Maxim Sergeev
University of California, Los Angeles
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Maxim Sergeev.
Journal of the American Chemical Society | 2015
Maxim Sergeev; Federica Morgia; Mark Lazari; Christopher Wang; R. Michael van Dam
Nucleophilic radiofluorination is an efficient synthetic route to many positron-emission tomography (PET) probes, but removal of water to activate the cyclotron-produced [(18)F]fluoride has to be performed prior to reaction, which significantly increases overall radiolabeling time and causes radioactivity loss. In this report, we demonstrate the possibility of (18)F-radiofluorination in highly aqueous medium. The method utilizes titania nanoparticles, 1:1 (v/v) acetonitrile-thexyl alcohol solvent mixture, and tetra-n-butylammonium bicarbonate as a phase-transfer agent. Efficient radiolabeling is directly performed with aqueous [(18)F]fluoride without the need for a drying/azeotroping step to significantly reduce radiosynthesis time. High radiochemical purity of the target compound is also achieved. The substrate scope of the synthetic strategy is demonstrated with a range of aromatic, aliphatic, and cycloaliphatic tosylated precursors.
Chemical Communications | 2014
Muhammad Rashed Javed; Supin Chen; Jack Lei; Jeffrey Collins; Maxim Sergeev; Hee-Kwon Kim; Chang-Jin Kim; R. Michael van Dam; Pei Yuin Keng
[(18)F]fallypride was synthesized in a batch microfluidic chip with a radiochemical yield of 65 ± 6% (n = 7) and an average specific activity of 730 GBq μmol(-1) (20 Ci μmol(-1)) (n = 4). Specific activity was ~2-fold higher than [(18)F]fallypride synthesized in a macroscale radiosynthesizer, despite starting with significantly less radioactivity, and thus safer conditions, in the microchip.
Archive | 2016
Pei Yuin Keng; Maxim Sergeev; R. Michael van Dam
Positron emission tomography (PET) provides quantitative 3D visualization of physiological parameters (e.g., metabolic rate, receptor density, gene expression, blood flow) in real time in the living body. By enabling measurement of differences in such characteristics between normal and diseased tissues, PET serves as vital tool for basic research as well as for clinical diagnosis and patient management. Prior to a PET scan, the patient is injected with a short-lived tracer labeled with a positron-emitting isotope. Safe preparation of the tracer is an expensive process, requiring specially trained personnel and high-cost equipment operated within hot cells. The current centralized manufacturing strategy, in which large batches are prepared and divided among many patients, enables the most commonly used tracer (i.e., [18F]FDG) to be obtained at an affordable price. However, as the diversity of tracers increases, other strategies for cost reduction will become necessary. This challenge is being addressed by the development of miniaturized radiochemistry instrumentation based on microfluidics. These compact systems have the potential to significantly reduce equipment cost and shielding while increasing diversity of tracers produced in a given facility. The most common approach uses “flow-through” microreactors, which leverage the ability to precisely control reaction conditions to improve synthesis times and yields. Several groups have also developed “batch” microreactors which offer significant additional advantages such as reduced reagent consumption, simpler purifications, and exceptionally high specific activity, by reducing operating volumes by orders of magnitude. In this chapter, we review these “batch” approaches and the advantages of using small volumes, with special emphasis on digital microfluidics, in which reactions have been performed with volumes as low as ~1 μL.
Communications Chemistry | 2018
Maxim Sergeev; Mark Lazari; Federica Morgia; Jeffrey Collins; Muhammad Rashed Javed; Olga Sergeeva; Jason Jones; Michael E. Phelps; Jason T. Lee; Pei Yuin Keng; R. Michael van Dam
Positron emission tomography (PET) is a molecular diagnostic imaging technology to quantitatively visualize biological processes in vivo. For many applications, including imaging of low-tissue density targets (e.g., neuroreceptors), imaging in small animals, and evaluation of novel tracers, the injected PET tracer must be produced with high molar activity to ensure low occupancy of biological targets and avoid pharmacologic effects. Additionally, high molar activity is essential for tracers with lengthy syntheses or tracers transported to distant imaging sites. Here we show that radiosynthesis of PET tracers in microliter volumes instead of conventional milliliter volumes results in substantially increased molar activity, and we identify the most relevant variables affecting this parameter. Furthermore, using the PET tracer [18F]fallypride, we illustrate that molar activity can have a significant impact on biodistribution. With full automation, microdroplet platforms could provide a means for radiochemists to routinely, conveniently, and safely produce PET tracers with high molar activity.For many applications, positron emission tomography tracers must be produced with high specific activity. Here the authors identify variables leading to increased specific activity when tracers are synthesized in microliter volumes, and show that specific activity can influence tracer biodistribution.
Proceedings of the National Academy of Sciences of the United States of America | 2017
Jeffrey Collins; Christopher M. Waldmann; Christopher Drake; Roger Slavik; Noel S. Ha; Maxim Sergeev; Mark Lazari; Bin Shen; Frederick T. Chin; Melissa J. Moore; Saman Sadeghi; Michael E. Phelps; Jennifer M. Murphy; R. Michael van Dam
Significance Molecular imaging with PET can provide a dynamic, whole-body picture of the rate of biological processes or distribution of biological targets by tracking the distribution of radiolabeled molecules or particles in the body over time. Continual efforts to develop new PET probes are expanding the variety of processes and targets that can be visualized, facilitating basic research, drug development, and patient care. However, access to these probes at all stages of their development is hindered by high costs arising, in large part, from the significant resources that are typically dedicated to production of a single probe. Emerging technologies with increased synthesis flexibility are allowing increased probe diversity with fewer resources and could significantly increase access to new molecular imaging agents. New radiolabeled probes for positron-emission tomography (PET) are providing an ever-increasing ability to answer diverse research and clinical questions and to facilitate the discovery, development, and clinical use of drugs in patient care. Despite the high equipment and facility costs to produce PET probes, many radiopharmacies and radiochemistry laboratories use a dedicated radiosynthesizer to produce each probe, even if the equipment is idle much of the time, to avoid the challenges of reconfiguring the system fluidics to switch from one probe to another. To meet growing demand, more cost-efficient approaches are being developed, such as radiosynthesizers based on disposable “cassettes,” that do not require reconfiguration to switch among probes. However, most cassette-based systems make sacrifices in synthesis complexity or tolerated reaction conditions, and some do not support custom programming, thereby limiting their generality. In contrast, the design of the ELIXYS FLEX/CHEM cassette-based synthesizer supports higher temperatures and pressures than other systems while also facilitating flexible synthesis development. In this paper, the syntheses of 24 known PET probes are adapted to this system to explore the possibility of using a single radiosynthesizer and hot cell for production of a diverse array of compounds with wide-ranging synthesis requirements, alongside synthesis development efforts. Most probes were produced with yields and synthesis times comparable to literature reports, and because hardware modification was unnecessary, it was convenient to frequently switch among probes based on demand. Although our facility supplies probes for preclinical imaging, the same workflow would be applicable in a clinical setting.
Nuclear Medicine and Biology | 2018
Ksenia Lisova; Maxim Sergeev; Susan Evans-Axelsson; Andreea D. Stuparu; Seval Beykan; Jeffrey Collins; Jason Jones; Michael Lassmann; Ken Herrmann; David M. Perrin; Jason T. Lee; Roger Slavik; R. Michael van Dam
BACKGROUND Peptides labeled with positron-emitting isotopes are emerging as a versatile class of compounds for the development of highly specific, targeted imaging agents for diagnostic imaging via positron-emission tomography (PET) and for precision medicine via theranostic applications. Despite the success of peptides labeled with gallium-68 (for imaging) or lutetium-177 (for therapy) in the clinical management of patients with neuroendocrine tumors or prostate cancer, there are significant advantages of using fluorine-18 for imaging. Recent developments have greatly simplified such labeling: in particular, labeling of organotrifluoroborates via isotopic exchange can readily be performed in a single-step under aqueous conditions and without the need for HPLC purification. Though an automated synthesis has not yet been explored, microfluidic approaches have emerged for 18F-labeling with high speed, minimal reagents, and high molar activity compared to conventional approaches. As a proof-of-concept, we performed microfluidic labeling of an octreotate analog ([18F]AMBF3-TATE), a promising 18F-labeled analog that could compete with [68Ga]Ga-DOTATATE with the advantage of providing a greater number of patient doses per batch produced. METHODS Both [18F]AMBF3-TATE and [68Ga]Ga-DOTATATE were labeled, the former by microscale methods adapted from manual labeling, and were imaged in mice bearing human SSTR2-overexpressing, rat SSTR2 wildtype, and SSTR2-negative xenografts. Furthermore, a dosimetry analysis was performed for [18F]AMBF3-TATE. RESULTS The micro-synthesis exhibited highly-repeatable performance with radiochemical conversion of 50 ± 6% (n = 15), overall decay-corrected radiochemical yield of 16 ± 1% (n = 5) in ~40 min, radiochemical purity >99%, and high molar activity. Preclinical imaging with [18F]AMBF3-TATE in SSTR2 tumor models correlated well with [68Ga]Ga-DOTATATE. The favorable biodistribution, with the highest tracer accumulation in the bladder followed distantly by gastrointestinal tissues, resulted in 1.26 × 10-2 mSv/MBq maximal estimated effective dose in human, a value lower than that reported for current clinical 18F- and 68Ga-labeled compounds. CONCLUSIONS The combination of novel chemical approaches to 18F-labeling and microdroplet radiochemistry have the potential to serve as a platform for greatly simplified development and production of 18F-labeled peptide tracers. Favorable preclinical imaging and dosimetry of [18F]AMBF3-TATE, combined with a convenient synthesis, validate this assertion and suggest strong potential for clinical translation.
Journal of Molecular Catalysis B-enzymatic | 2013
Maxim Sergeev; Federica Morgia; Muhammad Rashed Javed; Mami Doi; Pei Y. Keng
Journal of Molecular Catalysis B-enzymatic | 2013
Maxim Sergeev; Federica Morgia; Muhammad Rashed Javed; Mami Doi; Pei Y. Keng
Journal of Molecular Catalysis B-enzymatic | 2010
Maxim Sergeev; Tatiana L. Voyushina
Journal of Molecular Catalysis B-enzymatic | 2012
Maxim Sergeev; Tatiana L. Voyushina; Olga A. Sergeeva; Galina G. Belozerskaya