Analytical Chemistry | 2015

Candidate Reference Measurement Procedure for the Determination of (24R),25-Dihydroxyvitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry.

Susan S.-C. Tai; Michael A. Nelson

The two major forms of vitamin D, vitamin D3 and vitamin D2, are metabolized in the liver through hydroxylation to 25-hydroxyvitamin D species, and then further hydroxylated in the kidney to various dihydroxyvitamin D species. (24R),25-Dihydroxyvitamin D3 ((24R),25(OH)2D3) is a major catabolite of 25-hydroxyvitamin D metabolism and is an important vitamin D metabolite used as a catabolism marker and indicator of kidney disease. The National Institute of Standards and Technology has recently developed a reference measurement procedure for the determination of (24R),25(OH)2D3 in human serum using isotope-dilution LC-MS/MS. The (24R),25(OH)2D3 and added deuterated labeled internal standard (24R),25(OH)2D3-d6 were extracted from serum matrix using liquid-liquid extraction prior to LC-MS/MS analysis. Chromatographic separation was performed using a fused-core C18 column. Atmospheric pressure chemical ionization in the positive ion mode and multiple reaction monitoring were used for LC-MS/MS. The accuracy of the measurement of (24R),25(OH)2D3 was evaluated by recovery studies of measuring (24R),25(OH)2D3 in gravimetrically prepared spiked samples of human serum with known (24R),25(OH)2D3 levels. The recoveries of the added (24R),25(OH)2D3 averaged 99.0% (0.8% SD), and the extraction efficiencies averaged 95% (2% SD). Excellent repeatability was demonstrated with CVs of ∼1%. The limit of quantitation at a signal-to-noise ratio of ∼10 was 0.2 ng/g. Potential isomeric interferences from other endogenous species and from impurity components of the reference standard were investigated. LC baseline resolution of (24R),25(OH)2D3 from these isomers was achieved within 35 min. This method was used for value assignment of (24R),25(OH)2D3 in Standard Reference Materials of Vitamin D Metabolites in Human Serum, which can serve as an accuracy base for routine methods used in clinical laboratories.


Analytical and Bioanalytical Chemistry | 2015

Metrological approaches to organic chemical purity: primary reference materials for vitamin D metabolites

Michael A. Nelson; Mary Bedner; Brian E. Lang; Blaza Toman; Katrice A. Lippa

Given the critical role of pure, organic compound primary reference standards used to characterize and certify chemical Certified Reference Materials (CRMs), it is essential that associated mass purity assessments be fit-for-purpose, represented by an appropriate uncertainty interval, and metrologically sound. The mass fraction purities (% g/g) of 25-hydroxyvitamin D (25(OH)D) reference standards used to produce and certify values for clinical vitamin D metabolite CRMs were investigated by multiple orthogonal quantitative measurement techniques. Quantitative 1H-nuclear magnetic resonance spectroscopy (qNMR) was performed to establish traceability of these materials to the International System of Units (SI) and to directly assess the principal analyte species. The 25(OH)D standards contained volatile and water impurities, as well as structurally-related impurities that are difficult to observe by chromatographic methods or to distinguish from the principal 25(OH)D species by one-dimensional NMR. These impurities have the potential to introduce significant biases to purity investigations in which a limited number of measurands are quantified. Combining complementary information from multiple analytical methods, using both direct and indirect measurement techniques, enabled mitigation of these biases. Purities of 25(OH)D reference standards and associated uncertainties were determined using frequentist and Bayesian statistical models to combine data acquired via qNMR, liquid chromatography with UV absorbance and atmospheric pressure-chemical ionization mass spectrometric detection (LC-UV, LC-ACPI-MS), thermogravimetric analysis (TGA), and Karl Fischer (KF) titration.


Journal of AOAC International | 2017

Interlaboratory Comparison for the Determination of 24,25-Dihydroxyvitamin D3 in Human Serum Using Liquid Chromatography with Tandem Mass Spectrometry.

Stephen A. Wise; Susan S.-C. Tai; Michael A. Nelson; Carolyn Q. Burdette; Johanna E. Camara; Andrew N. Hoofnagle; Thomas J. Laha; Graham D. Carter; Julia Jones; Emma L. Williams; Zoe J. Barclay; Glenville Jones; Martin Kaufmann; Neil Binkley; Amita Kapoor; Toni E. Ziegler; Kevin D. Cashman; Kirsten G. Dowling; Christopher T. Sempos

Six laboratories associated with the Vitamin D Standardization Program (VDSP) participated in an interlaboratory comparison of LC with tandem MS (MS/MS) methods for the determination of 24,25-dihydroxyvitamin D3 [24,25(OH)2D3] in human serum. The laboratories analyzed two different serum-based Standard Reference Materials (SRMs) intended for use in the determination of 25-hydroxyvitamin D and 30 samples from the Vitamin D External Quality Assessment Scheme (DEQAS). All laboratory methods for 24,25(OH)2D3 were based on isotope dilution LC-MS/MS; three of the methods used derivatization of the vitamin D metabolites before LC-MS/MS. Laboratory results were compared to the National Institute of Standards and Technology (NIST) results, which were obtained using their newly developed candidate reference measurement procedure for 24,25(OH)2D3. Laboratory results for the SRM samples varied in comparability to the NIST results, with one laboratory in excellent agreement (-1.6% mean bias), three laboratories at 10-15% mean bias, and the remaining laboratory at 36% mean bias. For the 30 DEQAS samples, the mean bias for the five laboratories ranged from 6 to 15%; however, the SD of the bias ranged from 8 to 29%. As a result of this intercomparison study, one laboratory discovered and corrected a method calculation error and another laboratory modified and improved their LC-MS/MS method.


Analytical and Bioanalytical Chemistry | 2017

Liquid chromatography with absorbance detection and with isotope-dilution mass spectrometry for determination of isoflavones in soy standard reference materials

Melissa M. Phillips; Mary Bedner; Manuela Reitz; Carolyn Burdette; Michael A. Nelson; James H. Yen; Lane C. Sander; Catherine A. Rimmer

AbstractTwo independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical AbstractSeparation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate


Metrologia | 2016

Chemical purity using quantitative 1H-nuclear magnetic resonance: a hierarchical Bayesian approach for traceable calibrations

Blaza Toman; Michael A. Nelson; Katrice A. Lippa

Chemical purity assessment using quantitative 1H-nuclear magnetic resonance spectroscopy is a method based on ratio references of mass and signal intensity of the analyte species to that of chemical standards of known purity. As such, it is an example of a calculation using a known measurement equation with multiple inputs. Though multiple samples are often analyzed during purity evaluations in order to assess measurement repeatability, the uncertainty evaluation must also account for contributions from inputs to the measurement equation. Furthermore, there may be other uncertainty components inherent in the experimental design, such as independent implementation of multiple calibration standards. As such, the uncertainty evaluation is not purely bottom up (based on the measurement equation) or top down (based on the experimental design), but inherently contains elements of both. This hybrid form of uncertainty analysis is readily implemented with Bayesian statistical analysis. In this article we describe this type of analysis in detail and illustrate it using data from an evaluation of chemical purity and its uncertainty for a folic acid material.


Analytical Chemistry | 2018

A new realization of SI for organic chemical measurement: NIST PS1 Primary Standard for quantitative NMR (Benzoic Acid)

Michael A. Nelson; Jason F. Waters; Blaza Toman; Brian E. Lang; Alexander Rueck; Kathrin Breitruck; Markus Obkircher; Tony Windust; Katrice A. Lippa

Metrological traceability to common references supports the comparability of chemical measurement results produced by different analysts, at various times, and at separate places. Ideally, these references are realizations of base units of the International System of Units (SI). ISO/IEC 17025 (Clause 6.5) states that traceability of measurement results is a necessary attribute of analytical laboratory competence, and as such, has become compulsory in many industries, especially clinical diagnostics and healthcare. Historically, claims of traceability for organic chemical measurements have relied on calibration chains anchored on unique reference materials with linkage to the SI that is tenuous at best. A first-of-its-kind National Institute of Standards and Technology (NIST) reference material, ultrapure and extensively characterized PS1 Benzoic Acid Primary Standard for quantitative NMR (qNMR), serves as a definitive, primary reference (calibrant) that assuredly links the qNMR spectroscopy technique to SI units. As qNMR itself is a favorable method for accurate, direct characterization of chemical reference materials, PS1 is a standard for developing other traceable standards and is intended to establish traceability for the measurement of thousands of organic chemical species. NIST PS1 will play a critical role in directly promoting accuracy and worldwide comparability of measurement results produced by the chemical measurement community, supporting the soundness of clinical diagnostics, food safety and labeling, forensic investigation, drug development, biomedical research, and chemical manufacturing. Confidence in this link to the SI was established through (i) unambiguous identification of chemical structure; (ii) determinations of isotopic composition and molecular weight; (iii) evaluation of the respective molecular amount by multiple primary measurement procedures, including qNMR and coulometry; and (iv) rigorous evaluation of measurement uncertainty using state-of-the-art statistical methods and measurement models.


Metrologia | 2017

Rigorous evaluation of chemical measurement uncertainty: liquid chromatographic analysis methods using detector response factor calibration

Blaza Toman; Michael A. Nelson; Mary Bedner

Chemical measurement methods are designed to promote accurate knowledge of a measurand or system. As such, these methods often allow elicitation of latent sources of variability and correlation in experimental data. They typically implement measurement equations that support quantification of effects associated with calibration standards and other known or observed parametric variables. Additionally, multiple samples and calibrants are usually analyzed to assess accuracy of the measurement procedure and repeatability by the analyst. Thus, a realistic assessment of uncertainty for most chemical measurement methods is not purely bottom-up (based on the measurement equation) or top-down (based on the experimental design), but inherently contains elements of both. Confidence in results must be rigorously evaluated for the sources of variability in all of the bottom-up and top-down elements. This type of analysis presents unique challenges due to various statistical correlations among the outputs of measurement equations. One approach is to use a Bayesian hierarchical (BH) model which is intrinsically rigorous, thus making it a straightforward method for use with complex experimental designs, particularly when correlations among data are numerous and difficult to elucidate or explicitly quantify. In simpler cases, careful analysis using GUM Supplement 1 (MC) methods augmented with random effects meta analysis yields similar results to a full BH model analysis. In this article we describe both approaches to rigorous uncertainty evaluation using as examples measurements of 25-hydroxyvitamin D3 in solution reference materials via liquid chromatography with UV absorbance detection (LC-UV) and liquid chromatography mass spectrometric detection using isotope dilution (LC-IDMS).


Journal of AOAC International | 2017

Role of the National Institute of Standards and Technology (NIST) in Support of the Vitamin D Initiative of the National Institutes of Health, Office of Dietary Supplements

Stephen A. Wise; Susan S.-C. Tai; Carolyn Q. Burdette; Johanna E. Camara; Mary Bedner; Katrice A. Lippa; Michael A. Nelson; Federica Nalin; Karen W. Phinney; Lane C. Sander; Joseph M. Betz; Christopher T. Sempos; Paul M. Coates

Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.


Journal of AOAC International | 2017

Development of Standard Reference Material (SRM) 2973 Vitamin D Metabolites in Frozen Human Serum (High Level)

Susan S.-C. Tai; Michael A. Nelson; Mary Bedner; Brian E. Lang; Karen W. Phinney; Lane C. Sander; James H. Yen; Joseph M. Betz; Christopher T. Sempos; Stephen A. Wise


Archive | 2018

CCQM-K55.d (Folic acid) Final Report

Steven Westwood; Ralf D. Josephs; Tiphaine Choteau; Adeline Daireaux; N. Stoppacher; Robert Wielgosz; Stephen Davies; E. do Rego; Wagner Wollinger; Bruno Garrido; J. Fernandes; J. Lima; R. Oliveira; R. de Sena; Anthony Windust; Ting Huang; Xinhua Dai; Can Quan; H. He; Wei Zhang; C. Wei; N. Li; D. Gao; Z. Liu; Man-fung Lo; Wai-fun Wong; Dietmar Pfeifer; Matthias Koch; Ute Dorgerloh; Robert Rothe

Collaboration


Dive into the Michael A. Nelson's collaboration.

Top Co-Authors

Avatar

Katrice A. Lippa

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Mary Bedner

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Blaza Toman

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Brian E. Lang

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Lane C. Sander

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Christopher T. Sempos

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Johanna E. Camara

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Stephen A. Wise

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Susan S.-C. Tai

National Institute of Standards and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge