Napaporn Youngvises
Thammasat University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Napaporn Youngvises.
Analyst | 2006
Gillian M. Greenway; Tapparath Leelasattarathkul; Saisunee Liawruangrath; R. Alan Wheatley; Napaporn Youngvises
A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(II) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2 and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L(-1) H2O2 (correlation coefficient 0.9945). The detection limit (3sigma) and the quantification limit (LOQ) were found to be 1 x 10(-9) and 3.3 x 10(-9) mol L(-1) respectively and the relative standard deviation was 1.37% for 2 x 10(-7) mol L(-1) H2O2 (n = 10). The method was applied to the determination of trace amounts of H2O2 in purified water and natural water samples without any special pre-treatments.
Talanta | 2007
Senee Kruanetr; Saisunee Liawruangrath; Napaporn Youngvises
A simple, inexpensive and reagent-less colorimetric micro flow analysis (microFA) system was implemented in a polymethyl methacrylate (PMMA) micro fluidic manifold. A T-shaped micro channel on a PMMA chip was fabricated by laser ablation and topped with molded polydimethylsiloxane (PDMS). The fabricated microFA system was integrated with the optical components as detector and applied to the determination of iron in water samples. It is based on the measurement of Fe(III)-nitroso-R salt complex at 720 nm formed by the reaction between Fe(III) and nitroso-R salt in an acetate buffer solution pH 5. The proposed microFA consumed very small amount of reagent and sample, it released waste of less than 2.0 mL h(-1). The relative standard deviation (R.S.D.) was less than 2% (n=11) with the recovery of 98.7+/-0.12 (n=5). The linear range for the determination of iron in water samples was over the range of 0.05-4.0 microg mL(-1) with a correlation coefficient (r(2)) of 0.9994. The limit of detection (3sigma) and limit of quantitation (10sigma) were 0.021 microg mL(-1) and 0.081 microg mL(-1), respectively with a sample throughput of 40 h(-1).
Journal of Pharmaceutical and Biomedical Analysis | 2003
Napaporn Youngvises; Boonsom Liawruangrath; Saisunee Liawruangrath
A micellar liquid chromatography (MLC) procedure was developed for the simultaneous separation and determination of lidocaine hydrochloride (LD HCl) and tolperisone hydrochloride (TP HCl) using a short-column C18 (12.5 mm x 4.6 mm, 5 microm), sodium dodecyl sulfate (SDS) with a small amount of isopropanol, and diode array detector. The optimum conditions for the simultaneous determination of both drugs were 0.075 mol l(-1) SDS-7.5% (v/v) isopropanol with a flow rate of 0.7 ml min(-1) and detection at 210 nm. The LOD (2S/N) of LD HCl was 0.73 ng 20 microl(-1), whereas that of TP HCl was 1.43 ng 20 microl(-1). The calibration curves for LD HCl and TP HCl were linear over the ranges 0.125-500 microg ml(-1) (r(2)=0.9999) and 1.00-500 microg ml(-1) (r(2)=0.9997), respectively. The %recoveries of both drugs were in the range 98-103% and the %RSD values were less than 2. The proposed method has been successfully applied to the simultaneous determination of TP HCl and LD HCl in various pharmaceutical preparations.
Talanta | 2011
Piyanut Pinyou; Napaporn Youngvises; Jaroon Jakmunee
Ceric ammonium nitrate has been used for qualitative analysis of ethanol. It forms an intensely colored unstable complex with alcohol. In this work, a simple flow injection (FI) colorimetric method was developed for the determination of ethanol, based on the reaction of ethanol with ceric ion in acidic medium to produce a red colored product having maximum absorption at 415 nm. Absorbance of this complex could be precisely measured in the FI system. A standard or sample solution was injected into a deionized water donor stream and flowed to a gas diffusion unit, where the ethanol diffused through a gas permeable membrane made of plumbing PTFE tape into an acceptor stream to react with ceric ammonium nitrate in nitric acid. Color intensity of the reddish product was monitored by a laboratory made LED based colorimeter and the signal was recorded on a computer as a peak. Peak height obtained was linearly proportional to the concentration of ethanol originally presented in the injected solution in the range of 0.1-10.0% (v/v) (r(2)=0.9993), with detection limit of 0.03% (v/v). With the use of gas diffusion membrane, most of the interferences could be eliminated. The proposed method was successfully applied for determination of ethanol in some alcoholic beverages, validating by gas chromatographic method.
Talanta | 2013
Napaporn Youngvises; Thanatcha Chaida; Supada Khonyoung; Nattawan Kuppithayanant; Warawut Tiyapongpattana; Arunporn Itharat; Jaroon Jakmunee
In this research, a greener chromatography employing a short column, Zorbax SB C18 cartridge (12.5 × 4.6 mm, 5 μm) commonly used as a guard column in a reverse phase high performance liquid chromatography (RP-HPLC), was utilized as the analytical column in conjunction with a more eco-friendly micellar mobile phase of sodium dodecyl sulfate (SDS) for separation tertiary mixtures of local anesthetics and antihistamines; and binary mixture of colds drugs; and quaternary mixture of some parabens with different separation conditions. The chromatographic behavior of these analytes was studied to demonstrate separation efficiency of this guard column in a micellar mobile phase. Moreover, this column and SDS mobile phase was exploited for determination of parabens in 64 samples of cosmetic product, both those that were produced locally in the community and those that were commercially manufactured. Linear calibration graphs of the parabens as detected at 254 nm were obtained in the range of 1-100 μmol L(-1) with R(2)>0.9990. Percentage recoveries were 92.4-109.2 with %RSD<3, and the limit of detection and quantitation were 0.04-0.10 and 0.20-0.80 μmol L(-1), respectively. This analytical system is not only greener but also faster and employing simpler sample preparation than a conventional liquid chromatographic system.
Talanta | 2017
Napaporn Youngvises; Kittigan Suwannasaroj; Jaroon Jakmunee; Awadh O. AlSuhaimi
Multi-reverse flow injection analysis (Mr-FIA) integrated with multi-optical sensor was developed and optimized for the simultaneous determination of multi ions; Mn(II), Fe(II), Cu(II) and Fe(III) in water samples. The sample/standard solutions were propelled making use of a four channels peristaltic pump whereas 4 colorimetric reagents specific for the metal ions were separately injected in sample streams using multi-syringe pump. The color zones that formed in the individual mixing coils were then streamed into multi-channels spectrometer, which comprised of four flows through cell and four pairs of light emitting diode and photodiode, whereby signals were measured concurrently. The linearity range (along with detection limit, µgL-1) was 0.050-3.0(16), 0.30-2.0 (11), 0.050-1.0(12) and 0.10-1.0(50)mgL-1, for Mn(II), Fe(II), Cu(II) and Fe(III), respectively. In the interim, the correlation coefficients were 0.9924-0.9942. The percentages relative standard deviation was less than 3. The proposed system was applied successfully to determine targeted metal ions simultaneously in natural water with high sample throughput and low reagent consumption, thus it satisfies the criteria of Green Analytical Chemistry (GAC) and its goals.
Analytical Sciences | 2015
Napaporn Youngvises; Porapichcha Thanurak; Thanatcha Chaida; Jaroon Jukmunee; Awadh O. AlSuhaimi
Microfluidics minimize the amounts of reagents and generate less waste. While microdevices are commonly single-sided, producing a substrate with microchannels on multiple surfaces would increase their usefulness. Herein, a polymethymethacrylate substrate incorporating microchannel structures on two sides was sandwiched between two polydimethylsiloxane sheets to create a multi-analysis device, which was used for the spectrophotometric analysis of the ferrous ion (Fe(2+)) and the ferric ion (Fe(3+)), by utilizing colorimetric detection. To monitor the signals from both channel networks, dual optical sensors were integrated into the system. The linear ranges for Fe(2+) and Fe(3+) analyses were 0.1 - 20 mg L(-1) (R(2) = 0.9988) and 1.0 - 40 mg L(-1) (R(2) = 0.9974), respectively. The detection limits for Fe(2+) and Fe(3+) were 0.1 and 0.5 mg L(-1), respectively. The percent recoveries of Fe(2+) and Fe(3+) were 93.5 - 104.3 with an RSD < 8%. The microdevice demonstrated capabilities for simultaneous analysis, low waste generation (7.2 mL h(-1)), and high sample throughput (180 h(-1)), making it ideal for greener analytical chemistry applications.
Spectroscopy Letters | 2009
Awadh O. AlSuhaimi; Gullian M. Greenway; Tom McCreedy; Napaporn Youngvises
ABSTRACT A simple miniaturized system was fabricated in general laboratory from polydimethylsiloxane (PDMS) according to a prototype casting and molding process permitting the construction of three-dimensional (3D) microchannel (100 µm i.d.) with T-type network, together with an integrated optical sensor for on chip detection. The fabricated device has been successfully applied as a green chemistry-compatible miniaturized analytical system for the determination of zinc (II) in pharmaceutical samples taking the advantage of the colorimetric reaction of zinc (II) and xylenol orange in acetate buffer at pH 5.5. The microfluidic device is a convenient way to quantify zinc (II) over a wide dynamic range, 0.2–2.5 µg mL−1, with good linearity (R2 0.9940).
Talanta | 2007
Tapparath Leelasattarathkul; Saisunee Liawruangrath; Mongkon Rayanakorn; Boonsom Liawruangrath; Winai Oungpipat; Napaporn Youngvises
Analytical Sciences | 2012
Sam-ang Supharoek; Napaporn Youngvises; Jaroon Jakmunee