Matteo Guzzini
Sapienza University of Rome
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Matteo Guzzini.
Microsurgery | 2009
S. Nicolino; Arianna Panetto; Stefania Raimondo; Giovanna Gambarotta; Matteo Guzzini; Michele Fornaro; Bruno Battiston; Perluigi Tos; Stefano Geuna; Isabelle Perroteau
Skeletal muscle atrophy represents one of the main causes of poor outcome of microsurgical nerve reconstruction. Recent studies have pointed to the importance of the neuregulin/ErbB signaling pathway in the development and regeneration of the neuromuscular system. Here, we show by immunohistochemistry, RT‐PCR, and Western blotting analyses, in an in vivo model of adult skeletal muscle denervation/reinnervation, that expression of Neuregulin1 (NRG1) and ErbB receptors is regulated by the innervation condition. We found out that a significant upregulation of the α‐, but not β‐, isoform of NRG1, as well as of ErbB2, ErbB3, and ErbB4‐cyt1 isoform occurs as a consequence of denervation of flexor digitorum muscles of the rat forelimb by median nerve transection. Moreover, after tubulization median nerve repair, and consequent muscle reinnervation, all messengers of the NRG1/ErbB system are promptly downregulated. Therefore, our results suggest the existence of a α‐NRG1‐mediated autocrine and/or paracrine trophic loop in skeletal muscles that is activated after denervation and promptly deactivated after nerve reconstruction. This myotrophic loop is a promising therapeutic target for the prevention of muscle atrophy. Yet, the recent demonstration of a similar α‐NRG1‐mediated gliotrophic loop in denervated Schwann cells provides a possible explanation for the effectiveness of muscle conduits for tubulization nerve repair.
Scandinavian Journal of Medicine & Science in Sports | 2017
Riccardo Maria Lanzetti; Alessandro Ciompi; Domenico Lupariello; Matteo Guzzini; A. De Carli
Our hypothesis is that there are no difference in the injury incidence on artificial turf and natural grass. During the 2011/2012 season, we recorded injuries which occurred to two Italian stadiums equipped with third‐generation artificial turf during 36 games (391 players). Data were compared with the injuries which occurred in the same season in two stadiums equipped with natural grass (372 players). We recorded 43 injuries during the playing time (16.7 per 1000 h). About 23 (18.1 per 1000 h) injuries occurred on artificial turf, while 20 (15.2 per 1000 h) on the natural grass with no statistical differences P > 0.05. We recorded 10 (7.87 per 1000 h) contact and 13 (10.23 per 1000 h) non‐contact injuries on artificial turf, while 5 (3.8 per 1000 h) contact and 15 (11.4 per 1000 h) non‐contact injuries on natural grass P > 0.05. The overall relative risk was 1.15; 95% CI: 0.64–2.07). Our study demonstrates a substantial equivalence in injury risk on natural grass and artificial turf in elite professional soccer athletes during official matches.
Orthopaedic Journal of Sports Medicine | 2017
Edoardo Monaco; Megan Rianne Wolf; Matteo Guzzini; Angelo De Carli; Daniele Mazza
Background: The Segond fracture is an avulsion-type fracture located on the anterolateral aspect of the tibia associated with a ligament recently termed the anterolateral ligament. This injury has been described as pathognomonic for an anterior cruciate ligament (ACL) tear and is associated with a higher grade pivot shift. Purpose: To present and report 2-year clinical outcomes of a surgical technique for acute ACL reconstruction with fixation of a concomitant Segond fracture. Study Design: Case series; Level of evidence, 4. Methods: A retrospective chart review was performed of patients who underwent acute reconstruction for a complete ACL tear with concomitant Segond fracture fixation between January 2010 and December 2014; surgery was performed by a single surgeon. Patients underwent direct Segond fracture repair by either suture alone, suture anchor, or cannulated screw fixation based on the size of the lesion, followed by a 2-incision hamstring autograft intra-articular reconstruction. Pre- and postoperative KT-1000 arthrometer assessment, Lachman test, and pivot-shift test were performed, and patients were administered validated subjective outcome surveys. Results: Twelve patients met inclusion criteria for this review. The measured pre- and postoperative objective and subjective scores were significantly improved in all patients. Side-to-side anterior laxity was significantly improved in all patients based on Lachman and KT-1000 arthrometer testing. A significant pivot shift demonstrated preoperatively (3+, n = 11 [92%]; 2+, n = 1 [8%]) was corrected after fixation, except in 1 patient (8%), who maintained a 1+ pivot shift. Lysholm, Tegner, and International Knee Documentation Committee subjective and objective scores were significantly improved. At a minimum 2-year follow-up, no patients reported rerupture, and only 1 patient (8%) underwent a subsequent procedure (a meniscectomy). No major or minor complications were reported, and all patients returned to their previous activity levels at a mean of 6 months postoperatively. Conclusion: Direct repair of the Segond fracture and plication of the anterolateral capsule in patients with an ACL rupture and a high-grade pivot shift demonstrate good clinical outcomes, restoration of rotational stability, and maintenance of knee range of motion at 2 years postoperatively, with no major complications.
Case reports in orthopedics | 2016
Matteo Guzzini; Cosma Calderaro; Marco Guidi; Carolina Civitenga; Germano Ferri
Introduction. The vascularized corticoperiosteal flap is harvested from the medial femoral condyle and it is nourished by the articular branch of the descending genicular artery and the superomedial genicular artery. This flap is usually harvested as a free flap for the reconstruction of bone defects at forearm, distal radius, carpus, hand, and recently at lower limb too. Case Report. A 50-year-old Caucasian man referred to our department for hypertrophic nonunion of the distal femur, refractory to the conservative treatments. The first surgical choice was the revision of the nail and the bone reconstruction with a corticoperiosteal pedicled flap from the medial femoral condyle. We considered union to have occurred 3.5 months after surgery when radiographs showed bridging of at least three of the four bony cortices and clinically the patient was able to walk with full weight bearing without any pain. At the last follow-up (25 months), the patient was completely satisfied with the procedure. Discussion. The corticoperiosteal flap allows a faster healing of fractures with a minimal morbidity at the donor site. We suggest that the corticoperiosteal pedicled flap graft is a reliable and effective treatment for distal femur nonunion.
Diabetes-metabolism Research and Reviews | 2018
Riccardo Maria Lanzetti; Domenico Lupariello; Teresa Venditto; Matteo Guzzini; Antonio Ponzo; Angelo De Carli
Open reduction and internal fixation is the standard treatment for displaced ankle fractures. However, the presence of comorbidities such as diabetes mellitus and body mass index (BMI) are associated with poor bone quality, and these factors may predict the development of postoperative complications.
Injury-international Journal of The Care of The Injured | 2017
Matteo Guzzini; Riccardo Maria Lanzetti; Dario Perugia; Domenico Lupariello; Antonio Vadalà; Marco Guidi; Carolina Civitenga
BACKGROUND AND PURPOSE Medial condyle corticoperiosteal flap is an emerging option for the treatment of upper limb non-infected nonunions. The hypothesis of our study is that corticoperiosteal flap could be an effective and safe procedure for the treatment of upper limb non-infected nonunions, evaluating radiographic and clinical outcome. METHODS We enrolled 14 patients who underwent vascularized medial femoral condyle corticoperiosteal free flaps from January 2011 to December 2014. All patients were clinically evaluated (VAS, DASH) before surgery and at 6 and 12 months post surgery. The radiographic evaluation was performed every 30 days until the complete healing and at 12-month follow-up. We also recorded the range of motion pre and post surgery at the donor site. RESULTS All nonunion sites healed primarily at an average time period of 5.2 months ±1. Preoperative DASH score was 70 ± 15.6; at 6 month follow-up was 21.51 ± 10.63; at 12 month follow-up 18.0 ± 9.9. Preoperative VAS was 7.05 ± 2; at 6-month follow-up was 2.1 ± 2; at 12-month follow-up was 1.8 ± 1.16. Statistical analysis showed a significant difference (p <0.001) about the preoperative and the postoperative VAS and DASH evaluation both at 6 and 12-month follow-up, but we did not record any statistical difference between the 6-month and 12-month follow-up. At the donor site, the mean VAS score was 2 ± 2.1 at seven days post operatively. All patients restore the full ROM at 7 days post surgery. CONCLUSIONS Vascularized medial condyle corticoperiosteal free flap represents an effective and safe procedure for the treatment of upper limb nonunions.
Journal of Foot & Ankle Surgery | 2017
Federico Morelli; Daniele Mazza; Pierluigi Serlorenzi; Marco Guidi; Emanuela Camerucci; Cosma Calderaro; Raffaele Iorio; Matteo Guzzini
Abstract The present study reports the clinical results of excision of a symptomatic os trigonum using an endoscopic procedure in professional ballet dancers. The hypothesis was that posterior endoscopic excision of the os trigonum would be safe and effective in treating posterior ankle impingement syndrome related to the os trigonum. Twelve professional dancers underwent excision of a symptomatic os trigonum for PAIS using a posterior endoscopic technique after failure of conservative treatment. The patients were evaluated pre‐ and postoperatively according to the American Orthopaedic Foot and Ankle Society hindfoot scale score, the Tegner activity scale score, and the visual analog scale score. The surgical time, timing of a return to sports, patient satisfaction, and any complications related to the procedure were recorded. The average postoperative follow‐up duration was 38.9 ± 20.6 (range 12 to 72) months. The mean Tegner activity scale score increased from 4.3 ± 0.8 (range 3 to 5) preoperatively to 9 ± 0.2 postoperatively (p < .05). The mean American Orthopaedic Foot and Ankle Society scale score increased from 67.8 ± 6.0 (range 58 to 76) preoperatively to 96 ± 5.1 (range 87 to 100) postoperatively, with 7 of 12 patients (58.3%) reporting the maximum score of 100 points (p < .05). The return to sports was 8.7 ± 0.7 (range 8 to 10) weeks. No major complications were recorded. The results of the present study demonstrate that the endoscopic excision of symptomatic os trigonum using a 2‐portal technique after failure of conservative treatment is characterized by excellent results with low morbidity. &NA; Level of Clinical Evidence: 4
Injury-international Journal of The Care of The Injured | 2017
Dario Perugia; Matteo Guzzini; Daniele Mazza; Carlo Iorio; Carolina Civitenga
INTRODUCTION Unstable intra articular fractures of distal radius are frequently being managed with open reduction and internal fixation. Volar locking plate based on polyetheretherketon (PEEK) polymer has developed lately as an alternative to conventional metallic devices. The advantage of this kind of plates include the lack of metal allergies, radiolucency, low artefacts on MRI or imaging scans and the high resistance associated to loading forces. The aim of this study was to evaluate the clinical and radiological results using a new Carbon-PEEK volar locking plate compared with titanium volar locking plates for the treatment of distal radius fractures. METHODS AND MATERIAL Thirty patients were included in this study. They all underwent traumatic intra-articular distal radius fractures and were surgically treated with volar locking plates. The patients were randomly divided in two groups: In Group A (15 patients) the fracture was stabilized with a CarboFix volar locking plate whereas in group B (15 patients) with an Acu-Lock Volar Distal Radius Plate. Range of motion (ROM), grip strength, Disabilities of the Arm, Shoulder and Hand (DASH) score and X-rays were evaluated. The mean follow up was 12 months. RESULTS Analysis of Wrist ROM revealed that there was no statistical significant difference (p > 0.05) in regards to extension, flexion, ulnar deviation, radial deviation, supination and pronation comparing to the unaffected arm and between Group A and Group B. The mean score on the DASH was 15.3 in Group A and 13.2 in Group B (p > 0.05). Patients were able to return to their normal activities of daily living at an average of 4 weeks post-op in both Groups. Overall, the mean VAS score was 3.6 There were no statistically significant differences (p > 0.05) on X-Rays examination between two Groups in regards to alignment and fracture healing. CONCLUSIONS Volar locking plates represent the most common procedure for the treatment of displaced distal radius fractures. In our series Carbon-peek volar locking plates seems to be analogue to titanium volar locking plates in terms of radiographic parameters and functional outcome.
Injury-international Journal of The Care of The Injured | 2017
Matteo Guzzini; Riccardo Maria Lanzetti; Domenico Lupariello; Federico Morelli; Giorgio Princi; Dario Perugia
INTRODUCTION The aim of our study is to compare the clinical and radiological outcomes of the treatment of distal fibular fracture with the traditional stainless steel or the new radiolucent CFR-PEEK plates. The hypothesis is that there are no differences in clinical and radiological outcomes at the final follow-up between the two fixation devices. METHODS All consecutive patients aged from 18 or over, who had undergone operative treatment for malleolar fracture between 2013 and 2014, have been included in the study. 87 were available for the study. The patients were assigned to group A (47 patients, radiolucent plate group) and group B (41 patients, stainless steal plate group). At 6, 12 and 24 months all patients were prospectively reviewed with radiographic and clinical evaluations (OMAS scale, AOFAS, VAS, ROM). RESULTS The groups were homogenous with regard to age, gender, BMI, dominance and disease duration. The mean follow-up was 23+/-2 months. The mean waiting time to operation was 2.94days (SD 2.74) (range 0.2-6.8). Statistical analysis showed no difference (p>0.05) about the VAS, OMAS, AOFAS and ROM evaluation at 6, 12 and 24 month follow-up between two groups. Radiographic evaluation showed no difference between two groups at all the follow-up with similar results obtained with the two fixation devices. DISCUSSION Our results showed a substantial equivalence of the two fixation devices at 6, 12 and 24 month of clinical and radiographic follow-up. Fixation of the lateral malleolus fractures with a CFR-PEEK plate provides satisfying clinical and radiographic results after 2 years of follow-up. These results are comparable to those achieved with conventional plates.
Case Reports in Plastic Surgery and Hand Surgery | 2016
Cosma Calderaro; Matteo Guzzini; Marco Pagnottelli; Mattia Fabbri; Dario Perugia
Abstract We report a case of post-traumatic trigger finger due to a partial longitudinal tear of the flexor digitorum superficialis. The suspect came from the clinical history and the young age of the patient. It was successfully treated with tendon flap suture and pulley A1 release.