Munish Chauhan
Kyung Hee University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Munish Chauhan.
International Journal of Hyperthermia | 2014
Oh In Kwon; Munish Chauhan; Hyung Joong Kim; Woo Chul Jeong; Hun Wi; Tong In Oh; Eung Je Woo
Abstract Purpose: This study shows the potential of magnetic resonance electrical impedance tomography (MREIT) as a non-invasive RF ablation monitoring technique. Materials and methods: We prepared bovine muscle tissue with a pair of needle electrodes for RF ablation, a temperature sensor, and two pairs of surface electrodes for conductivity image reconstructions. We used the injected current non-linear encoding with multi-echo gradient recalled echo (ICNE-MGRE) pulse sequence in a series of MREIT scans for conductivity imaging. We acquired magnetic flux density data induced by externally injected currents, while suppressing other phase artefacts. We used an 8-channel RF head coil and 8 echoes to improve the signal-to-noise ratio (SNR) in measured magnetic flux density data. Using the measured data, we reconstructed a time series of 180 conductivity images at every 10.24 s during and after RF ablation. Results: Tissue conductivity values in the lesion increased with temperature during RF ablation. After reaching 60 °C, a steep increase in tissue conductivity values occurred with relatively little temperature increase. After RF ablation, tissue conductivity values in the lesion decreased with temperature, but to values different from those before ablation due to permanent structural changes of tissue by RF ablation. Conclusion: We could monitor temperature and also structural changes in tissue during RF ablation by producing spatio-temporal maps of tissue conductivity values using a fast MREIT conductivity imaging method. We expect that the new monitoring method could be used to estimate lesions during RF ablation and improve the efficacy of the treatment.
International Journal of Hyperthermia | 2013
Munish Chauhan; Woo Chul Jeong; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Abstract Purpose: The aim of this study was to show the potential of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging in terms of its capability to detect ablated lesions and differentiate tissue conditions in liver radiofrequency (RF) ablation. Materials and methods: RF ablation procedures were performed in bovine livers using a LeVeen RF needle electrode. Ablation lesions were created using a power-controlled mode at 30, 50, and 70 W for 1, 3, and 5 min of exposure time, respectively. After the ablation, the liver was cut into several blocks including the ablated lesion, and positioned inside a phantom filled with agarose gel. Electrodes were attached on the side of the phantom and it was placed inside the MRI bore. For MREIT imaging, multi-spin-echo pulse sequence was used to obtain the magnetic flux density data according to the injection currents. Results: The conductivity of ablation lesions was significantly changed with the increase of exposure time (pKW < 0.01, Kruskal-Wallis test). With RF powers of 30 and 50 W, significant differences between the coagulation necrosis and hyperaemic rim were observed for more than 5 min and 3 min, respectively (pMW < 0.01, Mann-Whitney test). At 70 W, all cases showed significant differences except 3 min (pMW < 0.01). The positive correlation between the exposure time and tissue conductivity was observed in both two ablation areas (pSC < 0.01, Spearman correlation). Conclusions: This ex vivo feasibility study demonstrates that current MREIT conductivity imaging can detect liver RF ablation lesions without using any contrast media or additional MR scan.
Physics in Medicine and Biology | 2013
Tong In Oh; Hyung Joong Kim; Woo Chul Jeong; Munish Chauhan; Oh In Kwon; Eung Je Woo
In radiofrequency (RF) ablation or hyperthermia, internal temperature measurements and tissue property imaging are important to control their outputs and assess the treatment effect. Recently, magnetic resonance electrical impedance tomography (MREIT), as a non-invasive imaging method of internal conductivity distribution using an MR scanner, has been developed. Its reconstruction algorithm uses measured magnetic flux density induced by injected currents. The MREIT technique has the potential to visualize electrical conductivity of tissue with high spatial resolution and measure relative conductivity variation according to the internal temperature change based on the fact that the electrical conductivity of biological tissues is sensitive to the internal temperature distribution. In this paper, we propose a method to provide a non-invasive alternative to monitor the internal temperature distribution by recovering the electrical conductivity distribution using the MREIT technique. To validate the proposed method, we design a phantom with saline solution and a thin transparency film in a form of a hollow cylinder with holes to create anomalies with different electrical and thermal conductivities controlled by morphological structure. We first prove the temperature maps with respect to spatial and time resolution by solving the thermal conductivity partial differential equation with the real phantom experimental environment. The measured magnetic flux density and the reconstructed conductivity distributions using the phantom experiments were compared to the simulated temperature distribution. The relative temperature variation of two testing objects with respect to the background saline was determined by the relative conductivity contrast ratio (rCCR,%). The relation between the temperature and conductivity measurements using MREIT was approximately linear with better accuracy than 0.22 °C.
Computational and Mathematical Methods in Medicine | 2013
Zi Jun Meng; Saurav Z. K. Sajib; Munish Chauhan; Rosalind J. Sadleir; Hyung Joong Kim; Ohin Kwon; Eung Je Woo
Magnetic resonance electrical impedance tomography (MREIT) is a new modality capable of imaging the electrical properties of human body using MRI phase information in conjunction with external current injection. Recent in vivo animal and human MREIT studies have revealed unique conductivity contrasts related to different physiological and pathological conditions of tissues or organs. When performing in vivo brain imaging, small imaging currents must be injected so as not to stimulate peripheral nerves in the skin, while delivery of imaging currents to the brain is relatively small due to the skulls low conductivity. As a result, injected imaging currents may induce small phase signals and the overall low phase SNR in brain tissues. In this study, we present numerical simulation results of the use of head MREIT for brain tumor detection. We used a realistic three-dimensional head model to compute signal levels produced as a consequence of a predicted doubling of conductivity occurring within simulated tumorous brain tissues. We determined the feasibility of measuring these changes in a time acceptable to human subjects by adding realistic noise levels measured from a candidate 3 T system. We also reconstructed conductivity contrast images, showing that such conductivity differences can be both detected and imaged.
IEEE Transactions on Medical Imaging | 2015
Dong Hyun Kim; Munish Chauhan; Min Oh Kim; Woo Chul Jeong; Hyung Joong Kim; Igor Serša; Oh In Kwon; Eung Je Woo
Electrical conductivities of biological tissues show frequency-dependent behaviors, and these values at different frequencies may provide clinically useful diagnostic information. MR-based tissue property mapping techniques such as magnetic resonance electrical impedance tomography (MREIT) and magnetic resonance electrical property tomography (MREPT) are widely used and provide unique conductivity contrast information over different frequency ranges. Recently, a new method for data acquisition and reconstruction for low- and high-frequency conductivity images from a single MR scan was proposed. In this study, we applied this simultaneous dual-frequency range conductivity mapping MR method to evaluate its utility in a designed phantom and two in vivo animal disease models. Magnetic flux density and B1+ phase map for dual-frequency conductivity images were acquired using a modified spin-echo pulse sequence. Low-frequency conductivity was reconstructed from MREIT data by the projected current density method, while high-frequency conductivity was reconstructed from MREPT data by B1+ mapping. Two different conductivity phantoms comprising varying ion concentrations separated by insulating films with or without holes were used to study the contrast mechanism of the frequency-dependent conductivities related to ion concentration and mobility. Canine brain abscess and ischemia were used as in vivo models to evaluate the capability of the proposed method to identify new electrical properties-based contrast at two different frequencies. The simultaneous dual-frequency range conductivity mapping MR method provides unique contrast information related to the concentration and mobility of ions inside tissues. This method has potential to monitor dynamic changes of the state of disease.
Magnetic Resonance in Medicine | 2018
Rosalind J. Sadleir; Fanrui Fu; Munish Chauhan
A direct method of imaging neural activity was simulated to determine typical signal sizes.
Biomedical Engineering Online | 2013
Munish Chauhan; Woo Chul Jeong; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
BackgroundMagnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface electrodes induces a magnetic flux density distribution inside the imaging object, which results in additional magnetic flux density. To measure the magnetic flux density signal in MREIT, the phase difference approach in an interleaved encoding scheme cancels out the systematic artifacts accumulated in phase signals and also reduces the random noise effect by doubling the measured magnetic flux density signal. For practical applications of in vivo MREIT, it is essential to reduce the scan duration maintaining spatial-resolution and sufficient contrast. In this paper, we optimize the magnetic flux density by using a fast gradient multi-echo MR pulse sequence. To recover the one component of magnetic flux density Bz, we use a coupled partial Fourier acquisitions in the interleaved sense.MethodsTo prove the proposed algorithm, we performed numerical simulations using a two-dimensional finite-element model. For a real experiment, we designed a phantom filled with a calibrated saline solution and located a rubber balloon inside the phantom. The rubber balloon was inflated by injecting the same saline solution during the MREIT imaging. We used the multi-echo fast low angle shot (FLASH) MR pulse sequence for MRI scan, which allows the reduction of measuring time without a substantial loss in image quality.ResultsUnder the assumption of a priori phase artifact map from a reference scan, we rigorously investigated the convergence ratio of the proposed method, which was closely related with the number of measured phase encode set and the frequency range of the background field inhomogeneity. In the phantom experiment with a partial Fourier acquisition, the total scan time was less than 6 seconds to measure the magnetic flux density Bz data with 128×128 spacial matrix size, where it required 10.24 seconds to fill the complete k-space region.ConclusionNumerical simulation and experimental results demonstrated that the proposed method reduces the scanning time and provides the recovered Bz data comparable to what we obtained by measuring complete k-space data.
Biomedical Engineering Letters | 2012
Zijun Meng; Saurav Z. K. Sajib; Munish Chauhan; Woo Chul Jeong; Young Tae Kim; Hyung Joong Kim; Eung Je Woo
Physics in Medicine and Biology | 2014
Woo Chul Jeong; Munish Chauhan; Saurav Z. K. Sajib; Hyung Joong Kim; Igor Serša; Oh In Kwon; Eung Je Woo
Electronics Letters | 2014
Hyung-Joong Kim; Zijun Meng; Saurav Z. K. Sajib; Munish Chauhan; Woo-Chul Jeong; Hun Wi; Oh In Kwon; Eung Je Woo; Tong-In Oh