Muamer Dervisevic
Fatih University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Muamer Dervisevic.
Food Chemistry | 2015
Muamer Dervisevic; Esma Custiuc; Emre Çevik; Mehmet Şenel
A novel nanocomposite host matrix for enzyme immobilization of xanthine oxidase was developed by incorporating MWCNT in poly(GMA-co-VFc) copolymer film. In the food industry fish is a product with a very low commercial life, and a high variability as well elevated level of xanthine is an important biomarker as a sign of spoilage. The fabricated process was characterized by scanning electron microscopy (SEM), and the electrochemical behaviors of the biosensor were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The prepared enzyme electrodes exhibited maximum response at pH 7.0 and 45°C +0.35 V and reached 95% of steady-state current in about ∼ 4 s and its sensitivity was 16 mAM(-1). Linear ranges (2-28 μM, 28-46 and 46-86 μM), analytical performance and a low detection limit 0.12 μM obtained from the xanthine biosensor gives reliable results in measuring xanthine concentration in the fish meat. All the results indicating that the resulting biosensor exhibited a good response to xanthine that was related to the addition of MWCNT in the polymeric mediator film which played an important role in the biosensor performance. In addition, the biosensor exhibited high good storage stability and satisfactory anti-interference ability.
Enzyme and Microbial Technology | 2015
Muamer Dervisevic; Emre Çevik; Mehmet Şenel
In this study, a novel glucose biosensor was fabricated by reconstitutional immobilization of glucose oxidase (GOx) onto a poly(glycidyl methacrylate-co-vinylferrocene) (poly(GMA-co-VFc)) film coated pencil graphite electrode (PGE). The amperometric current response of poly(GMA-co-VFc)-GOx to glucose is linear in the concentration range between 1 and 16mM (correlation coefficient of 0.9998) with a detection limit of 2.7μM (S/N=3). Experimental parameters were studied in detail and optimized, including the pH and temperature governing the analytical performance of the biosensor. The stability and reusability of the biosensor as well as its kinetic parameters have also been studied.
Biosensors and Bioelectronics | 2017
Muamer Dervisevic; Mehmet Senel; Tugba Sagir; Sevim Isik
The detection of cancer cells through important molecular recognition target such as sialic acid is significant for the clinical diagnosis and treatment. There are many electrochemical cytosensors developed for cancer cells detection but most of them have complicated fabrication processes which results in poor reproducibility and reliability. In this study, a simple, low-cost, and highly sensitive electrochemical cytosensor was designed based on boronic acid-functionalized polythiophene. In cytosensors fabrication simple single-step procedure was used which includes coating pencil graphite electrode (PGE) by means of electro-polymerization of 3-Thienyl boronic acid and Thiophen. Electrochemical impedance spectroscopy and cyclic voltammetry were used as an analytical methods to optimize and measure analytical performances of PGE/P(TBA0.5Th0.5) based electrode. Cytosensor showed extremely good analytical performances in detection of cancer cells with linear rage of 1×101 to 1×106 cellsmL-1 exhibiting low detection limit of 10 cellsmL-1 and incubation time of 10min. Next to excellent analytical performances, it showed high selectivity towards AGS cancer cells when compared to HEK 293 normal cells and bone marrow mesenchymal stem cells (BM-hMSCs). This method is promising for future applications in early stage cancer diagnosis.
Materials Science and Engineering: C | 2016
Muamer Dervisevic; Emre Çevik; Mehmet Şenel
their effects on the properties of these biosensors. Biosensors were prepared by Horseradish peroxidase (HRP) immobilization on the composite electrodes composed of carbon black, carbon nanofiber (CNF), extended graphite, multiwalled carbon nanotube (MWCNT), reduced graphene oxide (REGO) and poly(glycidyl methacrylateco-vinylferrocene) (P(GMA-co-VFc)) as mediator, covalent linker, and host matrix for carbon derivatives. The modified pencil graphite electrode (PGE) was used for the detection of hydrogen peroxide and to follow electrochemical behavior of different carbon derivatives which were recorded. The electrochemical characterization was investigated by cyclic voltammetry and electrochemical impedance spectroscopy methods. Amperometric measurements showed that the REGO and MWCNT modified electrodes have excellent performance in comparison with other carbon derivatives studied.
Materials Science and Engineering: C | 2017
Muamer Dervisevic; Mehmet Senel; Emre Çevik
In this study we report a new, simple and first impedimetric biosensor based on 3-Thienyl boronic acid for dopamine detection. Biosensor electrode preparation is 1min long by simple electro-polymerization of 3-Thienyl boronic acid and copolymer Thiophene P(TBA0.50Th0.50). Strong interaction between dopamine and thin layer of boronic acid has provided bio-sensing electrode high selectivity and stability, linear range of 7.8 to 125μM, and detection limit of 0.3μM. Characterization and optimization studies were conducted using electrochemical impedance spectroscopy (EIS) and cyclic voltammogram (CV). In order to test reliability of proposed biosensor real sample application study has been conducted using non-diluted human urine and it has been found that biosensor selectivity and recovery is excellent. As well P(TBA0.50Th0.50) based electrode and dopamine interaction has been proven by single frequency impedance measurements. Biosensors acquired good reproducibility, stability, selectivity and very low interference.
Biosensors and Bioelectronics | 2017
Muamer Dervisevic; Mehmet Şenel; Tugba Sagir; Sevim Isik
A comparative study is reported where folic acid (FA) and boronic acid (BA) based cytosensors and their analytical performances in cancer cell detection were analyzed by using electrochemical impedance spectroscopy (EIS) method. Cytosensors were fabricated using self-assembled monolayer principle by modifying Au electrode with cysteamine (Cys) and immobilization of ferrocene cored polyamidiamine dendrimers second generation (Fc-PAMAM (G2)), after which electrodes were modified with FA and BA. Au/Fc-PAMAM(G2)/FA and Au/Fc-PAMAM(G2)/BA based cytosensors showed extremely good analytical performances in cancer cell detection with linear range of 1×102 to 1×106cellsml-1, detection limit of 20cellsml-1 with incubation time of 20min for FA based electrode, and for BA based electrode detection limit was 28cellsml-1 with incubation time of 10min. Next to excellent analytical performances, cytosensors showed high selectivity towards cancer cells which was demonstrated in selectivity study using human embryonic kidney 293 cells (HEK 293) as normal cells and Au/Fc-PAMAM(G2)/FA electrode showed two times better selectivity than BA modified electrode. These cytosensors are promising for future applications in cancer cell diagnosis.
Enzyme and Microbial Technology | 2017
Muamer Dervisevic; Esma Dervisevic; Mehmet Senel; Emre Çevik; Huseyin Bekir Yildiz; Pinar Camurlu
Herein, an electrochemical urea sensing bio-electrode is reported that has been constructed by firstly electropolymerizing 4-(2,5-Di(thiophen-2-yl)-1H-pyrrol-1-yl)aniline monomer (SNS-Aniline) on Pencil Graphite Electrode (PGE), then modifying the polymer coated electrode surface with di-amino-Ferrocene (DAFc) as the mediator, and lastly Urease enzyme through glutaraldehyde crosslinking. The effect of pH, temperature, polymer thickness, and applied potential on the electrode current response was investigated besides performing storage and operational stability experiments with the interference studies. The resulting urea biosensors amperometric response was linear in the range of 0.1-8.5mM with the sensitivity of 0.54μA/mM, detection limit of 12μM, and short response time of 2s. The designed bio-electrode was tested with real human blood and urine samples where it showed excellent analytical performance with insignificant interference.
Sensors and Actuators B-chemical | 2016
Muamer Dervisevic; Esma Dervisevic; Hacer Azak; Emre Çevik; Mehmet Şenel; Huseyin Bekir Yildiz
Electroanalysis | 2013
Mehmet Şenel; Cevdet Nergiz; Muamer Dervisevic; Emre Çevik
Food Control | 2015
Muamer Dervisevic; Esma Custiuc; Emre Çevik; Mehmet Şenel; Ali Durmus