Massimo Lorenzi
City University London
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Massimo Lorenzi.
Biointerphases | 2015
Maurizio Santini; Manfredo Guilizzoni; Massimo Lorenzi; Plamen Atanassov; Enrico Marsili; Stephanie Fest-Santini; Pierangela Cristiani; Carlo Santoro
Power output limitation is one of the main concerns that need to be addressed for full-scale applications of the microbial fuel cell technology. Fouling and biofilm growth on the cathode of single chamber microbial fuel cells (SCMFC) affects their performance in long-term operation with wastewater. In this study, the authors report the power output and cathode polarization curves of a membraneless SCMFC, fed with raw primary wastewater and sodium acetate for over 6 months. At the end of the experiment, the whole cathode surface is analyzed through X-ray microcomputed tomography (microCT), scanning electron microscopy, and energy-dispersive X-ray spectroscopy (EDX) to characterize the fouling layer and the biofilm. EDX shows the distribution of Ca, Na, K, P, S, and other elements on the two faces of the cathode. Na-carbonates and Ca-carbonates are predominant on the air (outer) side and the water (inner) side, respectively. The three-dimensional reconstruction by X-ray microCT shows biofilm spots unevenly distributed above the Ca-carbonate layer on the inner (water) side of the cathode. These results indicate that carbonates layer, rather than biofilm, might lower the oxygen reduction reaction rate at the cathode during long-term SCMFC operation.
Review of Scientific Instruments | 2015
Maurizio Santini; Manfredo Guilizzoni; Stephanie Fest-Santini; Massimo Lorenzi
An experimental study about the anisotropic wetting behavior of a surface patterned with parallel grooves is presented as an application example of a novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography. Shape of glycerin droplets on such surface is investigated by X-ray micro computed tomography (microCT) acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution. The reconstructed drop volumes enable to estimate the exact volumes of the drops, their base contours, and 3D static contact angles, based on true cross-sections of the drop-surface couple. Droplet base contours are compared to approximate geometrical contour shapes proposed in the literature. Contact angles along slices parallel and perpendicular to the grooves direction are compared with each other. The effect of the sessile drop volume on the wetting behavior is discussed. The proposed technique, which is applicable for any structured surface, enables the direct measure of Wenzel ratio based on the microCT scan in the wetted region usually inapproachable by any others. Comparisons with simplified models are presented and congruence of results with respect to the minimum resolution needed is evaluated and commented.
UIT 2014 - 32nd Italian Union of Thermo-Fluid-Dynamics Heat Transfer Conference | 2014
Manfredo Guilizzoni; Maurizio Santini; Massimo Lorenzi; Viola Knisel; Stephanie Fest-Santini
Fuel cells are electrochemical power generation system which may achieve high energy efficiencies with environmentally friendly emissions. Among the different types, Proton Exchange Membrane fuel cells (PEMFC) seem at present one of the most promising choices. A very important component of a PEMFC is the gas diffusion layer (GDL), which has the primary role of managing water in the cell, allowing reactant gases transport to the catalyst layer while keeping the membrane correctly hydrated and preventing electrode flooding. Therefore, GDLs have to be porous and very hydrophobic. Carbon clothes or carbon papers coated with a hydrophobizing agent – typically a fluoropolymer – are used. Given the complex chemistry and morphology of the GDLs, wettability analyses on them present some critical issues when using the conventional contact angle measurement techniques. In this paper, the deposition of a drop on a GDL (produced using polytetrafluoroethylene-co-perfluoroalcoxy vinyl ether as the fluorinated polymer) was investigated by means of micro computed tomography (microCT) and numerical simulation. The microCT facility operational at the University of Bergamo was used to acquire a 3D tomography of a water drop deposed on a sample GDL. The reconstructed drop dataset allows thorough understanding of the real drop shape, of its contact area and contact line. The GDL dataset was used to create a realistic mesh for the numerical simulation of the drop deposition, which was performed using the OpenFOAM® interFOAM solver.
Journal of Physics: Conference Series | 2015
Nicholas Mitroglou; Massimo Lorenzi; Maurizio Santini; Manolis Gavaises; Dennis Assanis
X-ray computed tomography (CT) is well-known and widely used in the medical sector for diagnosis of various illnesses. The technique is based on the absorption (i.e. attenuation) of the ionising electromagnetic radiation by the object. The amount of energy to be absorbed depends on the density and its thickness; the transmitted radiation through the object is then compared to the incident radiation that leads to a reconstruction of attenuation coefficients versus spatial position in the object. Thus, the resulting three-dimensional slices of the object are used (a) to identify internal geometric features of objects, and (b) to distinguish between media of different densities, i.e. liquid and air/vapour. In this study, the geometry extraction capability has been applied on time-averaged cavitation pocket shapes, as well as, the capability of density differentiation measurements on Diesel fuel flows. Results appear promising and pose a challenge in providing quantitative measurements of cavitation vapour fraction inside an injection hole.
Review of Scientific Instruments | 2017
Massimo Lorenzi; Nicholas Mitroglou; Maurizio Santini; Manolis Gavaises
An experimental technique for the estimation of the temporal-averaged vapour volume fraction within high-speed cavitating flow orifices is presented. The scientific instrument is designed to employ X-ray micro computed tomography (microCT) as a quantitative 3D measuring technique applied to custom designed, large-scale, orifice-type flow channels made from Polyether-ether-ketone (PEEK). The attenuation of the ionising electromagnetic radiation by the fluid under examination depends on its local density; the transmitted radiation through the cavitation volume is compared to the incident radiation, and combination of radiographies from sufficient number of angles leads to the reconstruction of attenuation coefficients versus the spatial position. This results to a 3D volume fraction distribution measurement of the developing multiphase flow. The experimental results obtained are compared against the high speed shadowgraph visualisation images obtained in an optically transparent nozzle with identical injection geometry; comparison between the temporal mean image and the microCT reconstruction shows excellent agreement. At the same time, the real 3D internal channel geometry (possibly eroded) has been measured and compared to the nominal manufacturing CAD drawing of the test nozzle.
Journal of Physics: Conference Series | 2017
Maurizio Santini; Manfredo Guilizzoni; Stephanie Fest-Santini; Massimo Lorenzi
Highly hydrophobic surfaces have been intensively investigated in the last years because their properties may lead to very promising technological spillovers encompassing both everyday use and high-tech fields. Focusing on textiles, hydrophobic fabrics are of major interest for applications ranging from clothes to architecture to environment protection and energy conversion. Gas diffusion media - made by a gas diffusion layer (GDL) and a microporous layer (MPL) - for fuel cells are a good benchmark to develop techniques aimed at characterizing the wetting performances of engineered textiles. An experimental investigation was carried out about carbon-based, PTFE-treated GDLs with and without MPLs. Two samples (woven and woven-non-woven) were analysed before and after coating with a MPL. Their three-dimensional structure was reconstructed and analysed by computer-aided X-ray microtomography (CT). Static and dynamic wettability analyses were then carried out using a modified axisymmetric drop shape analysis technique. All the surfaces exhibited very high hydrophobicity, three of them near to a super-hydrophobic behavior. Water drop impacts were performed, evidencing different bouncing, sticking and fragmentation outcomes for which critical values of the Weber number were identified. Finally, a CT scan of a drop on a GDL was performed, confirming the Cassie-Baxter wetting state on such surface.
ILASS2017 - 28th European Conference on Liquid Atomization and Spray Systems | 2017
I.K. Karathanassis; Phoevos Koukouvinis; Massimo Lorenzi; Efstathios Kontolatis; Zhilong Li; Jin Wang; Nicholas Mitroglou; Manolis Gavaises
The present investigation illustrates the temporally-resolved, phase-contrast visualization of the cavitating flowwithin an enlarged injector replica conducted at the ANL Advanced Photon Source. The flow was captured through side-view, x-ray radiographies at 67890 frames per second with an exposure time of 347ns. The orifice employed for the experiments has an internal diameter of 1.5mm and length equal to 5mm. A parametric investigation was conducted considering various combinations of the Reynolds and cavitation numbers, which designate the extent of in-nozzle cavitation. Proper post-processing of the obtained radiographies enabled the extraction of information regarding the shape and dynamical behaviour of cavitating strings. The average string extent along with its standard deviation was calculated for the entire range of conditions examined (Re=18000-36000, CN=1.6-7.7). Furthermore, the effect of the prevailing flow conditions on quantities indicative of the string dynamic behaviour such as the break-up frequency and lifetime was characterized and the local velocity field in the string region was obtained.
Journal of Fluid Mechanics | 2017
Phoevos Koukouvinis; Nicholas Mitroglou; Manolis Gavaises; Massimo Lorenzi; Maurizio Santini
Experiments in Fluids | 2016
Nicholas Mitroglou; Massimo Lorenzi; Maurizio Santini; Manolis Gavaises
ILASS – Europe 2016: 27th Annual Conference on Liquid Atomization and Spray Systems, 4-7September 2016, Brighton, UK | 2016
Nicholas Mitroglou; Massimo Lorenzi; Maurizio Santini; Manolis Gavaises