocks of polyurethane foam. The fixation strength in cantilever bending (gap closing mode) and torsion was quantified using a material testing system. Different constructs were tested to investigate the effect of the screw orientation at the end of the plate (straight versus oblique at 30°), the plate, and bridging length as well as the number of screws. Results: An oblique screw at the plate end produced an increased strength of fixation in all tests; however, the difference was more significant in shorter plates and in constructs with no screw omission adjacent to the fracture site. Both longer plates and increased bridging length produced a significantly stronger construct able to withstand higher compression loads. Under torsional loading, the fixation strength was mainly dependent on the number of screws. Conclusions: The current data suggest that when using a conventional plating technique, plate length is the most important factor in withstanding forces in cantilever bending. With regard to resisting torsional load, the number of screws is the most important factor. Furthermore , oblique screws at the ends of a plate increase fixation strength.
Health and Quality of Life Outcomes | 2013
Johannes M. Giesinger; Markus S. Kuster; Henrik Behrend; Karlmeinrad Giesinger
BackgroundPatient-reported outcome measures have become a well-recognised part of outcome assessment in orthopaedic surgery. These questionnaires claim to measure joint-specific dimensions like pain, function in activities of daily living, joint awareness or stiffness. Interference of the patient’s psychological status with these orthopaedic questionnaires however may make accurate interpretation difficult.MethodsWe recruited 356 patients after unilateral, primary THA or TKA and performed a postal survey including the Brief Symptom Inventory (psychological distress measure), the Catastrophising Scale (from the Coping Strategies Questionnaire), the WOMAC score (Western Ontario and McMaster Universities Osteoarthritis Index) and the Forgotten Joint Score – 12 (FJS-12). Associations between the different questionnaires were determined calculating Pearson correlation coefficients. Two multiple linear regression models were used to investigate the impact of socio-demographic variables, clinical variables and of the psychological scales (BSI and Catastrophising Scale) separately for the WOMAC score and the FJS-12.ResultsWOMAC-Total score showed strong correlation to Catastrophising (r = 0.79), BSI-Somatisation (r = 0.63) and BSI-GSI (r = 0.54). The FJS-12 demonstrated modest to strong correlation with Catastrophising (r = −0.60), BSI-Somatisation (r = −0.49) and the BSI-GSI (Global Severity Index) (r = −0.44). BSI-GSI and Catastrophising explained 54.3% of variance in a multivariate regression model for the WOMAC score. The same two scales explained 30.0% of variance for the FJS-12.ConclusionsThere is a strong relationship between psychological status and orthopaedic outcome. The scale names of orthopaedic outcome measures suggest to measure specific dimensions like pain, stiffness, function or joint awareness. In fact they largely include patient’s psychological status indicating poor divergent validity.
Journal of Orthopaedic Trauma | 2012
Johannes Erhardt; Karl Stoffel; Jorg Kampshoff; Nicole Badur; Piers Yates; Markus S. Kuster
Objectives: Screw perforation of the humeral head in locking plate osteosynthesis occurs in up to 30% of cases. The current study compared different fixation possibilities (eg, number and position of screws) to reduce screw perforation in the humeral head. Methods: A humeral head fracture with a missing medial support was created in 30 fresh-frozen cadavers and fixed with a polyaxial locking plate (NCB PH; Zimmer, Warsaw, IN). The constructs were loaded with increasing force and the number of cycles until screw perforation was recorded. Four different fixation methods were tested: group 1 five screws with fixed angle, group 2 five screws in polyaxial position according to bone strength, group 3 three screws, and group 4 five screws with 1 as an inferomedial support screw. Results: More screws in the humeral head significantly increased the number of cycles before screw perforation. An inferomedial support screw further increased the number of cycles. Polyaxial screw placement compared with fixed-angle placement had no effect on the screw perforation phenomenon. Conclusions: We recommend to position an inferomedial support screw, and at least 5 screws in the head fragment, when using a locking plate in proximal humerus fractures with disrupted medial hinge.
Knee Surgery, Sports Traumatology, Arthroscopy | 2010
Alexander Rukavina; Gino M. M. J. Kerkhoffs; Philipp Schneider; Markus S. Kuster
This report describes a case of spontaneous recurrent hemarthrosis of the knee that presented 4 weeks after total knee arthroplasty. Femoral arteriography showed a false aneurysm of a branch of the inferior lateral geniculate artery. Therapeutic embolization of the arterial branch was performed using three platinum coils with good clinical result and good knee joint function. Hemarthrosis has not recurred since embolization.
Archives of Orthopaedic and Trauma Surgery | 2010
Jorg Kampshoff; Karl Stoffel; Piers Yates; Johannes Erhardt; Markus S. Kuster
IntroductionPeriprosthetic fractures after cemented hip replacement are a challenging problem to manage. Biomechanical studies have suggested the benefit of using locking screws for plate fixation, but there are concerns whether screws damage the cement mantle and promote crack propagation leading to construct failure.MethodIn this biomechanical study, different screw types were implanted into the cement mantle after pre-drilling holes of different sizes, in unicortical and bicortical configuration. The presence of cracks and the pull-out resistance of these screws were then evaluated.ResultsNo unicortical screw induced cracks. Screws with a shortened tip, smaller flutes and double threads were significantly better for pull-out resistance. Bicortical screws were associated with a risk of local cement mantle damage, but also with a significantly greater holding power. By increasing the drill diameter, the onset of cracks decreased, but so does the pull-out resistance.
Knee Surgery, Sports Traumatology, Arthroscopy | 2006
Rochelle L. Nicholls; Daniel J. Green; Markus S. Kuster
Patella complications are recognized sequelae of total knee arthroplasty (TKA). Disruption of blood flow to the patella and adjacent soft tissues during surgery may contribute to reduced viability of the bone and patella ligament tissue. The effect on genicular blood flow to the medial and lateral patella was compared for a medial (MA) and lateral arthrotomy (LA) during TKA. Laser Doppler flowmetry was used to measure both baseline and postarthrotomy flow in vivo for 16 primary TKA patients. Flow in the lateral patella was reduced approximately 20% for both MA and LA. Conversely, the use of MA resulted in substantial reduction in flow to the medial patella (53%) compared to the lateral approach (27%). A large standard deviation of scores was evident in all cases. Although there was a tendency for LA to disturb the patellar blood flow less, the difference was not significant. It was concluded that neither approach is superior regarding the blood flow preservation to the patella. Hence, a lateral approach might only have an advantage in knee joints that are likely to need a lateral release in combination with an MA—e.g., a valgus deformity or preoperative patella maltracking.