Melvin A. Park
Bruker
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Melvin A. Park.
International Journal for Ion Mobility Spectrometry | 2011
Francisco Fernandez-Lima; Desmond Allen Kaplan; J. Suetering; Melvin A. Park
In the present work we describe the principles of operation, versatility and applicability of a trapped ion mobility spectrometer (TIMS) analyzer for fast, gas-phase separation of molecular ions based on their size-to-charge ratio. Mobility-based separation using a TIMS device is shown for a series for isobar pairs. In a TIMS device, mobility resolution depends on the bath gas velocity and analysis scan speed, with the particularity that the mobility separation can be easily tuned from low to high resolution (R > 50) in accordance with the analytical challenge . In contrast to traditional drift tube IMS analyzer, a TIMS device can be easily integrated in a mass spectrometer without a noticeable loss in ion transmission or sensitivity, thus providing a powerful separation platform prior to mass analysis.
Journal of the American Society for Mass Spectrometry | 2015
Karsten Michelmann; Joshua A. Silveira; Mark E. Ridgeway; Melvin A. Park
AbstractTrapped ion mobility spectrometry (TIMS) is a relatively new gas-phase separation method that has been coupled to quadrupole orthogonal acceleration time-of-flight mass spectrometry. The TIMS analyzer is a segmented rf ion guide wherein ions are mobility-analyzed using an electric field that holds ions stationary against a moving gas, unlike conventional drift tube ion mobility spectrometry where the gas is stationary. Ions are initially trapped, and subsequently eluted from the TIMS analyzer over time according to their mobility (K). Though TIMS has achieved a high level of performance (R > 250) in a small device (<5 cm) using modest operating potentials (<300 V), a proper theory has yet to be produced. Here, we develop a quantitative theory for TIMS via mathematical derivation and simulations. A one-dimensional analytical model, used to predict the transit time and theoretical resolving power, is described. Theoretical trends are in agreement with experimental measurements performed as a function of K, pressure, and the axial electric field scan rate. The linear dependence of the transit time with 1/K provides a fundamental basis for determination of reduced mobility or collision cross section values by calibration. The quantitative description of TIMS provides an operational understanding of the analyzer, outlines the current performance capabilities, and provides insight into future avenues for improvement. Graphical Abstractᅟ
Analyst | 2014
Diana Rosa Hernandez; John Daniel DeBord; Mark E. Ridgeway; Desmond Allen Kaplan; Melvin A. Park; Francisco Fernandez-Lima
In the present paper, theoretical simulations and experimental observations are used to describe the ion dynamics in a trapped ion mobility spectrometer. In particular, the ion motion, ion transmission and mobility separation are discussed as a function of the bath gas velocity, radial confinement, analysis time and speed. Mobility analysis and calibration procedure are reported for the case of sphere-like molecules for positive and negative ion modes. Results showed that a maximal mobility resolution can be achieved by optimizing the gas velocity, radial confinement (RF amplitude) and ramp speed (voltage range and ramp time). The mobility resolution scales with the electric field and gas velocity and R = 100-250 can be routinely obtained at room temperature.
Analytical Chemistry | 2014
Joshua A. Silveira; Mark E. Ridgeway; Melvin A. Park
In the present work, we employ trapped ion mobility spectrometry (TIMS) for conformational analysis of several model peptides. The TIMS distributions are extensively compared to recent ion mobility spectrometry (IMS) studies reported in the literature. At a resolving power (R) exceeding 250, many new features, otherwise hidden by lower resolution IMS analyzers, are revealed. Though still principally limited by the plurality of conformational states, at present, TIMS offers R up to ∼3 to 8 times greater than modern drift tube or traveling wave IMS techniques, respectively. Unlike differential IMS, TIMS not only is able to resolve congested conformational features but also can be used to determine information about their relative size, via the ion-neutral collision cross section, offering a powerful new platform to probe the structure and dynamics of biochemical systems in the gas phase.
Analytical Chemistry | 2016
Yi Pu; Mark E. Ridgeway; Rebecca S. Glaskin; Melvin A. Park; Catherine E. Costello; Cheng Lin
One of the major challenges in structural characterization of oligosaccharides is the presence of many structural isomers in most naturally occurring glycan mixtures. Although ion mobility spectrometry (IMS) has shown great promise in glycan isomer separation, conventional IMS separation occurs on the millisecond time scale, largely restricting its implementation to fast time-of-flight (TOF) analyzers which often lack the capability to perform electron activated dissociation (ExD) tandem MS analysis and the resolving power needed to resolve isobaric fragments. The recent development of trapped ion mobility spectrometry (TIMS) provides a promising new tool that offers high mobility resolution and compatibility with high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometers when operated under the selected accumulation-TIMS (SA-TIMS) mode. Here, we present our initial results on the application of SA-TIMS-ExD-FTICR MS to the separation and identification of glycan linkage isomers.
Rapid Communications in Mass Spectrometry | 2008
Desmond Allen Kaplan; Ralf Hartmer; J. Paul Speir; Carsten Stoermer; Dmitry R. Gumerov; Michael L. Easterling; Andreas Brekenfeld; Taeman Kim; Frank H. Laukien; Melvin A. Park
Electron transfer dissociation (ETD) of proteins is demonstrated in a hybrid quadrupole-hexapole Fourier transform ion cyclotron resonance mass spectrometer (Qh-FTICRMS). Analyte ions are selected in the mass analyzing quadrupole, accumulated in the hexapole linear ion trap, reacted with fluoranthene reagent anions, and then analyzed via an FTICR mass analyzer. The hexapole trap allows for a broad fragment ion mass range and a high ion storage capacity. Using a 3 T FTICRMS, resolutions of 60 000 were achieved with mass accuracies averaging below 1.4 ppm. The high resolution, high mass accuracy ETD spectra provided by FTICR obviates the need for proton transfer reaction (PTR) charge state reduction of ETD product ions when analyzing proteins or large peptides. This is demonstrated with the ETD of ubiquitin and apomyoglobin yielding sequence coverages of 37 and 20%, respectively. We believe this represents the first reported successful combination of ETD and a FTICRMS.
Journal of the American Society for Mass Spectrometry | 2014
Muchena J. Kailemia; Melvin A. Park; Desmond Allen Kaplan; Andre Venot; Geert-Jan Boons; Lingyun Li; Robert J. Linhardt; I. Jonathan Amster
AbstractHigh-field asymmetric waveform ion mobility spectrometry (FAIMS) is shown to be capable of resolving isomeric and isobaric glycosaminoglycan negative ions and to have great utility for the analysis of this class of molecules when combined with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and tandem mass spectrometry. Electron detachment dissociation (EDD) and other ion activation methods for tandem mass spectrometry can be used to determine the sites of labile sulfate modifications and for assigning the stereochemistry of hexuronic acid residues of glycosaminoglycans (GAGs). However, mixtures with overlapping mass-to-charge values present a challenge, as their precursor species cannot be resolved by a mass analyzer prior to ion activation. FAIMS is shown to resolve two types of mass-to-charge overlaps. A mixture of chondroitin sulfate A (CSA) oligomers with 4–10 saccharides units produces ions of a single mass-to-charge by electrospray ionization, as the charge state increases in direct proportion to the degree of polymerization for these sulfated carbohydrates. FAIMS is shown to resolve the overlapping charge. A more challenging type of mass-to-charge overlap occurs for mixtures of diastereomers. FAIMS is shown to separate two sets of epimeric GAG tetramers. For the epimer pairs, the complexity of the separation is reduced when the reducing end is alkylated, suggesting that anomers are also resolved by FAIMS. The resolved components were activated by EDD and the fragment ions were analyzed by FTICR-MS. The resulting tandem mass spectra were able to distinguish the two epimers from each other. Figureᅟ
Analytical Chemistry | 2014
Emily R. Schenk; Vanesa Mendez; John T. Landrum; Mark E. Ridgeway; Melvin A. Park; Francisco Fernandez-Lima
In the present paper, trapped ion mobility spectrometry (TIMS) and theoretical calculations have been used to study carotenoid geometrical motifs generated by photoisomerization from the all-trans geometry. Multiple geometric isomers of the carotenoids lutein and zeaxanthin were separated using TIMS (R > 110) for [M]+, [M + H]+, and [M – 18]+ molecular species. Comparison of observed cross sections with those obtained from molecular dynamics calculations showed that the number of cis double bonds and s-cis single bonds in the polyene chain determine the topology space of the carotenoid. The intensities of IMS signals are correlated with the relative stability of these geometric isomers.1,2 The most stable isomer is the all-trans geometry regardless of the ionization state ([M – 18]+, [M]+, and [M + H]+), and structural stability decreases with the increasing number of cis and/or s-cis bonds in the polyene chain.
Analytical Chemistry | 2015
Paolo Benigni; Christopher J. Thompson; Mark E. Ridgeway; Melvin A. Park; Francisco Fernandez-Lima
Traditional separation and detection of targeted compounds from complex mixtures from environmental matrices requires the use of lengthy prefractionation steps and high-resolution mass analyzers due to the large number of chemical components and their large structural diversity (highly isomeric). In the present work, selected accumulation trapped ion mobility spectrometry (SA-TIMS) is coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) for direct separation and characterization of targeted endocrine-disrupting compounds (EDC) from a complex environmental matrix in a single analysis. In particular, targeted identification based on high-resolution mobility (R ∼ 70-120) and ultrahigh-resolution mass measurements (R > 400 000) of seven commonly targeted EDC and their isobars (e.g., bisphenol A, (Z)- and (E)-diethylstilbestrol, hexestrol, estrone, α-estradiol, and 17-ethynylestradiol) is shown from a complex mixture of water-soluble organic matter (e.g., Suwannee River Fulvic Acid Standard II) complemented with reference standard measurements and theoretical calculations (<3% error).
Journal of the American Society for Mass Spectrometry | 2015
Emily R. Schenk; Raybel Almeida; Jaroslava Miksovska; Mark E. Ridgeway; Melvin A. Park; Francisco Fernandez-Lima
AbstractIn the present work, the kinetic intermediates of holo- and apo-myoglobin were studied by correlating the ion-neutral collision cross section and time resolved H/D back exchange rate simultaneously in a trapped ion mobility spectrometer coupled to a mass spectrometer (HDX-TIMS-MS). The high mobility resolution of the TIMS cell permitted the observation of multiple IMS bands and complementary molecular dynamics simulations resulted in the assignment of candidate structures for each experimental condition studied (e.g., holo [M + 8H]+8–[M + 9H]+9 and apo [M + 9H]+9–[M + 19H]+19). Inspection of the kinetic intermediates suggests that the tertiary structure of apomyoglobin unfolds quickly upon the loss of the Fe protoporphyrin IX that stabilizes the interactions between the A, G, and H helices. In the absence of the porphyrin heme, the apomyoglobin unfolds to Xn kinetic intermediates that vary in the extent of unfolding as a result of the observed charge state. Graphical Abstractᅟ