Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where N.W.L. Schep is active.

Publication


Featured researches published by N.W.L. Schep.


Journal of Trauma-injury Infection and Critical Care | 2004

Computer-Assisted versus Conventional Surgery for Insertion of 96 Cannulated Iliosacral Screws in Patients with Postpartum Pelvic Pain.

N.W.L. Schep; Robert Haverlag; Arie B. van Vugt

BACKGROUND The purpose of this study was to assess the value of fluoroscopy-based computer-assisted surgery (CAS) for the insertion of iliosacral screws. The results of CAS were compared with the results of a conventionally operated prospective control group. Endpoints of this study were fluoroscopy time, guide wire insertion time, operation time and complication rate. METHODS The study group consisted of 24 patients with postpartum pelvic pain syndrome. All patients were treated with a stabilization of the pelvic ring by means of an anterior plate fixation and autologous tricortical bone graft as well as two iliosacral screws bilaterally. Consequently, the results of 48 versus 48 iliosacral screw fixations could be evaluated. Conventionally operated patients were turned from the supine to the prone position intraoperatively, whereas CAS operated patients were operated in the supine position. One surgeon performed all operations. RESULTS The fluoroscopy time in the CAS group was 0.7 minutes versus 1.8 minutes in the conventionally treated group (p < 0.01). The mean insertion time for four guide wires was 20.2 minutes in the CAS versus 19.4 minutes in the conventionally operated group (p = 0.6). The mean operation time in the CAS group was 97 minutes; 116 minutes in the conventional group (p = 0.03). In the CAS group one patient had pain and a sensory deficit of S2 postoperatively. The Fishers exact test showed no difference in complication rate between the two groups (p = 0.26). CONCLUSIONS The fluoroscopy time is decreased with a factor 2.5 using CAS. Guide wire insertion time was similar in both groups. The reduction in operation time using CAS was due to fact that patients were operated in the supine position during the whole procedure. This study shows that CAS is a save technique for insertion of iliosacral screws.


Archives of Orthopaedic and Trauma Surgery | 2010

Simple elbow dislocations: a systematic review of the literature

J. de Haan; N.W.L. Schep; Wim E. Tuinebreijer; Peter Patka; D. den Hartog

ObjectiveTo identify if functional treatment is the best available treatment for simple elbow dislocations.Search strategyElectronic databases MEDLINE, EMBASE, LILACS, and the Cochrane Central Register of Controlled Trials.Selection criteriaStudies were eligible for inclusion if they were trials comparing different techniques for the treatment of simple elbow dislocations.Data analysisResults were expressed as relative risk for dichotomous outcomes and weighted mean difference for continuous outcomes with 95% confidence intervals.Main resultsThis review has included data from two trials and three observational comparative studies. Important data were missing from three observational comparative studies and the results from these studies were extracted for this review. No difference was found between surgical treatment of the collateral ligaments and plaster immobilisation of the elbow joint. Better range of movement, less pain, better functional scores, shorter disability and shorter treatment time were seen after functional treatment versus plaster immobilisation.


Journal of Foot & Ankle Surgery | 2013

Rerupture Rate after Early Weightbearing in Operative Versus Conservative Treatment of Achilles Tendon Ruptures: A Meta-analysis

Dorien M. van der Eng; Tim Schepers; J. Carel Goslings; N.W.L. Schep

Whether Achilles tendon rupture benefits from surgery or conservative treatment remains controversial. Moreover, the outcome can be influenced by the rehabilitation protocol. The goal of the present meta-analysis was to compare the rerupture rate after surgical repair of the Achilles tendon followed by weightbearing within 4 weeks versus conservative treatment with weightbearing within 4 weeks. In addition, a secondary analysis was performed to compare the rerupture rates in patients who started weightbearing after 4 weeks. Seven randomized controlled trials published from 2001 to 2012, with 576 adult patients, were included. The primary outcome measure was the rerupture rate. The secondary outcomes were minor and major complications other than rerupture. In the early weightbearing group, 7 of 182 operatively treated patients (4%) experienced rerupture versus 21 of 176 of the conservatively treated patients (12%). A secondary analysis of the patients treated with late weightbearing showed a rerupture rate of 6% (7 of 108) for operatively treated patients versus 10% (11 of 110) for conservatively treated patients. The differences concerning the rerupture rate in both groups were not statistically significant. No differences were found in the occurrence of minor or major complications after early weightbearing in both patient groups. In conclusion, we found no difference in the rerupture rate between the surgically and nonsurgically treated patients followed by early weightbearing. Weightbearing after 4 weeks also resulted in no differences in the rupture rate in the surgical versus conservatively treated patients. However, surgical treatment was associated with a twofold greater complication rate than conservative treatment.


Journal of Hand Surgery (European Volume) | 2014

Complications following volar locking plate fixation for distal radial fractures: a systematic review.

Abdelali Bentohami; K. de Burlet; N. de Korte; M.P.J. van den Bekerom; J. C. Goslings; N.W.L. Schep

The purpose of this systematic review is to assess the prevalence of complications following volar locking plate fixation of distal radial fractures. A computer-based search was carried out using EMBASE and PUBMED/MEDLINE. Only prospective comparative and prospective cohort studies that presented data concerning complications after treatment of distal radial fractures with a volar locking plate in human adults with a minimal follow-up of 6 months were included. Two quality assessment tools were used to assess the methodological quality of the studies (level of evidence rating according to the Oxford Centre of Evidence Based Medicine and the modified version of the Cochrane Bone, Joint and Muscle Trauma Group’s former quality assessment tool). Thirty three studies were eligible for final assessment. Most complications were problems with nerve and tendon function as well as complex regional pain syndrome. With an overall complication rate of 16.5%, most of which were ‘minor’ complications and low rates of nonunion and malunion, volar locking plate fixation can be considered a reasonably safe treatment option for patients with distal radial fractures.


BMC Musculoskeletal Disorders | 2011

Displaced midshaft fractures of the clavicle: non-operative treatment versus plate fixation (Sleutel-TRIAL). A multicentre randomised controlled trial

Sylvia A. Stegeman; Mireille de Jong; Cornelis F. M. Sier; Pieta Krijnen; Jan W. Duijff; Tom P. H. van Thiel; Piet Rijcke; Nicolaj M. R. Soesman; Tjebbe Hagenaars; Freek D. Boekhoudt; Mark R. de Vries; Gert R. Roukema; Andras F. K. Tanka; Jephta van den Bremer; Hub G. W. M. van der Meulen; Maarten W. G. A. Bronkhorst; Bart A. van Dijkman; Stephan W. A. M. van Zutphen; Dagmar I. Vos; N.W.L. Schep; Martin G. Eversdijk; Ger D. J. van Olden; Johan G. H. van den Brand; Robert Jan Hillen; J.P.M. Frolke; Inger B. Schipper

BackgroundThe traditional view that the vast majority of midshaft clavicular fractures heal with good functional outcomes following non-operative treatment may be no longer valid for all midshaft clavicular fractures. Recent studies have presented a relatively high incidence of non-union and identified speciic limitations of the shoulder function in subgroups of patients with these injuries.AimA prospective, multicentre randomised controlled trial (RCT) will be conducted in 21 hospitals in the Netherlands, comparing fracture consolidation and shoulder function after either non-operative treatment with a sling or a plate fixation.Methods/designA total of 350 patients will be included, between 18 and 60 years of age, with a dislocated midshaft clavicular fracture. The primary outcome is the incidence of non-union, which will be determined with standardised X-rays (Antero-Posterior and 30 degrees caudocephalad view). Secondary outcome will be the functional outcome, measured using the Constant Score. Strength of the shoulder muscles will be measured with a handheld dynamometer (MicroFET2). Furthermore, the health-related Quality of Life score (ShortForm-36) and the Disabilities of Arm, Shoulder and Hand (DASH) Outcome Measure will be monitored as subjective parameters. Data on complications, bone union, cosmetic aspects and use of painkillers will be collected with follow-up questionnaires. The follow-up time will be two years. All patients will be monitored at regular intervals over the subsequent twelve months (two and six weeks, three months and one year). After two years an interview by telephone and a written survey will be performed to evaluate the two-year functional and mechanical outcomes. All data will be analysed on an intention-to-treat basis, using univariate and multivariate analyses.DiscussionThis trial will provide level-1 evidence for the comparison of consolidation and functional outcome between two standardised treatment options for dislocated midshaft clavicular fractures. The gathered data may support the development of a clinical guideline for treatment of clavicular fractures.Trial registrationNetherlands National Trial Register NTR2399


The Open Orthopaedics Journal | 2011

Stability of the Elbow Joint: Relevant Anatomy and Clinical Implications of In Vitro Biomechanical Studies

J. de Haan; N.W.L. Schep; Denise Eygendaal; Gert-Jan Kleinrensink; Wim E. Tuinebreijer; D. den Hartog

The aim of this literature review is to describe the clinical anatomy of the elbow joint based on information from in vitro biomechanical studies. The clinical consequences of this literature review are described and recommendations are given for the treatment of elbow joint dislocation. The PubMed and EMBASE electronic databases and the Cochrane Central Register of Controlled Trials were searched. Studies were eligible for inclusion if they included observations of the anatomy and biomechanics of the elbow joint in human anatomic specimens. Numerous studies of the kinematics, kinesiology and anatomy of the elbow joint in human anatomic specimens yielded important and interesting implications for trauma and orthopaedic surgeons.


BMC Musculoskeletal Disorders | 2011

Fracture Surgery of the extremities with the intra-operative use of 3D-RX: A randomized multicenter trial (EF3X-trial)

M. Suzan H. Beerekamp; Dirk T. Ubbink; Mario Maas; Jan S. K. Luitse; Peter Kloen; Taco J. Blokhuis; Michiel Jm Segers; Meir Marmor; N.W.L. Schep; Marcel G. W. Dijkgraaf; J. Carel Goslings

BackgroundPosttraumatic osteoarthritis can develop after an intra-articular extremity fracture, leading to pain and loss of function. According to international guidelines, anatomical reduction and fixation are the basis for an optimal functional result. In order to achieve this during fracture surgery, an optimal view on the position of the bone fragments and fixation material is a necessity. The currently used 2D-fluoroscopy does not provide sufficient insight, in particular in cases with complex anatomy or subtle injury, and even an 18-26% suboptimal fracture reduction is reported for the ankle and foot. More intra-operative information is therefore needed.Recently the 3D-RX-system was developed, which provides conventional 2D-fluoroscopic images as well as a 3D-reconstruction of bony structures. This modality provides more information, which consequently leads to extra corrections in 18-30% of the fracture operations. However, the effect of the extra corrections on the quality of the anatomical fracture reduction and fixation as well as on patient relevant outcomes has never been investigated.The objective of this study protocol is to investigate the effectiveness of the intra-operative use of the 3D-RX-system as compared to the conventional 2D-fluoroscopy in patients with traumatic intra-articular fractures of the wrist, ankle and calcaneus. The effectiveness will be assessed in two different areas: 1) the quality of fracture reduction and fixation, based on the current golden standard, Computed Tomography. 2) The patient-relevant outcomes like functional outcome range of motion and pain. In addition, the diagnostic accuracy of the 3D-RX-scan will be determined in a clinical setting and a cost-effectiveness as well as a cost-utility analysis will be performed.Methods/designIn this protocol for an international multicenter randomized clinical trial, adult patients (age > 17 years) with a traumatic intra-articular fracture of the wrist, ankle or calcaneus eligible for surgery will be subjected to additional intra-operative 3D-RX. In half of the patients the surgeon will be blinded to these results, in the other half the surgeon may use the 3D-RX results to further optimize fracture reduction. In both randomization groups a CT-scan will be performed postoperatively. Based on these CT-scans the quality of fracture reduction and fixation will be determined. During the follow-up visits after hospital discharge at 6 and 12 weeks and 1 year postoperatively the patient relevant outcomes will be determined by joint specific, health economic and quality of life questionnaires. In addition a follow up study will be performed to determine the patient relevant outcomes and prevalence of posttraumatic osteoarthritis at 2 and 5 years postoperatively.DiscussionThe results of the study will provide more information on the effectiveness of the intra-operative use of 3D-imaging during surgical treatment of intra-articular fractures of the wrist, ankle and calcaneus. A randomized design in which patients will be allocated to a treatment arm during surgery will be used because of its high methodological quality and the ability to detect incongruences in the reduction and/or fixation that occur intra-operatively in the blinded arm of the 3D-RX. An alternative, pragmatic design could be to randomize before the start of the surgery, then two surgical strategies would be compared. This resembles clinical practice better, but introduces more bias and does not allow the assessment of incongruences that would have been detected by 3D-RX in the blinded arm.Trial registrationDutch Trial Register NTR 1902


European Journal of Radiology | 2012

Accuracy and consequences of 3D-fluoroscopy in upper and lower extremity fracture treatment: a systematic review.

M.S.H. Beerekamp; George S.I. Sulkers; Dirk T. Ubbink; Mario Maas; N.W.L. Schep; J. Carel Goslings

OBJECTIVES The aim of this systematic review was to compare the diagnostic accuracy, subjective image quality and clinical consequences of 3D-fluoroscopy with standard imaging modalities (2D-fluoroscopy, X-ray or CT) during reduction and fixation of intra-articular upper and lower extremity fractures. METHODS A systematic literature search was performed in MEDLINE, EMBASE and the Cochrane library. In total 673 articles were identified (up to March 2012). The 19 included studies described patients/cadavers with intra-articular upper/lower extremity fractures and compared 3D-fluoroscopy to standard imaging. The study was performed in accordance with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) guidelines. Diagnostic accuracy was defined by the quality of fracture reduction or implant position and, if possible, expressed as sensitivity and specificity; subjective image quality was determined by the quality of depiction of bone or implants; clinical consequences were defined as corrections in reduction or implant position following 3D-fluoroscopy. RESULTS Ten cadaver- and nine clinical studies were included. A meta-analysis was not possible, because studies used different scoring protocols to express diagnostic accuracy and reported incomplete data. Based on the individual studies, diagnostic accuracy of 3D-fluoroscopy was better than 2D-fluoroscopy and X-ray, but similar to CT-scanning. Subjective image quality of 3D-fluoroscopy was inferior compared to all other imaging modalities. In 11-40% of the operations additional corrections were performed after 3D-fluoroscopy, while the necessity for these corrections were not recognized based on 2D-fluoroscopic images. CONCLUSIONS Although subjective image quality is rated inferior compared to other imaging modalities, intra-operative use of 3D-fluoroscopy is a helpful diagnostic tool for improving the quality of reduction and implant position in intra-articular fractures.


The Open Orthopaedics Journal | 2010

Dislocation of the Elbow: A Retrospective Multicentre Study of 86 Patients

Jeroen de Haan; N.W.L. Schep; Imme Zengerink; Jesse M. van Buijtenen; Wim E. Tuinebreijer; Dennis den Hartog

The objective of this retrospective multicentre cohort study was to prospectively assess the long-term functional outcomes of simple and complex elbow dislocations. We analysed the hospital and outpatient records of 86 patients between 01.03.1999 and 25.02.2009 with an elbow dislocation. After a mean follow-up of 3.3 years, all patients were re-examined at the outpatient clinic for measurement of different outcomes. The mean range of motion was ROM 135.5°. The Mayo elbow performance index (MEPI) scored an average of 91.9 (87.5% of the patients were rated excellent or good). The average Quick disabilities of the arm, shoulder and hand (Quick- DASH) score was 9.7, the sports/music score 11.5 and work score 6.1. The Oxford function score was 75.7, Oxford pain score 75.2 and Oxford social-psychological score 73.9. Elbow dislocation is a mild disease and generally, the outcome is excellent. Functional results might improve with early active movements.


British Journal of Sports Medicine | 2017

Early mobilisation versus plaster immobilisation of simple elbow dislocations: results of the FuncSiE multicentre randomised clinical trial

Gijs I. T. Iordens; Esther M.M. Van Lieshout; N.W.L. Schep; Jeroen de Haan; Wim E. Tuinebreijer; Denise Eygendaal; Ed F. van Beeck; Peter Patka; M.H.J. Verhofstad; Dennis den Hartog

Background/aim To compare outcome of early mobilisation and plaster immobilisation in patients with a simple elbow dislocation. We hypothesised that early mobilisation would result in earlier functional recovery. Methods From August 2009 to September 2012, 100 adult patients with a simple elbow dislocation were enrolled in this multicentre randomised controlled trial. Patients were randomised to early mobilisation (n=48) or 3 weeks plaster immobilisation (n=52). Primary outcome measure was the Quick Disabilities of the Arm, Shoulder, and Hand (Quick-DASH) score. Secondary outcomes were the Oxford Elbow Score, Mayo Elbow Performance Index, pain, range of motion, complications and activity resumption. Patients were followed for 1 year. Results Quick-DASH scores at 1 year were 4.0 (95% CI 0.9 to 7.1) points in the early mobilisation group versus 4.2 (95% CI 1.2 to 7.2) in the plaster immobilisation group. At 6 weeks, early mobilised patients reported less disability (Quick-DASH 12 (95% CI 9 to 15) points vs 19 (95% CI 16 to 22); p<0.05) and had a larger arc of flexion and extension (121° (95% CI 115° to 127°) vs 102° (95% CI 96° to 108°); p<0.05). Patients returned to work sooner after early mobilisation (10 vs 18 days; p=0.020). Complications occurred in 12 patients; this was unrelated to treatment. No recurrent dislocations occurred. Conclusions Early active mobilisation is a safe and effective treatment for simple elbow dislocations. Patients recovered faster and returned to work earlier without increasing the complication rate. No evidence was found supporting treatment benefit at 1 year. Trial registration number NTR 2025.

Collaboration


Dive into the N.W.L. Schep's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wim E. Tuinebreijer

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter Patka

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Tim Schepers

University of Amsterdam

View shared research outputs
Top Co-Authors

Avatar

Dennis den Hartog

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mario Maas

University of Amsterdam

View shared research outputs
Researchain Logo
Decentralizing Knowledge