Mehmet Şenel
Fatih University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Mehmet Şenel.
Food Chemistry | 2015
Muamer Dervisevic; Esma Custiuc; Emre Çevik; Mehmet Şenel
A novel nanocomposite host matrix for enzyme immobilization of xanthine oxidase was developed by incorporating MWCNT in poly(GMA-co-VFc) copolymer film. In the food industry fish is a product with a very low commercial life, and a high variability as well elevated level of xanthine is an important biomarker as a sign of spoilage. The fabricated process was characterized by scanning electron microscopy (SEM), and the electrochemical behaviors of the biosensor were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The prepared enzyme electrodes exhibited maximum response at pH 7.0 and 45°C +0.35 V and reached 95% of steady-state current in about ∼ 4 s and its sensitivity was 16 mAM(-1). Linear ranges (2-28 μM, 28-46 and 46-86 μM), analytical performance and a low detection limit 0.12 μM obtained from the xanthine biosensor gives reliable results in measuring xanthine concentration in the fish meat. All the results indicating that the resulting biosensor exhibited a good response to xanthine that was related to the addition of MWCNT in the polymeric mediator film which played an important role in the biosensor performance. In addition, the biosensor exhibited high good storage stability and satisfactory anti-interference ability.
Central European Journal of Chemistry | 2007
A. Baykal; Yüksel Köseoğlu; Mehmet Şenel
Heating hydrous manganese (II) hydroxide gel at 85 °C for 12 hours produces Mn3O4 nanoparticles. They were characterized by X-ray powder diffraction (XRD) and infrared spectroscopy (FTIR). The particle size estimated from the SEM and X-ray peak broadening is approximately 32 nm, showing them to be nanocrystalline. EPR measurements confirm a typical Mn2+signal with a highly resolved hyperfine structure.
Biosensors and Bioelectronics | 2016
Emre Çevik; Özlem Bahar; Mehmet Şenel; M. Fatih Abasıyanık
In this study, an immunosensor was designed to utilize for the detection of prostate specific antigen (PSA) based on three different generations (G1, G2 and G3) of ferrocene (Fc) cored polyamidiamine dendrimers (Fc-PAMAM) gold (Au) electrode. The self-assembled monolayer principle (SAM) was used to fabricate the sensitive, selective and disposable immunosensor electrodes. In electrode fabrication cysteamine (Cys) was the first agent covalently linked on the Au electrode surface. Immobilized redox center (ferrocene) cored PAMAM dendrimers served as a layer for the further binding of biological components. The monoclonal antibody of PSA (anti-PSA) was covalently immobilized on dendrimers which were attached onto the modified Au surface (Au/Cys/Fc-PAMAMs/anti-PSA). PSA levels were quantitatively analyzed by using electrochemical differential pulse voltammetry (DPV) whose lowest detection limit was calculated as 0.001ngmL(-1). The Au/Cys/FcPAMAM/anti-PSA immunosensor showed excellent performance for PSA at the pulse amplitude; 50mV and the scan rate; 10mV/s in a wide linear concentration range of 0.01ng-100ngmL(-1). Analytical performance and specificity assays were carried out using human serum and different proteins.
Enzyme and Microbial Technology | 2015
Muamer Dervisevic; Emre Çevik; Mehmet Şenel
In this study, a novel glucose biosensor was fabricated by reconstitutional immobilization of glucose oxidase (GOx) onto a poly(glycidyl methacrylate-co-vinylferrocene) (poly(GMA-co-VFc)) film coated pencil graphite electrode (PGE). The amperometric current response of poly(GMA-co-VFc)-GOx to glucose is linear in the concentration range between 1 and 16mM (correlation coefficient of 0.9998) with a detection limit of 2.7μM (S/N=3). Experimental parameters were studied in detail and optimized, including the pH and temperature governing the analytical performance of the biosensor. The stability and reusability of the biosensor as well as its kinetic parameters have also been studied.
International Journal of Pharmaceutics | 2013
Fatma Ebru Koç; Mehmet Şenel
The aim of the present study was to evaluate the aqueous solubility enhancement properties of polypropylene oxide cored PAMAM (PPO@PAMAM) dendrimers. The solubility of NSAIDs (Ketoprofen, Ibuprofen and Diflunisal) was investigated in the presence of PPO@PAMAM dendrimers at room temperature in buffer solution. The effects of dendrimer concentration, generation and core size on the solubility of NSAIDs have been investigated. The experimental results showed that the solubility of the NSAIDs was approximately proportional to dendrimer concentration and generation. In addition, the effect of core size on the solubility of NSAIDs in constant generation and concentration of PPO@PAMAM dendrimer was Ketoprofen>Diflunisal>Ibuprofen. Under optimized conditions, PPO@PAMAM dendrimers are highly effective solubility enhancer for NSAIDs due to its new polypropylene oxide core.
Food Chemistry | 2017
Ahmet Güner; Emre Çevik; Mehmet Şenel; Lokman Alpsoy
An electrochemical immunosensor for the common food pathogen Escherichia coli O157:H7 was developed. This novel immunosensor based on the PPy/AuNP/MWCNT/Chi hybrid bionanocomposite modified pencil graphite electrode (PGE). This hybrid bionanocomposite platform was modified with anti-E. coli O157:H7 monoclonal antibody. The prepared bionanocomposite platform and immunosensor was characterized by using cyclic voltammetry (CV). Under the optimum conditions, the results have shown the order of the preferential selectivity of the method is gram negative pathogenic species E. coli O157:H7. Concentrations of E. coli O157:H7 from 3×101 to 3×107cfu/mL could be detected. The detection limit was ∼30cfu/mL in PBS buffer. Briefly, we developed a high sensitive electrochemical immunosensor for specific detection of E. coli O157:H7 contamination with the use of sandwich assay evaluated in this study offered a reliable means of quantification of the bacteria. For the applications in food quality and safety control, our immunosensor showed reproducibility and stability.
Materials Science and Engineering: C | 2015
Mehmet Şenel
A film of chitosan-polypyrrole-gold nanoparticles was fabricated by in-situ chemical synthesis method and its application in glucose biosensor was investigated. The obtained biosensor exhibited a high and reproducible sensitivity of 0.58μA/mM, response time ~4s, linear dynamic range from 1 to 20mM, correlation coefficient of R(2)=0.9981, and limit of detection (LOD), based on S/N ratio (S/N=3) of 0.068mM. A value of 1.83mM for the apparent Michaelis-Menten constant was obtained. The resulting bio-nanocomposite provided a suitable environment for the enzyme to retain its bioactivity at considerably extreme conditions, and the decorated gold nanoparticles in the bio-nanocomposite offer good affinity to enzyme.
Nano-micro Letters | 2011
Furkan Yalçıner; Emre Çevik; Mehmet Şenel; A. Baykal
Nickel ferrite (NiFe2O4) nanoparticles have been dispersed in chitosan solution in order to fabricate nanocomposite films. Horseradish peroxidase (HRP) has been immobilized onto this chitosan-NiFe2O4 nanocomposite film via physical adsorption. The size of the NiFe2O4 nanoparticles has been estimated using X-ray diffraction pattern and scanning electron microscopy (SEM) to be 40±9 nm. The chitosan-NiFe2O4 nanocomposite film and HRP/chitosan-NiFe2O4 bioelectrode have been characterized using SEM technique. The HRP/chitosan-NiFe2O4 nanocomposite bioelectrode has a response time of 4 s, linearity as 0.3 to 12mM of H2O2, sensitivity as 22 nA/mM. The effects of pH and the temperature of the immobilized HRP electrode have also been studied.
Materials Science and Engineering: C | 2016
Muamer Dervisevic; Emre Çevik; Mehmet Şenel
their effects on the properties of these biosensors. Biosensors were prepared by Horseradish peroxidase (HRP) immobilization on the composite electrodes composed of carbon black, carbon nanofiber (CNF), extended graphite, multiwalled carbon nanotube (MWCNT), reduced graphene oxide (REGO) and poly(glycidyl methacrylateco-vinylferrocene) (P(GMA-co-VFc)) as mediator, covalent linker, and host matrix for carbon derivatives. The modified pencil graphite electrode (PGE) was used for the detection of hydrogen peroxide and to follow electrochemical behavior of different carbon derivatives which were recorded. The electrochemical characterization was investigated by cyclic voltammetry and electrochemical impedance spectroscopy methods. Amperometric measurements showed that the REGO and MWCNT modified electrodes have excellent performance in comparison with other carbon derivatives studied.
Chemical Papers | 2010
Mehmet Şenel; Agah Coşkun; M. Fatih Abasıyanık; Ayhan Bozkurt
In this study, urease was immobilized in a polymer network obtained by complexation of poly(1-vinyl imidazole) (PVI) with poly(acrylic acid) (PAA). Preparation of the polymer network was monitored by FT-IR spectroscopy. Scanning electron microscopy (SEM) revealed that enzyme immobilization had a strong effect on film morphology. Proton conductivity of the PVI/PAA network was measured via impedance spectroscopy under humidified conditions. Values of the Michaelis-Menten constant (KM) for immobilized urease were higher than for the free enzyme, indicating a decreased affinity of the enzyme to its substrate. The basic characteristics (pHopt, pHstability, Topt, Tstability, reusability, and storage stability) of immobilized urease were determined. The results show that the PAA/PVI polymer network is suitable for enzyme immobilization.