The New England Journal of Medicine | 2010

Rapid Molecular Detection of Tuberculosis and Rifampin Resistance

Catharina Boehme; Pamela Nabeta; Doris Hillemann; Mark P. Nicol; Shubhada Shenai; Fiorella Krapp; Jenny Allen; Rasim Tahirli; Robert Blakemore; Roxana Rustomjee; Ana Milovic; Martin Jones; David H. Persing; Sabine Ruesch-Gerdes; Eduardo Gotuzzo; Camilla Rodrigues; David Alland; Mark D. Perkins

BACKGROUND Global control of tuberculosis is hampered by slow, insensitive diagnostic methods, particularly for the detection of drug-resistant forms and in patients with human immunodeficiency virus infection. Early detection is essential to reduce the death rate and interrupt transmission, but the complexity and infrastructure needs of sensitive methods limit their accessibility and effect. METHODS We assessed the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), with fully integrated sample processing in 1730 patients with suspected drug-sensitive or multidrug-resistant pulmonary tuberculosis. Eligible patients in Peru, Azerbaijan, South Africa, and India provided three sputum specimens each. Two specimens were processed with N-acetyl-L-cysteine and sodium hydroxide before microscopy, solid and liquid culture, and the MTB/RIF test, and one specimen was used for direct testing with microscopy and the MTB/RIF test. RESULTS Among culture-positive patients, a single, direct MTB/RIF test identified 551 of 561 patients with smear-positive tuberculosis (98.2%) and 124 of 171 with smear-negative tuberculosis (72.5%). The test was specific in 604 of 609 patients without tuberculosis (99.2%). Among patients with smear-negative, culture-positive tuberculosis, the addition of a second MTB/RIF test increased sensitivity by 12.6 percentage points and a third by 5.1 percentage points, to a total of 90.2%. As compared with phenotypic drug-susceptibility testing, MTB/RIF testing correctly identified 200 of 205 patients (97.6%) with rifampin-resistant bacteria and 504 of 514 (98.1%) with rifampin-sensitive bacteria. Sequencing resolved all but two cases in favor of the MTB/RIF assay. CONCLUSIONS The MTB/RIF test provided sensitive detection of tuberculosis and rifampin resistance directly from untreated sputum in less than 2 hours with minimal hands-on time. (Funded by the Foundation for Innovative New Diagnostics.)


Journal of Clinical Microbiology | 2010

Rapid Detection of Mycobacterium tuberculosis and Rifampin Resistance by Use of On-Demand, Near-Patient Technology

Danica Helb; Martin Jones; Elizabeth Story; Catharina Boehme; Ellen Wallace; Ken Ho; JoAnn Kop; Michelle R. Owens; Richard Rodgers; Padmapriya P. Banada; Hassan Safi; Robert Blakemore; N. T. Ngoc Lan; Edward C. Jones-López; Michael H. Levi; Michele Burday; Irene Ayakaka; Roy D. Mugerwa; Bill McMillan; Emily S. Winn-Deen; Lee A. Christel; Peter Dailey; Mark D. Perkins; David Persing; David Alland

ABSTRACT Current nucleic acid amplification methods to detect Mycobacterium tuberculosis are complex, labor-intensive, and technically challenging. We developed and performed the first analysis of the Cepheid Gene Xpert Systems MTB/RIF assay, an integrated hands-free sputum-processing and real-time PCR system with rapid on-demand, near-patient technology, to simultaneously detect M. tuberculosis and rifampin resistance. Analytic tests of M. tuberculosis DNA demonstrated a limit of detection (LOD) of 4.5 genomes per reaction. Studies using sputum spiked with known numbers of M. tuberculosis CFU predicted a clinical LOD of 131 CFU/ml. Killing studies showed that the assays buffer decreased M. tuberculosis viability by at least 8 logs, substantially reducing biohazards. Tests of 23 different commonly occurring rifampin resistance mutations demonstrated that all 23 (100%) would be identified as rifampin resistant. An analysis of 20 nontuberculosis mycobacteria species confirmed high assay specificity. A small clinical validation study of 107 clinical sputum samples from suspected tuberculosis cases in Vietnam detected 29/29 (100%) smear-positive culture-positive cases and 33/39 (84.6%) or 38/53 (71.7%) smear-negative culture-positive cases, as determined by growth on solid medium or on both solid and liquid media, respectively. M. tuberculosis was not detected in 25/25 (100%) of the culture-negative samples. A study of 64 smear-positive culture-positive sputa from retreatment tuberculosis cases in Uganda detected 63/64 (98.4%) culture-positive cases and 9/9 (100%) cases of rifampin resistance. Rifampin resistance was excluded in 54/55 (98.2%) susceptible cases. Specificity rose to 100% after correcting for a conventional susceptibility test error. In conclusion, this highly sensitive and simple-to-use system can detect M. tuberculosis directly from sputum in less than 2 h.


Journal of Clinical Microbiology | 2010

Evaluation of the Analytical Performance of the Xpert MTB/RIF Assay

Robert Blakemore; Elizabeth Story; Danica Helb; JoAnn Kop; Padmapriya P. Banada; Michelle R. Owens; Soumitesh Chakravorty; Martin Jones; David Alland

ABSTRACT We performed the first studies of analytic sensitivity, analytic specificity, and dynamic range for the new Xpert MTB/RIF assay, a nucleic acid amplification-based diagnostic system that detects Mycobacterium tuberculosis and rifampin (RIF) resistance in under 2 h. The sensitivity of the assay was tested with 79 phylogenetically and geographically diverse M. tuberculosis isolates, including 42 drug-susceptible isolates and 37 RIF-resistant isolates containing 13 different rpoB mutations or mutation combinations. The specificity of the assay was tested with 89 nontuberculosis bacteria, fungi, and viruses. The Xpert MTB/RIF assay correctly identified all 79 M. tuberculosis isolates and correctly excluded all 89 nontuberculosis isolates. RIF resistance was correctly identified in all 37 resistant isolates and in none of the 42 susceptible isolates. Dynamic range was assessed by adding 102 to 107 CFU of M. tuberculosis into M. tuberculosis-negative sputum samples. The assay showed a log-linear relationship between cycle threshold and input CFU over the entire concentration range. Resistance detection in the presence of different mixtures of RIF-resistant and RIF-susceptible DNA was assessed. Resistance detection was dependent on the particular mutation and required between 65% and 100% mutant DNA to be present in the sample for 95% certainty of resistance detection. Finally, we studied whether assay specificity could be affected by cross-contaminating amplicons generated by the GenoType MTBDRplus assay. M. tuberculosis was not detected until at least 108 copies of an MTBDRplus amplicon were spiked into 1 ml of sputum, suggesting that false-positive results would be unlikely to occur.


American Journal of Respiratory and Critical Care Medicine | 2011

A Multisite Assessment of the Quantitative Capabilities of the Xpert MTB/RIF Assay

Robert Blakemore; Pamela Nabeta; Amy L. Davidow; Viral Vadwai; Rasim Tahirli; Vanisha Munsamy; Mark P. Nicol; Martin Jones; David H. Persing; Doris Hillemann; Sabine Ruesch-Gerdes; Felicity Leisegang; Carlos Zamudio; Camilla Rodrigues; Catharina Boehme; Mark D. Perkins; David Alland

RATIONALE The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterial burden is an important biomarker for disease severity, infection control risk, and response to therapy. OBJECTIVES Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. METHODS Xpert MTB/RIF results were compared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. MEASUREMENTS AND MAIN RESULTS Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r(s) = -0.77) and directly from sputum (r(s) =-0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r(s) = 0.68) and semiquantitative colony counts (r(s) = -0.56) was weaker than smear. Tests of paired same-patient sputum showed that high viscosity sputum samples contained ×32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier in microscopy. CONCLUSIONS Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.


Mbio | 2017

The new Xpert MTB/RIF ultra: Improving detection of Mycobacterium tuberculosis and resistance to Rifampin in an assay suitable for point-of-care testing

Soumitesh Chakravorty; Ann Marie Simmons; Mazhgan Rowneki; Heta Parmar; Yuan Cao; Jamie Ryan; Padmapriya P. Banada; Srinidhi Deshpande; Shubhada Shenai; Jennifer Glass; Barry Krieswirth; Samuel G. Schumacher; Pamela Nabeta; Nestani Tukvadze; Camilla Rodrigues; Alena Skrahina; Elisa Tagliani; Daniela Maria Cirillo; Amy L. Davidow; Claudia M. Denkinger; David H. Persing; Robert Kwiatkowski; Martin Jones; David Alland

ABSTRACT The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R.


PLOS ONE | 2016

A Novel Sample Processing Method for Rapid Detection of Tuberculosis in the Stool of Pediatric Patients Using the Xpert MTB/RIF Assay.

Padmapriya P. Banada; Uvistra Naidoo; Srinidhi Deshpande; Farina Karim; JoAnne L. Flynn; Melanie O’Malley; Martin Jones; Oliver Nanassy; Prakash Jeena; David Alland

Background Tuberculosis (TB) is difficult to diagnose in children using molecular tests, because children have difficulty providing respiratory samples. Stool could replace sputum for diagnostic TB testing if adequate sample processing techniques were available. Methods We developed a rapid method to process large volumes of stool for downstream testing by the Xpert MTB/RIF (Xpert) TB-detection assay. The method was tested and optimized on stool samples spiked with known numbers of M. tuberculosis colony forming units (CFU), and stools from M. tuberculosis-infected cynomolgus macaques (Macaca fascicularis). Performance was scored on number of positive Xpert tests, the cycle thresholds (Cts) of the Xpert sample-processing control (SPC), and the Cts of the M. tuberculosis-specific rpoB probes. The method was then validated on 20 confirmed TB cases and 20 controls in Durban, South Africa. Results The assay’s analytical limit of detection was 1,000 CFU/g of stool. As much as one gram of spiked stool could be tested without showing increased PCR inhibition. In analytical spiking experiments using human stool, 1g samples provided the best sensitivity compared to smaller amounts of sample. However, in Macaques with TB, 0.6g stool samples performed better than either 0.2g or 1.2g samples. Testing the stool of pediatric TB suspects and controls suggested an assay sensitivity of 85% (95% CI 0.6–0.9) and 84% (95% CI 0.6–0.96) for 0.6g and 1.2g stool samples, respectively, and a specificity of 100% (95% CI 0.77–1) and 94% (95% CI 0.7–0.99), respectively. Conclusion This novel approach may permit simple and rapid detection of TB using pediatric stool samples.


Journal of Clinical Microbiology | 2017

Detection of Isoniazid-, Fluoroquinolone-, Amikacin-, and Kanamycin-Resistant Tuberculosis in an Automated, Multiplexed 10-Color Assay Suitable for Point-of-Care Use

Soumitesh Chakravorty; Sandy S. Roh; Jennifer Glass; Laura E. Smith; Ann Marie Simmons; Kevin Patrick Lund; Sergey G. Lokhov; Xin Liu; Peng Xu; Guolong Zhang; Laura E. Via; Qingyu Shen; Xianglin Ruan; Xing Yuan; Hong Zhu Zhu; Ekaterina Viazovkina; Shubhada Shenai; Mazhgan Rowneki; Jong Seok Lee; Clifton E. Barry; Qian Gao; David H. Persing; Robert Kwiatkawoski; Martin Jones; David Alland

ABSTRACT Extensively drug-resistant (XDR) tuberculosis (TB) cannot be easily or quickly diagnosed. We developed a rapid, automated assay for the detection of XDR-TB plus resistance to the drug isoniazid (INH) for point-of-care use. Using a simple filter-based cartridge with an integrated sample processing function, the assay identified a wide selection of wild-type and mutant sequences associated with XDR-TB directly from sputum. Four new large-Stokes-shift fluorophores were developed. When these four Stokes-shift fluorophores were combined with six conventional fluorophores, 10-color probe detection in a single PCR tube was enabled. A new three-phase, double-nested PCR approach allowed robust melting temperature analysis with enhanced limits of detection (LODs). Finally, newly designed sloppy molecular beacons identified many different mutations using a small number of probes. The assay correctly distinguished wild-type sequences from 32 commonly occurring mutant sequences tested in gyrA, gyrB, katG, and rrs genes and the promoters of inhA and eis genes responsible for resistance to INH, the fluoroquinolone (FQ) drugs, amikacin (AMK), and kanamycin (KAN). The LOD was 300 CFU of Mycobacterium tuberculosis in 1 ml sputum. The rate of detection of heteroresistance by the assay was equivalent to that by Sanger sequencing. In a blind study of 24 clinical sputum samples, resistance mutations were detected in all targets with 100% sensitivity, with the specificity being 93.7 to 100%. Compared to the results of phenotypic susceptibility testing, the sensitivity of the assay was 75% for FQs and 100% each for INH, AMK, and KAN and the specificity was 100% for INH and FQ and 94% for AMK and KAN. Our approach could enable testing for XDR-TB in point-of-care settings, potentially identifying highly drug-resistant TB more quickly and simply than currently available methods.


Journal of Clinical Microbiology | 2017

Sensitive Detection of Francisella tularensis Directly from Whole Blood by Use of the GeneXpert System

Padmapriya P. Banada; Srinidhi Deshpande; Soumitesh Chakravorty; Riccardo Russo; James Occi; Gabriel Meister; Kelly J. Jones; Carl H. Gelhaus; Michelle W. Valderas; Martin Jones; Nancy Connell; David Alland

ABSTRACT Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection.


Journal of Clinical Microbiology | 2015

Improving the sensitivity of the Xpert® MTB/RIF assay on sputum pellets by decreasing the amount of added Sample Reagent: a laboratory and clinical evaluation

Nila J. Dharan; Danielle Amisano; Gerald Mboowa; Willy Ssengooba; Robert Blakemore; Rachel W. Kubiak; Derek T. Armstrong; Martin Jones; Yukari C. Manabe; Moses Joloba; Jerrold J. Ellner; Susan E. Dorman; David Alland

ABSTRACT The Xpert MTB/RIF (Xpert) assay permits rapid near-patient detection of Mycobacterium tuberculosis in sputum; however, the test sensitivity remains suboptimal in paucibacillary specimens that are negative for acid-fast bacilli using smear microscopy. Xpert testing includes dilution with sample reagent, and when processed sputum pellets are tested, the recommended sample reagent/pellet ratio is 3:1. We evaluated whether a decreased sample reagent/pellet ratio of 2:1 increased Xpert sensitivity compared to the recommended 3:1. The limit of detection was determined by inoculating serial dilutions of M. tuberculosis into sputum samples, preparing sputum pellets, and testing each pellet by Xpert at both sample reagent ratios. Processed sputum pellets obtained from M. tuberculosis culture-positive clinical specimens were also tested by Xpert at both ratios. Among spiked sputum pellets, the limit of detection was 1,478 CFU/ml (95% confidence interval [CI], 1,211 to 1,943) at a 3:1 ratio and decreased to 832 CFU/ml (95% CI, 671 to 1,134) at 2:1. The proportion of specimens in which M. tuberculosis was detected was greater at 2:1 than at 3:1 for almost all numbers of CFU/ml; this difference was most prominent at lower numbers of CFU/ml. Among 134 concentrated sputum pellets from the clinical study, the sensitivity of Xpert at 2:1 was greater than at 3:1 overall (80% versus 72%; P = 0.03) and for smear-negative specimens (67% versus 58%; P = 0.12). For Xpert testing of sputum pellets, using a lower sample reagent/pellet ratio increased M. tuberculosis detection, especially for paucibacillary specimens. Our study supports use of a 2:1 sample reagent/pellet dilution for Xpert testing of sputum pellets.


Journal of Clinical Microbiology | 2017

Rapid Detection of Bacillus anthracis Bloodstream Infections by Use of a Novel Assay in the GeneXpert System

Padmapriya P. Banada; Srinidhi Deshpande; Riccardo Russo; Eric Singleton; Darshini Shah; Bhavana Patel; Michele Burday; Ranie Koshy; Qing Wang; Martin Jones; Sergey G. Lokhov; Robert Kwiatkowski; David H. Persing; Nancy Connell; David Alland

ABSTRACT Bacillus anthracis is a tier 1 select agent with the potential to quickly cause severe disease. Rapid identification of this pathogen may accelerate treatment and reduce mortality in the event of a bioterrorism attack. We developed a rapid and sensitive assay to detect B. anthracis bacteremia using a system that is suitable for point-of-care testing. A filter-based cartridge that included both sample processing and PCR amplification functions was loaded with all reagents needed for sample processing and multiplex nested PCR. The assay limit of detection (LOD) and dynamic range were determined by spiking B. anthracis DNA into individual PCR mixtures and B. anthracis CFU into human blood. One-milliliter blood samples were added to the filter-based detection cartridge and tested for B. anthracis on a GeneXpert instrument. Assay specificity was determined by testing blood spiked with non-anthrax bacterial isolates or by testing blood samples drawn from patients with concurrent non-B. anthracis bacteremia or nonbacteremic controls. The assay LODs were 5 genome equivalents per reaction and 10 CFU/ml blood for both the B. anthracis Sterne and V1B strains. There was a 6-log10 dynamic range. Assay specificity was 100% for tests of non-B. anthracis bacterial isolates and patient blood samples. Assay time was less than 90 min. This automated system suitable for point-of-care detection rapidly identifies B. anthracis directly from blood with high sensitivity. This assay might lead to early detection and more rapid therapy in the event of a bioterrorism attack.

Collaboration


Dive into the Martin Jones's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shubhada Shenai

Rutgers Biomedical and Health Sciences

View shared research outputs
Top Co-Authors

Avatar

Catharina Boehme

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Mark D. Perkins

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Pamela Nabeta

Foundation for Innovative New Diagnostics

View shared research outputs
Researchain Logo
Decentralizing Knowledge