Miyuki Noguchi
University of Tokyo
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Miyuki Noguchi.
Chemosphere | 2012
Masahiro Tokumura; Yuko Wada; Yuri Usami; Takako Yamaki; Atsushi Mizukoshi; Miyuki Noguchi; Yukio Yanagisawa
The photo-Fenton reaction was applied as a novel method for the removal of volatile organic compounds (VOCs) in the gas phase, and its effectiveness was experimentally examined. In conventional VOCs removal methods using a photocatalyst or ozone, VOCs are oxidized in the gas phase. Therefore, incompletely oxidized intermediates, which may have adverse effects on health, are likely to contaminate the treated air. On the other hand, in the VOCs removal method developed in this study, because the VOCs are oxidized in the liquid phase by the photo-Fenton reaction, any incompletely oxidized intermediates produced are confined to the liquid phase. As a result, the contamination of the treated air by these harmful intermediates can be prevented. Using a semi-batch process, it was found that the removal efficiency for toluene in a one-pass test (residence time of 17s) was 61%, for an inlet toluene gas concentration of 930 ppbv, an initial iron ion concentration of 20 mg L(-1), and an initial hydrogen peroxide concentration of 630 mg L(-1). The removal efficiency was almost constant as long as H(2)O(2) was present in the solution. Proton transfer reaction mass spectrometry analysis confirmed the absence of any incompletely oxidized intermediates in the treated air.
International Journal of Environmental Research and Public Health | 2010
Atsushi Mizukoshi; Kazukiyo Kumagai; Naomichi Yamamoto; Miyuki Noguchi; Kazuhiro Yoshiuchi; Hiroaki Kumano; Yukio Yanagisawa
While various volatile organic compounds (VOCs) are known to show neurotoxic effects, the detailed mechanisms of the action of VOCs on the autonomic nervous system are not fully understood, partially because objective and quantitative measures to indicate neural abnormalities are still under development. Nevertheless, heart rate variability (HRV) has been recently proposed as an indicative measure of the autonomic effects. In this study, we used HRV as an indicative measure of the autonomic effrects to relate their values to the personal concentrations of VOCs measured by a real-time VOC monitor. The measurements were conducted for 24 hours on seven healthy subjects under usual daily life conditions. The results showed HF powers were significantly decreased for six subjects when the changes of total volatile organic compound (TVOC) concentrations were large, indicating a suppression of parasympathetic nervous activity induced by the exposure to VOCs. The present study indicated these real-time monitoring was useful to characterize the trends of VOC exposures and their effects on autonomic nervous system.
International Journal of Environmental Research and Public Health | 2010
Yusuke Ishizuka; Masahiro Tokumura; Atsushi Mizukoshi; Miyuki Noguchi; Yukio Yanagisawa
Continuous measurements using proton transfer reaction mass spectrometry (PTR-MS) can be used to describe the production processes of secondary products during ozone induced oxidation of terpenes. Terpenes are emitted from woody building materials, and ozone is generated from ozone air purifiers and copy machines in indoor environments. Carbonyl compounds (CCs) are emitted by human activities such as smoking and drinking alcohol. Moreover, CCs are generated during ozone oxidation of terpenes. Therefore, coexistent CCs should affect the ozone oxidation. This study has focused on the measurement of secondary products during the ozone oxidation of terpenes based on the use of PTR-MS analysis and effects of coexistent CCs on oxidized products. Experiments were performed in a fluoroplastic bag containing α-pinene or limonene as terpenes, ozone and acetaldehyde or formaldehyde as coexistent CCs adjusted to predetermined concentrations. Continuous measurements by PTR-MS were conducted after mixing of terpenes, ozone and CCs, and time changes of volatile organic compounds (VOCs) concentrations were monitored. Results showed that, high-molecular weight intermediates disappeared gradually with elapsed time, though the production of high-molecular weight intermediates was observed at the beginning. This phenomenon suggested that the ozone oxidation of terpenes generated ultrafine particles. Coexistent CCs affected the ozone oxidation of α-pinene more than limonene.
Journal of The Air & Waste Management Association | 2009
Kyoko Yamashita; Naomichi Yamamoto; Atsushi Mizukoshi; Miyuki Noguchi; Yueyong Ni; Yukio Yanagisawa
Abstract To characterize potential air pollution issues related to recycling facilities of waste plastics, volatile organic compounds (VOCs) emitted from melted virgin and waste plastics pellets were analyzed. In this study, laboratory experiments were performed to melt virgin and waste plastic pellets under various temperatures (150, 200, and 250 °C) and atmospheres (air and nitrogen [N2]). In the study presented here, low-density polyethylene (LDPE), polypropylene (PP), polystyrene (PS) and the recycled waste plastic pellets were used. The VOCs generated from each plastic pellets were collected by Tenax/Carboxen adsorbent tubes and analyzed by thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS). The result showed the higher temperatures generated larger amounts of total VOCs (TVOCs). The VOCs emitted from the virgin plastic pellets likely originated from polymer degradation. Smaller TVOC emissions were observed in N2 atmosphere than in air atmosphere. In particular, larger amounts of the oxygenated compounds, which are generally hazardous and malodorous, were detected in air than in N2. In addition to the compounds originating from polymer degradation, the compounds originating from the plastic additives were also detected from LDPE and PS. Furthermore, various species of VOCs likely originating from contaminant inseparate polyvinyl chloride (PVC), food residues, cleaning agents, degreasers, and so on were detected from the waste plastic. Thus, melting waste plastics, as is conducted in recycling facilities, might generate larger amounts of potentially toxic compounds than producing virgin plastics.
International Journal of Environmental Research and Public Health | 2015
Atsushi Mizukoshi; Kazukiyo Kumagai; Naomichi Yamamoto; Miyuki Noguchi; Kazuhiro Yoshiuchi; Hiroaki Kumano; Kou Sakabe; Yukio Yanagisawa
In-situ real-time monitoring of volatile organic compound (VOC) exposure and heart rate variability (HRV) were conducted for eight multiple chemical sensitivity (MCS) patients using a VOC monitor, a Holter monitor, and a time-activity questionnaire for 24 h to identify the relationship between VOC exposure, biological effects, and subjective symptoms in actual life. The results revealed no significantly different parameters for averaged values such as VOC concentration, HF (high frequency), and LF (low frequency) to HF ratio compared with previous data from healthy subjects (Int. J. Environ. Res. Public Health 2010, 7, 4127–4138). Significant negative correlations for four subjects were observed between HF and amounts of VOC change. These results suggest that some patients show inhibition of parasympathetic activities along with VOC exposure as observed in healthy subjects. Comparing the parameters during subjective symptoms and normal condition, VOC concentration and/or VOC change were high except for one subject. HF values were low for five subjects during subjective symptoms. Examining the time-series data for VOC exposure and HF of each subject showed that the subjective symptoms, VOC exposure, and HF seemed well related in some symptoms. Based on these characteristics, prevention measures of symptoms for each subject may be proposed.
International Journal of Environmental Research and Public Health | 2010
Kyoko Yamashita; Miyuki Noguchi; Atsushi Mizukoshi; Yukio Yanagisawa
The irreversible removal of acetaldehyde from indoor air via a chemical reaction with amino acids was investigated. To compare effectiveness, five types of amino acid (glycine, l-lysine, l-methionine, l-cysteine, and l-cystine) were used as the reactants. First, acetaldehyde-laden air was introduced into aqueous solutions of each amino acid and the removal abilities were compared. Among the five amino acids, l-cysteine solution showed much higher removal efficiency, while the other amino acids solutions didn’t show any significant differences from the removal efficiency of water used as a control. Next, as a test of the removal abilities of acetaldehyde by semi-solid l-cysteine, a gel containing l-cysteine solution was put in a fluororesin bag filled with acetaldehyde gas, and the change of acetaldehyde concentration was measured. The l-cysteine-containing gel removed 80% of the acetaldehyde in the air within 24 hours. The removal ability likely depended on the unique reaction whereby acetaldehyde and l-cysteine rapidly produce 2-methylthiazolidine-4-carboxylic acid. These results suggested that the reaction between acetaldehyde and l-cysteine has possibilities for irreversibly removing toxic acetaldehyde from indoor air.
International Journal of Environmental Research and Public Health | 2010
Kentaro Oka; Atsushi Iizuka; Yasuo Inoue; Atsushi Mizukoshi; Miyuki Noguchi; Akihiro Yamasaki; Yukio Yanagisawa
A combined integration analysis and real time monitoring (Peak Capture System) system was developed for volatile organic compounds (VOCs). Individual integration analysis and real time monitoring can be used to qualitatively and quantitatively analyze VOCs in the atmosphere and in indoor environments and determine the variation in total VOC (TVOC) concentration with time, respectively. In the Peak Capture System, real time monitoring was used to predict future elevations in the TVOC concentration (peak), and this was used an indicator of when to collect (capture) ambient air samples for integration analysis. This enabled qualitative and quantitative analysis of VOCs when the TVOC concentration was high. We developed an algorithm to predict variation in the TVOC concentration, and constructed an automatic system to initiate air sampling for integration analysis. With the system, auto-sampling and analysis of VOCs in a conventional house were conducted. In comparison with background concentrations, the results of peak analysis enabled identification of compounds whose concentration rose. This also enabled an evaluation of possible VOC emission sources.
International Journal of Environmental Research and Public Health | 2016
Miyuki Noguchi; Atsushi Mizukoshi; Yukio Yanagisawa; Akihiro Yamasaki
We measured temporal changes in concentrations of total volatile organic compounds (TVOCs) and individual volatile organic compounds in a newly built daycare center. The temporal changes of the TVOC concentrations were monitored with a photo ionization detector (PID), and indoor air was sampled and analyzed by Gas Chromatography/Mass Spectrometry (GC/MS) and high performance liquid chromatography (HPLC) to determine the concentrations of the constituent VOCs. The measurements were performed just after completion of the building and again 3 months after completion. The TVOC concentration exceeded 1000 µg·m−3 for all the sampling locations just after completion of building, and decreased almost one tenth after 3 months, to below the guideline values of the TVOC in Japan at 400 µg·m−3. The concentrations of the target VOCs of which the indoor concentrations are regulated in Japan were below the guideline values for all the cases. The air-exchange rates were determined based on the temporal changes of the TVOC concentrations, and it was found that the countermeasure to increase the air exchange rate successfully decrease the TVOC concentration level in the rooms.
Journal of Occupational Health | 2012
Takashi Yorifuji; Miyuki Noguchi; Toshihide Tsuda; Etsuji Suzuki; Soshi Takao; Saori Kashima; Yukio Yanagisawa
Does Open‐air Exposure to Volatile Organic Compounds near a Plastic Recycling Factory Cause Health Effects?: Takashi YORIFUJI, et al. Department of Human Ecology, Okayama University Graduate School of Environmental and Life Science—
International Journal of Environmental Research and Public Health | 2016
Miyuki Noguchi; Saya Tanaka; Kaede Watanabe; Akihiro Yamasaki
We examined the correlation between the odor concentration and the chemical composition of environmental tobacco smoke (ETS). Three types of ETS samples were prepared: secondhand smoke (SHS), thirdhand smoke (THS), and field ETS samples from an outside smoking area. The odor concentrations of the ETS, SHS, and THS samples were determined by the triangle-odor-bag method, and the chemical compositions were determined by proton transfer mass spectrometry. The odor concentration of the SHS samples was three or four orders of magnitude higher than that of the field ETS samples, and three orders of magnitude higher than that of the THS samples. The concentration ratios of the constituent chemicals in THS to those in SHS were about 10−4, corresponding to the ratio of the odor concentration. The concentration ratios of the constituent chemicals in the field ETS samples were much lower than the ratios of the odor concentrations. This suggests that the main contributing components to the odor of the field ETS samples are different from those in SHS and THS. The main contributors of the odor in the field ETS samples could be acetaldehyde, acetonitrile, acetic acid, and other unknown components with a mass-to-charge ratio (m/z) of 39 and 43.