Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Martin J. Garland is active.

Publication


Featured researches published by Martin J. Garland.


Journal of Pharmacy and Bioallied Sciences | 2011

Mucoadhesive drug delivery systems

Rahamatullah Shaikh; Thakur Raghu Raj Singh; Martin J. Garland; A. David Woolfson; Ryan F. Donnelly

Mucoadhesion is commonly defined as the adhesion between two materials, at least one of which is a mucosal surface. Over the past few decades, mucosal drug delivery has received a great deal of attention. Mucoadhesive dosage forms may be designed to enable prolonged retention at the site of application, providing a controlled rate of drug release for improved therapeutic outcome. Application of dosage forms to mucosal surfaces may be of benefit to drug molecules not amenable to the oral route, such as those that undergo acid degradation or extensive first-pass metabolism. The mucoadhesive ability of a dosage form is dependent upon a variety of factors, including the nature of the mucosal tissue and the physicochemical properties of the polymeric formulation. This review article aims to provide an overview of the various aspects of mucoadhesion, mucoadhesive materials, factors affecting mucoadhesion, evaluating methods, and finally various mucoadhesive drug delivery systems (buccal, nasal, ocular, gastro, vaginal, and rectal).


Advanced Functional Materials | 2012

Hydrogel-forming microneedle arrays for enhanced transdermal drug delivery

Ryan F. Donnelly; Thakur Raghu Raj Singh; Martin J. Garland; Katarzyna Migalska; Rita Majithiya; Cian M. McCrudden; Prashant Laxman Kole; Tuan Mazlelaa Tuan Mahmood; Helen O. McCarthy; A. David Woolfson

Unique microneedle arrays prepared from crosslinked polymers, which contain no drug themselves, are described. They rapidly take up skin interstitial fluid upon skin insertion to form continuous, unblockable, hydrogel conduits from attached patch-type drug reservoirs to the dermal microcirculation. Importantly, such microneedles, which can be fabricated in a wide range of patch sizes and microneedle geometries, can be easily sterilized, resist hole closure while in place, and are removed completely intact from the skin. Delivery of macromolecules is no longer limited to what can be loaded into the microneedles themselves and transdermal drug delivery is now controlled by the crosslink density of the hydrogel system rather than the stratum corneum, while electrically modulated delivery is also a unique feature. This technology has the potential to overcome the limitations of conventional microneedle designs and greatly increase the range of the type of drug that is deliverable transdermally, with ensuing benefits for industry, healthcare providers and, ultimately, patients.


European Journal of Pharmaceutical Sciences | 2013

Microneedles for intradermal and transdermal drug delivery

Tuan Mazlelaa Tuan-Mahmood; Maeliosa McCrudden; Barbara M. Torrisi; Emma McAlister; Martin J. Garland; Thakur Raghu Raj Singh; Ryan F. Donnelly

The formidable barrier properties of the uppermost layer of the skin, the stratum corneum, impose significant limitations for successful systemic delivery of broad range of therapeutic molecules particularly macromolecules and genetic material. Microneedle (MN) has been proposed as a strategy to breach the stratum corneum barrier function in order to facilitate effective transport of molecules across the skin. This strategy involves use of micron sized needles fabricated of different materials and geometries to create transient aqueous conduits across the skin. MN, alone or with other enhancing strategies, has been demonstrated to dramatically enhance the skin permeability of numerous therapeutic molecules including biopharmaceuticals either in vitro, ex vivo or in vivo experiments. This suggested the promising use of MN technology for various possible clinical applications such as insulin delivery, transcutaneous immunisations and cutaneous gene delivery. MN has been proved as minimally invasive and painless in human subjects. This review article focuses on recent and future developments for MN technology including the latest type of MN design, challenges and strategies in MNs development as well as potential safety aspects based on comprehensive literature review pertaining to MN studies to date.


Journal of Controlled Release | 2010

Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution.

Ryan F. Donnelly; Martin J. Garland; Desmond I. J. Morrow; Katarzyna Migalska; Thakur Raghu Raj Singh; Rita Majithiya; A. David Woolfson

In this study, we used optical coherence tomography (OCT) to extensively investigate, for the first time, the effect that microneedle (MN) geometry (MN height, and MN interspacing) and force of application have upon penetration characteristics of soluble poly(methylvinylether-co-maleic anhydride, PMVE/MA) MN arrays into neonatal porcine skin in vitro. The results from OCT investigations were then used to design optimal and suboptimal MN-based drug delivery systems and evaluate their drug delivery profiles cross full thickness and dermatomed neonatal porcine skin in vitro. It was found that increasing the force used for MN application resulted in a significant increase in the depth of penetration achieved within neonatal porcine skin. For example, MN of 600μm height penetrated to a depth of 330μm when inserted at a force of 4.4N/array, while the penetration increased significantly to a depth of 520μm, when the force of application was increased to 16.4N/array. At an application force of 11.0N/array it was found that, in each case, increasing MN height from 350 to 600μm to 900μm led to a significant increase in the depth of MN penetration achieved. Moreover, alteration of MN interspacing had no effect upon depth of penetration achieved, at a constant MN height and force of application. With respect to MN dissolution, an approximate 34% reduction in MN height occurred in the first 15min, with only 17% of the MN height remaining after a 3-hour period. Across both skin models, there was a significantly greater cumulative amount of theophylline delivered after 24h from an MN array of 900μm height (292.23±16.77μg), in comparison to an MN array of 350μm height (242.62±14.81μg) (p<0.001). Employing full thickness skin significantly reduced drug permeation in both cases. Importantly, this study has highlighted the effect that MN geometry and application force have upon the depth of penetration into skin. While it has been shown that MN height has an important role in the extent of drug delivered across neonatal porcine skin from a soluble MN array, further studies to evaluate the full significance of MN geometry on MN mediated drug delivery are now underway. The successful use of OCT in this study could prove to be a key development for polymeric MN research, accelerating their commercial exploitation.


Future Medicinal Chemistry | 2009

Designing photosensitizers for photodynamic therapy: strategies, challenges and promising developments

Martin J. Garland; Corona M. Cassidy; David Woolfson; Ryan F. Donnelly

Photodynamic therapy (PDT) and photodynamic antimicrobial chemotherapy (PACT) are techniques that combine the effects of visible light irradiation with subsequent biochemical events that arise from the presence of a photosensitizing drug (possessing no dark toxicity) to cause destruction of selected cells. Despite its still widespread clinical use, Photofrin(®) has several drawbacks that limit its general clinical use. Consequently, there has been extensive research into the design of improved alternative photosensitizers aimed at overcoming these drawbacks. While there are many review articles on the subject of PDT and PACT, these have focused on the photosensitizers that have been used clinically, with little emphasis placed on how the chemical aspects of the molecule can affect their efficacy as PDT agents. Indeed, many of the PDT/PACT agents used clinically may not even be the most appropriate within a given class. As such, this review aims to provide a better understanding of the factors that have been investigated, while aiming at improving the efficacy of a molecule intended to be used as a photosensitizer. Recent publications, spanning the last 5 years, concerning the design, synthesis and clinical usage of photosensitizers for application in PDT and PACT are reviewed, including 5-aminolevulinic acid, porphyrins, chlorins, bacteriochlorins, texaphyrins, phthalocyanines and porphycenes. It has been shown that there are many important considerations when designing a potential PDT/PACT agent, including the influence of added groups on the lipophilicity of the molecule, the positioning and nature of these added groups within the molecule, the presence of a central metal ion and the number of charges that the molecule possesses. The extensive ongoing research within the field has led to the identification of a number of potential lead molecules for application in PDT/PACT. The development of the second-generation photosensitizers, possessing shorter periods of photosensitization, longer activation wavelengths and greater selectivity for diseased tissue provides hope for attaining the ideal photosensitizer that may help PDT and PACT move from laboratory investigation to clinical practice.


Pharmaceutical Research | 2011

Laser-engineered dissolving microneedle arrays for transdermal macromolecular drug delivery.

Katarzyna Migalska; Desmond I. J. Morrow; Martin J. Garland; Raj Singh Thakur; A. David Woolfson; Ryan F. Donnelly

ABSTRACTPurposeTo assess the feasibility of transdermal macromolecule delivery using novel laser-engineered dissolving microneedles (MNs) prepared from aqueous blends of 20% w/w poly(methylvinylether maleic anhydride) (PMVE/MA) in vitro and in vivo.MethodsMicromoulding was employed to prepare insulin-loaded MNs from aqueous blends of 20% w/w PMVE/MA using laser-engineered moulds. To investigate conformational changes in insulin loaded into MNs, circular dichroism spectra were obtained. In vitro drug release studies from MNs across neonatal porcine skin were performed using Franz diffusion cells. The in vivo effect of MNs was assessed by their percutaneous administration to diabetic rats and measurement of blood glucose levels.ResultsMNs loaded with insulin constituted exact counterparts of mould dimensions. Circular dichroism analysis showed that encapsulation of insulin within polymeric matrix did not lead to change in protein secondary structure. In vitro studies revealed significant enhancement in insulin transport across the neonatal porcine skin. Percutaneous administration of insulin-loaded MN arrays to rats resulted in a dose-dependent hypoglycaemic effect.ConclusionWe demonstrated the efficacy of MNs prepared from aqueous blends of PMVE/MA in transdermal delivery of insulin. We are currently investigating the fate of the delivered insulin in skin and MN-mediated delivery of other macromolecules.


Journal of Controlled Release | 2012

Dissolving polymeric microneedle arrays for electrically assisted transdermal drug delivery.

Martin J. Garland; Ester Caffarel–Salvador; Katarzyna Migalska; A. David Woolfson; Ryan F. Donnelly

It has recently been proposed that the combination of skin barrier impairment using microneedles (MNs) coupled with iontophoresis (ITP) may broaden the range of drugs suitable for transdermal delivery, as well as enabling the rate of delivery to be achieved with precise electronic control. However, no reports exist on the combination of ITP with in situ drug loaded polymeric MN delivery systems. Furthermore, although a number of studies have highlighted the importance of MN design for transdermal drug delivery enhancement, to date, there has been no systematic investigation of the influence of MN geometry on the performance of polymeric MN arrays which are designed to remain in contact with the skin during the period of drug delivery. As such, for the first time, this study reports on the effect of MN heigth and MN density upon the transdermal delivery of small hydrophilic compounds (theophylline, methylene blue, and fluorescein sodium) across neonatal porcine skin in vitro, with the optimised MN array design evaluated for its potential in the electrically faciliatated delivery of peptide (bovine insulin) and protein (fluorescein isothiocyanate-labelled bovine serum albumin (FTIC-BSA)) macromolecules. The results of the in vitro drug release investigations revealed that the extent of transdermal delivery was dependent upon the design of the MN array employed, whereby an increase in MN height and an increase in MN density led to an increase in the extent of transdermal drug delivery achieved 6h after MN application. Overall, the in vitro permeation studies revealed that the MN design containing 361 MNs/cm(2) of 600 μm height resulted in the greatest extent of transdermal drug delivery. As such, this design was evaluated for its potential in the MN mediated iontophoretic transdermal delivery. Whilst the combination of MN and ITP did not further enhance the extent of small molecular weight solute delivery, the extent of peptide/protein release was significantly enhanced when ITP was used in combination of the soluble PMVE/MA MN arrays. For example, the cumulative amount of insulin permeated across neonatal porcine skin at 6h was found to be approximately 150 μg (3.25%), 227 μg (4.85%) and 462 μg (9.87%) for ITP, MN, and MN/ITP delivery strategies, respectively. Similarly, the cumulative amount of FTIC-BSA delivered across neonatal porcine skin after a 6h period was found to be approximately 110 μg (4.53%) for MN alone and 326 μg (13.40%) for MN in combination with anodal ITP (p<0.001). As such, drug loaded soluble PMVE/MA MN arrays show promise for the electrically controlled transdermal delivery of biomacromolecules in a simple, one-step approach.


Journal of Pharmaceutical Sciences | 2013

Influence of array interspacing on the force required for successful microneedle skin penetration: theoretical and practical approaches.

Ololade Olatunji; Diganta Bhusan Das; Martin J. Garland; Luc Belaid; Ryan F. Donnelly

Insertion behaviour of microneedle (MN) arrays depends upon the mechanical properties of the skin and, MN geometry and distribution in an array. In addressing this issue, this paper studies MN array insertion mechanism into skin and provides a simple quantitative basis to relate the insertion force with distance between two MNs. The presented framework is based on drawing an analogy between a beam on an elastic foundation and mechanism of needle insertion, where insertion force is separated into different components. A theoretical analysis indicates that insertion force decreases as interspacing increases. For a specified skin type, insertion force decreased from 0.029 to 0.028 N/MN when interspacing at MN tip was increased from 50 μm (350 μm at MN base) to 150 μm (450 μm at MN base). However, dependence of insertion force seems to decrease as the interspacing is increased beyond 150 μm. To assess the validity of the proposed model, a series of experiments was carried out to determine the force required for skin insertion of MN. Experiments performed at insertion speed of 0.5 and 1.0 mm/s yielded insertion force values of 0.030 and 0.0216 N, respectively, for 30 μm interspacing at MN base (330 μm interspacing at tip) and 0.028 and 0.0214 N, respectively, for 600 μm interspacing at MN base (900 μm interspacing at tip). Results from theoretical analysis and finite element modelling agree well with experimental results, which show MN interspacing only begins to affect insertion force at low interspacing (<150 μm interspacing at MN base). This model provides a framework for optimising MN devices, and should aid development of suitable application method and determination of force for reliable insertion into skin.


Toxicology in Vitro | 2010

Effects of microneedle length, density, insertion time and multiple applications on human skin barrier function: Assessments by transepidermal water loss

Yasmine A. Gomaa; Desmond I. J. Morrow; Martin J. Garland; Ryan F. Donnelly; Labiba K. El-Khordagui; Victor M. Meidan

Microneedle (MN) arrays have attracted considerable attention in recent years due to their ability to facilitate effective transdermal drug delivery. Despite appreciable research, there is still debate about how different MN dimensions or application modes influence permeabilization. This study aimed to investigate this issue by taking transepidermal water-loss measurements of dermatomed human skin samples following the insertion of solid polymeric MNs. Insertions caused an initial sharp drop in barrier function followed by a slower incomplete recovery - a paradigm consistent with MN-generation of microchannels that subsequently contract due to skin elasticity. While 600 μm-long MNs were more skin-perturbing than 400 μm MNs, insertion of 1000 μm-long MNs caused a smaller initial drop in integrity followed by a degree of long term permeabilization. This is explainable by the longest needles compacting the tissue, which then decompresses over subsequent hours. Multiple insertions had a similar effect as increasing MN length. There was some evidence that increasing MN density suppressed the partial barrier recovery caused by tissue contraction. Leaving MNs embedded in skin seemed to reduce the initial post-insertion drop in barrier function. Our results suggest that this in vitro TEWL approach can be used to rapidly screen MN-effects on skin.


Photodiagnosis and Photodynamic Therapy | 2010

Microneedle-mediated intradermal nanoparticle delivery: Potential for enhanced local administration of hydrophobic pre-formed photosensitisers

Ryan F. Donnelly; Desmond I. J. Morrow; Francois Fay; Christopher J. Scott; Sharif Abdelghany; Raghu Raj Thakur Singh; Martin J. Garland; A. David Woolfson

INTRODUCTION To date, 5-aminolevulinic acid (ALA) has been the most widely used agent in topical photodynamic therapy (PDT). However, owing to the poor penetration of ALA into skin, ALA-PDT is inappropriate for difficult-to-treat deep skin neoplasias, such as nodular basal cell carcinoma. An alternative strategy to ALA-PDT is to use pre-formed photosensitisers, which can be activated at longer wavelengths, facilitating enhanced light penetration into skin. Owing to their relatively high molecular weights and often high lipophilicities, these compounds cannot be effectively administered topically. This study aimed to deliver a model hydrophobic dye, Nile red, into the skin using novel microneedle (MN) technology. MATERIALS AND METHODS Nile red was incorporated into poly-lactide-co-glycolic acid (PLGA) nanoparticles using an emulsion and salting-out process. Polymeric MN arrays were prepared from aqueous blends of the mucoadhesive copolymer Gantrez(®) AN-139 and tailored to contain 1.0mg of Nile red-loaded PLGA nanoparticles. Intradermal delivery of Nile red was determined in vitro. RESULTS Uniform 150nm diameter PLGA nanoparticles were prepared containing 3.87μg Nile red / mg of PLGA. Tissue penetration studies using excised porcine skin revealed that high tissue concentrations of Nile red were observed at 1.125mm (382.63ng cm(-3)) following MN delivery. CONCLUSION For the first time, polymeric microneedles (MN) have been employed to deliver a model lipophilic dye, Nile red, into excised porcine skin. Importantly, this is a one-step delivery strategy for the local delivery of highly hydrophobic agents, which overcomes many of the disadvantages of current delivery strategies.

Collaboration


Dive into the Martin J. Garland's collaboration.

Top Co-Authors

Avatar

Ryan F. Donnelly

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. David Woolfson

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Helen O. McCarthy

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar

Corona M. Cassidy

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Elizabeth Ryan

Queen's University Belfast

View shared research outputs
Researchain Logo
Decentralizing Knowledge