Miklós Weszl
Semmelweis University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Miklós Weszl.
Journal of Orthopaedic Research | 2012
Miklós Weszl; Gábor Skaliczki; Attila Cselenyák; Levente Kiss; Tibor Major; Károly Schandl; Eszter Bognár; Guido Stadler; Anja Peterbauer; Lajos Csönge; Zsombor Lacza
Mineralized scaffolds are widely used as bone grafts with the assumption that bone marrow derived cells colonize and remodel them. This process is slow and often unreliable so we aimed to improve the biocompatibility of bone grafts by pre‐seeding them with human mesenchymal stem cells from either bone marrow or dental pulp. Under standard cell culture conditions very low number of seeded cells remained on the surface of freeze‐dried human or bovine bone graft or hydroxyapatite. Coating the scaffolds with fibronectin or collagen improved seeding efficiency but the cells failed to grow on the surface until the 18th day. In contrast, human albumin was a very potent facilitator of both seeding and proliferation on allografts which was further improved by culturing in a rotating bioreactor. Electron microscopy revealed that cells do not form a monolayer but span the pores, emphasizing the importance of pore size and microstructure. Albumin coated bone chips were able to unite a rat femoral segmental defect, while uncoated ones did not. Micro‐hardness measurements confirmed that albumin coating does not influence the physical characteristics of the scaffold, so it is possible to introduce albumin coating into the manufacturing process of lyophilized bone allografts.
International Journal of Biomaterials | 2011
Jonas Åberg; Eszter Pankotai; Gry Hulsart Billström; Miklós Weszl; Sune Larsson; Csaba Forster-Horváth; Zsombor Lacza; Håkan Engqvist
In this work a radiopaque premixed calcium phosphate cement (pCPC) has been developed and evaluated in vivo. Radiopacity was obtained by adding 0–40 % zirconia to the cement paste. The effects of zirconia on setting time, strength and radiopacity were evaluated. In the in vivo study a 2 by 3.5 mm cylindrical defect in a rat vertebrae was filled with either the pCPC, PMMA or bone chips. Nano-SPECT CT analysis was used to monitor osteoblast activity during bone regeneration. The study showed that by adding zirconia to the cement the setting time becomes longer and the compressive strength is reduced. All materials evaluated in the in vivo study filled the bone defect and there was a strong osteoblast activity at the injury site. In spite of the osteoblast activity, PMMA blocked bone healing and the bone chips group showed minimal new bone formation. At 12 weeks the pCPC was partially resorbed and replaced by new bone with good bone ingrowth. The radiopaque pCPC may be considered to be used for minimal invasive treatment of vertebral fractures since it has good handling, radiopacity and allows healing of cancellous bone in parallel with the resorption of the cement.
Journal of Biomedical Materials Research Part A | 2013
Gry Hulsart-Billström; Wei Xia; Eszter Pankotai; Miklós Weszl; Elin Carlsson; Csaba Forster-Horváth; Sune Larsson; Håkan Engqvist; Zsombor Lacza
Treatment of osteoporotic fractures with conventional surgical methods is associated with a high rate of complications. Intense search for new treatment options includes development of specific biomaterials aimed to be part of the surgical armamentarium. Strontium doped calcium phosphate spheres (SrCPS) is a new material that might be of interest due to the influence on osteoclast and osteoblast activity. In the present study, we successfully constructed hollow spherical SrCPS particles with a diameter of ~700 nm and shell thickness of ~150 nm. The Sr content was about 20 wt %. Cell viability and cytotoxicity were investigated in vitro with concentrations from 0 to 1000 μg/mL of SrCPS in medium extract in a day chase study. The in vivo biocompatibility was tested in a delayed bone-healing model in a rat vertebral defect by histology, μCT, and nanoSPECT. The SrCPS showed no toxicity in vitro with comparable cell number in all concentrations. Increased metabolism was seen in the cell viability study in cells exposed to 400 and 600 μg/mL. SPECT showed good biocompatibility with no local adverse effects and an increased osteoblast activity as compared to adjacent vertebra. SrCPS implantation induced bone formation and resulted in complete resorption and defect consolidation.
Surgical Innovation | 2013
Dénes B. Horváthy; Gabriella Vácz; Attila Cselenyák; Miklós Weszl; Levente Kiss; Zsombor Lacza
Cell therapy holds the promise for a novel modality in the surgical toolkit; however, delivery of cells into damaged soft tissues constitutes a challenge. The authors hypothesized that growing stem cells on the surface of absorbable sutures in vitro and then implanting them via stitching would be a suitable delivery route for cell therapy. Fibronectin, poly-L-lysine, and albumin coatings were used to increase attachment of human and rat bone-marrow-derived mesenchymal stem cells (BMSC) to polyfilament absorbable sutures in vitro. Fluorescence microscopy was performed to localize the cells on the suture. After 48 hours of incubation, the albumin-coated sutures had the highest cell number, and after 168 hours cell number reached confluency. In the in vivo experiments, a 10-mm incision was made on the triceps surae muscle of male Wistar rats and rat BMSC coated sutures were placed into the muscle. Two days after the implantation, cells were seen on the surface of the sutures as well as in the surrounding muscle tissue. Long-term results at 5 weeks showed that transplanted cells survived and the sutures were partly absorbed. In conclusion, coating absorbable sutures with proteins, especially serum albumin, improves attachment and proliferation of cells, and only 48 hours in culture is enough to cover the sutures sufficiently. Using these stitches in vivo resulted in short-term and long-term survival of cells. As a result, albumin-coated suture can be a vehicle for stem cell therapy in soft tissues such as muscle, tendon, or peripheral nerves.
Materials Science and Engineering: C | 2017
Miklós Weszl; Krisztián László Tóth; Imre Kientzl; Péter Nagy; Dávid Pammer; Liza Pelyhe; Nihal Engin Vrana; Dieter Scharnweber; Cornelia Wolf-Brandstetter; F Árpád Joób; Eszter Bognár
OBJECTIVE The objective of this study was to investigate the reproducibility, mechanical integrity, surface characteristics and corrosion behavior of nanotubular (NT) titanium oxide arrays in comparison with a novel nano-pitted (NP) anodic film. METHODS Surface treatment processes were developed to grow homogenous NT and NP anodic films on the surface of grade 2 titanium discs and dental implants. The effect of process parameters on the surface characteristics and reproducibility of the anodic films was investigated and optimized. The mechanical integrity of the NT and NP anodic films were investigated by scanning electron microscopy, surface roughness measurement, scratch resistance and screwing tests, while the chemical and physicochemical properties were investigated in corrosion tests, contact angle measurement and X-ray photoelectron spectroscopy (XPS). RESULTS AND DISCUSSION The growth of NT anodic films was highly affected by process parameters, especially by temperature, and they were apt to corrosion and exfoliation. In contrast, the anodic growth of NP film showed high reproducibility even on the surface of 3-dimensional screw dental implants and they did not show signs of corrosion and exfoliation. The underlying reason of the difference in the tendency for exfoliation of the NT and NP anodic films is unclear; however the XPS analysis revealed fluorine dopants in a magnitude larger concentration on NT anodic film than on NP surface, which was identified as a possible causative. Concerning other surface characteristics that are supposed to affect the biological behavior of titanium implants, surface roughness values were found to be similar, whereas considerable differences were revealed in the wettability of the NT and NP anodic films. CONCLUSION Our findings suggest that the applicability of NT anodic films on the surface of titanium bone implants may be limited because of mechanical considerations. In contrast, it is worth to consider the applicability of nano-pitted anodic films over nanotubular arrays for the enhancement of the biological properties of titanium implants.
Acta Physiologica Hungarica | 2012
Gábor Skaliczki; Miklós Weszl; Károly Schandl; Tibor Major; Miklós Kovács; J. Skaliczki; Heinz Redl; Miklós Szendrői; K. Szigeti; D. Máté; Cs. Dobó-Nagy; Zs Lacza
PURPOSE The clinical demand for bone grafting materials necessitated the development of animal models. Critical size defect model has been criticized recently, mainly for its inaccuracy. Our objective was to develop a dependable animal model that would provide compromised bone healing, and would allow the investigation of bone substitutes. METHODS In the first group a critical size defect was created in the femur of adult male Wistar rats, and a non-critical defect in the remaining animals (Groups II, III and IV). The defect was left empty in group II, while in groups III and IV a spacer was interposed into the gap. Osteoblast activity was evaluated by NanoSPECT/CT imaging system. New bone formation and assessment of a union or non-union was observed by μCT and histology. RESULTS The interposition model proved to be highly reproducible and provided a bone defect with compromised bone healing. Significant bone regeneration processes were observed four weeks after removal of the spacer. CONCLUSION Our results have shown that when early bone healing is inhibited by the physical interposition of a spacer, the regeneration process is compromised for a further 4 weeks and results in a bone defect during the time-course of the study.
Critical Reviews in Biotechnology | 2018
Julien Barthes; Sait Ciftci; Florian Ponzio; Helena Knopf-Marques; Liza Pelyhe; Alexandru Gudima; Imre Kientzl; Eszter Bognár; Miklós Weszl; Julia Kzhyshkowska; Nihal Engin Vrana
Abstract In many biomedical applications, titanium forms an interface with tissues, which is crucial to ensure its long-term stability and safety. In order to exert control over this process, titanium implants have been treated with various methods that induce physicochemical changes at nano and microscales. In the past 20 years, most of the studies have been conducted to see the effect of topographical and physicochemical changes of titanium surface after surface treatments on cells behavior and bacteria adhesion. In this review, we will first briefly present some of these surface treatments either chemical or physical and we explain the biological responses to titanium with a specific focus on adverse immune reactions. More recently, a new trend has emerged in titanium surface science with a focus on the crystalline phase of titanium dioxide and the associated biological responses. In these recent studies, rutile and anatase are the major two polymorphs used for biomedical applications. In the second part of this review, we consider this emerging topic of the control of the crystalline phase of titanium and discuss its potential biological impacts. More in-depth analysis of treatment-related surface crystalline changes can significantly improve the control over titanium/host tissue interface and can result in considerable decreases in implant-related complications, which is currently a big burden on the healthcare system.
PLOS ONE | 2018
Ferenc Budán; Krisztián Szigeti; Miklós Weszl; Ildiko Horvath; Erika Balogh; Reem Kanaan; Károly Berényi; Zsombor Lacza; Domokos Máthé; Zoltán Gyöngyi
Although an extensive research is being undertaken, the ideal bone graft and evaluation method of the bone formation draw still a warranted attention. The purpose of this study was to develop a novel multimodal radiomics evaluation method, utilizing X-ray computed tomography (CT) and single photon emission computed tomography (SPECT) with Tc-99m-Methyl diphosphonate (Tc-99m-MDP) tracer. These modalities are intended to provide quantitative data concerning the mineral bone density (after evaluation it is referred to as opacity) and the osteoblast activity, at the same time. The properties of bone formation process within poly (methyl methacrylate)-based bone cement graft (PMMA) was compared to that of albumin coated, sterilized, antigen-extracted freeze-dried human bone grafts (HLBC), in caudal vertebrae (C5) of rats. The animals were scanned at 3 and 8 weeks after surgery. In both groups, the mean opacity increased, while the mean Tc-99m-MDP activity decreased. The later parameter was significant (n = 4, p = 0.002) only in HLBC group. The linear regression analysis of PMMA-treated group variables (mean opacity increase; mean Tc-99m-MDP activity decrease), revealed a negative correlation with the medium strength (r = 0.395, p = 0.605). Whereas, it showed strong positive correlation when HLBC group variables were analyzed (r = 0.772, p = 0.012). These results indicate that using HLBC grafts is advantageous in terms of the osteoblast activity and bone vascularization over PMMA cement. Using this regression analysis method, we were able to distinguish characteristics that otherwise could not be distinguished by a regular data analysis. Hence, we propose utilizing this novel method in preclinical tests, and in clinical monitoring of bone healing, in order to improve diagnosis of bone-related diseases.
Acta Polytechnica CTU Proceedings | 2016
Péter Nagy; Miklós Weszl; Krisztián László Tóth; Imre Kientzl; György Ring; Péter Szabadíts; Eszter Bognár
Surface characteristics play an important role in the implant-bone integration that is required for the long-term reliability of dental and orthopedic implants. In this paper, we investigate the effect of acid etching on the mass reduction and roughness of grade 2 and grade 5 Ti under controlled experimental conditions. Three different etching compounds were investigated: 30% HCl, 85% H 3 PO 4 and the compound of 30% (COOH) 2 × 2H 2 O and 30% H 2 O 2 in various treatment intervals under controlled temperature. Stereo microscopy, scanning electron microscopy, roughness and weight measurements were carried out on the samples. We found that neither 85% H 3 PO 4 nor the compound of 30% (COOH) 2 × 2H 2 O and 30% H 2 O 2 were able to remove the machining marks from the surface of Ti discs in our experimental setting. On the other hand, etching in 30% HCl yielded even surfaces both on Ti grade 2 and 5 discs. We also found that etching at higher temperatures in 30% HCl resulted in significant mass loss.
International Orthopaedics | 2013
Gábor Skaliczki; Károly Schandl; Miklós Weszl; Tibor Major; Miklós Kovács; József Skaliczki; Miklós Szendrői; Csaba Dobó-Nagy; Zsombor Lacza